• Title/Summary/Keyword: body area

Search Result 3,878, Processing Time 0.031 seconds

Development of electrode tips for spot welding to reduce indentation of car body surface of stainless rolling stocks (스텐레스 철도차량 외판 압흔 깊이 감소를 위한 스폿용접용 전극팁 개발)

  • 서승일
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.386-391
    • /
    • 2002
  • Stainless rolling stocks are usually fabricated by spot welding process without painting. Indentation on the surface of the car body after spot welding injures the beauty of the stainless rolling stocks. In this study, electrode tips to reduce the indentation are developed and applied to the actual spot welding works. The developed tips are composed of head, nut hole far cooling water, body and resistance material. They provide large surface contact area with the base materials during spot welding and enhance the current density by necking. Experimental results using the developed tips show that small indentation and sufficient tensile shear strength is produced due to large contact area and enhanced current density.

  • PDF

A study on consumer's preference for size labeling system of womens's ready-to-wear garments

  • 천종숙
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.105-117
    • /
    • 1996
  • This study was initiated to investigate (1) whether consumers preferred a specific garment size labeling system and (2) whether consumer's demographic characteristics, clothing behavior, and body size affect their preference of size labeling systems. The survey of consumer's preferences for five size labeling systems included 443 women with 20 to 64 years of age. The result of the survey showed that the subjects' preferences of five size labeling sysems were different significantly. Subjects strongly preferred the old system rather than the revised systems. The subjects least preferred the system with pictogram(system D) and the system with description of the measuring methods of te control dimensions (system E). The subjects/ preference for various garment size labeling systems was different depending on their resident area, educational level, and body size. The garment size labeling system with more information on body measurements (system C) was preferred by the subjects living in the metro city area or subjects having difficulties on purchasing ready-to-wear garments giving reasonable fit. The simplest size labeling system (system A) was strongly preferred by the subjects of low educational level, or the subjects living in the small city.

  • PDF

A 30-year neglected foreign body mimicking a maxillary fracture

  • Lee, Wang Seok;Park, Eun Soo;Kang, Sang Gue;Tak, Min Sung;Kim, Chul Han
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.195-198
    • /
    • 2019
  • A-50-year-old male patient presented with complaint of tenderness on the left malar area after traffic accident. Our first impression on him was zygomatic fracture, we did radiologic work-up and physical examination on him. But, on the computed tomography scan, there was no fracture or discontinuity on his facial bone. The computed tomography scan was revealed a 4-cm long foreign body in left maxillary sinus with a large amount of fluid collection. After thorough history taking from him, we reveal the patient had a history of trauma 30 years back on the left zygomatic area with a chopstick. The foreign body was removed via transoral approach with the endoscopic assist. There was no complication after operation.

INVARIANCE OF THE AREA OF OVALOIDS

  • Youngwook Kim;Sung-Eun Koh;Hyung Yong Lee;Heayong Shin;Seong-Deog Yang
    • Bulletin of the Korean Mathematical Society
    • /
    • v.61 no.4
    • /
    • pp.1107-1119
    • /
    • 2024
  • Consider a two dimensional smooth convex body with a marked point on the boundary of it, sitting tangentially at the marked point over a base curve in 𝔼2, ℍ2 or 𝕊2 and the image of this body by the reflection with respect to the tangent line of the base curve at the marked point. When we roll these two bodies simultaneously along the base curve, the trajectories of the marked point bound a closed region. We show that the area of the closed region is independent of the shape of the base curve if the base curve is not highly curved with respect to the boundary curve of the convex body.

Mean Value of Median Nerve Cross-sectional Area in Healthy 20s and 30s in Busan Area

  • Kang, Kyoung-Hwa;Lee, Gil-Hyun;Choi, Go-Eun;Hyun, Kyung-Yae
    • Biomedical Science Letters
    • /
    • v.26 no.3
    • /
    • pp.186-191
    • /
    • 2020
  • This study was designed to investigate the median nerve cross-sectional area of the upper extremity which is the main cause of CTS in the 20s and 30s. The median nerve cross-sectional area (MNC-area) of each part of the upper limb was measured in healthy 20s and 30s females and males without neurological diseases or other diseases. This MNC-area was compared with the hand, wrist, finger, and other body indexes. The research group was divided into 20s female and male groups, and the 30s were also divided into female and male groups. In the comparison between the ages, the hand, and wrist configurations in the 30s were significantly higher than those of the 20s. The mean median nerve cross-sectional area was significantly larger in the male group than in the female group in both 20s and 30s, and it was larger in both men and women than in the 20s. Hand and wrist configurations were also positively correlated with the median nerve cross-sectional area in both 20s and 30s. The median values of hand ratio and wrist ratio were 2.26 and 0.65, respectively. This median value of hand ratio was inversely correlated with the median nerve cross-sectional area. The median nerve cross-area of the 20s was 6.88~7.38 ㎟ in the male group and 5.69~6.99 ㎟ in the female group, respectively. The median nerve cross-area of the 30s was 6.32~8.89 ㎟ in the male group and 6.15~7.17 ㎟ in the female group, respectively. The mean median nerve cross-sectional area was positively correlated with body mass index in both groups. Most of the variables were higher in their 30s than in their 20s.

Classification of adult male torso shapes using 3D body scan data (3D 스캔 데이터에 의한 성인 남성의 체간부 형태 유형화)

  • Hong, Eun-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.4
    • /
    • pp.165-179
    • /
    • 2019
  • This study used 3D body scan data to classify body shapes according to the torso shape of adult males aged 20-75 years. This data will be provided so that the apparel industry can make apparel products corresponding to body characteristics by age. The study used 1,796 adult males between the ages of 20 and 75 and the 3D body shape data of the '5th Research on National Standard Anthropometry'. For data analysis, the program SPSSWIN Ver. 17.0 was used to calculate the mean and frequency allowing for a factor analysis, cluster analysis, analysis of variance, and Duncan test. To classify body shape according to the torso shape of adult males, this study considered nine factors: 'horizontal size of torso,' 'vertical size of body,' 'curve of torso and waist-abdomen flatness ratio,' 'length of torso,' 'shape of neck area,' 'degree of lateral curve,' 'difference between front and back interscye length,' 'shoulder armscye shape,' and 'chest flatness ratio.' Based on the results of the factor analysis, the torso shapes of adult males were classified into five types. Type 1 is "upright body with flat, curvy shape", Type 2 is "curve sway back body type", Type 3 is "flat, abdominally obese body", Type 4 is "obese, crooked body" and Type 5 is "thick sway front body type." named.

A Secure Medical Information Management System for Wireless Body Area Networks

  • Liu, Xiyao;Zhu, Yuesheng;Ge, Yu;Wu, Dajun;Zou, Beiji
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.1
    • /
    • pp.221-237
    • /
    • 2016
  • The wireless body area networks (WBANs) consist of wearable computing devices and can support various healthcare-related applications. There exist two crucial issues when WBANs are utilized for healthcare applications. One is the protection of the sensitive biometric data transmitted over the insecure wireless channels. The other is the design of effective medical management mechanisms. In this paper, a secure medical information management system is proposed and implemented on a TinyOS-based WBAN test bed to simultaneously address these two issues. In this system, the electronic medical record (EMR) is bound to the biometric data with a novel fragile zero-watermarking scheme based on the modified visual secret sharing (MVSS). In this manner, the EMR can be utilized not only for medical management but also for data integrity checking. Additionally, both the biometric data and the EMR are encrypted, and the EMR is further protected by the MVSS. Our analysis and experimental results demonstrate that the proposed system not only protects the confidentialities of both the biometric data and the EMR but also offers reliable patient information authentication, explicit healthcare operation verification and undeniable doctor liability identification for WBANs.

A Scalable Wireless Body Area Network for Bio-Telemetry

  • Saeed, Adnan;Faezipour, Miad;Nourani, Mehrdad;Banerjee, Subhash;Lee, Gil;Gupta, Gopal;Tamil, Lakshman
    • Journal of Information Processing Systems
    • /
    • v.5 no.2
    • /
    • pp.77-86
    • /
    • 2009
  • In this paper, we propose a framework for the real-time monitoring of wireless biosensors. This is a scalable platform that requires minimum human interaction during set-up and monitoring. Its main components include a biosensor, a smart gateway to automatically set up the body area network, a mechanism for delivering data to an Internet monitoring server, and automatic data collection, profiling and feature extraction from bio-potentials. Such a system could increase the quality of life and significantly lower healthcare costs for everyone in general, and for the elderly and those with disabilities in particular.

Extracting gall bladders from ultrasound images

  • Kim, Hyoung-Seop;Ishikawa, Seiji;Kato, Kiyoshi;Tsukuda, Masaaki;Matsuoka, Jun-nosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.248-251
    • /
    • 1995
  • Nowadays, the internal images of a human body can be easily provided by the ultrasound imaging, the X-ray CT, or the MRI device, among which the ultrasound imaging device has good resolution for soft tissues of a human body compared with the other devices. Furthermore, the use of ultrasound imaging devices will increase in future especially in the obstetrics, territory, since it does not give harm to the human body. Although several techniques have been investigated until now in order to extract organs from ultrasound images, very few of them have achieved satisfactory results because of low contrast and high noise nature of images. This paper proposes a technique for automatic extraction of the gall bladder area from ultrasound images. The proposed technique first extracts a small reliable area of a gall bladder from an ultrasound image employing smoothing, binarization, expanding and shrinking, and labeling, and then expands the area referring to the binarized version of the original image. The technique is examined its performance by real ultrasound images of a gall bladder and satisfactory results are obtained. Some problems to be solved are discussed finally.

  • PDF

Link Budget Analysis of Communication System for Reliable WBAN (신뢰성있는 WBAN을 위한 통신 시스템의 링크 버짓 분석)

  • Roh, Jae-sung
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.6
    • /
    • pp.584-588
    • /
    • 2019
  • Wireless body area network (WBAN) is a networking technology that enables early detection of abnormal health conditions, real-time medical monitoring, and telemedicine support systems. The internet of things (IoT) for healthcare, which has become an issue recently, is one of the most promising areas for improving the quality of human life. It must meet the high QoS requirements of the medical communication system like any other communication system. Therefore, the bit error rate (BER) threshold was chosen to accommodate the QoS requirements of the WBAN communication system. In this paper, we calculated BER performance of WBAN channel using IR-UWB PPM modulation and analyzed link budget and system margin of WBAN according to various system parameters.