The Importance of Filter Integrity Test to Ensure Sterility of Radiophamaceuticals for Using PET Image

  • Cho, Yong-Hyun;Park, Jun-Hyung;Hwang, Ki-Young;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.74-77
    • /
    • 2008
  • The radiopharmaceuticals are routinely injected to blood vessel for acquiring PET image. For this reason, It is imperative that they undergo strict quality control measures. Especially, Sterility test is more important than any other quality control procedures. According to the FDA guideline, It requires filter integrity test used in the processing of sterile solutions. Among several methods, we can decide to use bubble point test. We usually use vented GS-filters (Millipore co., USA) which are sterilizinggrade (0.22 um pore size) and are placed upper site on product vial. After the synthesis of $^{18}F$-FDG, solutions wet the membrane in filter and then go into the product vial. By all synthesis steps have finished, we can observe the presence of the bubbles in the product vial. Since we have started this study, we have never found any bubbles in the product vial. Because the maximum pressure intensity of the filter which has set by manufacturer is up to 5 bars, but helium gas pressure is up to 1 bar in our module system. So, we can make 5 bars pressure using helium gas bombe and increase pressure up to 5 bars step by step. However, it does not happen to anything in vial.

  • PDF

Neuroprotective Effect of Visnagin on Kainic Acid-induced Neuronal Cell Death in the Mice Hippocampus

  • Kwon, Min-Soo;Lee, Jin-Koo;Park, Soo-Hyun;Sim, Yun-Beom;Jung, Jun-Sub;Won, Moo-Ho;Kim, Seon-Mi;Suh, Hong-Won
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.5
    • /
    • pp.257-263
    • /
    • 2010
  • Visnagin (4-methoxy-7-methyl-5H-furo[3,2-g][1]-benzopyran-5-one), which is an active principle extracted from the fruits of Ammi visnaga, has been used as a treatment for low blood-pressure and blocked blood vessel contraction by inhibition of calcium influx into blood cells. However, the neuroprotective effect of visnagin was not clearly known until now. Thus, we investigated whether visnagin has a neuroprotective effect against kainic acid (KA)-induced neuronal cell death. In the cresyl violet staining, pre-treatment or post-treatment visnagin (100 mg/kg, p.o. or i.p.) showed a neuroprotective effect on KA ($0.1{\mu}g$) toxicity. KA-induced gliosis and proinflammatory marker (IL-$1{\beta}$, TNF-${\alpha}$, IL-6, and COX-2) inductions were also suppressed by visnagin administration. These results suggest that visnagin has a neuroprotective effect in terms of suppressing KA-induced pathogenesis in the brain, and that these neuroprotective effects are associated with its anti-inflammatory effects.

Screening Herbal Decoction of the Vascular Relaxation in Korean Medicine (한의학(韓醫學)에서 사용되는 한약제제(韓藥製劑)의 혈관이완 효능검색)

  • Kim, Hye-Yoom;Seo, Chang-Seob;Shin, Hyeun-Kyoo;Hong, Mi-Hyeon;Yoon, Jung-Joo;Ahn, You-Mee;Eun, So-Young;Lee, Yun-Jung;Lee, Ho-Sub;Kang, Dae-Gill
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.1
    • /
    • pp.43-56
    • /
    • 2018
  • Objectives: This study was designed to investigate the basis for developing the herbal decoction that may help promote healthy blood vessels in accordance with the basic principles of Korean medicinal materials. Methods: In this study, we investigated the vascular relaxation effects of fifty herbal decoctions on vascular response in isolated thoracic aorta of phenylephrine-preconracted rats. Results: The results of identify the vascular relaxation effect of fifty herbal decoctions provided by Korea Institute of Korean Medicine, twenty-one herbal decoctions showed vascular relaxation effects. Among them, four herbal decoctions, Mahwang-tang (麻黃湯), Samchulgeonbi-tang (參朮健脾湯), Cheonwangbosim-dan (天王補心丹), and Socheonglyong-tang (小靑龍湯), with showed significantly concentration-dependent vasodilation was examined. Vascular relaxation level are $84.02{\pm}4.70$, $79.39{\pm}13.9$, $51.26{\pm}12.56$, and $54.73{\pm}15.8%$, respectively (P<0.05, 0.01, and 0.001). Conclusions: Thus these results provide a basic data for the treatment of the impairment of vascular function and blood pressure in traditional Oriental medicine.

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

Effects of Acupuncture Stimulation on the Radial artery's Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study

  • Shin, Jae-Young;Ku, Boncho;Kim, Tae-Hun;Bae, Jang Han;Jun, Min-Ho;Lee, Jun-Hwan;Kim, Jaeuk U.
    • Journal of Pharmacopuncture
    • /
    • v.19 no.3
    • /
    • pp.197-206
    • /
    • 2016
  • Introduction: This study aims to investigate the effects of acupuncture stimulation on the radial artery's pressure pulse wave, along with various hemodynamic parameters, and to explore the possible underlying mechanism of pulse diagnosis in healthy participants in their twenties. Methods and analysis: This study is a prospective, single-arm, exploratory clinical study. A total of 25 healthy participants, without regard to gender, in their twenties will be recruited by physicians. Written informed consent will be obtained from all participants. The participants will receive acupuncture once at ST36 on both sides. The radial arterial pulse waves will be measured on the left arm of the subjects by using an applicable pulse tonometric device (KIOM-PAS). On the right arm (appearing twice), electrocardiogram (ECG), photoplethysmogram (PPG), respiration and cardiac output (CO) signals, will be measured using a physiological data acquisition system (Biopac module), while the velocity of blood flow, and the diameter and the depth of the blood vessel will be measured using an ultrasonogram machine on the right arm (appearing twice). All measurements will be conducted before, during, and after acupuncture. The primary outcome will be the spectral energy at high frequencies above 10 Hz ($SE_{10-30Hz}$) calculated from the KIOM-PAS device signal. Secondary outcomes will be various variables obtained from the KIOM-PAS device, ECG, PPG, impedance cardiography modules, and an ultrasonogram machine. Discussion: The results of this trial will provide information regarding the physiological and the hemodynamic mechanisms underlying acupuncture stimulation and clinical evidence for the influence of acupuncture on the pressure pulse wave in the radial artery. Ethics and dissemination: This study was approved by the Institutional Review Board (IRB) of Kyung Hee University's Oriental Medical Center, Seoul, Korea (KOMCIRB-150818-HR-030). The study findings will be published in peer-reviewed journals and presented at national and international conferences. Trial registration number: This trial was registered with the Clinical Research Information Service (CRIS) at the Korea National Institute of Health (NIH), Republic of Korea (KCT0001663), which is a registry in the World Health Organization's (WHO's) Registry Network.

Association of Uric Acid Levels with Arterial Stiffness in Korean Women and Non-smoking Men

  • Sull, Jae Woong;Koh, Eun Na;Cho, Sung Kweon;Bae, Hyung-Joon;Jee, Sun Ha
    • Biomedical Science Letters
    • /
    • v.23 no.3
    • /
    • pp.201-207
    • /
    • 2017
  • Measuring the pulse wave velocity (PWV) is a non-invasive method for evaluating the stiffness of the vessel wall. While previous studies investigated the association of uric acid level with arterial stiffness, most did not consider smoking status and obesity as covariates. The objective of this study was to investigate the relationship between uric acid levels and arterial stiffness, considering smoking status and obesity. We studied 3390 subjects (1940 males and 1450 females). Abnormal PWV was also defined as the highest quartile of values in the subjects. Data were analyzed using Pearson correlation, t-test, and multiple regression analysis. Approximately 41.9% of men and 3.7% of women were current smokers. Prevalence of hypertension was 11.4% in men and 7.0% in women. In women, hyperuricemia was associated with abnormal PWV (OR 1.58; 95% CI 1.03~2.43). Hyperuricemia was also associated with abnormal PWV (OR 2.37; 95% CI 1.01~5.59) in non- or light male smokers with normal blood pressure. This study suggests that uric acid is associated with arterial stiffness in women and non-smoking men.

Mathematical Modeling for Estimation of Heart Work (심장 일의 측정을 위한 수학적 모델링)

  • Suh, Sang-Ho;Kaptan, Yalin;Roh, Hyung-Woon;Song, Ji-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.145-151
    • /
    • 2012
  • Evaluation of the heart work is starting to emerge as a new diagnostic tool for arterial diseases. The aim of this study is to develop a mathematical model for the estimation of heart work utilizing the pulse waves between two points of a vessel. In order to calculate heart work, medical data such as blood pressure waveforms (which are measured using a cuff) are utilized. The heart work is calculated by employing the modified Windkessel model together with the viscosity models of Casson or Herschel-Bulkely (H-B). The results indicate that the compliance values at the proximal and distal locations differ for the Casson and H-B models.

Numerical Study of Pulsatile Blood Flow in Stenotic Artery (협착 동맥에서의 맥동 혈류 유동에 대한 수치해석적 연구)

  • Seo, Tae-Won;Buriev, Bahtiyor
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.891-896
    • /
    • 2008
  • In the present computational study, simple stenotic artery models using pulsatile flow condition were investigated. A 1 Hz non-reversing sinusoidal velocity for pulsatile flow was imposed at the flow inlet and the corresponding Womersley number based on the vessel radius is 2.75. The simple stenotic geometries have been used that consist of 25%, 50% and 75% semicircular constriction in a cylindrical tube. In this paper, numerical solutions are presented for a first harmonic oscillatory flow using commercial software ADINA 8.4. As stenosis and Reynolds number increase, the maximum wall shear stress(WSS) increases while the minimum WSS decreases. As the stenotic rate increases, the pressure drop at the throat severely decreases to collapse the artery and plaque. It is found that the fluid mechanical disturbances due to the constriction were highly sensitive with rate of stenosis and Reynolds number. When Reynolds number and stenosis increase, the larger recirculation region exists. In this recirculation region the possibility of plaque attachment is increasingly higher. The present results enhance our understanding of the hemodynamics of a stenotic artery.

A novel low-profile flow sensor for monitoring of hemodynamics in cerebral aneurysm

  • Chen, Yanfei;Jankowitz, Brian T.;Cho, Sung Kwon;Yeo, Woon-Hong;Chun, Youngjae
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.2
    • /
    • pp.71-84
    • /
    • 2015
  • A low-profile flow sensor has been designed, fabricated, and characterized to demonstrate the feasibility for monitoring hemodynamics in cerebral aneurysm. The prototype device is composed of three micro-membranes ($500-{\mu}m$-thick polyurethane film with $6-{\mu}m$-thick layers of nitinol above and below). A novel super-hydrophilic surface treatment offers excellent hemocompatibility for the thin nitinol electrode. A computational study of the deformable mechanics optimizes the design of the flow sensor and the analysis of computational fluid dynamics estimates the flow and pressure profiles within the simulated aneurysm sac. Experimental studies demonstrate the feasibility of the device to monitor intra-aneurysmal hemodynamics in a blood vessel. The mechanical compression test shows the linear relationship between the applied force and the measured capacitance change. Analytical calculation of the resonant frequency shift due to the compression force agrees well with the experimental results. The results have the potential to address important unmet needs in wireless monitoring of intra-aneurysm hemodynamic quiescence.

NMDA Receptor and NO Mediate ET-1-Induced Behavioral and Cardiovascular Effects in Periaqueductal Gray Matter of Rats

  • Ryu, Jung-Su;Shin, Chang-Yell;Yang, Sung-Jun;Lee, Tai-Sang;La, Hyun-O;Song, Hyun-Ju;Yom, Yoon-Ki;Huh, In-Hoi;Sohn, Uy-Dong
    • Archives of Pharmacal Research
    • /
    • v.24 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • Endothelin-1 (ET-1 ), a novel and potent vasoconstrictor in blood vessel, is known to have some functions in the rat central nervous system (CNS), In order to investigate the central functions of ET-1 , ET-1 was administered to the periaqueductal gray area (PAC) of anesthetized rats to induce barrel rolling and increase the arterial blood pressure (ABP). ET-1 had a modulatory effect on central cardiovascular and behavioral control. The selective N-methyl-D-aspartate (NMDA) receptor antagonist MK-801 (3${u}m/ol/kg$, i.p.) blocked the ET-1 induced responses, and both the nitric oxide synthase (NOS) inhibitor L-NAME (N-nitro-L-arginine mIThyl-ester 1 nmol/rat) and the nitric oxide (NO) scavenger hemoglobin (15 nmol/rat) had similar effects in redtAcing the IT-1 (10 pmol/rat)-induced behavioral changes and ABP elevation. However, NO donor sodium nitroprusside (SNP 10${u}g$, 1${u}g/rat$) decreased the ET-1 induced ABP elevation, and recovered the ET-1 -induced barrel rolling effect that was reduced by MK-801. These results suggest that ET-1 might have neuromodulatory functions such as ABP elevation and barrel rolling induction in the PAG of the rats via the NMDA receptor and NO.

  • PDF