• 제목/요약/키워드: biomedical

검색결과 13,264건 처리시간 0.039초

치과용 임플란트의 형상과 계면 응력의 상관관계 (The relation between shape and interfacial stress of dental implants)

  • 김한성;이상업;조남효;고재영;박상수;이훈;안세영;심준성;이철영;문홍석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.128-131
    • /
    • 2002
  • Several FE models were developed based on micro-CT images of a mandibular specimen. A new dental implant model was suggested from parameter study for the relation between shape and interfacial stress of dental implants. It is found that the proposed model is highly beneficial.

  • PDF

Anti-inflammatory Effect of Indirubin-3'-Monoxime-5-Sulphonic Acid on Lipopolysaccharide-stimulated Murine Macrophage

  • Park, Gang-Baek;Kim, Hyun-Jin;Heo, Hye-Seon;Park, Geun-Mook;Park, Kyung-Woo;Kim, Jin-Kyung
    • 대한의생명과학회지
    • /
    • 제17권3호
    • /
    • pp.225-230
    • /
    • 2011
  • Indirubin is the active ingredient of Danggui Longhui Wan, a mixture of plants that is used in traditional Chinese medicine to treat chronic diseases. In this study we investigated the anti-inflammatory effects of an indirubin derivative, indirubin-3’-monoxime-5-sulphonic acid (I3M-5S, $C_{16}H_{11}N_3O_5S$). We found that I3M-5S inhibits the production of various inflammatory mediators such as nitric oxide (NO) and prostaglandin $E_2$ ($PGE_2$) as well as inflammatory cytokines, tumor necrosis factor-${\alpha}$ and interleukin-6 in lipopolysaccharide (LPS) stimulated murine macrophage, RAW264.7 cells. In addition, the expression of inducible nitric oxide synthase and cyclooxygenase-2, which are essential enzymes to produce NO and $PGE_2$, respectively, was blocked by I3M-5S treatment in LPS-stimulated RAW264.7 cells. Present data suggest that I3M-5S exhibits potent anti-inflammatory activity in cultured macrophages and merit further study as potential therapeutic agents for inflammatory disorders.

줄기세포 연구의 현황과 의공학 기술과의 접목 (Current Status of Stem cell Research and its Connection with Biomedical Engineering Technologies)

  • 박용두
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권2호
    • /
    • pp.87-93
    • /
    • 2010
  • Researches for stem cells have been focused on scientists in biomedical sciences as well as clinical application for its great therapeutic potentials. Stem cells have two distinct characteristics: self-renewal and differentiation. In this short review, the links between stem cell research and biomedical engineering is discussed based on the basic characteristics of stem cells. This concept can be extended to the fundamental questions of biological sciences for cells such as proliferation, apoptosis, differentiation, and migration. For understanding proliferation and apoptosis of stem cells, techniques from biomedical engineering such as surface patterning, MEMS, nanotechnologies have been used. The advanced technologies such as microfluidic technologies, three dimensional scaffold fabrication, and mechanical/electrical stimulation have also been used in cell differentiation and migration. Basic and unsolved questions in the stem cell research field have limitations by studying conventional technologies. Therefore, the strategic fusion between stem cell biology and novel biomedical engineering field will break the barriers for understanding fundamental questions of stem cells, which can open the window for the clinical applications of stem cell based therapeutics as well as regeneration of damaged tissues.

임상병리과 학생을 대상으로 한 임상 실습에 관한 연구 (The Perception of Biomedical Laboratory Students on the Clinical Training)

  • 류재기;장철수
    • 대한임상검사과학회지
    • /
    • 제42권2호
    • /
    • pp.103-109
    • /
    • 2010
  • The aim of this study was to investigate the problem areas in the current clinical training of biomedical laboratory science education which may guide the development of an effective strategy for managing clinical training for biomedical laboratory science students. A self-reporting questionnaire was developed by the researchers. This survey was conducted between May 1st and May 15st in 2009 and 92 questionnaires were collected from senior biomedical laboratory science students. In Analyzing data, chi-square test was used for categorical variables. 82.6% of respondents was satisfied with conditions of the training institutes. 30~40% of the respondents reported that they were not satisfied with the programs and supervision systems for training students even though the staff members of other disciplines were supportive in general. Although 83.7% of the respondents reported that they were obtaining information and knowledge for their professional carrier through the training, 70.7% of the respondents reported that they had negative experiences during the training. According to the result of the survey, it can be inferred that the structure of the training education needs to be more systematically organized in order to train the well prepared entry-level biomedical laboratory scientists.

  • PDF

Treatment of Bone Repair by Inductively Magnetic Fields

  • 안재목;;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.213-217
    • /
    • 1992
  • An inductively coupled magnetical signal (pulse wave, 0.7 to 60Hz, eighteen volts peak to Peak) that was applied non-invasively on the skin surface overlying the approximate site(measure position). In the group with unipolar pulse signal currents produced smaller than in the group with bipolar pulse signal. The signal was transmitted to the active coil, including a time-varying magnetic field: this in turn induced a the-varying electrical field in the field in the bone. It is very important to determine system parameters due to treatment time(healing) and the simplicity. This paper investigation was designed to compare the relative effects of pulsed unipolar currents with the effects of an identical pulsed bipolar currents. Since Inductive coupling is non-invasive and involves portable equipment, it is easy to apply and requires precise localization, it has distinct advantages and field characteristics along the bone for each different signal.

  • PDF

Can We Estimate the LAP, RAP, PAP, AoP and CO from the Interventricular Pressure and Motor Current in a Moving- Actuator type Total Artificial Heart? Yes, We Can

  • 엄경식;안재목;박성근;조영호;최원우;최재순;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.59-63
    • /
    • 1997
  • It is needless to say that the hemodynamic variables estimation is a very important study for the artificial heart. Even though its importance there have not been satisfactory results which can be applied to the real-world situations. This paper surveys and recommends how to cope with the problem of hemodynamic variable estimation for the moving-actuator type total artificial heart (MA-TAH).

  • PDF

주파수 영역 분광법을 이용한 생체의 광학계수 측정법 연구 (Measurement of Optical Parameters of Biological Tissues by Using the Frequency-Domain Spectroscopy)

  • 전계진;윤길원;김홍식;김원기;이정한;박승한;김웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.379-382
    • /
    • 1997
  • A method for measuring optical properties of biological medium was investigated by using the frequency domain spectroscopy. When amplitude-modulated light with the frequency of several tens up to several hundred MHz propagates through a scattering medium, the phase lag and the amplitude reduction occur. The phase lag depends on the average of optical path lengths. The amplitude reduction with respect to the radial distance is influenced by the penetration depth. The mean of optical path length and penetration depth are related to optical coefficients. The phase lag and the amplitude reduction were measured based on the heterodyne detection method. The experimental data were fitted with the theoretical curves derived from diffusion theory and the absorption and scattering coefficients were calculated.

  • PDF

X-ray Sensitivity of Hybrid-type Sensor based on CaWO4-Selenium for Digital X-ray Imager

  • Park, Ji-Koon;Park, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권4호
    • /
    • pp.133-137
    • /
    • 2004
  • The development of digital x-ray detector has been extensively progressed for the application of various medical modalities. In this study, we introduce a new hybrid-type x-ray detector to improve problems of a conventional direct or indirect digital x-ray image technology, which composed of multi-layer structure using a CaWO$_4$ phosphor and amorphous selenium (a-Se) photoconductor. The leakage current of our detector was found to be ∼180 pA/cm$^2$ at 10 V/m, which was significantly reduced than that of a single a-Se detector. The x-ray sensitivity was measured as the value of 4230 pC/cm$^2$/mR at 10 V/m. We found that the parylene thin film between a CaWO$_4$ phosphor and an a-Se layer acts as an insulator to prevent charge injection from indium thin oxide (ITO) electrode into an a-Se layer under applied bias.

Three-Dimensional Porous Collagen/Chitosan Complex Sponge for Tissue Engineering

  • Kim, Sung Eun;Cho, Yong Woo;Kang, Eun Jung;Kwon, Ick Chan;Lee, Eunhee Bae;Kim, Jung Hyun;Chung, Hesson;Jeong, Seo Young
    • Fibers and Polymers
    • /
    • 제2권2호
    • /
    • pp.64-70
    • /
    • 2001
  • A three-dimensional, porous collagen/chitosan complex sponge was prepared to closely simulate basic extracellular matrix (ECM) constitutes, collagen and glycosaminoglycan. The complex sponge was prepared by a lyophilization method and had the regular network with highly porous structure, suitable for cell adhesion and growth. The pores were well interconnected, and their distribution was fairly homogeneous. The complex sponge was crosslinked using 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) to increase its boilogical stability and enhance its mechanical properties. The crosslinking medium has a great effect on the inner structure of the sponge. The homogeneous, porous structure of the sponge was remarkably collapsed in an aqueous crosslinking medium. However, the morphology of the sponge remained almost intact in a water/ethanol mixture crosslinking milieu. Mechanical properties of the collagen/chitosan sponge were significantly enhanced by EDC-mediated crosslinking. The potential of the sponge as a scaffold for tissue engineering was investigated using a Chinese hamster ovary cell (CHO-K1) line.

  • PDF

3D 내시경 영상처리를 위한 다중화기 설계와 부호화 성능평가 (Evaluation of Coding Performance and Design of Spatial Multiplexer or 3D Endoscopic Image Processing)

  • 송철규;이상민;이영묵;김원기;황종대;김정훈;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.137-141
    • /
    • 1997
  • In this study, in order to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery, three dimensional endoscopic system is designed. These 3D systems have our features of stereoendoscopic image processing: real time image capture and retrieve; presentation of left and right image on a single monitor; separable processing of the left and right eye images; coding of the 3D endoscopic video. For 3D endoscopic video coding, three approaches are presented based on interlaced picture structure, side-field format structure, and simulcast technique. Experimental results and performances comparisons are presented and analyzed or these approaches. Digital video coding techniques are presented or 3D endoscopic video sequences by means of an MPEG-2 video coding.

  • PDF