• Title/Summary/Keyword: biomedical

Search Result 13,438, Processing Time 0.053 seconds

Effects of Task-Oriented programme on Balance and Upper Extremity in stroke (과제 지향적 프로그램이 뇌졸중환자의 균형과 상지기능에 미치는 효과: 단일사례연구)

  • Kim, Eun-Joo;Hong, So-Young;Kim, Kyeong-Mi
    • Therapeutic Science for Rehabilitation
    • /
    • v.1 no.1
    • /
    • pp.17-28
    • /
    • 2012
  • Objective : The purpose of this study is to assess effects of task oriented programme on balance and upper extremity function in stroke patient. Methods : The subject is right hemiplegia with stroke and participated for 6 weeks. The design of study ABA designed of single subject research. The baseline phase consisted of 5 sessions. The intervention phase consisted of 15 sessions and performed task oriented training. The Maintenance phase consisted of 5 sessions. An assessment of upper extremity function was made using a Manual Function Test(MFT) and balance were assessed by the Time Up and Go test(TUG), Nintendo Wii Balance Board Test. Results : Dynamic balance improved from 51.53 to 42.62. At baseline, difference between left and right of the static balance was an average of 13.8, After treatment, the static balance difference was 6.29 and It was closer to zero than baseline, so static balance has been stable feature. Also, MFT point increased from 6 to 7.6. Conclusion : Task oriented programme can useful in balance and upper extremity function in stroke patient. Further studies need to generalize these findings.

Relationship Analysis of Osteoporosis and Body Mass Index(BMI) in the Middle-Aged Women (중년여성 골다공증과 체질량지수와의 관계 분석)

  • Lim, Jong-Duek;Jung, Jae-Eun;Park, Cheol-Woo;Dong, Kyung-Rae;Kim, Ho-Sung;Kim, Sun-Geun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.363-367
    • /
    • 2011
  • Generally, the osteoporosis of a middle-aged women have been reported that was a high risk in underweight, but the obese women have feasible osteoporosis. Therefor, the subjects were 120 middle-aged women that were diagnosed with osteoporosis in the bone mineral densitometer (BMD), this study was done for the purpose of analyzing the relationship between osteoporosis and body mass index (BMI) of the middle-aged women. We were determined BMI which was less than 18.5 underweight, 18.5 to 22.9 normal, 23.0 to 24.9 overweight, 25.0 to 29.9 obesity and extremely obesity were more than 30. When we examined the BMI distribution of the subjects, it was 2 women (1.7%) for underweight, 18 women (15.0%) for normal, 19 women (15.8%) for overweight, 75 women (62.5%) for obesity and 6 women (5.0%) for extremely obesity. Also, the relationship between osteoporosis and BMI of the subjects, it was the osteoporosis in 13 cases out of 18 (72.2%) with normal, in 14 case out of 19 (73.7%) with overweight, in 63 case out of 75 (84%) with obesity, in 5 case out of 6 (83.3%) with extremely obesity, besides, the osteoporosis usually marks the highest in a BMI with obesity. In conclusion, the result of analyzing the relationship between osteoporosis and BMI, we found out that the osteoporosis of the middle-aged women was high risk with obesity, and that was mostly higher the osteopenia rather than osteoporosis.

Study on Improvement of Signal to Noise Ratio for HgI2 Radiation Conversion Sensor Using Blocking Layer (Blocking layer 적용을 통한 HgI2 방사선 변환센서의 신호대 잡음비 향상에 관한 연구)

  • Park, Ji-Koon;Yoon, In-Chan;Choi, Su-Rim;Yoon, Ju-Sun;Lee, Young-Kyu;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using double layer technique tio decrease dark current. High efficiency material in substitution for a-Se have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using Hetero junction already used as solar cell, semiconductor. Particle-In-Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in PIB method. To make up for the weak points, double layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity is measured to evaluate double layer radiation sensor material.

The Measurement of Helper's Exposure Dose of nearby Radiographic Table in X-ray Examination (X선 촬영시 테이블 주변 촬영도움자의 피폭선량 측정)

  • Eun, Sung-Jong;Kim, Sung-Gil;Min, Byung-Woon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.415-420
    • /
    • 2011
  • The purpose of this study is to know the exposure dose nearby table on the general radiography(skull AP, chest PA, abdomen AP, lumbar lateral, hip joint, knee joint) and to find the reducing it. We measured beside the 45cm and 75cm table center, and 70cm, 80cm, 130cm, 150cm height from the bottom. That were measured highly from the radiography of lumbar lateral, abdomen AP and hip joint as followed $66.21{\mu}Sv$, $34.22{\mu}Sv$, and $32.35{\mu}Sv$ at the 80cm height beside 45cm from the center of table. Measured doses were reduced in order of chest PA, abdomen, hipjoint, skull, knee joint projection. It appears exposure dose of nearby radiographic table was extremely low amount compared with limit of dose(1mSv). If it protected by Pb apron, exposure dose of assisting person will not be exceed a limit of dose. Conclusively, Wearing apron is very important to avoid radiation from the general radiography.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Relative Evaluation for Biocompatibility of Pure Titanium and Titanium Alloys using Histological and Enzymatic Methods (조직학과 효소활성 방법을 이용한 순 타이타늄과 타이타늄 합금의 상대적인 생체적합성 평가)

  • Yeom, Dong-Sun;Kim, Byung-Il;Lee, Yu-Mi;Lee, Eun-Jung;Yee, Sung-Tae;Seong, Chi-Nam;Seo, Kwon-Il;Cho, Hyun-Wook
    • Toxicological Research
    • /
    • v.23 no.4
    • /
    • pp.331-339
    • /
    • 2007
  • Titanium or titanium alloy is a widely used implant material according to its certified biocompatibility, sufficient strength and ready availability. The purpose of this study was to evaluate the relative biocompatibility of titanium and titanium alloy specimens (Ti-29Nb-13Ta, TiNb and Ti-6Al-4V, Ti64) using in vivo and in vitro methods. For in vivo experiment, the specimens were implanted in the abdominal subcutaneous region of female mice for 2 and 4 weeks. The reaction of connective tissue to specimens was evaluated histologically. The specimens were encapsulated by fibrous connective tissue consisting of fibroblast, fibrocyte and other cells including neutrophil, macrophage, giant multinucleated cell and unidentified cells. Some newly formed blood vessels were located in the fibrous capsule surrounding the implant. Cell types and the thickness of fibrous capsules were examined quantitatively. Most of cell types located in the fibrous capsule were fibroblasts and fibrocytes. The average thickness of fibrous capsules for the TiNb specimens was much thinner than that of the titanium alloy, Ti64. The thickness of the fibrous capsule around all titanium specimens decreased at 4 weeks compared to 2 weeks post-implantation. The biocompatibility of titanium and titanium alloy specimens were also investigated in in vitro method using alkaline phosphatase from MG-63 cells. Alkaline phosphatase activity of the TiNb specimen showed higher activity than the titanium alloy, Ti64. In conclusion, the TiNb alloy with thin capsule thickness in vivo and high alkaline phosphatase activity in vitro will be of considerable use in biomedical applications.

Cytotoxicity and DNA Damage Induced by Magnetic Nanoparticle Silica in L5178Y Cell

  • Kang, Jin-Seok;Yum, Young-Na;Park, Sue-Nie
    • Biomolecules & Therapeutics
    • /
    • v.19 no.2
    • /
    • pp.261-266
    • /
    • 2011
  • As recent reports suggest that nanoparticles may penetrate into cell membrane and effect DNA condition, it is necessary to assay possible cytotoxic and genotoxic risk. Three different sizes of magnetic nanoparticle silica (MNP@$SiO_2$) (50, 100 and 200 nm diameter) were tested for cytotoxicity and DNA damage using L5178Y cell. MNP@$SiO_2$ had constant physicochemical characteristics confirmed by transmission electron microscope, electron spin resonance spectrometer and inductively coupled plasma-atomic emission spectrometer for 48 h. Treatment of MNP@$SiO_2$ induced dose and time dependent cytotoxicity. At 6 h, 50, 100 or 200 nm MNP@$SiO_2$ decreased significantly cell viability over the concentration of 125 ${\mu}g/ml$ compared to vehicle control (p<0.05 or p<0.01). Moreover, at 24 h, 50 or 100 nm MNP@$SiO_2$ decreased significantly cell viability over the concentration of 125 ${\mu}g/ml$(p<0.01). And treatment of 200 nm MNP@$SiO_2$ decreased significantly cell viability at the concentration of 62.5 ${\mu}g/ml$ (p<0.05) and of 125, 250, 500 ${\mu}g/ml$ (p<0.01, respectively). Furthermore, at 48 h, 50, 100 or 200 nm MNP@$SiO_2$ decreased significantly cell viability at the concentration of 62.5 ${\mu}g/ml$ (p<0.05) and of 125, 250, 500 ${\mu}g/ml$ (p<0.01, respectively). Cellular location detected by confocal microscope represented they were existed in cytoplasm, mainly around cell membrane at 2 h after treatment of MNP@$SiO_2$. Treatment of 50 nm MNP@$SiO_2$ significantly increased DNA damage at middle and high dose (p<0.01), and treatment of 100 nm or 200 nm significantly increased DNA damage in all dose compared to control (p<0.01). Taken together, treatment of MNP@$SiO_2$ induced cytotoxicity and enhanced DNA damage in L5178Y cell.

Study on the Relationship between Pro-Brain Natriuretic Peptide and Routine Blood Test Factors at a General Hospital in Gyeonggi-do (경기도 일개 종합병원에서 Pro-Brain Natriuretic Peptide와 통상적 혈액검사 인자간의 상관성 조사)

  • Park, Dong Yeop;Kim, Sang-Su;Sung, Hyun Ho;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.172-180
    • /
    • 2020
  • This study investigated retrospectively the correlation between the results of the N-terminal pro-brain natriuretic peptide (NT-proBNP) and a routine blood test using a hospital information system. The NT-proBNP is involved in the pathophysiology of heart failure. The results show that the relationship between age and NT-proBNP was significant (P<0.01) with a positive correlation (r=0.163). The peptide concentration showed a negative correlation between the total protein (r=-0.250) and albumin (r=-0.270), and a negative correlation between the erythrocyte count and hemoglobin and hematocrit (P<0.01). NT-proBNP had a positive correlation with neutrophils (r=0.227) and a negative correlation with lymphocytes (r=-0.236), showing significant results (P<0.01). NT-proBNP and creatinine showed a positive correlation (r=0.594, P<0.01), and it was the most influential factor according to multiple regression analysis (B=0.53, t=7.65). P<0.01). The concentrations of NT-proBNP and uric acid showed a positive correlation (r=0.180, P<0.05). Lactate dehydrogenase was observed as a factor affecting the NT-proBNP (B=0.20, t=3.28, P<0.01). This explanatory power had an influence of 43%. Therefore, the accurate test and related factors of the NT-proBNP have significant clinical value.

Survey on Sexually Transmitted Infection Test of One Referral Laboratory in Seoul: Focused on Multiple Sexually Transmitted Diseases (서울 소재 일개 수탁 검사 기관에서 성병 검사의 실태조사: 다발성 성매개 감염병 중심으로)

  • Seok, Dong-In;Sung, Hyun Ho;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.237-244
    • /
    • 2020
  • Currently, sexually transmitted diseases (STD) are referred to as "sexually transmitted infections" (STIs) in the sense of including asymptomatic infections. STIs have a range of interrelationships. This study used the STI defined by the Minister of Health and Welfare of the Republic of Korea, and targeted syphilis, gonorrhea, chlamydia infection, chancroid, genital herpes simplex, condyloma, human papillomavirus, and non-gonococcal urethritis. The factors were characterized by identifying multiple and simultaneous STIs. This study used the data from the laboratory information system of a consigned inspection institution located in Seoul from 2014 to 2019. In this study, multiple STIs were identified as overlapping STIs of a double infectious source (10 types) and multiple STIs of a third infectious source (6 types). Among the 16 types of multiple STIs, U. urealyticum (9 types), HSV-2 (8 types), C. trachomatis (7 types), HPV 6, 11 (7 types), N. gonorrhoeae (6 types), and T. pallidum (1 type) were included. Therefore, additional research on interrelationship studies, such as STIs, which has the highest proportion of multiple STIs, will be necessary.