• Title/Summary/Keyword: bi-directional current

Search Result 144, Processing Time 0.026 seconds

Development of 80kW Bi-directional Hybrid-SiC Boost-Buck Converter using Droop Control in DC Nano-grid (DC 나노그리드에서 Droop제어를 적용한 80kW급 양방향 하이브리드-SiC 부스트-벅 컨버터 개발)

  • Kim, Yeon-Woo;Kwon, Min-Ho;Park, Sung-Youl;Kim, Min-Kook;Yang, Dae-Ki;Choi, Se-Wan;Oh, Seong-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.360-368
    • /
    • 2017
  • This paper proposes the 80-kW high-efficiency bidirectional hybrid SiC boost/buck converter using droop control for DC nano-grid. The proposed converter consists of four 20-kW modules to achieve fault tolerance, ease of thermal management, and reduced component stress. Each module is constructed as a cascaded structure of the two basic bi-directional converters, namely, interleaved boost and buck converters. A six-pack hybrid SiC intelligent power module (IPM) suitable for the proposed cascaded structure is adopted for high-efficiency and compactness. The proposed converter with hybrid switching method reduces the switching loss by minimizing switching of insulated gate bipolar transistor (IGBT). Each module control achieves smooth transfer from buck to boost operation and vice versa, since current controller switchover is not necessary. Furthermore, the proposed parallel control using DC droop with secondary control, enhances the current sharing accuracy while well regulating the DC bus voltage. A 20-kW prototype of the proposed converter has been developed and verified with experiments and indicates a 99.3% maximum efficiency and 98.8% rated efficiency.

Improved Bi-directional Symmetric Prediction Encoding Method for Enhanced Coding Efficiency of B Slices (B 슬라이스의 압축 효율 향상을 위한 개선된 양방향 대칭 예측 부호화 방법)

  • Jung, Bong-Soo;Won, Kwan-Hyun;Jeon, Byeung-Woo
    • Journal of Broadcast Engineering
    • /
    • v.14 no.1
    • /
    • pp.59-69
    • /
    • 2009
  • A bi-directional symmetric prediction technique has been developed to improve coding efficiency of B-slice and to reduce the computational complexity required to estimate two motion vectors. On the contrary to the conventional bi-directional mode which encodes both forward and backward motion vectors, it only encodes a single forward motion vector, and the missing backward motion vector is derived in a symmetric way from the forward motion vector using temporal distance between forward/backward reference frames to and from the current B picture. Since the backward motion vector is derived from the forward motion vector, it can halve the computational complexity for motion estimation, and also reduces motion vector data to encode. This technique always derives the backward motion vector from the forward motion vector, however, there are cases when the forward motion vector is better to be derived from the backward motion vector especially in scene changes. In this paper, we generalize the idea of the symmetric coding with forward motion vector coding, and propose a new symmetric coding with backward motion vector coding and adaptive selection between the conventional symmetric mode and the proposed symmetric mode based on rate-distortion optimization.

Effect of Incidence Angle of Current on the Hydraulic Resistance Capacity of Clayey Soil (흐름의 입사각이 점성토 지반의 수리저항성능에 미치는 영향)

  • Kim, Young-Sang;Han, Byung-Duck;Kang, Gyeong-O
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.26-35
    • /
    • 2012
  • Until now, study on the hydraulic resistance characteristics of the ground at the river and the ocean current has been focused on the behavior under uni-directional flow without the direction change of flow. However, recent research result shows that scour rate which were measured under the bi-directional flow was much higher than those measured under uni-directional flow for both fine grained and coarse soil. Since the direction of inflow and return flow at the shore, where the structure will be constructed, is not always $180^{\circ}$, effect of the incidence angle on the hydraulic resistance capacity of the ground should be examined. Using the improved EFA which can consider the direction change of flow, hydraulic resistance capacities of the artificially composed clayey fine grained soil and clayey sandy soil under $0^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$ flow angle of incidence were assessed. Test result shows that hydraulic resistance capacity decreases and scour rate increase with the increase of the incidence angle between inflow and return flow. For the low consolidation pressure condition, hydraulic resistance capacity of the fine grained soil decreases rapidly. While the hydraulic resistance capacity of the coarse grained soil decreases more rapidly than fine grained soil under high consolidation pressure. Eventually since the larger the incidence angle between inflow and return flow, the larger the scour rate. Hydraulic resistance capacity under bi-directional flow($0^{\circ}{\longleftrightarrow}180^{\circ}$) should be examined for the design purpose.

A Soft Switching Bidirectional DC-DC Converter Using ZCT method (ZCT 방식을 이용한 양방향 소프트 스위칭 DC-DC 컨버터)

  • Lee, Il-Ho;Park, Kun-Wook;Jung, Doo-Yong;Kim, Jae-Hyung;Won, Chung-Yuen;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.479-480
    • /
    • 2010
  • In this paper, the bi-directional soft switching DC-DC converter using ZCT(Zero Current Transition) method is proposed for using battery application system. This topology is composed of soft switching bi-directional buck/boost converter having the ZCT auxiliary circuit with two switches, two resonant capacitors, one resonant inductor. Therefore, the proposed topology can reduce switching loss. To verify the validity of the proposed topology, theoretical analysis and simulation results are presented.

  • PDF

D-UPFC Application as the Series Power Device in the Massive Roof-top PVs and Domestic Loads

  • Lee, Kyungsoo
    • Current Photovoltaic Research
    • /
    • v.4 no.4
    • /
    • pp.131-139
    • /
    • 2016
  • This paper shows the series power device in the massive roof-top PVs and domestic loads. D-UPFC as the series power device controls the distribution voltage during voltage rise (or fall) condition. D-UPFC consists of the bi-directional ac-ac converter and the transformer. In order to verify the D-UPFC voltage control, the distribution model is used in the case study. D-UPFC enables the voltage control in the distribution voltage range. Dynamic voltage control from voltage rise and voltage fall conditions is performed. Scaled-down experimental test of the D-UPFC is verified the voltage control and it is well performed without high voltage spikes in the inductive load.

Intelligent simulation of the thermal buckling characteristics of a tapered functionally graded porosity-dependent rectangular small-scale beam

  • Shan, Xiaomin;Huang, Anzhong
    • Advances in nano research
    • /
    • v.12 no.3
    • /
    • pp.281-290
    • /
    • 2022
  • In the current research, the thermal buckling characteristics of the bi-directional functionally graded nano-scale tapered beam on the basis of a couple of nonlocal Eringen and classical beam theories are scrutinized. The nonlocal governing equation and associated nonlocal boundary conditions are constructed using the conservation energy principle, and the resulting equations are solved using the generalized differential quadrature method (GDQM). The mechanical characteristics of the produced material are altered along both the beam length and thickness direction, indicating that it is a two-dimensional functionally graded material (2D-FGM). It is thought that the nanostructures are defective because to the presence of porosity voids. Finally, the obtained results are used to design small-scale sensors and make an excellent panorama of developing the production of nanostructures.

Development of 500kW Tidal Current Energy Converter and Uldolmok Field Test (500kW 조류력 발전장치 개발 및 울돌목 실증시험)

  • Sim, Wooseung;Choe, Ickhung;Lee, Kyuchan;Kim, Haiwook;Bae, Jonggug;Min, Kehsik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.159.2-159.2
    • /
    • 2011
  • Hyundai Heavy Industries has developed a tidal current energy converter utilizing the accumulated technology as the world largest constructor for ship and offshore structures. The model has two sets of turbines in both ends in order to utilize the bi-directional current flows in flood and ebb tide. The torque produced by turbine in tidal current is directly delivered to generator along the horizontal axis, in which the turbine, gear, generator, gear and turbine are connected successively. The manufactured model for field test has the turbine diameter of 5 meters to produce the maximum power of 500kW at maximum current speed of 5m/s. The technical verification of tidal power converter was performed by means of small scale model test in towing tank as well as field test at the Strait of Uldolmok located in Jindo of Jeollanamdo province. Field test was performed by mounting the tidal current converter on the SEP(Self Elevating Platform) which could lower the 4 vertical legs on the seabed and could elevate platform over the water surface using the hydraulic power for itself. The field test performed for a month shows that power output is similar or larger compared with the expected one in design stage. This paper presents the development of tidal current energy converter and real sea field test by Hyundai Heavy Industries. This project has finished successfully and provided the technical advance toward commercial services for tidal current power generation in the south-west region in Korea.

  • PDF

Modeling and Current Controller Design of Integrated Charger (전기자동차용 통합충전기의 모델링 및 전류제어기 설계)

  • Heo, Geon;Park, Yongsoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.42-44
    • /
    • 2018
  • An integrated charger is used for bi-directional power conversion between an electric vehicle and a power grid. The proposed integrated charger works in a way that motor windings are utilized as filter inductances for charging/discharging of batteries in addition to the original purpose of motor drives. After a mathematical model of the integrated charger based on an dual winding induction machine (DWIM) is discussed, a current control method is designed for grid connection. The effectiveness of the proposed method is examined with simulation results.

  • PDF

Dynamic Voltage Compensation System Using Bi-directional DC/DC Converter of Electric Double-Layer Capacitor (EDLC의 양방향 DC/DC Converter를 이용한 동적 전압보상시스템)

  • Shon, Jin-Geun;Lee, Sang-Cheol;Lee, Gong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.108-111
    • /
    • 2007
  • A novel voltage sag compensator with hi-directional DC/DC converter of Electric double layer capacitor is proposed. Recently, the double-layer capacitor which is drawn attention as a new energy storage element has a lot of advantage such as no maintenance, long lifetime and quick charge/discharge characteristics with large current. This DC/DC converter is used to control the charging current to the double-layer capacitor and also used to keep the DC link voltage constant for discharge of the double-layer capacitor. Therefore, the proposed DC/DC converter has the high-efficiency controller, dynamic compensator of voltage sag is driven by this converter. Finally, experimental results show the validity of the control scheme and the ability of the dynamic voltage compensator.

  • PDF

An Implementation of a Current Controlled Bi-directional Inverter with ZVT Switching (ZVT 스위칭 되는 전류제어형 양방향 인버터의 구현)

  • 李 星 龍;高 晟 勳;金 成 佑
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.129-136
    • /
    • 2002
  • A single-phase inverter using a diode bridge-type resonant circuit to implement ZVT(Zero Voltage Transition) switching is presented. It Is shown that the ZACE(Zero Average Current Error) algorithm based Polarized ramptime current control can provide a suitable interface between DC link of diode bridge-type resonant circuit and the inverter. The current control algorithm is analyzed about how to design the circuit with auxiliary switch which can ZVT operation for the main power switch. The simulation and experimental results would be shown to verify the proposed current algorithm, because the main Power switch is turn on with ZVT and the hi-directional inverter is operated.