• 제목/요약/키워드: beta ray

검색결과 617건 처리시간 0.028초

Synthesis and characterization of poly(vinyl-alcohol)-poly(β-cyclodextrin) copolymer membranes for aniline extraction

  • Oughlis-Hammache, F.;Skiba, M.;Hallouard, F.;Moulahcene, L.;Kebiche-Senhadji, O.;Benamor, M.;Lahiani-Skiba, M.
    • Membrane and Water Treatment
    • /
    • 제7권3호
    • /
    • pp.223-240
    • /
    • 2016
  • In this study, poly(vinyl-alcohol) and water insoluble ${\beta}$-cyclodextrin polymer (${\beta}$-CDP) cross-linked with citric acid, have been used as macrocyclic carrier in the preparation of polymer inclusion membranes (PIMs) for aniline (as molecule model) extraction from aqueous media. The obtained membranes were firstly characterized by X-ray diffraction, Fourier transform infrared and water swelling test. The transport of aniline was studied in a two-compartment transport cell under various experimental conditions, such as carrier content in the membranes, stirring rate and initial aniline concentration. The kinetic study was performed and the kinetic parameters were calculated as rate constant (k), permeability coefficient (P) and flux (J). These first results demonstrated the utility of such polymeric membranes for environmental decontamination of toxic organic molecules like aniline. Predictive modeling of transport flux through these materials was then studied using design of experiments; the design chosen was a two level full factorial design $2^k$. An empirical correlation between aniline transport flux and independent variables (Poly ${\beta}$-CD membrane content, agitation speed and initial aniline concentration) was successfully obtained. Statistical analysis showed that initial aniline concentration of the solution was the most important parameter in the study domain. The model revealed the existence of a strong interaction between the Poly ${\beta}$-CD membrane content and the stirring speed of the source solution. The good agreement between the model and the experimental transport data confirms the model's validity.

Characterization of Microstructure and Mechanical Properties of Mg-8Li-3Al-1Y Alloy Subjected to Different Rolling Processes

  • Zhou, Xiao;Liu, Qiang;Liu, Ruirui;Zhou, Haitao
    • Metals and materials international
    • /
    • 제24권6호
    • /
    • pp.1359-1368
    • /
    • 2018
  • The mechanical properties and microstructure evolution of Mg-8Li-3Al-1Y alloy undergoing different rolling processes were systematically investigated. X-ray diffraction, optical microscope, scanning electron microscopy, transmission electron microscopy as well as electron backscattered diffraction were used for tracking the microstructure evolution. Tensile testing was employed to characterize the mechanical properties. After hot rolling, the $MgLi_2Al$ precipitated in ${\beta}-Li$ matrix due to the transformation reaction: ${\beta}-Li{\rightarrow}{\beta}-Li+MgLi_2Al+{\alpha}-Mg$. As for the alloy subjected to annealed hot rolling, ${\beta}-Li$ phase was clearly recrystallized while recrystallization rarely occurred in ${\alpha}-Mg$ phase. With regard to the microstructure undergoing cold rolling, plenty of dislocations and dislocation walls were easily observed. In addition, the microstructure of alloys subjected to annealed cold rolling revealed the formation of new fresh ${\alpha}-Mg$ grains in ${\beta}-Li$ phase due to the precipitation reaction. The mechanical properties and fracture modes of Mg-8Li-3Al-1Y alloys can be effectively tuned by different rolling processes.

알칼리 축전지의 활물질에 관한 연구(II)-니켈양극의 전기화학적 거동- (Studies on the Active Materials of Alkaline Storage Battery(II) Electrochemical Behavior of. Nickel Anode)

  • 주충렬;이주성
    • 한국표면공학회지
    • /
    • 제15권3호
    • /
    • pp.146-151
    • /
    • 1982
  • The electrochemical reaction behavior of nickel electrode of the nickel-cadium battery system in potassium hydroxide solution has been studied by cyclic voltammetry, controlled potential electrolysis and X-ray diffraction method. It has been found that the reaction mechanism of positive nickel electrode for charging was assumed to be proten transfer step with a rate controlling diffusion process and char-ging state of positive electrode was amorphous $\beta$-NiOOH.

  • PDF

TDEAT single source를 사용한 TiN막의 특성평가

  • 김재호;이재갑;박상준;신현국;황찬용
    • 한국진공학회지
    • /
    • 제4권S1호
    • /
    • pp.28-33
    • /
    • 1995
  • TiN 박막은 저온(<$500^{\circ}C$), 저압(1Torr)에서 Tetrakis(diethylamido)titanium[TDEAT, Ti(NEt2)4]single precursor를 사용하여 증착하였다. 증차고딘 박막은 SEM(Scanning Electron Microscopy)으로 surface morphology와 step coverage를 측정하였고, TEM(Transmission Electron Microscopy)분석결과 microcrystalline의 TiN을 확인하였다. XPS(X-ray Photoelectron Spectroscopy)분석결과에 따르면 $200-500^{\circ}C$구간에서는 $\beta$-hydogen elimination에 의한 반응이 일어나고 $600-700^{\circ}C$구간에서는 thermal decomposition에 의한 반응이 일어나고 있음을 알 수 있다. Carbon과 oxygen의 농도는 AES(Auger Electron Spectroscopy)를 사용하여 측정하였으며 온도가 감소할수록 carbon의 농도가 감소하는 경향을 보여주고 있다.

  • PDF

The Molecular Mechanical Model of DD-Peptidase

  • Lim, Eongjin;Won, Youngdo
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 1996년도 정기총회 및 학술발표회
    • /
    • pp.22-22
    • /
    • 1996
  • In order to establish the structural requirements for designing new ${\beta}$-lactam antibiotics it is necessary to build the molecular model of a penicillin binding protein. D-alanyl-D-alanine carboxypeptidase/transpeptidase (DD-peptidase) is a good model for PBPs. The X -ray crystallographic structure of DD-peptidase has been reported at the 1.6${\AA}$ resolution. (omitted)

  • PDF

PM10 연속자동측정기(β-ray) 등가성평가 및 비교관측 연구 (PM10 β-ray attenuation samplers (β-ray absorption method) equivalence evaluation and comparatively observed study)

  • 정원석;고희정;서원익;정지영;오상민;부경온
    • 한국입자에어로졸학회지
    • /
    • 제19권1호
    • /
    • pp.13-20
    • /
    • 2023
  • The Asian dust observation network operates β-ray attenuation samplers to measure PM10 concentrations. In addition, equivalence evaluation and accuracy inspection(Precision Tests) are conducted every year for the reliability of data. β-ray attenuation samplers(16 units) were comparatively observed from May to June 2020 and from July to December 2021. During the observation period, the average daily temperature was the lowest at 6.4℃ in December and the highest at 27.3℃ in August. The average daily humidity ranged from 60% to 100%, but the average daily humidity was over 75% from July to September. The minimum value of the PM10 Gravimetric method was 5.0 ㎍/m3, the maximum value was 53.4 ㎍/m3, and the average value was 17.8 ㎍/m3. The equivalence evaluation results of the PM10 Gravimetric method and β-ray attenuation samplers satisfied the criteria (slope: 1±0.1, intercept: 0±0.5). A relative error analysis between the PM10 Gravimetric method and β-ray attenuation samplers equipment showed that the relative error increased when the concentration was low and the temperature and humidity were high. In addition, in the β-ray attenuation samplers 5-minute interval observation data in May 2020, a relatively large Standard devication was shown as an average maximum ±23.4 ㎍/m3 and a minimum ±15.2 ㎍/m3. At standard deviations of 10% and 90%, equipment with high variability (deviation) was measured at 6 ㎍/m3and 61 ㎍/m3, and equipment with low variability was measured at 12 ㎍/m3 and 47 ㎍/m3. It was confirmed that concentration differences occurred due to differences in variability for each equipment.

MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가 (Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron)

  • 엄근용;박혜진;허순녕;예성준;이동한;박석원;우홍균
    • Radiation Oncology Journal
    • /
    • 제24권4호
    • /
    • pp.280-284
    • /
    • 2006
  • 목 적: 원자력의학원에 설치되어 있는 MC50 사이클로트론에서 생성되는 중성자선의 의학적 이용을 위하여 생물학적 특성을 평가하고자 하였다. 대상 및 방법: 35 MeV 양성자를 15 mm 베릴륨 표적에 부딪혀서 생성된 중성자선에 대하여 물리적 방사선선량을 측정한 후 체외실험(in-vitro)을 하였다. EMT-6 세포주(cell line)를 이용하여 $0{\sim}5\;Gy$의 중성자선을 조사 후 생존분획(surviving fraction)을 구하였다. 또한 감마선의 효과를 피하기 위하여 납차폐를 한 후에 동일 조건에서 생존분획을 구하였다. 엑스선 실험에서는 0, 2, 5, 10, 15 Gy를 조사 후 생존분획을 측정하였다. 결 과: MC50의 중성자선은 조사야 $26{\times}26\;cm^2$, 전류 $10{\mu}A$, 깊이 2 cm에서 84%의 중성자와 16%의 감마선으로 구성되어 있었고, 총선량률은 9.25 cGy/min이었다. 엑스선을 이용하여 측정한 생존분획곡선은 선형이차함수모델 (linear quadratic model)을 적용하였을 때 ${\alpha}/{\beta}$비는 0.611 (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$)이었다. 중성자선에 있어서 생존분획곡선은 저선량 영역에서 어깨영역(shoulder area)을 가지고 있었고, 모든 실험에서 선형이차함수모델에 잘 맞았다. ${\alpha}$의 평균값은 -0.315 (범위, $-0.254{\sim}-0.360$)였고, ${\beta}$값은 0.247 (범위, $0.220{\sim}0.262$)이었다. 납차폐를 하였을 때에도 생존분획곡선에서 어깨영역은 없어지지 않았다. 중성자선의 RBE (relative biological effectiveness) 값은 생존분획이 0.1일 때 $2.07{\sim}2.19$ 범위였고, 0.01일 때 $2.21{\sim}2.35$였다. 결 론: MC50에서 생성된 중성자선은 상당량의 감마선을 내포하고 있으며 이것이 생존분획곡선에서 어깨영역이 나타나는 데에 기여하였을 것이다. MC50의 중성자선의 RBE 값은 약 2.2였다.

휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발 (Development of a Portable Device Based Wireless Medical Radiation Monitoring System)

  • 박혜민;홍현승;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.150-158
    • /
    • 2014
  • 각 의료기관 내 방사선 관련 종사자나 방사선 치료환자들은 진단 및 치료 시 필연적으로 의료상 피폭을 수반하게 된다. 국제방사선방호위원회(ICRP) 권고나 국제원자력기구(IAEA)의 기준에 따라 기준선량 제약치를 적용 및 권고 받고 있지만 1차 피폭대상자인 종사자나 환자들의 피폭최적관리를 위해서는 잠재적인 피폭대상자들에게 기존의 피폭관리 시스템보다 직접적이고 가용성이 높은 측정 및 분석 방법이 필요하다. 따라서 본 연구에서는 기존에 구비된 휴대용 단말과 연동하여 원거리에서 실시간으로 방사선 모니터링이 가능한 시스템을 개발하였다. 모니터링 시스템은 검출부, 영상부, 통신부 세 부분으로 구성되었다. 검출부는 시스템의 소형화를 위해 실리콘 광증배소자(silicon photomultiplier) 기반 섬광검출기를 설계하였으며, 영상부는 무선 CCD (charge-coupled device)카메라 모듈을 사용하여 검출부와 함께 Bluetooth 통신모듈을 통해 휴대용 단말로 측정된 방사선 정보와 영상이 전송된다. 제작된 시스템은 성능 평가를 위해 진단용 X-ray 발생장치와 $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, $^{90}Sr$ 선원을 사용하였다. 측정결과를 통해 개발된 시스템은 gamma, beta, X-ray에 대해서 검출 반응성을 확인하였고, 방사선 세기에 따른 응답 선형성과 MCNPX 전산코드를 이용한 측정 거리에 따른 시스템의 검출 정확도 평가 시 3% 내외의 오차범위를 확인하였다. 본 연구의 결과는 방사선 검출 시스템 구성의 비용절감 효과와 개인피폭정도관리에 기여할 것으로 기대한다.

Nano-Mechanics 분석을 통한 질화 텅스텐 확산방지막의 질소 유량에 따른 연구 (Study of Tungsten Nitride Diffusion Barrier for Various Nitrogen Gas Flow Rate by Employing Nano-Mechanical Analysis)

  • 권구은;김성준;김수인;이창우
    • 한국진공학회지
    • /
    • 제22권4호
    • /
    • pp.188-192
    • /
    • 2013
  • 반도체 소자의 소형화, 고집적화로 박막의 다층화 및 선폭 감소로 인한 실리콘 웨이퍼와 금속 박막 사이의 확산을 방지하기 위한 많은 연구가 이루어지고 있다. 본 연구는 tungsten (W)을 주 물질로 증착시 nitrogen (N)의 유량을 2.5~10 sccm으로 변화시키며 증착된 확산방지막의 nano-mechanics 특성에 대해 연구하였다. 증착률, 비저항 및 결정학적 특성을 ${\beta}$-ray backscattering spectroscopy, 4-point probe, X-ray diffraction (XRD)을 이용하여 측정한 후 Nano-indenter를 사용하여 nano-mechanics 특성을 조사하였다. 그 결과 질소 가스 유량이 5 sccm 포함된 박막에서 표면 경도(surface hardness)는 10.07 에서 15.55 GPa로 급격하게 증가하였다. 이후 질소가스의 유량이 7.5 및 10 sccm에서는 표면 경도가 각각 12.65와 12.77 GPa로 질소 가스 유량이 5 sccm인 박막보다 표면경도가 상대적으로 감소하였다. 이는 박막 내 결정질과 비정질의 W과 N의 결합 비율의 차이에 의한 영향으로 생각되며, 또한 압축응력에 기인한 스트레스 증가가 원인으로 판단된다.

저농도 HF 수용액을 이용한 Al(OH)3의 표면처리 (Surface Treatment of Al(OH)3 using Dilute Hydrofluoric Acid Aqueous Solution)

  • 김도수;이철경;양동효
    • 한국세라믹학회지
    • /
    • 제39권3호
    • /
    • pp.315-320
    • /
    • 2002
  • 저농도로 희석된 HF 수용액(6 wt%)을 사용하여 $Al(OH)_3$의 표면을 F/Al의 몰비 0.15에서 처리하고, 처리 전후 표면특성을 관찰하였다. 반응계의 온도 및 pH 변화로부터 $Al(OH)_3$에 대한 HF의 표면반응은 HF와 접촉한 $Al(OH)_3$ 표면부에서 metastable한 ${\alpha}$형의 불화알루미늄$({\alpha}-AlF_3{\cdot}3H_2O)$이 안정한 ${\beta}$형의 불화알루미늄$({\beta}-AlF_3{\cdot}3H_2O)$으로 전이되는 과정으로 진행되며, 다량의 발열을 수반하면서 반응계의 온도상승을 유발하였다. 이러한 ${\beta}-AlF_3{\cdot}3H_2O$의 생성은 표면처리된 분말의 FT-IR 및 X-선 회절분석결과를 통해 확인되었다. ${\beta}-AlF_3{\cdot}3H_2O$의 morphology와 분포상태를 SEM을 통해 관찰한 결과 $Al(OH)_3$ 표면에 $1{\mu}m$ 이하의 미세분말 형태로 피복층을 형성하며 균일하게 분포된 것으로 확인되었다. HF로 처리된 시료의 표면 백색도는 미처리에 비해 약 6.6% 증가되었으며, 이는 $Al(OH)_3$보다 높은 백색도를 지닌 ${\beta}-AlF_3{\cdot}3H_2O$ 피복 효과 때문인 것으로 나타났다.