• Title/Summary/Keyword: bed change

Search Result 678, Processing Time 0.028 seconds

Selective Catalytic Reduction of Nitric Oxide over Metal Exchanged ZSM-5 Catalysts (금속을 이온교환시킨 ZSM-5 촉매 상에서 Nitric Oxide의 환원반응)

  • Ahn, Sung-Hwan;Kim, Tae-Ok;Hahm, Hyun-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2000
  • The selective catalytic reduction(SCR) of nitric oxide by ethane in the presence of oxygen was investigated on Cu-ZSM-5, Co-ZSM-5 and Ga-ZSM-5 catalysts over a range of 400, 450 and $500^{\circ}C$. The catalysts were prepared by ion-exchange method. The composition of the reactant gases were 1000 ppm of NO, 1000 ppm of $C_{2}H_{6}$ and 2.5% of $O_{2}$, and the reaction was conducted in a fixed-bed reactor at 1 atm. For the 20wt% Co-ZSM-5(50) catalyst, the NO conversion reached up to 100%, while the $C_2H_6$ conversion and the CO selectivity were about 50% and 25%, respectively, at $450^{\circ}C$. For the 20wt% Cu-ZSM-5(50) catalyst, the NO conversion and the C2H6 conversion were about 80% and 100%, respectively, but there was no CO produced. The metal ion-exchanged ZSM-5 catalysts exhibited a tendency to increase the NO conversion with the Si/Al ratio of the ZSM-5, that is, NO conversion was inversely proportional to the acidity of the catalysts. But, the effect of the acidity on NO conversion was not so large. From the XRD results of the catalysts before and after SCR reaction it was found that there was no structural change.

Single Stage Circumferential Cervical Surgery (Selective Anterior Cervical Corpectomy with Fusion and Laminoplasty) for Multilevel Ossification of the Posterior Longitudinal Ligament with Spinal Cord Ischemia on MRI

  • Son, Seong;Lee, Sang-Gu;Yoo, Chan-Jong;Park, Chan-Woo;Kim, Woo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.335-341
    • /
    • 2010
  • Objective : Anterior cervical corpectomy with fusion (ACF) or laminoplasty may be associated with substantial number of complications for treating multilevel cervical ossification of the posterior longitudinal ligament (OPLL) with significant cord compression. For more safe decompression and stabilization in multilevel cervical OPLL with prominent cord compression, we propose circumferential cervical surgery (selective ACF and laminoplasty) based on our favorable experience. Methods : Twelve patients with cervical myelopathy underwent circumferential cervical surgery and all patients showed multilevel OPLL with Signal change of the spinal cord on magnetic resonance imaging (MRI). A retrospective review of clinical, radiological. and surgical data was conducted. Results : There were 9 men and 3 women with mean age of 56.7 years and a mean follow up period of 15.6 months. The average corpectomy level was 1.16 and laminoplasty level was 4.58. The average Japanese Orthopedic Association score for recovery was 5.1 points and good clinical results were obtained in 11 patients (92%) (p < 0.05). The average space available for the cord improved from 58.2% to 87.9% and the average Cobb's angle changed from 7.63 to 12.27 at 6 months after operation without failure of fusion (p < 0.05). Average operation time was 8.36 hours, with an estimated blood loss of 760 mL and duration of bed rest of 2.0 days. There were no incidences of significant surgical complications, including wound infection. Conclusion : Although the current study examined a small sample with relatively short-term follow-up periods, our study results demonstrate that circumferential cervical surgery is considered favorable for safety and effectiveness in multilevel OPLL with prominent cord compression.

Flood Stage Analysis and Prediction of River Bed Change for Stream Corridor Restoration Model with River Vegetation (하천식생 복원모형의 홍수위 분석과 하상변동 예측)

  • Song, Joong-Geun;Kim, Byeong-Chan;Lee, Jong-Seok
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.437-441
    • /
    • 2009
  • The modern times is as special as from the river, the river is very important of our life. The importance to preserve the river environment has been issued and the river developing method is being changed to use potential function of nature as well as flood control. Essential element of the river restoration is a vegetation. The flow resistance by vegetation along the river banks is greatly increase the flood stage. Therefore, the flow resistance due to vegetation in the river and roughness coefficient changes to understand the hydraulic characteristics is an important elements in the river restoration. The purpose of this study is to analyze the flood stage and the aspects of riverbed changes due to the corridor restoration with river vegetation. In order to simulate the flood stage and riverbed changes, HEC-RAS, RMA-2, and SED-2D model were applied for the upstream and downstream in study reaches, respectively.

  • PDF

The Structural Relations of leadership Type, Job Satisfaction, and Organizational Commitment in Healthcare Organizations (보건의료 조직에서 리더십 유형, 직무만족, 조직몰입 간의 구조적 관계 : 간호 및 행정직을 중심으로)

  • Jung, Min-Soo;Lee, Bo-Hye;Choi, Man-Kyu
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.3
    • /
    • pp.49-58
    • /
    • 2009
  • Healthcare organizations need mutual cooperation among various medical professionals in order to carry out the performance of their duties spite of haying a strong job specialization and independence based on license. However, spite of the importance of leadership roles, there have not been enough researches dealt with leadership effect under the complex duties' relationship of a healthcare organization. This study suggested a new model by combining characteristics of leadership style, job satisfaction, and organizational commitment using Structural Equation Model (SEM). The data were self-administered questionnaires collected in 2006 from 437 employees (nurses, medical technicians, and administrative staffs) of 5 hospitals located in Seoul. The items of questionnaire were composed as a method of choosing new leadership style based on the Bass's standardized questionnaire on a Iransactionaljtransformational leadership combining the Leader Behavior Description Questionnaire-XII (LBDQ-XII) of the Ohio State University and Graen and Uhl-Bien's LMK scale through simulation techniques responding to organizational commitment. As a result, the leadership style increasing employees' self-confidence and having continuous response relationship between managers and employees improved their discretion and empowerment as well as worthwhileness and pride. However, the leadership style emphasizing reward and a sense of duty brought about a bed result that was not able to effectively respond to employees' discretion and empowerment and even weakened their worthwhileness and pride. After all, the leadership style based on vision and change had an effect on organizational commitment but the other one based on reward and a sense of duty seemed to be unsuccessful in organizational commitment. Therefore, the desirable leadership in a healthcare organization should be based on employees' self-confidence and continuous response relationship between managers and employees.

A Sensitivity Analysis about Solar Heat Gain and Heating Load of ZeSH According to Optical Characteristics of Window system (창호의 광학적 특성에 따른 ZeSH의 일사취득 및 난방부하에 관한 민감도 분석)

  • Son, Sun-Woo;Baek, Nam-Choon;Suh, Seung-Jik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.66-71
    • /
    • 2009
  • To reduce the building energy consumption, the major advanced nations are conducting actively many researches on so called a "self-sufficient building(or other words zero energy building)" which can support its required energy by itself. Given this background, KIER(Korea Institute of Energy Research) built full size test-bed of the zero energy solar house in early 2002, and has studied on the self-sufficient heating load up to now. We analyse the sensitivity between the heating load and the solar radiation gain according to the change the effective transmittance of windows. The authors classified 9 cases by solar transmittance of glass. The results demonstrate the solar radiation amount is 0.466 MWh from the eastern zone of Fl.,1(the first floor), 0.332 MWh from Fl.,2(the second floor), 1.194 MWh form the southern zone of F1., and 0.822 MWh from the southern zone of Fl.,2 on the case 1(each cases are classified by window types). On the case 9, the solar radiation amount is 3.127 MWh, 2.662 MWh, 8.799 MWh and 6.078 MWh from the same condition. For the Fl.,1, the amount of Heat Load that is saved per year ranged 10.5 to 48 %, and the reduction was anywhere from 0.2 to 17.9% for Fl.,2

  • PDF

A study on the Associations between life style of Obese Patients and Sasang Constitutions (비만인(肥滿人)의 생활행태(生活行態)와 사상체질(四象體質)의 상관성(相關性)에 관(關)한 연구(硏究))

  • Kim, Eun-young;Kim, Jong-won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.11 no.1
    • /
    • pp.185-199
    • /
    • 1999
  • Purpose Obesity goes on increasing rapidly because of the change of dietary life, various stresses and convenience of life, that cause heart disease, diabetes mellitus, hypertension, fatty liver, arteriosclerosis these days. As obesity is disease, I think there will be constitution to easily become obese, so I began to study this. Methods (1) Subjects The subjects of this study were 101 female patients visited Nara oriental medical hospital during 2months from April 1 to May 30 in 1999. (2) I determined finally classification of sasang constitution according to diagnosis and questions made in Nara oriental medical hospital. Results (1) 81.2% of obese patients are Taeumin, 15.8% of those are Soeumin, 3% of those are Soyangin. (2) Soeumin has significant difference that it takes over 30 minutes to have a meal. (3) Significant difference is that Soeumin goes to bed earlier in the evening than Taeumin and Soyangin. (4) From obesity of whole body point of view, Taeumin has more significant and from obesity of abdomen and leg point of view, Soeumin has more significant difference.

  • PDF

Analysis of the hydraulic structure of geometric shape according to sediment transportation and bed change characteristic (수공구조물 설치에 따른 유사확산 및 하상변동 특성에 관한 분석)

  • Ahn, Seung-Seop;Song, In-Ryul;Lee, Hyo-Jung;Lee, Nam-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.963-966
    • /
    • 2008
  • 본 연구에서는 최근까지 유사관측을 수행하고 있는 금강본류 하도구간의 금남$\sim$공주 지점을 대상으로 하였다. 분석을 위하여 이 지점의 총유사량 산정에 영향을 미치는 부유사량 관측 및 수위, 유량과 같은 하천 흐름 등에 관한 과거의 자료를 수집 정리 하였다. 본 연구에서 적용하고자 하는 교량의 교각에 대한 기하학적 형상은 원형, 정사각형, 정팔각형, 장방형으로 하였으며 분석 모형은 SED2D-WES 모형을 이용하여 유역에 대한 교각의 형상이 미치는 영향에 대하여 연구 하였다. 그 결과 지름이 6m, 경간장 57m인 원형교각의 경우 교각에서 약 14.3m 떨어진 곳에서 최고 유속 0.75m/s가 발생되었으며, $6{\sim}6m$의 정사각형교각의 경우 교각으로부터 약 15.8m떨어진 곳에서 0.68m/s의 최대 유속이 발생하고 $6{\sim}6m$ 정팔각형교각의 경우 교각으로부터 약 16.2m떨어진 곳에서 0.65m/s의 최대유속이 발생하고, 마지막으로 $3{\sim}6m$ 장방형교각의 경우 교각으로부터 약 21m 떨어진 구간에서 0.63m/s의 최고 유속이 발생하는 것으로 나타났다. 대상유역의 길이가 길고, 유속이 낮으므로 유출지점까지 흘러내려가는 유사량보다 하천내에 유입된 유사가 그대로 퇴적되는 경우가 많아 24시간 분석결과 하상변동량은 퇴적량과 침식량을 합하여 약 0.22%정도 변동되는 것으로 나타났으며, 교각형상에 따른 하상변동특성으로 원형교각의 경우 세굴이 일어나는 지점은 교각에서 약 16.88m떨어진 지점까지 하상변동이 일어났으며, 정사각형 교각의 경우 교각에서 약 10.96m떨어진 지점까지, 정팔각형 교각의 경우 교각에서 약 6.32m떨어진 지점까지, 장방형 교각의 경우 교각에서 약 18.23m떨어진 지점까지 하상변동이 나타남을 알 수 있었다.

  • PDF

Application of GSTARS and HEC6 for Long-term Prediction of Bed Change in Hyungsan River (형산강의 장기하상변동예측을 위한 GSTARS와 HEC6의 적용)

  • Ahn, Jung-Min;Lyu, Si-Wan;Lee, Nam-Joo;Yeo, Hong-Goo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.958-962
    • /
    • 2008
  • 하천유황, 하상재료, 하도지형의 자연적 또는 인위적 변화에 의한 장 단기적 하상변동의 해석 및 예측은 하천계획 및 관리를 위해 필수적이다. 특히, 제방 축조 등의 인위적 정비로 충적층 발달이 미약한 우리나라 하천은 상대적으로 종단형의 변화가 중요한 문제로 등장하였다. 하천의 이수, 치수 및 환경기능에 복합적으로 영향을 미치는 장기적인 하상변동 예측을 국가하천 형산강에 대해여 HEC6 모형과 GSTARS 모형을 이용하여 수행하였다. 본 연구에서는 $2006{\sim}2007$년 동안 형산강에서 직접 실측한 유량-유사량, 하상토, 하천측량자료를 GSTARS와 HEC6 모형에 적용하여 장기 하상변동을 모의하고 그 결과 값을 비교 분석하였다. 수위표 지점인 형산교(모아), 강동대교(안강), 국당2교(부조), 신형산교(대송)를 내부경계조건으로, HEC-RAS를 통하여 조도계수 값을 보정하였으며 유량 값은 유황곡선을 통하여 연간유입량을 각 날짜별로 구성하였다. 모형의 검증은 Laursen (1963), Laursen (Modified by Maddden, 1985), Laursen (Modified by Copeland, 1990), Yang (1973) 공식을 이용하여 최심하상고 변화량 제곱근 오차가 가장 작은 공식을 선정하였다. 2006년 형산강에서 실측된 하천측량자료를 이용하여 14년간 장기하상을 모의해 본 결과 형산강 유역에서는 Laursen (Modified by Copeland, 1990, HEC6)와 Laursen (1958, GSTARS)공식이 가장 작은 오차를 나타내었으며 HEC6와 GSTARS는 하상변동의 경향을 잘 나타내었다. 형산강의 전반적인 하상변동 경향은 상류지역은 전반적으로 하상이 저하하였고 하류지역은 하상이 상승하였다. 또한 하류부는 하상이 안정화를 이루고 있어 변화가 적은 것으로 판단된다. 하지만 검증 기간 동안의 골재채취와 보의 설치 등의 외부 여건과 신뢰성 있는 유입유량을 반영하지 못하였기 때문에 보다 나은 결과를 얻기 위해서는 지속적인 유량-유사량의 관측과 자료의 보완 및 정밀 조사 분석이 필요하다.

  • PDF

Numerical Modelling of the Adjustment Processes of Minning Pit in the Dredged Channels (수치모의를 이용한 준설하천의 웅덩이 적응에 관한 연구)

  • Jang, Chang-Lae
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.10
    • /
    • pp.921-932
    • /
    • 2010
  • In this study, the adjustment processes of the disturbed channels by sand or gravel mining were investigated by a two dimensional numerical model in the generalized coordinate system. As a numerical scheme, the CIP (cubic interpolated pseudoparticle method) method was used to calculate the advection term in the flow field and central difference method was used to the diffusion term in it. The pit of the channel was partially filled with sediment at the toe of the pit upstream. As time increased, the headcut erosion upstream in the pit was decreased due to the sediment inflow. The almost inflow sediment upstream was trapped into the pit and the sediment deposit wedge migrated downstream in the pit with the steep submerged angle of repose. The numerical model was reproduced well the evolution processes of the channel. The mining pit migrated with speed as the channel was steep, and the numerical results were in overall agreement with the experimental results.

Characteristics of treatment by Electrolysis with a change of electrodes in sanitary landfill leachate (전기분해법에서의 전극변화에 따른 위생매립장 침출수의 처리특성)

  • Huh, Mock;Kim, Byung-Hyun;Kim, Gwang-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.1
    • /
    • pp.68-74
    • /
    • 2002
  • This study was performed to examine the availability of electrolysis for removal of remaining biologically refractoty humus and residual color of leachate which is biologically pretreated in domestic waste matter sanitary landfill by recycling to landfill. The obtained results were as follows; 1) The electrolysis of leachate through covered bed represented that the removal efficiency of CODcr and color range from 70~80%, in color removal the only electrolysis for a treatment of leachate meet the critia of effluent. 2) The highest removal efficiency was represented in pH 7~8. 3) At anode used Al, Fe, Stainless the removal efficiency of CODcr and color was high in order of Fe, Al, stainless, in considering the settled ability of reaction product in economic or after electro coagulation the removal efficiency was highest when anode was the Fe electrode. 4) In this study conditions for removed both CODcr and Color ar the same time represented thar anode was used Fe, electrode-distance was 2cm and reaction time was 40min in 8volts.

  • PDF