• Title/Summary/Keyword: bearing wall system

Search Result 112, Processing Time 0.026 seconds

Experimental Evaluation of PC Non-Bearing Wall System for the Damage Control of RC Wall Type Apartments (RC 벽식 아파트의 손상 제어를 위한 PC 비내력벽 시스템의 실험적 평가)

  • Moon, Kyo Young;Kim, Siyun;Kim, Sung Jig;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.4
    • /
    • pp.77-84
    • /
    • 2019
  • This study introduces a newly developed PC non-bearing wall system to prevent the damage of RC wall-type apartments that have been heavily damaged by the 2017 Pohang Earthquake. In order to evaluate the performance of the developed PC non-bearing wall system, a static cyclic test is conducted. The prototype of test specimen is from the RC wall-type apartment which has been severely damaged by the 2017 Pohang Earthquake. The specimen with the conventional non-bearing wall system showed the similar damage of RC wall type apartment suffered from the Pohang Earthquake. In case of the specimen with the developed PC non-bearing wall system, cracks and damages were not transmitted between the walls due to the seismic slit and there were almost no cracks in the non-bearing walls. Therefore, the proposed non-bearing wall system, separated from the structural walls, could prevent spreading cracks to bearing walls and make it possible to effectively control damage due to earthquake loads.

The Bearing Strength of Connections Between Steel Coupling Beam and Reinforced Concrete Shear Walls

  • Yun, Hyun Do;Park, Wan Shin;Han, Min Ki;Kim, Sun Woo;Kim, Yong Chul;Hwang, Sun Kyung
    • Architectural research
    • /
    • v.7 no.1
    • /
    • pp.27-38
    • /
    • 2005
  • No specific guidelines are available for computing the bearing strength of connection between steel coupling beam and reinforced concrete shear wall in a hybrid wall system. There were carried out analytical and experimental studies on connection between steel coupling beam and concrete shear wall in a hybrid wall system. The bearing stress at failure in the concrete below the embedded steel coupling beam section is related to the concrete compressive strength and the ratio of the width of the embedded steel coupling beam section to the thickness of the shear walls. Experiments were carried out to determine the factors influencing the bearing strength of the connection between steel coupling beam and reinforced concrete shear wall. The test variables included the reinforcement details that confer a ductile behavior in connection between steel coupling beam and shear wall, i.e., the auxiliary stud bolts attached to the steel beam flanges and the transverse ties at the top and the bottom steel beam flanges. In addition, additional test were conducted to verify the strength equations of the connection between steel coupling beam and reinforced concrete shear wall. The proposed equations in this study were in good agreement with both our test results and other test data from the literature.

Experimental Study on the Seismic Response of High-Rise RC Bearing-Wall Structures with Irregularity (고층 RC 벽식 비정정 구조물의 지진거동에 관한 실험적 연구)

  • 이한선;고동우
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.321-328
    • /
    • 2003
  • The objective of this study is to investigate the seismic response of high-rise RC bearing-wall structures with irregularity. For this purpose, three 1:12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames have three different layouts of the plan : The first one is a moment-resisting frame system, the second has a infilled shear wall with symmetric plan and the third has a infilled shear wall with eccentricity, Then, these models were subjected to a series of earthquake excitations. The test results show the followings: 1) the existence of shear wall reduced greatly shear deformation at the piloti frame, but has almost the negligible effect on the reduction of the overturning-moment angle, 2) the frame with shear wall resists most of overturning moment in severe earthquake, 3) the torsional behavior is almost independent of the translational, 4) the absorbed energy due to the overturning deformation has the largest portion in the total absorbed energy.

  • PDF

Post Evaluation on the Constructibility of the Lightweight Wall in Long Life Housing through Interview Survey (설문조사를 통한 장수명주택의 경량벽체 시공성 사후평가)

  • Lee, Hak-Ju
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.188-189
    • /
    • 2014
  • Recently, structural system of apartment building is changing from wall type to column type to accommodate various life styles of residents in Korea. Reinforced-concrete bearing wall structures have been mainly used in apartment construction since 1980's. It is impossible to remove the bearing wall in case of remodeling a house, so that the lightweight wall is needed to apply to the column type structure of the Long Life Housing. Therefore, the purpose of this study is to evaluate the construction performance of the wall. Constructibility reviews are performed throughout interview survey from builders who charge with managing the construction of the lightweight wall in field. This paper present that constructor prefer the bearing wall rather than the lightweight wall because of the schedule delay, difficulty of management, and lack of skilled labor. The results indicate what we should improve on the lightweight wall from now on.

  • PDF

Structural performance of reinforced concrete wall with boundary columns under shear load

  • Chu, Liusheng;He, Yuexi;Li, Danda;Ma, Xing;Cheng, Zhanqi
    • Structural Engineering and Mechanics
    • /
    • v.76 no.4
    • /
    • pp.479-489
    • /
    • 2020
  • This paper proposed a novel form of reinforced concrete (RC) shear wall confined with boundary columns. The structural effect of applying steel fiber reinforced concrete (SFRC) in the wall-column systems was studied. Three full-scale wall samples were constructed including two RC wall-RC column samples with different stirrup ratios and one RC wall-SFRC column sample. Low frequency cyclic testing was carried out to investigate the failure modes, hysteretic behavior, load-bearing capacity, ductility, stiffness degradation and energy dissipation. ABAQUS models were set up to simulate the structural behavior of tested samples, and good agreement was achieved between numerical simulation and experimental results. A further supplementary parametric study was conducted based on ABAQUS models. Both experimental and numerical results showed that increasing stirrup ratio in boundary columns did not affect much on load bearing capacity or stiffness degradation of the system. However, applying SFRC in boundary columns showed significant enhancement on load bearing capacity. Numerical simulation also shows that the structural performances of RC wall-SFRC column system were comparable to a wall-column system fully with SFRC.

Coordinated supporting method of gob-side entry retaining in coal mines and a case study with hard roof

  • Liu, X.S.;Ning, J.G.;Tan, Y.L.;Xu, Q.;Fan, D.Y.
    • Geomechanics and Engineering
    • /
    • v.15 no.6
    • /
    • pp.1173-1182
    • /
    • 2018
  • The coal wall, gob-side backfill, and gangues in goaf, constitute the support system for Gob-side entry retaining (GER) in coal mines. Reasonably allocating and utilizing their bearing capacities are key scientific and technical issues for the safety and economic benefits of the GER technology. At first, a mechanical model of GER was established and a governing equation for coordinated bearing of the coal-backfill-gangue support system was derived to reveal the coordinated bearing mechanism. Then, considering the bearing characteristics of the coal wall, gob-side backfill and gangues in goaf, their quantitative design methods were proposed, respectively. Next, taking the No. 2201 haulage roadway serving the No. 7 coal seam in Jiangjiawan Mine, China, as an example, the design calculations showed that the strains of both the coal wall and gob-side backfill were larger than their allowable strains and the rotational angle of the lateral main roof was larger than its allowable rotational angle. Finally, flexible-rigid composite supporting technology and roof cutting technology were designed and used. In situ investigations showed that the deformation and failure of surrounding rocks were well controlled and both the coal wall and gob-side backfill remained stable. Taking the coal wall, gob-side backfill and gangues in goaf as a whole system, this research takes full consideration of their bearing properties and provides a quantitative basis for design of the support system.

Finite Element Analytical Study of Steel Plate and Dowel Bar Systems Designed for Damage Reduction of Non-Bearing Walls (비내력벽의 손상제어를 위한 Steel Plate와 Dowel Bar 이격시스템에 대한 유한요소해석)

  • Lim, Chang-Gue;Moon, Kyo Young;Lee, Hong-Seok;Kim, Sung Jig;Kim, Young Nam;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.123-130
    • /
    • 2020
  • Generally the non-bearing walls in apartment buildings in Korea are not considered as a lateral force resisting members for the design consideration. This engineering practice caused large crack damages and brittle fractures of the non-bearing walls when subjected to Pohang earthquakes in 2017 since those have not been designed for seismic loading. In this study, finite element analysis was conducted for slot type non-bearing wall connection system to reduce damages and concentrate damages to the designated damping device through separation from the structural wall members. Steel plate and dowel bar systems designed for the dissipation of seismic energies were modeled and analyzed to investigate the damage reductions. Finally, the test result and the analysis result were compared and verified.

The Application of MHS Frames for Apartments of Extended Life in Korea (공동주택 장수명화를 위해 MHS 공법이 적응된 골조공법 개선방안)

  • Hong, Won-Kee;Kim, Jin-Min;Kim, Sun-Kuk;Kim, Hyung-Geun;Yoon, Ki-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.107-115
    • /
    • 2008
  • Bearing wall apartments have been introduced to meet the needs of population growth in metropolis since 1980 in Korea. It is extremely difficult to remodel bearing wall apartments. Noises and vibrations generated between floors are also problems to solve. This paper introduces rahmen structures that enable easy remodel. Modularized Hybrid System(MHS) is demonstrated to be effective in terms of material quantity, construction costs, and amount of $CO_2$ emission compared with those of bearing wall structures. Housings with MHS composite girder ensure the flexibility of architectural plan and easy remodel while the floor heights are maintained the same as bearing wall structures. The reduction of the concrete and reinforcing steels tonnage decreased construction cost of MHS multi-residential housings. The $CO_2$ omission was also diminished in accordance with the reduction of construction materials. This paper describes new structural system adapting MHS frames to propose the extended life of residential housings and reduce the national resources by preventing unnecessary rebuilding of housings.

Seismic Behavior of Steel Coupling Beam-Wall Connection with Pane Shear Failure (패널파괴형 철골 커플링 보-벽체 접합부의 내진거동)

  • Park Wan-Shin;Han Min-Ki;Kim Sun-Woo;Hwang Sun-Kyung;Yang Il-Seung;Yun Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.431-434
    • /
    • 2005
  • In the past decade, various experimental programmes were undertaken to address the lack of information on the interaction between steel coupling beams and reinforced concrete shear wall in a hybrid coupled shear wall system. In this paper, the seismic performance of steel coupling beam-wall connections in a hybrid coupled shear wall system is examined through results of an experimental research programme where three 2/3-scale specimens were tested under cyclic loading. The test variables included the reinforcement details that confer a ductile behaviour on the steel coupling beam-wall connection, i.e., the face bearing plates and the horizontal ties in the panel region of steel coupling beam-wall connections. Panel shear strength reflects enhancement achieved through mobilization of the reinforced concrete panel using face bearing plates and/or horizontal ties in the panel region of steel coupling beam-wall connections.

  • PDF

Behavior of Three Story Bearing Wall Structure under Lateral toad Reversals (반복 수평하중을 받는 3층 철근콘크리트 내력벽 아파트 구조물의 거동 특성)

  • Chang Kuk-Kwan;Oh Young-Hun;Kim Ki-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.627-634
    • /
    • 2004
  • The purpose of this study is to investigate seismic performance of a bearing wall system for apartment buildings. An 1/3 scale three-story specimen was constructed and tested under cyclic lateral loads. The specimen was consisted of pierced walls and coupling elements as well as floor slabs. The bearing wall system is considered to have a adequate deformation capacity up to $2.0\%$ of roof drift ratio, and the experimental results showed the ductile load-deformation characteristics even though some walls were failed in shear Nonlinear analysis was peformed to compare the load-deformation curve obtained from the experimental program. The result of nonlinear analysis could be useful to predict the actual behavior characteristics of the bearing wall system subjected to lateral loads.