• Title/Summary/Keyword: beam position

Search Result 946, Processing Time 0.03 seconds

Relationship between the Zhejiang Province area(China) and wooden architecture from the Koryo Period based on the beam and the structure (보 결구를 통해 본 중국 절강지역과 고려시기 목조건축과의 관계 - '차견(箚牽)'과 초방(草枋), '묘량(猫梁)'과 우미량(牛尾梁)을 중심으로 -)

  • Lee, Yong-Jun
    • Journal of architectural history
    • /
    • v.15 no.4
    • /
    • pp.75-86
    • /
    • 2006
  • Korea is closed to China in the geographical position and is related to China as two countries have developed similar culture, art, and social systems. Architecture is a kind of culture and has advanced in the wooden architecture with a considerable change. The study investigated a phylogenetic relationship between two countries based on characteristics of architectural universality. With comparison and analysis on the common feature and difference of the beam and structure in the wooden architecture from the Koryo and Zhejiang Province(China), the systemicity of the wooden architecture was examined. The beam is a part of timber which is consist of the wooden structure frame and also a crucial subject to understand a development process of the wooden architecture.

  • PDF

Active Vibration Control of a Cantilever Beam using Electromagnetic Actuators

  • Kangwoong Ko;Sooyoung Choi;Kiheon Park
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.65-71
    • /
    • 2002
  • In this paper, an experiment for the active vibration control of a cantilever beam uses electromagnet as an actuator and uses a laser sensor to measure the position of the bending beam, constituting a non-contacting control system. A mathematical model of the overall system is derived to analytically design an appropriate controller. Dynamic equations of the electromagnetic actuator and the beam are combined to find the transfer function from the actuator to the sensor. The effectiveness of the obtained model is verified by various experiments and an improper PID controller is designed based on the obtained model. According to analysis, the coefficient of the derivative controller is the most important parameter for handling the performance and the stability margin of the control system. The experimental results of the active control system are compared with those of the open loop system.

  • PDF

A study on the Modeling and Dynamic Analysis of Cracked Beam Structures (균열이 있는 보의 모델링 및 동적 해석에 관한 연구)

  • 홍성욱;김만달;이종원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.197-204
    • /
    • 2003
  • This paper presents an efficient modeling and dynamic analysis method for open cracked beam structures. An equivalent bending spring model is introduced to represent the structural weakening effect in the presence of cracks. The proposed method adopts the exact dynamic element method (EDEM) to avoid the inconvenience and numerical errors in association with re-meshing the structural model with the crack position changed. The proposed modeling method is validated through a series of simulation and experiments. First, the proposed method is rigorously compared with a commercial finite element code. Then, two kinds of experiments are performed to validate the proposed modeling method. Finally, a diagnostic scheme fur open cracked beam structures is proposed and demonstrated through a numerical example.

A Position control of Ball-Beam using CDM (CDM을 이용한 Ball-Beam 위치제어)

  • 정지연;추연규;임영도
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.139-142
    • /
    • 2002
  • 제어 시스템에서 제어기를 설계하는 방법에는 기존 PID 설계 기법인 Ziegler-Nichols와 Jung, R. C. Dorf 방법들이 있다. 본 논문은 Shunji Manabe의 계수도법(CDM Coefficient Diagram Method)을 이용하여 Ball-Beam 시스템을 제어하기 위한 PID 제어기를 설계한다. PID 제어기의 각 파라메터인 P, I, D 계수는 시스템의 속도와 안정성에 기인하는 표준 안정도 지수$(\gamma)$와 등가시정수$(\tau)$ 로부터 얻 어진다. 등가시정수$(\tau)$와 안정도 지수$(\gamma)$는 제어기 파라메터의 대수적 형태와 절대적인 관계가 있다. 그러므로 설계된 제어기로부터 빠른 상승시간과 안정된 정상상태 응답을 얻을 수 있다. Ball-Beam 시스템에 CDM 제어기를 적용한 결과 시스템의 안정도, 정확성 그리고 강인성에 있어서 퍼지 제어기나 PID 제어기에 비해 뛰어난 응답 특성을 확인하였다

Design and Analysis of Multi Beam Space Optical Mixer

  • Lian Guan;Zheng Yang
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.56-64
    • /
    • 2024
  • In response to the current situation where general methods cannot effectively compensate for the phase delay of ordinary optical mixers, a multi-layer spatial beam-splitting optical mixer is designed using total reflection triangular prisms and polarization beam splittings. The phase delay is generated by the wave plate, and the mixer can use the existing parallel plates in the structure to individually compensate for the phase of the four output beams. A mixer model is established based on the structure, and the influence of the position and orientation of the optical components on the phase delay is analyzed. The feasibility of the phase compensation method is simulated and analyzed. The results show that the mixer can effectively compensate for the four outputs of the optical mixer over a wide range. The mixer has a compact structure, good performance, and significant advantages in phase error control, production, and tuning, making it suitable for free-space coherent optical communication systems.

Position of the hyoid bone and its correlation with airway dimensions in different classes of skeletal malocclusion using cone-beam computed tomography

  • Shokri, Abbas;Mollabashi, Vahid;Zahedi, Foozie;Tapak, Leili
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.105-115
    • /
    • 2020
  • Purpose: This study investigated the position of the hyoid bone and its relationship with airway dimensions in different skeletal malocclusion classes using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans of 180 participants were categorized based on the A point-nasion-B point angle into class I, class II, and class III malocclusions. Eight linear and 2 angular hyoid parameters(H-C3, H-EB, H-PNS, H-Me, H-X, H-Y, H-[C3-Me], C3-Me, H-S-Ba, and H-N-S) were measured. A 3-dimensional airway model was designed to measure the minimum cross-sectional area, volume, and total and upper airway length. The mean crosssectional area, morphology, and location of the airway were also evaluated. Data were analyzed using analysis of variance and the Pearson correlation test, with P values <0.05 indicating statistical significance. Results: The mean airway volume differed significantly among the malocclusion classes(P<0.05). The smallest and largest volumes were noted in class II (2107.8±844.7 ㎣) and class III (2826.6±2505.3 ㎣), respectively. The means of most hyoid parameters (C3-Me, C3-H, H-Eb, H-Me, H-S-Ba, H-N-S, and H-PNS) differed significantly among the malocclusion classes. In all classes, H-Eb was correlated with the minimum cross-sectional area and airway morphology, and H-PNS was correlated with total airway length. A significant correlation was also noted between H-Y and total airway length in class II and III malocclusions and between H-Y and upper airway length in class I malocclusions. Conclusion: The position of the hyoid bone was associated with airway dimensions and should be considered during orthognathic surgery due to the risk of airway obstruction.

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

Estimation of Spatial Variations in a Light Source by Optical Fiber Sensory System (광섬유를 이용한 광원 위치의 미세 변위 추정)

  • Kim, Ji-Sun;Jung, Gu-In;Lee, Tae-Hee;Choi, Ju-Hyeon;Oh, Han-Byeol;Kim, A-Hee;Park, Hee-Jung;Kim, Kyung-Seop;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1283-1289
    • /
    • 2013
  • The purpose of this study is to find the new method for estiming the spatial variations in a light source with utilizing the optical fiber sensory system. With this aim, firstly the asymmetry in the beam profile of a light source is evaluated by using the tipped optical fiber with 0, 10, 20, 30, 40, 45-degree angle. Secondly the variation of position in a light source is estimated by adjusting the relative position between the light source unit (XYZ stage, LED, Optical fiber) and the receiver unit (Photodiode, XYZ stage). Our experimental results show that the spatial variation of a light source can be resolved in terms of the variations in beam profile with varying the tip angle of an optical fiber and adjusting the relative distance between the light source unit and the receiver.

Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study

  • Nikbin, Ava;Kajan, Zahra Dalili;Taramsari, Mehran;Khosravifard, Negar
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.245-254
    • /
    • 2018
  • Purpose: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures(VRFs). Materials and Methods: Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. Results: The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. Conclusion: Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.