• Title/Summary/Keyword: beam measurement

Search Result 1,542, Processing Time 0.026 seconds

A Survey Tool for the Measurements of the Rock Parting Surfaces (암반의 불연속면 배열을 측량하는 원격 영상측량기)

  • 황상기;임유진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.697-704
    • /
    • 2000
  • This study presents methodology and tools for remote measurement of the orientation of the rock parting surfaces. Two close circuit video camera capture the pictures of a rock excavation surface while a laser beam scans the surface. Positions of the laser beams in the two digital images are recognized by image processing. Using the stereoscopic concept, three dimensional coordinations of the rock surface and the orientation of the rock parting planes are calculated. Point, cross and line type laser beams are tested for better image processing results and measurement accuracy of the coordinates. According to a simple accuracy test, cross beam show better results than the point beam. However, line beam show more promising results for the measurement of the rock parting surfaces.

  • PDF

Determination of the Virtual Focus Position for Electron Beam with Air Scanning (전자선에서 Virtual Source Distance의 위치 결정)

  • Kwon Kyung Tea;Youn Wha Ryong;Park Kwang Ho;Kim Chung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.89-93
    • /
    • 1994
  • Authors have measured virtual source distance of electron beam from CL/1800 medical linear accelerator, with newly designed method. Beam scanning was performed with the direction of beam axis in the air. Compared results between this study and well established in phantom measurement shows good agreement with in experimental error. And we have found that build-up cap plays very important role in air measurement because of charge build up. The method of in-air measurement of virtual source distance is very easy to set-up and generate accurate results.

  • PDF

BGA Height Measurement Using Pattern Beam (패턴 빔을 이용한 BGA 단차 측정)

  • Shin, Sang-Hoon;Yu, Young-Hun
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.361-365
    • /
    • 2009
  • We describe a simple method to obtain an optical sectioning in a conventional wide-field microscope by projecting a single spatial frequency grid pattern onto the object. Using a patterned beam, we have measured the height of BGA with a rough surface that provide the coherence noise. The configuration of the height measurement system using pattern beam is simple. The image acquired by this system is not depend on the coherence noises. This system is also applicable to the sample reference plan that has no pattern on ground. The reappearance and accuracy are outstanding and applicable to many industrial optical metrology.

Dose Calculation of Photon Beam with Wedge Filter for Radiation Therapy Planning System

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Lee, Hyoung-Koo;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.41-41
    • /
    • 2003
  • Purpose: Even if the wedge filter is widely used for the radiation therapy to modify the photon beam intensity, the wedged photon beam dose calculation is not so easy. Radiation therapy planning systems (RTPS) have been used the empirical or semi-analytical methods such as attenuation method using wedge filter parameters or wedge filter factor obtained from measurement. However, these methods can cause serious error in penumbra region as well as in edge region. In this study, we propose the dose calculation algorithm for wedged field to minimize the error especially in the outer beam region. Materials and Method: Modified intensity by wedge filter was calculated using tissue-maximum ratio (TMR) and scatter-maximum ratio (SMR) of wedged field. Profiles of wedged and non-wedged direction was also used. The result of new dose calculation was compared with measurement and the result from attenuation method. Results: Proposed algorithm showed the good agreement with measurement in the high dose-gradient region as well as in the inner beam region. The error was decreased comparing to attenuation method. Conclusion: Although necessary beam data for the RTPS commissioning was increased, new algorithm would guarantee the improved dose calculation accuracy for wedged field. In future, this algorithm could be adopted in RTPS.

  • PDF

ML-6M선형 가속기에서의 BEAM 특성에 대한 고찰

  • Mun, Eon-Cheol;Yun, Byeong-Un;O, Yang-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.5 no.1
    • /
    • pp.115-119
    • /
    • 1992
  • The beam characteristics and dosimetric measurements of the 6MV X-ray and 6MeV electron beam from a ML-6M linear accelerator are examined. The Percent Depth Dose(PDD) table and the tissue Maximum Ratio(TMR) table are taken from measurement as a function of the field size and the depth. The calculated TMR table from PDD table is compared with those from measurement. Other beam characteristics such as output factor, beam profile(including flatness, symmetry and penumbra), wedge, and the variation of Dmax are presented. All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

Illuminance Uniformity of Beam Projector for Solar Cell Quantum Efficiency Distribution Measurement (태양전지 양자효율 분포측정을 위한 빔프로젝터의 광조도분포 균일화)

  • Yu, Jae-Geun;Kim, Seung-Gwan;Lee, Dong-Hun;Park, Cheol-Ung;Park, Seung-Nam
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.298-299
    • /
    • 2009
  • Use of a DLP-beam projector is proposed to measure solar cell quantum efficiency distribution. The measurement requires a good spatial uniformity of the beam from the projector. We measured the spectral power distribution of the beam projector and the spatial uniformity of the white beam. By changing the gray level of the white beam at the measured spatial points, we improved the spatial illuminance uniformity to be about 2 % which was otherwise as much as 400 %.

  • PDF

Magnetic field imperfections of in-vacuum undulator on PLS-II beam dynamics

  • Chunjarean, Somjai;Hwan, Shin-Seung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.359-359
    • /
    • 2011
  • Many research applications in basic sciences and biology such as protein crystallography require hard x-rays in the range of 3-20 keV with high brightness. A medium energy storage ring as PLS-II with a beam energy of 3 GeV can meet such high photon energies. In-vacuum undulators (IVU) with a period length of 20 mm and a peak field of 0.97 T are used in the PLS-II ring to produce such X-rays in the fundamental or higher harmonics. Due to the many poles and high fields, insertion devices like wigglers and undulators have a significant impact on the stability of the electron beam with potential degradation of beam quality and life time. Therefore, nonlinear fields must be determined by measurement and evaluated as to their impact on beam stability. Specifically, transverse field roll-off can be a serious detriment to injection in top-up mode and must be corrected. We use magnetic field measurement data to evaluated beam stability by tracking particles using an explicit symplectic integrator in both, transverse and longitudinal planes.

  • PDF

An experimental method to determine glass elastic modulus based on the fundamental frequency of the elastic support-free end beam

  • Kun Jiang;Danguang Pan
    • Structural Engineering and Mechanics
    • /
    • v.88 no.2
    • /
    • pp.189-200
    • /
    • 2023
  • Silicate glass is usually a brittle and plate-like material, and it is difficult to measure the elastic modulus by the traditional method. This paper develops a test method for the glass elastic modulus based on the fundamental frequency of the cantilever beam with an elastic support and a free end. The method installs the beam-type specimen on a semi-rigid support to form an elastic support-free end beam. The analytic solution of the stiffness coefficients of the elastic support is developed by the fundamental frequency of the two specimens with known elastic modulus. Then, the glass elastic modulus is measured by the fundamental frequency of the specimens. The method significantly improves the measurement accuracy and is suitable for the elastic modulus with the beam-type specimen whether the glass is homogeneous or not. Several tests on the elastic modulus measurement are conducted to demonstrate the reliability and validity of the test method.

A Study on the Metallic Surface Roughness Measurement in Turning by Laser Beam (선삭가공시 LASER BEAM을 이용한 금속의 표면 거칠기 측정에 관한 연구)

  • 김희남;남무호;황재연;박희재
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.58-65
    • /
    • 1991
  • In - process measurement of surface roughness is introduced which employs an optical method by using laser beam. This makes it possible to detect the surface roughness not only along the circurnferential path but also along the feed direction even during machining. The maximum roughness value is always abtainable from the reading along the feed direction.

  • PDF

Measurements of the In-Plane Vibration Intensity of a Beam Using an Reference Accelerometer (기준 가속도계를 이용한 보의 면내 진동인덴시티 측정)

  • Kim, C. R.;H. G. Kil;J. S. Jeon;S. Y. Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.383.2-383
    • /
    • 2002
  • In this paper, an experimental technique using a reference accelerometer has been developed to measure the in-plane vibration intensity of a beam. It has the advantages of shortening measurement time and reducing accelerometer phase error comparing with the cross spectral Intensity measurement technique using an accelerometer array. The distribution of the in-plane vibration Intensity over the beam has been measured. (omitted)

  • PDF