• Title/Summary/Keyword: beam bridge

Search Result 620, Processing Time 0.022 seconds

Integral Bridge Using H-pile (H-말뚝을 이용한 일체식교대 교량)

  • 정경자;김성환;유성근
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.241-248
    • /
    • 1999
  • The existing bridge with deck joint has many problems during construction and maintenance. To overcome these difficulties, an integral bridge, which is defined as the practice of constructing bridges without deck joints, is proposed in this study. A test bridge with 3 spans of PC beam was selected to verify the function of the bridge and is under construction. Characteristics of integral bridge are followings: $\circled1$ Flexible H-piles under the abutment are installed to accommodate thermal movements of the superstructures of bridge. $\circled2$ PC beam of the superstructure and the abutment are integrated. $\circled3$ The existing approach and relief slabs are applied to minimize the stress transfer occurred from the bridge deck to the pavement. $\circled4$ A cyclic control joint is installed between approach and relief slabs to absorb the thermal movement. $\circled5$ It is used a dual direction bearing which is cheaper than single direction bearing and has a good workability as well. It is also installed a shear block on the top of pier coping to protect the lateral movement caused by temperature change and earthquake.

  • PDF

Evaluation of the Load Carrying Capacity on a Rahmen Bridge with Ultra-high Strength Centrifugally Formed Square Beams as the Superstructure (초고강도 원심성형 각형보를 상부구조로 하는 라멘교의 내하성능 평가 )

  • Doo-Sung Lee;Sung-Jin Kim;Jeong-Hoi Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.61-69
    • /
    • 2024
  • An ultra-high strength prestressed prismatic beam of 100 MPa in compressive strength was developed by increasing the water-tightness of concrete by utilizing centrifugal molding processes without adding expensive admixtures. The centrifugal prismatic PSC beam developed as the superstructure of the avalanche tunnel was constructed on a rahmen bridge in a small local river. In this study, the centrifugal prismatic beam was compared and analyzed based on the results of measurements made through static load tests and the results of numerical analysis of the target structure. The common load-carrying capacity and safety of the rahmen bridge were evaluated. The static·dynamic load tests and finite element analysis results of this bridge were similar, and it was confirmed that the behavior of the centrifugal prismatic beam was well simulated. All centrifugally formed square beams that make up the composite rahmen bridge were evaluated to secure sufficient load carrying capacity under the design live load, and structural reliability was proven by ensuring safety.

Behaviors of PSC-Beam Bridges According to Continuity of Spans (2) (PSC-Beam 교량의 연속화에 따른 거동해석 (2))

  • 곽효경;서영재;정찬묵;박영하
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.21-31
    • /
    • 1999
  • The companion paper presents an analytical model to predict behaviors of PSC-Beam bridges according to continuity of spans. This paper aims at providing several examples of its application to PSC-Beam bridge. In this regard, many uncertainties affecting to the continuity of spans (such as the ultimate shrinkage strain of slab and girders, the prestressing creep of girders, and the time adopting prestressing force) are analysis in detail. Moreover, to increase the serviceability and to remove th inherent structural defects including the cracking at interior supports, a necessity for the parametric studies of PSC-Beam bridges reflecting the construction sequence is emphasized.

Design of P.C. Beam Bridge using High Strength Concrete (고강도 콘크리트를 사용한 P.C. Beam교의 설계)

  • 강상규;윤석구;이형준;정원기;이규정
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.446-449
    • /
    • 1997
  • The use of high strength concrete in the fabrication and construction of prestressed concrete beam bridges can result in the increase of girder spacings for standard shapes, as well as the increase of span lengths. The increase of girder spacings corresponds to the reduction of the required number of girders. This study shows that the use of high strength concrete make prestressed concrete beam bridges the economical alternative to any other bridge types. Also, this study has the purpose of giving aids to design of prestressed concrete beam. To achieve this purpose this study provides the plots resulting from research on relationships between the concrete strength of prestressed concrete beam, girder spacing and the number of strands in various span lengths.

  • PDF

Synthesis of DOT Use of Beam End Protection for Extending the Life of Bridges

  • Radlinska, Aleksandra;McCarthy, Leslie Myers;Matzke, James;Nagel, Francis
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.3
    • /
    • pp.185-199
    • /
    • 2014
  • As the national transportation infrastructure ages and deteriorates, many existing bridges require frequent and costly maintenance and repairs. The objective of this work was to synthesize new and existing types of beam end coatings and treatments that have been proven to extend the life of new and existing concrete and steel bridge beams. A comprehensive literature review, along with online surveys and phone interviews of State department of transportations (DOTs) and coating manufacturers was conducted to gather information about existing and recently developed technologies. The study revealed that while many promising coatings and treatments are offered on the market, there is a lack of readily available laboratory results that would enable direct comparison of the available methods. This finding applies in terms of the coatings' durability and the potential for extending the service life of existing bridges. Most of the interviewed State DOTs' personnel assessed the products listed in respective DOT's Qualified Products Lists as performing 'well'. However, there was significant variability between states in the type of the products used. Among the agencies contacted, none was able to suggest the most promising or advanced products, either for concrete or steel bridge beam end treatments. This suggests that comprehensive laboratory evaluation would be necessary for selecting the best available beam end treatments and coatings.

A new method to identify bridge bearing damage based on Radial Basis Function Neural Network

  • Chen, Zhaowei;Fang, Hui;Ke, Xinmeng;Zeng, Yiming
    • Earthquakes and Structures
    • /
    • v.11 no.5
    • /
    • pp.841-859
    • /
    • 2016
  • Bridge bearings are important connection elements between bridge superstructures and substructures, whose health states directly affect the performance of the bridges. This paper systematacially presents a new method to identify the bridge bearing damage based on the neural network theory. Firstly, based on the analysis of different damage types, a description of the bearing damage is introduced, and a uniform description for all the damage types is given. Then, the feasibility and sensitivity of identifying the bearing damage with bridge vibration modes are investigated. After that, a Radial Basis Function Neural Network (RBFNN) is built, whose input and output are the beam modal information and the damage information, respectively. Finally, trained by plenty of data samples formed by the numerical method, the network is employed to identify the bearing damage. Results show that the bridge bearing damage can be clearly reflected by the modal information of the bridge beam, which validates the effectiveness of the proposed method.

Series tuned mass dampers in train-induced vibration control of railway bridges

  • Kahya, Volkan;Araz, Onur
    • Structural Engineering and Mechanics
    • /
    • v.61 no.4
    • /
    • pp.453-461
    • /
    • 2017
  • This paper presents the series multiple tuned mass dampers (STMDs) to suppress the resonant vibrations of railway bridges under the passage of high-speed trains (HSTs). A STMD device consisting of two spring-mass-damper units connected each other in series is installed on the bridge. In solution, bridge is modeled as a simply-supported Euler-Bernoulli beam with constant cross-section, and vehicle is simulated as a series of moving forces with constant speed. By the assumed mode method, the governing equations of motion of the beam-TMD device coupled system traversed by a moving train are obtained. The optimum values for the parameters of the STMD device are obtained for the criterion based on the minimization of the maximum dynamic displacement of the beam at its midspan. Single TMD and multiple TMDs in parallel are also considered for demonstration of the STMD device's performance. The results show that STMDs are effective in bridge vibration suppression and robust to parameters' change in the main system and the absorber itself.

Bridge-type structures analysis using RMP concept considering shear and bending flexibility

  • Hosseini-Tabatabaei, Mahmoud-Reza;Rezaiee-Pajand, Mohmmad;Mollaeinia, Mahmoud R.
    • Structural Engineering and Mechanics
    • /
    • v.74 no.2
    • /
    • pp.189-199
    • /
    • 2020
  • Researchers have elaborated several accurate methods to calculate member-end rotations or moments, directly, for bridge-type structures. Recently, the concept of rotation and moment propagation (RMP) has been presented considering bending flexibility, only. Through which, in spite of moment distribution method, all joints are free resulting in rotation and moment emit throughout the structure similar to wave motion. This paper proposes a new set of closed-form equations to calculate member-end rotation or moment, directly, comprising both shear and bending flexibility. Furthermore, the authors program the algorithm of Timoshenko beam theory cooperated with the finite element. Several numerical examples, conducted on the procedures, show that the method is superior in not only the dominant algorithm but also the preciseness of results.

Study on Plastic Deformation of Interior Support at the Continuous I-Beam Bridge (I-Beam연속교 내측지점의 소성변형에 관한 연구)

  • Chung, Kyung-Hee;Kim, Jin-Sung;Yang, Seung-Ie
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.146-152
    • /
    • 2002
  • The steel shows plastic deformation after the yield point exceeds. Because of overloads, the plastic deformation occurs at the interior support of a continuous bridge. The plastic deformation is concentrated at the interior support, and the permanence deformation at the interior support remains after loads pass. Because local yielding causes the positive moment at the interior support, it is called "auto moment". Auto moment redistributes the elastic moment. Because of redistribution, auto moment decreases the negative moment at the interior support of a continuous bridge. In this paper, the moment-rotation curve from Schalling is used. The Plastic rotation is computed by using Beam-line method, and auto moment is calculated based on the experiment curve. The design example is presented using limit state criterion.

Near-explosion protection method of π-section reinforced concrete beam

  • Sun, Qixin;Liu, Chao
    • Geomechanics and Engineering
    • /
    • v.28 no.3
    • /
    • pp.209-224
    • /
    • 2022
  • In this study, the numerical analysis model of π-beam explosion is established to compare and analyze the failure modes of the π-beam under the action of explosive loads, thus verifying the accuracy of the numerical model. Then, based on the numerical analysis of different protection forms of π beams under explosive loads, the peak pressure of π beam under different protection conditions, the law of structural energy consumption, the damage pattern of the π beam after protection, and the protection efficiency of different protective layers was studied. The testing results indicate that the pressure peak of π beam is relatively small under the combined protection of steel plate and aluminum foam, and the peak value of pressure decays quickly along the beam longitudinal. Besides, as the longitudinal distance increases, the pressure peak attenuates most heavily on the roof's explosion-facing surface. Meanwhile, the combined protective layer has a strong energy consumption capacity, the energy consumed accounts for 90% of the three parts of the π beam (concrete, steel, and protective layer). The damaged area of π beam is relatively small under the combined protection of steel plate and aluminum foam. We also calculate the protection efficiency of π beams under different protection conditions using the maximum spalling area of concrete. The results show that the protective efficiency of the combined protective layer is 45%, demonstrating a relatively good protective ability.