• Title/Summary/Keyword: bag sampling

Search Result 42, Processing Time 0.025 seconds

Comparison of sample storage containers for the analysis of volatile organic compounds (VOC) (휘발성유기물(VOC) 분석을 위한 시료보관 용기의 비교)

  • Kim, Seokyung;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.116-123
    • /
    • 2022
  • Polymer bags, metallic canisters, and glass bottles have been used as containers for analyzing the volatile organic compounds (VOCs) in air. In this study, various sampling containers were compared to investigate the short-term stability of VOCs, that is, from the time they are sampled to the time they are analyzed. Polyvinyl fluoride (PVF), polypropylene (PP), polyester aluminum (PE-Al) bags, canisters, and glass bottles were used as sample containers. A 100 nmol/mol standard gas mixture of benzene, toluene, ethylbenzene, m-xylene, styrene, and o-xylene was used for the VOC comparison. Changes in the concentrations of samples stored for 10~20 day in each container were measured using a thermal desorption-gas chromatograph-flame ionization detector (TD-GC-FID). As a result, VOCs stored in a canister and two kinds of amber glass bottles have shown immaterial decreases in concentration in one week, and more than 80 % of the initial concentration was maintained for two weeks. In the case of polymer bags, the concentration of all VOCs, except benzene and toluene, were remarkably decreased below 70% of the initial concentration in one day. Particularly, ethylbenzene, xylene, and styrene have shown dramatic decreases in concentration below 30 % of the initial concentration in all polymer bags in one day.

Comparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME

  • Yu, Mee-Seon;Lee, Jae-Chun;Yang, Sung-Bong;Kim, Doo-Hwan;Cho, Sung-Back;Whang, Ok-Wha
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1539-1549
    • /
    • 2013
  • The purpose of this study is to compare the sampling methods for monitoring indoles (phenol, p-cresol, indole and skatole) in airs of swine facility. As the collecting methods of indoles in air, Tenax-TA adsorption tube and solid phase microextraction (SPME) were examined. For the preparation of calibration curves of indoles concentrated in Tenax-TA, the standard indoles solutions were spiked in each of Tenax-TA tubes and thermally desorbed (ATD) into a gas chromatograph combined with mass detector (GC/MS). And for the preparation of calibration curves by SPME, indoles in the standard gaseous solution prepared by evaporating the aqueous solution that contained indoles into a polyester sampling bag were extracted with SPME fiber and subsequently analyzed by the GC/MS. Two sampling methods were evaluated for extracting indoles present in swine building environments. Results indicated that the SPME method using Polydimethylsiloxane/ Divinylbenzene (PDMS/DVB) fiber was more effective than Tenax-TA method in extracting indoles. The gas chromatographic analysis showed that the linearities of calibration curves and detection limits were useful for detection of indoles in swine airs. The field tests also showed that considerably different levels of indoles were present in various parts of the swine building.

Evaluation of the Charcoal Tube Sampling Method for Carbon Disulfide in Air (활성탄관법을 이용한 공기중 이황화탄소 농도 측정법에 관한 연구)

  • Lee, Na Roo;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.22-36
    • /
    • 1993
  • This study was conducted to evaluate the charcoal tube sampling method for carbon disulfide in the air. Breakthrough was investigated according to flow rate, sampling time and air volume. Also the storage stability by storage method and time was investigated. The results are summarized as follows. 1. The samples stored at room temperature($28.2^{\circ}C$), refrigerator($3.8^{\circ}C$) and freezer($-15.6^{\circ}C$) were analyzed every week to five weeks. At one week storage at room temperature, 3.5% of $CS_2$ in the front section of the charcoal tube migrated into the back section and 57.7% at five weeks. The amount of $CS_2$ in the back section of the charcoal increased continuously by storage time. Migration of $CS_2$ was slow at refrigerator, and stopped occur at freezer. Recovery rate $CS_2$ was 52-82% at room temperature and 92-101% at refrigerator, based on the amount at freezer as a reference value. Thus loss was observed at room temperature. 2. When 6-48 L of fresh air were passed through tubes with spiked amounts of 0.379 and 0.759mg sample, the amounts of $CS_2$ in the back section of charcoal were 5.7-132.4 and 0-92% of the amount in the front section, respectively. The total recovery rates of$CS_2$ from 0.379 and 0.759mg spiked sample were 35.7-101.0% and 9l.3-100.1%, respectively. $CS_2$ loss was observed in 0.379mg spiked sample, but not in 0.759mg spiked sample. In the spiked samples, the amount of $CS_2$ in the back section of charcoal was not affected by flow rate when the air volume was controlled. The amount of $CS_2$ in the back section of charcoal increased over sampling time. And the faster the flow rate, the more the migration amount when the sampling time was the same. 3. A known concentration, 10 ppm of $CS_2$, was produced in a 200 L Tedlar bag. When the air volume was 24, 36, 48 L, breakthrough was 5.8, 16.9, 47.4%, respectively. The sampling flow rate of 0.05, 0.1, 0.2 Lpm did not change the breakthrough rate. Breakthrough increased over sampling time. And the faster the flow rate, the more the breakthrough, when the sampling time was the same.

  • PDF

Purchasing Behavior of the Latest Trendy Color Bags - Focusing on Purchase Motives, Purchase Types, Satisfaction and Repurchase Intention - (최신 유행색 가방 구매행동 - 구매동기, 구매유형, 만족도 및 재구매 의도를 중심으로 -)

  • Kim, Eun Joo;Lee, Min Ji
    • Fashion & Textile Research Journal
    • /
    • v.16 no.5
    • /
    • pp.719-729
    • /
    • 2014
  • This study identified factors for purchase motives in regards to the latest trendy color bags as well as ascertained the structural relations of purchasing behavior in regards to purchase motives, purchase type, satisfaction, and repurchase intention. Other purposes examined the differences in purchase motivations, purchase types, satisfaction, and repurchase intention according to consumer characteristics, and provided strategic information on women's bag manufacturers and retailers. A random sampling method collected data based on a survey of Korean women between the ages of 20 and 59 who had purchased the latest trendy color bag. A questionnaire developed by the researcher was distributed to 450 women in 2013. We analyzed 433 questionnaires using the SPSS 18.0 program and AMOS 18.0 program. The summarization of the findings are as follows. First, purchase motives for the latest trendy color bags were classified into 5 factors: awareness-symbolicity, practicality, aesthetic, harmony, and fashionability. Second, aesthetic and harmony showed significant influenceson planned purchases due to an analysis of structural relations between purchase motives for the latest trendy color bags and type of purchase; in addition, awareness-symbolicity, aesthetic and fashionability significantly influenced unplanned purchases. Third, there was no significant influence for planned purchases on satisfaction; however, unplanned purchases showed a significant.

A Study on the Effect of Cold Application Using a Sponge Bath in Healthy Adults (냉요법 적용방법에 따른 냉요법 효과에 관한 연구-건강한 성인 여성에서 스폰지 목욕방법을 중심으로)

  • Chung, Hyun-Sook;Kang, Kyu-Sook;Hwang, Ae-Ran
    • The Korean Nurse
    • /
    • v.28 no.3
    • /
    • pp.68-82
    • /
    • 1989
  • This study was a quasi-experimental research study to test the characteristics of temperature regulation according to sponge bath methods of cold application. Thirteen volunteers were selected from among nursing college students according to an established criteria using a purposive sampling technique. Four different cold application methods were used: $\circled1$ tepid water sponge bath at $28^{\circ}C$, $\circled2$ 20% alcohol sponge bath at $28^{\circ}C$, $\circled3$ 40% alcohol sponge bath at $28^{\circ}C$ and $\circled4$ tepid water sponge bath at 28$^{\circ}$C plus an ice bag to the head. Changes in rectal temperature, mean skin temperature, mean body temperature, heat content change and thermal discomfort during the cold application were measured at 5 minute intervals over a 120 minute period. The data collection period was from Dec. 20, 1988 to Feb. 3, 1989. The data were analyzed using descriptive statistics, simple regression, ANOVA, Duncan's multiple range test and Pearson correlation coefficient using the SPSS-X Program. The results of the study are summarized as follows. Five general hypothesis were tested. Hypothesis 1 that "Change in heat content will be decreased for each cold application method according to the cold application time" was rejected. (tepid water sponge bath: after 10 minutes of cold application, 20% alcohol sponge bath: after 25 minutes of cold application: 40% alcohol sponge bath: after 45 minutes of cold application, tepid water sponge bath plus an ice bag to the head: after 80 minutes of cold application) Hypothesis 2 that "Thermal discomfort will be changed for each cold application method according to the cold application time" was rejected after 5minutes of cold application. Hypothesis 3 that "Change in heat content will differ among the cold application methods" was accepted except 0~5, 0~10, 0~65, 0~105 and 0~120 minute. This difference showed significance only between sponge bath methods and tepid water sponge bath plus an ice bag to the head. Hypothesis 4 that "Thermal discomfort will differ among the cold application methods" was accepted at 15, 20, 35, 45, 75, 80, 90, 95, 100, 105, 110, 115 and 120 minute of cold application time. This difference showed significance only between sponge bath methods and tepid water sponge bath plus an ice bag to the head. Hypothesis 5 that "The higher the change in heat content, the higher the thermal discomfort during the cold application time" was accepted for between 10~60 and 75 minute of cold application. In conclusion, this study showed that in sponge bath at $28^{\circ}C$, 10~80 minute was a effective cold application time in the view of heat loss through the skin. Concerning the effects of evaporation and thermal discomfort, it was found that there was no difference with regard to the solutions; tepid water sponge bath; 20% alcohol sponge bath or 40% alcohol sponge bath at a $28^{\circ}C$ controlled solution temperature. So it was thought that the type of solution itself did not have a big influence on the heat loss through skin. The combined effect of sponge bath with an ice bag to the head showed a significant difference and also showed a slight increase in thermal discomfort. On the basis of this research it can be concluded that cold application, for example, an ice bag to the head during a tepid water sponge bath is a good method as it increase heat loss through conduction, although fit can also cause a slight increase in thermal discomfort. The correlation between changes in heat content and thermal discomfort were not high. So factors other than change in heat content are considered to have an effect on the cognition of thermal discomfort.

  • PDF

A review of analytical method for volatile fatty acids as designated offensive odorants in Korea (악취성 유기지방산 성분의 분석기술)

  • Ahn, Ji-Won;Kim, Yong-Hyun;Kim, Ki-Hyun;Song, Hee-Nam
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.91-101
    • /
    • 2012
  • A list of volatile fatty acids (VFA) including propionic acid, butyric acid, isovaleric acid, valeric acid, etc. is well known for offensive odorants. The analysis of odorant VFA is a highly delicate task due to high reactivity and unstable recovery rate. At present, analytical methods of VFA are recommended to include alkali impregnation filter method and alkali absorption method by the malodor prevention law of the Korea Ministry of Environment (KMOE). In this review, a survey has been made to explore various approaches available for the analysis of VFA to include both official methods of the KMOE and others. In light of the unreliability of those established analytical methods, it is highly desirable to develop some substituting methods for VFA. Among such options, one may consider such option as sorbent tube (ST) sampling and cryogenic trapping-thermal desorption technique. Moreover, procedures used for standard preparation, sampling steps, and instrumental detection stage are also evaluated. Application of container sampling (like Tedlar bag) is however not recommendable due to significant (sorptive) loss in sampling and in storage stage. In the detection stage, the use of GC/MS is recommendable to replace GC/FID due to the presence of diverse interfering substances. Thus, it is essential to properly establish the basic quality assurance (QA) for VFA analysis in air.

Methods for Determination of Amino Acids Bioavailability in Pigs - Review -

  • Zebrowska, T.;Buraczewski, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.5
    • /
    • pp.620-633
    • /
    • 1998
  • Methods developed for measuring digestibility and availability of amino acids in feedstuffs used in pig nutrition are reviewed. Digestibility is a proportion of an amino acid in a feed that is absorbed from the digestive tract and should be determined from the difference between the amount of amino acid consumed and passing the distal ileum. Techniques for ileal digesta sampling including various types of cannulas: a re-entrant, T-piece, IPV, IPVC and ileaorectal anastomosis are described and comparisons amongst these methods are presented. Other methodologies like mobile bag technique, in vitro assays and mathematical prediction method are also described. Significance and methodologies for measurement of endogenous nitrogen and amino acids losses at the distal ileum and their effect on the apparent and true nitrogen and amino acid digestibilities in feeds are discussed. Factors influencing the apparent and true amino acid digestibilities such as dry matter intake, protein, fibre and antinutritive compounds content in the diet are discussed. Amino acid bioavailability -the proportion of the total amino acid digested and absorbed in a form utilized in metabolism - measured by the growth assay may differ from its ileal digestibility. Chemical methods for determination of available lysine content in heat treated feeds are evaluated.

Storage and Disposal of Unused Medications for Housewives in the Busan Metropolitan City (부산광역시 주부들의 불용의약품 보관과 처리실태)

  • Hwang, Byung-Deog
    • The Korean Journal of Health Service Management
    • /
    • v.7 no.2
    • /
    • pp.69-79
    • /
    • 2013
  • The purpose of this research is study how housewives dispose unused medications in a household and produce basic research data that can be used to establish efficient recycling and handling of unused medications. Data collection was done using proportional sampling and survey was done in February, 2011. The unused medications in household consist of "tablets(58.4%)", "ointment(31.3%)" and "eyewash(22.7%)". The main way of disposing unused medications was "standard garbage bag(74.1%)". The ideal way of disposing unused medications was "returning to the pharmacy(57.9%)". Only 39.2% of people recognize about unused medications disposal system. In order to establish recycling and treatment of unused medications, it is necessary to create laws and regulations related to unused medications and allocate budget to actively promote the program to public. Most importantly, we must induce doctors and pharmacies to participate in the campaign and there should be laws to require them to explain to their patients how to recycle and treat unused medications when they give prescription and make preparation to them.

Development of Direct Measurement Device for Alveolar Breath Carbon Monoxide

  • Jo, Wan-Kuen;Oh, Jee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E4
    • /
    • pp.181-190
    • /
    • 2002
  • A novel portable device for the direct measurement of alveolar breath carbon monoxide (CO) was developed. The major components of the device include a mouthpiece, non-rebreathing two-way valve, Teflon tube, and CO dosimeter. An alveolar CO measurement can be completed within 1.5 min when using the proposed device and measurement protocol. Measurements could be read to the nearest 0.1 ppm. Humidity did not influence the CO measurements taken by the CO dosimeter, plus there were no problems associated with the recovery and carryover of CO through the device. The criterion for significance in statistical analyses was p< 0.05. The average recovery was 103 and 99% for recovery and carryover experiments, respectively. Test results using the proposed alveolar CO measurement system reflected a good reproducibility. This reproducibility was also supported by the finding that the relative standard deviations (RSDs) of the data sets were less than 7% for the loss experiment and less than 8% for the carryover experiment. Consequently, it would appear that the proposed device can be effectively applied to measure CO levels found in breath, thereby overcoming several disadvantages associated with the conventional bag and adsorbent tube sampling methods.

Antecedents of attitudes toward counterfeit luxury fashion goods (패션명품 복제품 태도에 대한 선행변수)

  • Park, Hye-Jung
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.2
    • /
    • pp.310-325
    • /
    • 2015
  • The market for counterfeit luxury fashion goods is proliferating across the globe. In an effort to provide some insight into this phenomenon, this study aimed to identify the antecedents of attitudes toward counterfeits of luxury fashion goods. As antecedents, counterfeit proneness and attitudes toward counterfeiting were considered. It was hypothesized that counterfeit proneness not only influences attitudes toward counterfeits of luxury fashion goods directly but also indirectly through attitudes toward counterfeiting. Data were gathered by surveying university students in Seoul, using convenience sampling. Three hundred five questionnaires were used in the statistical analysis. SPSS was used for exploratory factor analysis, and AMOS was used for confirmatory factor analysis and path analysis. The results showed that all the fit statistics for the variable measures were quite acceptable. In addition, the overall fits of the hypothesized model suggest that the model fits the data well. Factor analysis revealed that counterfeit proneness and attitudes toward counterfeits of luxury fashion goods were uni-dimensional and that attitudes toward counterfeiting were two dimensional, which are 'normatively less susceptible' and 'value conscious'. Test of the hypothesized path showed that counterfeit proneness influences attitudes toward counterfeits of luxury fashion goods indirectly through the two factors of attitudes toward counterfeiting. The results suggest some implications for anti-counterfeit businesses.