• Title/Summary/Keyword: backward and forward

Search Result 1,002, Processing Time 0.034 seconds

Development of an EEG Software for Two-Channel Cerebral Function Monitoring System (2채널 뇌기능 감시 시스템을 위한 뇌파 소프트웨어의 개발)

  • Kim, Dong-Jun;Yu, Seon-Guk;Kim, Seon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 1999
  • This paper describes an EEG(electroencephalogram) software for two-channel cerebral function monitoring system to detect the cerebral ischemia. In the software, two-channel bipolar analog EEG signals are digitized and from the signals various EEG parameters are extracted and displayed on a monitor in real-time. Digitized EEG signal is transformed by FFT(Fast Fourier transform) and represented as CSA(compressed spectral array) and DSA(density spectral array). Additional 5 parameters, such as alpha ratio, percent delta, spectral edge frequency, total power, and difference in total power, are estimated using the FFT spectra. All of these are effectively merged in a monitor and displayed in real-time. Through animal experiments and clinical trials on men, the software is modified and enhanced. Since the software provides raw EEG, CSA, DSA, simultaneously with additional 5 parameters in a monitor, it is possible to observe patients multilaterally. For easy comparison of patient's status, reference patterns of CSA, DSA can be captured and displayed on top of the monitor. And user can mark events of surgical operation and patient's conditions on the software, this allow him jump to the points of events directly, when reviewing the recorded EEG file afterwards. Other functions, such as forward/backward jump, gain control, file management are equipped and these are operated by simple mouse click. Clinical tests in a university hospital show that the software responds accurately according to the conditions of patients and medical doctors can use the software easily.

  • PDF

Translation and Validation of the Activities of Daily Living Scale with Iranian Elderly Cancer Patients Treated in an Oncology Unit

  • Khoei, Mahtab Alizadeh;Akbari, Mohammad Esmail;Sharifi, Farshad;Fakhrzadeh, Hossein;Larijani, Bagher
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.2731-2737
    • /
    • 2013
  • Background: This study evaluated the validity and reliability of applying the Katz's Activities of Daily Living (ADL) scale in an Iranian sample of elderly oncologic patients following initial cancer treatment. Materials and Methods: The scale was translated with the forward-backward procedure to give an Iranian version. The ADL scale was then applied in a random sample of 400 oncologic patients aged 60 and older following initial cancer treatment. Assessment of the scale stability was twice, with a 14-days (two weeks) interval, to 30 (of the 400) eligible elderly cancer patients in March 2012. To measure treatment effects, the index was run with 150 patients in a three month recall, following oncology processing. Exploratory and confirmatory factor analysis was performed for assessment of construct validity of the Katz's ADL. Reliability was measured with internal consistency (Cronbach's alpha co-efficient), and test/retest (Spearman's r value) of the instrument. Criterion validity was evaluated by comparing the Katz with Physical Function (PF) subscale of SF 36. Known-group validity was approved by comparing of Katz' ADL between quartile groups of PF subscale of SF 36. Results: In our study the ADL demonstrated a high degree of internal homogeneity (Cronbach's alpha 0.923). There was a high correlation between scores of two time measurement of Katz's ADL (p value of two- related- samples test was 0.3). Construct validity showed a correlation coefficient of 0.572 between the ADL and PF scores. In factor analysis, 2 factors were extracted. Evidence for the reliability of the questionnaire was good and known group validity was approved by significant differences of ADL score between quartiles of the PF subscale of SF36. Conclusions: The results suggest that the Iranian version of ADL applied for oncologic older adult patients following initial cancer treatment is a reliable and a valid clinical instrument and comparable to those reported in other studies.

A Study of Electromagnetic Actuator for Electro-pneumatic Driven Ventricular Assist Device

  • Jung Min Woo;Hwang Chang Mo;Jeong Gi Seok;Kang Jung Soo;Ahn Chi Bum;Kim Kyung Hyun;Lee Jung Joo;Park Yong Doo;Sun Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.393-398
    • /
    • 2005
  • An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro­pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations. The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10mm. The actuator dimension was 120mm in diameter and 65mm in height with a mass of 1.4kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80bpm when the afterload was 100mmHg. The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro­pneumatic pump. The authors provide the above results as a preliminary data for further studies.

A Study on Protein Separation with AOT-Isooctane Reverse Micellar System (AOT-Isooctane 역마이셀계를 이용한 단백질 분리에 관한 연구)

  • Rho, Young-Tae;Kim, Young-Sug;Cho, Hyung-Yong;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.542-548
    • /
    • 1989
  • For the selective separation of proteins, the solubilization and desolubilization of proteins in sodium-di-2-ethylhexyl sulfosuccinate (AOT)-isooctane reverse micellar system were investigated. Protein solubilization increased with increasing the concentration of AOT to 200 mM and then decreased above that concentration. Protein was solubilized into reverse micelles in the pH range below the isoelectric Point of each protein, pH 4-10 for lysozyme and pH 5-6 for trypsin and ${\alpha}-chymotrypsin$, Lysozyme, trypsin and ${\alpha}-chymotrypsin$ were efficiently extracted in the precence of KCl and NaCl while larger molecular weight proteins such as pepsin and BSA had high solubilization with $CaCl_2$. At higher ionic strength all proteins exhibited murk less tendency to solubilize and the increase of ionic strength resulted in the decrease of micelle size. Lysozyme was successfully back transfered at pH 12.2 and 1.0M KCl; trypsin at pH 12.6 and 0.5M KCl; and ${\alpha}-chymotrypsin$ at pH 6.7 and 0.5M KCl. In a test group separation experiments, complete separation of lysozyme from BSA could be obtained.

  • PDF

Characteristic Analysis of Flexibility and Muscle Strength according to Exercise using Lumbar Strengthen Exercise Instrument (요추강화 운동기기의 훈련을 통한 유연성 및 근력 특성 분석)

  • Kang, S.R.;Kim, K.;Jeong, G.Y.;Moon, D.A.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.53-61
    • /
    • 2010
  • In this paper, We investigated the characteristic analysis of flexibility and muscle strength for exercise to verify capacity in rehabilitation exercise of lumbar using lumbar strengthen exercise instrument. We have experiment in 20th years man and woman who are 20 subject with no medical history, we divided subjects into control group with no exercise and training group with lumbar strengthen exercise. We used Hi-Spine(Medicalscience.korea) also, provided exercise 40 minute a day, three days a week and progressed total four weeks. Moreover in our experiment, subjects exercised four postural position as lay down, sit, stand and stretch each ten minute. We measured trunk extension backward, trunk flexion forward, evaluation of based physical fitness and lumbar joint torque. The reults have shown that there more improved all for flexibility, based physical fitness and lumbar joint torque in training group than control group. We indicated that by rotating 3-D axis movement flatform of exercise instrument, muscle spindle in subject have been stimulated and these rotation direction and angle caused muscle tonus and contraction that makes muscle, flexibility and based physical fitness improve more. Our study can be used rehabilitation exercise program to aged people and patient with lumbar injury.

Validation of the Measure of Health Literacy for the Elderly (고령자의 건강정보이해능력(Health Literacy) 측정도구 타당화)

  • Chun, Heeran;Cho, Sung-il;Kim, Il-Ho
    • Korean Public Health Research
    • /
    • v.44 no.4
    • /
    • pp.99-109
    • /
    • 2018
  • Objective : Health literacy (HL) is, defined as "the degree to which individuals have the capacity to obtain, process, and understand basic health information and services needed to make appropriate health decisions." Being old is one of the main risk factors with limited health literacy. This study aims to adapt Chew's health literacy scale into the Korean language and validate the scale for the use of the elderly. Methods : Data were drawn from the '2016 Seoul Survey on Elderly Health and Functional Assessment, which includes a total of 725 people aged 60 to 79. The sample was randomly divided into two groups for reliability and validity tests of the modified Chew's scale of 8 items. The Korean version of the questionnaire was developed by group translation, expert reviews, and forward-backward translation. Exploratory and confirmatory factor analyses were conducted to assess and validate the factor structure of the scale. Results : Results suggest the two-factor structure ("Understanding" and "Applying" of HL) with 8 items. Exploratory factor analyses of the first sample (n=400) revealed that the internal reliability of the scale was high (Cronbach's ${\alpha}=.904$). Principal axis factoring extracted two factors ("Understanding" and "Applying" of HL) and explained 78.3% of total variance (KMO=.872, Bartlett's ${\chi}^2=2431.3$, df=28, p<.001). Confirmatory factor analysis of the second sample (n=325) was performed and the two-factor model was supported (GFI=.960, CFI=.979, TLI=.969, RMSEA=0.075). Conclusions : This study provides evidence for adequate criterion and validity of the health literacy scale for the community dwelling elderly in Korea.

A Study on Vibration & Noise Reduction of Fast Back Feeding Device for Manufacturing Process (제조공정용 Fast Back 이송장치 진동·소음 저감에 관한 연구)

  • Han, Doo-Hee;Lee, Seung-Hun;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.642-648
    • /
    • 2019
  • This paper presents a fast back-type transfer device for snack food processing that uses the inertia of transferred material. A conventional conveying system is a drive system that uses a belt conveyor and mechanical crank, which generate noise and vibration and cause environmental pollution. Vibration and noise are reduced in the proposed fast back feeding device by using a counterweight. The crank drive unit was replaced with a linear servomotor, and an equilibrium device was designed to balance the force due to acceleration. This makes it is possible to adjust the forward and backward speed and acceleration through PLC control. A vibration damper device offsets the vibration force of the periodic shock form. The main cause of the vibration was identified through vibration analysis, and reduction measures were established. We verified the effectiveness of the vibration by making a prototype and performing about 10 vibration tests. Because no mechanical transducer is needed, energy loss, noise, and vibration do not occur, and the operating speed is not limited.

Entries and Exits: Case Studies of the Foreign Direct Investment of Korean Consumer Electronics Chaebols in the European union (유럽연합(EU)내 한국 가전 대기업들의 진입과 퇴출)

  • Sung-Hoon Jung
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.2 no.1_2
    • /
    • pp.145-167
    • /
    • 1999
  • The aim the this paper is to explore the processes of three Korean consumer electronics chaebols'entries into, and exits from tile EU in the context of European integration and enlargement and at the global, regional(EU), national and local level. Korean FDI in the EU has increased sharply since the late 1980s, while interacting with the processes of European integration and enlargement. In particular, the chaebols'FDI was caused by reactions against the intensification of Euro-trade regulations. As a result, these defensive entries have led such chaebols to create a strategy of ‘defensive Europeanisation’through the formation of forward and backward linkages between chaebols’affiliates and Korean suppliers within the EU. Nonetheless, defensive FDI has given rise to exits through active relocation within and outside the EU, since the ‘late 1980s’due in the main to (1) sensitive reactions against changing EU trade regulations and (2) failures to maintain cost-competitiveness in particular host regions. Along with these trends, chaebols’entries and exits are placed in contingent and paradoxical structures of the global -regional - national-local nexus, which has resulted from the mismatch of different EU policies such as trade, inward investment and regional policies.

  • PDF

Presurgical Naso-Alveolar Molding Appliance for Unilateral Cleft Lip and Palate (편측성 순구개열 신생아 환자의 술전 비치조 정형장치)

  • Baek, Seung-Hak;Yang, Won-Sik;Kim, Sukwha
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.905-914
    • /
    • 1998
  • The goals of this study were to present presurgical naso-alveolar molding (PNAM) appliance in unilateral cleft lip and palate treatment and to evaluate the effects of PNAM appliance on alveolar molding. Samples were consisted of 4 unilateral cleft lip and palate infants (3 males and 1 female, mean age=23.2 days after birth) who were treated with PNAM appliances in Department of Orthodontics, Seoul National University Dental Hospital. Average alveolar cleft gap between the greater and lesser segment was 8.27mm and average duration of alveolar molding treatment was 9.7 weeks. These patients' models were obtained at initial visit (T1) and alter successful alveolar molding (T2). Seven linear and five angular variables were measured by using photometry and digital caliper. All statistical analyses were performed by SPSS win ver. 7.5 program. Paired t-test was used to compare the mean values. 1. The posterior part of alveolar segments are the stable structures during alveolar molding treatment period in infants. 2. Forward growth of the greater segment may be hindered by the action of alveolar molding. 3. The closure of cleft gap during alveolar molding were usually due to inward and backward bending of the anterior part of the greater segment and outward bending of the whole lesser segment.

  • PDF

Analysis of Regional Economic Ripple Effects of Port Logistics Industry in Gwangyang City - Focusing on Exogenous Specified Input-Output Model - (광양시 항만물류산업의 지역경제 파급효과 분석 - 외생화 산업연관모형을 중심으로 -)

  • Kim, Min-Seong;Na, Ju-Mong
    • Journal of Korea Port Economic Association
    • /
    • v.39 no.2
    • /
    • pp.77-95
    • /
    • 2023
  • The regional infrastructure industries of Gwangyang City, the subject of this study, are Gwangyang Port and Gwangyang Steel Mill. Therefore, it is necessary to analyze the regional economic ripple effects of the port logistics industry in Gwangyang City. In this study, a multi-stage approach using the RW and the LQ methodology using the national input-output tables in 2015 and 2019 is used to prepare the regional interindustry analysis chart in Gwangyang City, and an exogenous demand induction model that reclassified the port logistics industry was applied. Through this, the purpose of this study was to provide policy implications by figuring out the regional economic ripple effects of the port logistics industry quantitatively in Gwangyang City. As a result of the analysis, the industries with high production inducement effect and forward/backward linkage effect of the port logistics industry in Gwangyang City were analyzed as manufacturing, transportation, land and air logistics sectors. And the industries in which the added value inducement effect and the employment inducement effect were analyzed as an industry related to the service industry. Therefore, it is necessary to prepare support measures to foster the port logistics industry as a way to promote these industries and revitalize the local economy of Gwangyang City. To this end, it is desirable to improve policies and systems for the vitalization of the Gwangyang port maritime cluster and provide various policy support for the port logistics industry in Gwangyang City. This study is meaningful in suggesting policy implications for the regional economy of Gwangyang City based on the results of exogenous analysis of the port logistics industry in small and medium-sized cities. However, It seems that further studies related to this will be needed in the future.