A Study of Electromagnetic Actuator for Electro-pneumatic Driven Ventricular Assist Device

  • Jung Min Woo (Biomedical Engineering of Brain Korea 21 Program, Korea University, Korea Artificial Organ Center, Korea University) ;
  • Hwang Chang Mo (Biomedical Engineering, Korea University Medical College, Korea Artificial Organ Center, Korea University) ;
  • Jeong Gi Seok (Biomedical Engineering of Brain Korea 21 Program, Korea University, Korea Artificial Organ Center, Korea University) ;
  • Kang Jung Soo (Biomedical Engineering of Brain Korea 21 Program, Korea University, Korea Artificial Organ Center, Korea University) ;
  • Ahn Chi Bum (Biomedical Engineering of Brain Korea 21 Program, Korea University, Korea Artificial Organ Center, Korea University) ;
  • Kim Kyung Hyun (Biomedical Engineering of Brain Korea 21 Program, Korea University, Korea Artificial Organ Center, Korea University) ;
  • Lee Jung Joo (Biomedical Engineering of Brain Korea 21 Program, Korea University, Korea Artificial Organ Center, Korea University) ;
  • Park Yong Doo (Biomedical Engineering, Korea University Medical College, Korea Artificial Organ Center, Korea University) ;
  • Sun Kyung (Biomedical Engineering of Brain Korea 21 Program, Biomedical Engineering, Korea University, Biomedical Engineering, Korea University Medical College, Thoracic and Cardiovascular Surgery, Korea University Medical College, Korea University, Korea Artificial Organ Center, Korea University)
  • Published : 2005.12.01

Abstract

An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro­pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations. The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10mm. The actuator dimension was 120mm in diameter and 65mm in height with a mass of 1.4kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80bpm when the afterload was 100mmHg. The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro­pneumatic pump. The authors provide the above results as a preliminary data for further studies.

Keywords

References

  1. Oyerb PE, Stinson EB, Portner PM, Ream AK, and Shumway NE, 'Development of a totally implantable, electrically actuated left ventricular assist system', American J. Surgery, Vol. 140, pp. 17-25, 1980 https://doi.org/10.1016/0002-9610(80)90412-2
  2. Frazier OH, Myers TJ, Jarvik RK, Westaby S, Pigott DW, Gregoric ID, Khan T, Tamez DW, Conger JL, and Macris MP, 'Research and development of an implantable axial-flow left ventricular assist device: the Jarvik 2000 heart', Ann. Thorac. Surg., Vol. 71, pp. S125-132, 2001 https://doi.org/10.1016/S0003-4975(00)02614-X
  3. Konishi H, Yland MJ, Brown M, Yamazaki K, Macha M, Konishi R, Kerrigan JP, Zhang S, Randhawa PS, Antaki JF, Fuse K, and Kormos RL, 'Effect of Pulsatility and hemodynamic power on recovery of renal function', ASAIO J., Vol. 42, pp. M720-M723, 1996 https://doi.org/10.1097/00002480-199609000-00082
  4. Orime Y, Shiono M, Nakata K, Hata M, Sezai A, Yamada H, Iida M, Kashiwazaki S, Nemoto M, Kinoshita J, Kojima T, Saito T, and Sezai Y, 'The role of Pulsatility in end-organ microcirculation after cardiogenic shock', ASAIO J., Vol. 42, pp. M724-M729, 1996 https://doi.org/10.1097/00002480-199609000-00083
  5. Thomas DC, Butler KC, Taylor LP, Le Blanc P, Rintoul TC, Petersen TV, Griffith BP, Kormos RL, Borovetz HS, Litwak P, Kameneva MV, Choi S, Burgreen GW, Wu Z, and Antaki JF, 'Progress on development of the Nimbus-University of Pittsburgh axial flow left ventricular assist system', ASAIO J., Vol. 44, pp. M521-M524, 1998 https://doi.org/10.1097/00002480-199809000-00040
  6. Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, Tomioka J, Kormos RL, Griffith BP, and Kurosawa H, 'An implantable centrifugal blood pump for long term circulatory support', ASAIO J., Vol. 43, pp. M686-M691, 1997 https://doi.org/10.1097/00002480-199709000-00072
  7. S.H. Lee, K.H. Lee, S.S. Park, P.W. Seo, S.H. Kim, and B.J. Kang, 'In-vivo Evaluation of Pneumatic Ventricular Assist Device and Durability Improvement', J. Biomed. Eng. Res., Vol. 25(1), pp. 65-70, 2004
  8. Gernes DB, Clay WC, and Sherman CW, 'A torque-motor-actuated ventricular assist system, in Nose Y, Kjellstrand C, Ivanovich (P) eds, Progress in Artificial Organs-1985. Cleveland', ISAO Press, pp. 423-430, 1986
  9. Ramasamy N, Miller PJ and, Portner PM, 'Long-term studies with an electromechanical ventricular assist system in the calf and sheep, in Nose Y, Kjellstrand C, Ivanovich (P) eds, Progress in Artificial Organs-1985. Cleveland', ISAO Press, pp. 456-463, 1986
  10. Richenbacher WE, Pae WE Jr, Magovern JA, Rosenberg G Snyder AJ, and Pierce WS, 'Roller screw electric motor ventricular assist device', ASAIO J., Vol. 32, pp. 46-48, 1986
  11. Tominaga R, Smith W, Massiello A, Harasaki H, and Golding LA, 'Chronic nonpulsatile blood flow II Hemodynamic responses to progressive exercise in calves with chronic nonpulsatile biveniricular bypass', J. Thorac. Cardiovasc. Surg., Vol. 111, pp. 857-862, 1996 https://doi.org/10.1016/S0022-5223(96)70347-1
  12. Nishinaka T, Tatsumi E, Taenaka Y, Takano H, and Konayagi H, 'Morphologic changes of the aortic wall due to reduced systemic pulse pressure in prolonged nonpulsatile left heart bypass', ASAIO J., Vol. 43, pp. M691-M695, 1997 https://doi.org/10.1097/00002480-199709000-00072
  13. Park JW, Choi J, Lee JJ, Nam K, Chung J, Park SK, Park CY, Sun K, Kim WG, Kim J, and Min BG, 'AnyHeart: a single-piece heart-saving implantable artificial heart (BVAD)--monitoring and estimation', Int J. Artif. Organs, Vol. 26, No.5, pp. 406-10, 2003
  14. Samuels L, Entwistle J, Holmes E, Fitzpatrick J, and Wechsler A, 'Use of the AbioCor replacement heart as destination therapy for end-stage heart failure with irreversible pulmonary hypertension', J. Thorac. Cardiovasc. Surg., Vol. 128, No.4, pp. 643-5, 2004 https://doi.org/10.1016/j.jtcvs.2004.03.052
  15. Sun K, Son HS, Jung JS, Cheong BK, Shin JS, Kim KT, Lee HW, Ahn SS, Park SY, Oh HJ, Lee HS, Shim EB, Rho YR, Lee HS, Min BG, and Kim HM, 'Korean artificial heart (AnyHeart): an experimental study and the first human application', Artif. Organs