• 제목/요약/키워드: axis alignment

Search Result 234, Processing Time 0.028 seconds

Fabrication of Planar Type Inductor Using FeTaN Magnetic thin Films

  • Kim, Chung-Sik;Seok Bae;Jeong, Jong-Han;Nam, Seoung-Eui;Kim, Hyoung-June
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.532-538
    • /
    • 2000
  • A double rectangular spiral inductor is fabricated using FeTaN films. The inductor is composed of internal coils sandwiched by magnetic layers. Characteristics of inductor performance are investigated with an emphasis on planarization of magnetic films. In the absence of the planarization process, the grating topology of upper magnetic films over coil arrays degrades the soft magnetic properties and the inductor performance. It also induces a longitudinal magnetic anisotropy with the easy axis aligned to the magnetic flux direction. This alignment prevents the upper magnetic films from contributing to the total induction. Glass bonding is a viable method for achieving a completely planar inductor structure. The planar inductor with glass bonding shows excellent performance : inductance of 1.1 H, Q factor of 7 (at 5 MHz), and the dc current capability up to 100 mA.

  • PDF

Effect of Mirror Misalignments on Optical Ray Path In a Ring Resonator

  • Lee, Dong-Chan;Lee, Jae-Cheul;Son, Seong-Hyun;Cho, Hyun-Ju
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.121-127
    • /
    • 2002
  • The operating principal of a ring laser gyroscope depends on the phase difference for the counter-propagating waves within a closed path. The reflecting mirrors mounted on the monoblock form the traveling waves. The manufacturing accuracy of the monoblock influences the traveling path of ray, the sensitivity of laser resonator for misalignments, and diffraction losses. A 3 $\times$ 3 ray transfer matrix was derived for optical components with centering and squaring errors in a ring resonator. The matrix can be utilized to predict the optical ray paths on the basis of the manufacturing errors of the monoblock as well as the misalignment of mirrors. Then the distance and orientation (o. slope) at the arbitrary plane inside the resonator along the ideal optical path can be calculated from the chain multiplication of the ray transfer matrix for each optical component in one round trip. We also show that the counter-propagating rays In a ring resonator with errors does not coincide in each round trip, which results in gain difference between two beams, and how these errors can be adjusted through the alignment procedure. Finally this 3 $\times$ 3 ray matrix formalism can be used to calculate the beam size and its displacement from the optical axis and the deviation at the diaphragm.

Ellipsometric Expressions for Two Uniaxially Anisotropic Layers Coated on a Multilayered Substrate (두개의 단축이방성 박막이 있는 다층박막 시료의 타원식)

  • Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • Explicit expressions are derived for the effective reflection coefficients of obliquely incident light on a multilayered substrate coated with two uniaxially anisotropic films. Based on these reflection coefficients, ellipsometric constants are obtained as function of the tilt and azimuthal angles of the optical axes of the uniaxial films. Explicit expressions are provided, which can be used to separate the effects of surface anisotropy for anisotropic film from that of its bulk anisotropy, so that these expressions may be utilized in characterizing the surface anisotropy of alignment layers.

Based on morphology and molecular data, Palisada rigida comb. nov. and Laurencia decussata comb. et stat. nov. (Rhodophyta, Rhodomelaceae) are proposed

  • Metti, Yola
    • ALGAE
    • /
    • v.37 no.1
    • /
    • pp.15-32
    • /
    • 2022
  • Inspecting herbaria collections of Laurencia rigida highlighted frequent misidentifications between L. rigida and L. heteroclada f. decussata, two poorly studied taxa from Australia. Recent collections of DNA material, including from topotype material, allowed for re-examination of these two taxa using molecular techniques. Detailed morphological and molecular analyses based on two markers (rbcL and COI-5P) strongly supported these two taxa as being distinct from each other and requiring nomenclatural changes. Comprehensive morphological analyses highlighted features useful for accurate identifications. Interestingly, L. rigida was found to belong to the genus Palisada with evidence from both the morphology and molecular data. Therefore, this study proposed recognizing L. rigida as Palisada rigida comb. nov. Molecular data for L. heteroclada f. decussata on the other hand supported its separation from L. heteroclada, with too great a molecular distance to be considered a variety. Morphological characters that best separated P. rigida from L. decussata included seven characters; number of pericentral cells per vegetative axial segment, the presence of secondary pit connections, the presence of lenticular thickenings, tetrasporangia alignment, the presence of corps en cerise, holdfast morphology, and overall plant shape. Morphologically, L. heteroclada f. decussata was also separated from L. heteroclada, particularly by the following characteristics; ultimate branchlets morphologies, lower order branch lengths, primary axis and holdfast morphologies. Therefore, it was proposed that L. heteroclada f. decussata is recognized at a species level as L. decussata comb. et stat. nov.

Optical Design and Tolerance Analysis for UVO-Multiband Polarizing Imager System

  • Han, Jimin;Chang, Seunghyuk;Park, Woojin;Lee, Sunwoo;Ahn, Hojae;Kim, Geon Hee;Lee, Dae-Hee;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.68.2-68.2
    • /
    • 2020
  • UVO-Multiband Polarizing Imager System (UVOMPIS) is an ultraviolet to visible light multi-wavelength polarization/imaging system for Compact Advanced Satellite. We developed Linear Astigmatism Free-Three Mirror System (LAF-TMS) D200F2 as an optical system of UVOMPIS which has an entrance pupil diameter of 200 mm, a focal ratio of 2, a field of view of 2° × 4°. LAF-TMS is a confocal off-axis reflecting telescope system that removes linear astigmatism, and its all mirrors (M1, M2, M3) are optimized with the freeform surface to reduce high-order aberrations. Through the sensitivity analysis and Monte-Carlo simulation as the tolerance analysis, we can confirm the feasibility of the system, relatively sensitive parameters (tilt, decenter, despace, surface RMS error), and considerations for optomechanical design. From the sensitivity analysis, we can discover the relatively sensitive optical alignment parameters to a single perturbation. Further more, in the monte-carlo simulation, we investigate the minimum tolerance budget satisfying the required optical performance and whether the tolerance range is satisfied within manufacturing error.

  • PDF

A Study on the Microstructure and Properties of Y-BA-Cu-O/Ag composite High $T_{c}$ Superconductor prepared by Sinter-forging Process (Sinter forging으로 제조한 Y-BA-Cu-O/Ag 고온 초전도 복합체의 미세조직과 특성)

  • Park, Jong-Hyeon;Kim, Byeong-Cheol;Song, Jin-Tae
    • Korean Journal of Materials Research
    • /
    • v.4 no.1
    • /
    • pp.37-43
    • /
    • 1994
  • Y-Ra-Cu-0 oxide superconductors were fabricated by the sinter-forging method to make the critical current density improve through controlling of microstructure and crystal texture. The grain alignment of oxide superconductor was formed by the sinter-forging process and it's c-axis orientation was parallel to the press direction.The orientation factor of texture increased with sinking temperature and pressure, and also grain alignment was improved by the addition of Ag. As for the sinterforged Y-Ba-Cu-O/Ag sample, the $T_c$(on-set) was not almost varied with the sinter-forging temperature, but $T_c\;^{zero}$ decreased more or less at high sinter-forging temperatures. In addition, it was observed that added-Ag was mainly distributed along the grain boundar~es in the (123) matrix, resulting in the densification of microstructure. From these results, i t was thought that the improvement of $J_c$ over 2000A/$\textrm{cm}^2$ was attributed to the texture, densification of microstructure, and (123) grain growth due to the Ag addition.

  • PDF

Analysis of the Optical Measurement Error Induced by Vibration of the Optical Measurement Tower for Large Mirrors (대구경 반사경 광학측정용 타워의 진동에 의한 광학측정오차 분석)

  • Kang, Pilseong;Kim, Ohgan;Ahn, Hee Kyung;Yang, Ho-Soon
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.281-289
    • /
    • 2017
  • In the present research, the optical measurement error induced by vibration of the optical measurement tower for large mirrors at KRISS (Korea Research Institute of Standards and Science) is investigated. The vibrations of the tower structure, the interferometer, and the null lens are measured while the surface errors of the 600-mm-diameter on-axis aspheric mirror are measuring, under various environmental conditions. The increase of surface error induced by alignment error with respect to vibration is analyzed. As a result, the interferometer and the null lens, which are located on the top of the tower, are highly sensitive to vibration. Additionally, the surface error of the mirror is strongly increased when the vibration directions of the interferometer and the null lens are different. To reduce the alignment error and the surface error induced by vibration, the tower structure should be improved, to be insensitive to low-frequency vibration. Alternatively, optical measuring under stable conditions by vibration monitoring can improve the reliability of the surface error measurement.

Measurement of the Axial Displacement Error of a Segmented Mirror Using a Fizeau Interferometer (피조 간섭계를 이용한 단일 조각거울 광축방향 변위 오차 측정)

  • Ha-Lim, Jang;Jae-Hyuck, Choi;Jae-Bong, Song;Hagyong, Kihm
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.1
    • /
    • pp.22-30
    • /
    • 2023
  • The use of segmented mirrors is one of the ways to make the primary mirror of a spaceborne satellite larger, where several small mirrors are combined into a large monolithic mirror. To align multiple segmented mirrors as one large mirror, there must be no discontinuity in the x, y-axis (tilt) and axial alignment error (piston) between adjacent mirrors. When the tilt and piston are removed, we can collect the light in one direction and get an expected clear image. Therefore, we need a precise wavefront sensor that can measure the alignment error of the segmented mirrors in nm scale. The tilt error can be easily detected by the point spread image of the segmented mirrors, while the piston error is hard to detect because of the absence of apparent features, but makes a downgraded image. In this paper we used an optical testing interferometer such as a Fizeau interferometer, which has various advantages when aligning the segmented mirror on the ground, and focused on measuring the axial displacement error of a segmented mirror as the basic research of measuring the piston errors between adjacent mirrors. First, we calculated the relationship between the axial displacement error of the segmented mirror and the surface defocus error of the interferometer and verified the calculated formula through experiments. Using the experimental results, we analyzed the measurement uncertainty and obtained the limitation of the Fizeau interferometer in detecting axial displacement errors.

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

  • Jin, Hosang;Jesseph, Fredrick B.;Ahmad, Salahuddin
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the Varian Eclipse treatment planning system (TPS). An isocentrically mounted Sun Nuclear MapCHECK 2 diode array with 5 cm water-equivalent buildup was also used for the VMAT QAs and the measurements were compared to a composite dose plane from the Eclipse TPS. A ${\gamma}$ test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison at 1%/1 mm (dose difference/distance-to-agreement), 2%/2 mm, and 3%/3 mm criteria for both QA methods. The two-tailed paired Student's t-test was employed to analyze the statistical significance at 95% confidence level. The average ${\gamma}$ passing rates were greater than 95% at 3%/3 mm using both methods for all four energies. The differences in the average passing rates between the two methods were within 1.7% and 1.6% of each other when analyzed at 2%/2 mm and 3%/3 mm, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1 mm; the difference was lower for 8 MV and 10 MV. However, the differences were not statistically significant for all criteria and energies (p-values >0.05). The EPID-based QA showed large off-axis over-response and dependence of ${\gamma}$ passing rate on energy, while the MapCHECK 2 was susceptible to the MLC tongue-and-groove effect. The two fluence-based QA techniques can be an alternative tool of VMAT QA to each other, if the limitations of each QA method (mechanical sag, detector response, and detector alignment) are carefully considered.

Distal Tibial Articular Surface Angle in the Coronal Plane in Koreans (한국인의 관상면상 원위 경골 관절면 각의 측정)

  • Lee, Kyung-Tai;Kim, Jin-Su;Young, Ki-Won;Kim, J-Young;Cha, Seung-Do;Kim, Eung-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.56-59
    • /
    • 2006
  • Purpose: The purpose of this study is to find out the normal distal tibial articular surface angle in coronal plane in Koreans. This would be helpful as the basic data for ankle reconstruction after trauma or deformity correction. Materials and Methods: Weight bearing anteroposterior radiographs of 123 normal ankles were reviewed. A line parallel to the shaft of the tibia was made. Another line was drawn parallel to the articular surface of the distal tibia. The superolateral angle that subtended by these two lines was measured. Results: There were 72 males and 51 females. The mean age overall was 35.7 years old. The mean age for males was 31.9 ($28{\sim}36$) years old. The mean age for females was 41.1 ($37{\sim}45$) years old. The mean distal tibial articular surface angle was $90.8^{\circ}$. The mean distal tibial articular surface angle for males was $91.5^{\circ}$ and for females $89.9^{\circ}$. Conclusion: The mean distal tibial articular surface angle in coronal plane for Koreans is $90.8^{\circ}$. We can avoid the error of the varization at the ankle alignment when the correction was performed vertical or minimal valgus to tibia tuberosity axis in Korean people.

  • PDF