• 제목/요약/키워드: axial compressive test

검색결과 248건 처리시간 0.022초

Experimental study on axial compressive behavior of hybrid FRP confined concrete columns

  • Li, Li-Juan;Zeng, Lan;Xu, Shun-De;Guo, Yong-Chang
    • Computers and Concrete
    • /
    • 제19권4호
    • /
    • pp.395-404
    • /
    • 2017
  • In this paper, the mechanical property of CFRP, BFRP, GFRP and their hybrid FRP was experimentally studied. The elastic modulus and tensile strength of CFRP, BFRP, GFRP and their hybrid FRP were tested. The experimental results showed that the elastic modulus of hybrid FRP agreed well with the theoretical rule of mixture, which means the property of hybrid composites are linear with the volumes of the corresponding components while the tensile strength did not. The bearing capacity, peak strain, stress-strain relationship of circular concrete columns confined by CFRP, BFRP, GFRP and hybrid FRP subjected to axial compression were recorded. And the confinement effect of hybrid FRP on concrete columns was analyzed. The test results showed that the bearing capacity and ductility of concrete columns were efficiently improved through hybrid FRP confinement. A strength model and a stress-strain relationship model of hybrid FRP confined concrete columns were proposed. The proposed stress-strain model was shown to be capable of providing accurate prediction of the axial compressive strength of hybrid FRP confined concrete compared with Teng et al. (2002) model, Karbhari and Gao (1997) model and Miyachi et al. (1999) model. The modified stress-strain model was also suitable for single FRP confinement cases and it was so concise in form and didn't have piecewise fitting, which would be easy for use in structural design.

Axial load-strain relationships of partially encased composite columns with H-shaped steel sections

  • Bangprasit, Papan;Anuntasena, Worakarn;Lenwari, Akhrawat
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.51-66
    • /
    • 2022
  • This paper presents the axial compression behavior of partially encased composite (PEC) columns using H-shaped structural steel. In the experimental program, a total of eight PEC columns with H-shaped steel sections of different flange and web slenderness ratios were tested to investigate the interactive mechanism between steel and concrete. The test results showed that the PEC columns could sustain the load well beyond the peak load provided that the flange slenderness ratio was not greater than five. In addition, the previous analytical model was extended to predict the axial load-strain relationships of the PEC columns with H-shaped steel sections. A good agreement between the predicted load-strain relationships and test data was observed. Using the analytical model, the effects of compressive strength of concrete (21 to 69 MPa), yield strength of steel (245 to 525 MPa), slenderness ratio of flange (4 to 10), and slenderness ratio of web (10 to 25) on the interactive mechanism (Kh = confinement factor for highly confined concrete and Kw = reduction factor for steel web) and ductility index (DI = ratio between strain at peak load and strain at proportional load) were assessed. The numerical results showed that the slenderness of steel flange and yield strength of steel significantly influenced the compression behavior of the PEC columns.

Strength model for square concrete columns confined by external CFRP sheets

  • Benzaid, Riad;Mesbah, Habib Abdelhak
    • Structural Engineering and Mechanics
    • /
    • 제46권1호
    • /
    • pp.111-135
    • /
    • 2013
  • An experimental study has been carried out on square plain concrete (PC) and reinforced concrete (RC) columns strengthened with carbon fiber-reinforced polymer (CFRP) sheets. A total of 78 specimens were loaded to failure in axial compression and investigated in both axial and transverse directions. Slenderness of the columns, number of wrap layers and concrete strength were the test parameters. Compressive stress, axial and hoop strains were recorded to evaluate the stress-strain relationship, ultimate strength and ductility of the specimens. Results clearly demonstrate that composite wrapping can enhance the structural performance of square columns in terms of both maximum strength and ductility. On the basis of the effective lateral confining pressure of composite jacket and the effective FRP strain coefficient, new peak stress equations were proposed to predict the axial strength and corresponding strain of FRP-confined square concrete columns. This model incorporates the effect of the effective circumferential FRP failure strain and the effect of the effective lateral confining pressure. The results show that the predictions of the model agree well with the test data.

내진보강된 치장조적벽의 파괴특성과 전단강도 (Shear Strength and Failure Mode of Architectural Masonry Walls)

  • 진희종;한상환;박영미
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.89-92
    • /
    • 2008
  • 본 연구는 조적조로 구성된 치장벽체의 전단거동에 관한 연구이다. 치장조적벽체의 내진보강상 세를 소개하였으며, 본 연구에서 개발한 내진상세를 적용하여 전단거동을 평가하였다. 실험체는 비보 강조적벽(URM) 1개 보강조적벽(RM) 3개로 구성하였으며, 준정적 실험을 수행하였다. 비보강 조적벽은 형상비와 축방향 압축력에 따라 다양한 거동 및 파괴가 일어난다. 그러나 본 연구는 조적구조와는 다른 치장조적조를 대상으로 하였으므로, 전단강도의 주요변수로 작용하는 축방향 압축력은 변수에서 제외 되었다. 실험변수로는 벽체의 보강유무와 형상비로 정하였다. 실험결과 실험체의 거동은 강체회전(Rocking)모드가 지배적으로 나타났으나, 최종파괴는 여러 파괴모드가 복합적으로 나타났다. FEMA273 에서는 면내조적벽의 전단강도식을 제시한다. 강도식은 조적벽의 거동모드에 따라 4가지로 분류되며, 그 거동모드는 강체회전(Rocking), 단부압괴(Toe-Crushing), 수평줄눈미끄러짐(Bed-Joint-Sliding), 사인장(Diagonal-Tension)파괴로 나타내고 있다. FEMA 273에 의해 전단강도를 평가한 결과 치장조적벽의 거동모드는 어느정도 예측 할 수 있었지만, 전단강도는 매우 다르게 나타났다.

  • PDF

유한차분법을 이용한 말뚝의 하중전이특성 및 해석기법 (Analytical Technique and Load Transfer Features on Pile Using Finite Difference Method)

  • 한중근;이재호
    • 한국환경복원기술학회지
    • /
    • 제9권5호
    • /
    • pp.10-21
    • /
    • 2006
  • For analyze of the bearing capacity, skin friction and settlements of pile on axial compressive loading, both Load transfer tests of pile and pile loading test in field have application to commonly before pile installing. A bearing capacity of pile was affected by the characteristics of surrounding ground of pile. Especially, that is very different because of evaluation of settlement due to each soil conditions of ground depths. The ground characteristics using evaluation of bearing capacity of pile through load transfer analysis depends on N values of SPT, and then a bearing capacity of pile installed soft ground and refilled area may be difficult to rational evaluation. An evaluation of bearing capacity on pile applied axial compressive loading was effected by strength of ground installed pile, unconfined compressive strength at pile tip, pile diameter, rough of excavated surface, confining pressure and deformation modules of rock etc and these are commonly including the unreliability due to slime occurred excavation works. Load transfer characteristics considered ground conditions take charge of load transfer of large diameter pile was investigated through case study applied load transfer tests. To these, matrix analytical technique of load transfer using finite differential equation developed and compared with the results of pile load test.

Analytical study of concrete-filled steel tubular stub columns with double inner steel tubes

  • Pouria Ayough;Yu-Hang Wang;Zainah Ibrahim
    • Steel and Composite Structures
    • /
    • 제47권5호
    • /
    • pp.645-661
    • /
    • 2023
  • Concrete-filled steel tubular columns with double inner steel tubes (CFST-DIST) are a novel type of composite members developed from conventional concrete-filled steel tubular (CFST) columns. This paper investigates the structural performance of circular CFST-DIST stub columns using nonlinear finite element (FE) analysis. A numerical model was developed and verified against existing experimental test results. The validated model was then used to compare circular CFST-DIST stub columns' behavior with their concrete-filled double skin steel tubular (CFDST) and CFST counterparts. A parametric study was performed to ascertain the effects of geometric and material properties on the axial performance of CFST-DISTs. The FE results and the available test data were used to assess the accuracy of the European and American design regulations in predicting the axial compressive capacity of circular CFST-DIST stub columns. Finally, a new design model was recommended for estimating the compressive capacity of CFST-DISTs. Results clarified that circular CFST-DIST columns had the advantages of their CFST counterparts but with better ductility and strength-to-weight ratio. Besides, the investigated design codes led to conservative predictions of the compressive capacity of circular CFST-DIST columns.

3차원 구성관계를 고려한 FRP-구속 콘크리트의 압축거동 예측모델 (Prediction of Compressive Behavior of FRP-Confined Concrete Based on the Three-Dimensional Constitutive Laws)

  • 조창근;권민호
    • 콘크리트학회논문집
    • /
    • 제16권4호
    • /
    • pp.501-509
    • /
    • 2004
  • 제안된 모델은 FRP 구속 콘크리트에 대한 압축거동 예측을 위한 것이다. FRP로 구속된 콘크리트의 모델링을 위하여, 3축 응력상태의 콘크리트 아탄성 구성관계를 제시하였다. FRP 구속에 따른 콘크리트 강도 증진은 3축 응력공간의 파괴기준에 따라 결정되며, 이에 대응하는 최대 압축변형률은 본 연구에서 제안된 변형률 증진계수로부터 결정된다. 따라서, 기존의 모델들이 하중단계에 관계없이 구속조건이 초기부터 파괴까지 일정하게 고려되는 반면에, 제안된 모델은 FRP로 구속된 콘크리트의 구속현상을 하중단계에 의존적인 비선형 관계로 제시하였다. FRP 층은 2차원의 적층된 복합재료의 해석에 기초하여 모델링되었다. 개발된 해석모델은 증분법에 의한 압축거동실험에 대한 해석을 수행할 수 있도록 하였다. FRP로 구속된 콘크리트 실린더의 대한 여러 연구자들의 실험 결과와 본 예측모델을 비교한 결과, 제안된 모델은 축방향 변형 뿐만 아니라 횡방향 변형을 포함하여 FRP 층으로 인한 콘크리트의 구속효과의 증진에 관한 거동 특성들을 잘 예측해 주었다.

Axial compressive behavior of concrete-encased CFST stub columns with open composite stirrups

  • Ke, Xiaojun;Ding, Wen;Liao, Dingguo
    • Advances in concrete construction
    • /
    • 제12권5호
    • /
    • pp.399-409
    • /
    • 2021
  • The existing method to improve the coordination performance of the inner and outer parts of concrete-encased concrete-filled steel tube (CFST) composite columns by increasing the volume-stirrup ratio causes difficulties in construction due to over-dense stirrups. Thus, this paper proposes an open polygonal composite stirrup with high strength and high ductility CRB600H reinforced rebar, and seventeen specimens were constructed, and their axial compressive performance was tested. The main parameters considered were the volume-stirrup ratio, the steel tube size, the stirrup type and the stirrup strength. The test results indicated: For the specimens restrained by open octagonal composite stirrups, compared with the specimen of 0.5% volume-stirrup ratio, the compressive bearing capacity increased by 14.6%, 15.7% and 21.5% for volume-stirrup ratio of 0.73%, 1.07% and 1.61%, respectively. For the specimens restrained by open composite rectangle stirrups, compared with the specimen of 0.79% volume-stirrup ratio, the compressive bearing capacity increased by 7.5%, 6.1%, and -1.4% for volume-stirrup ratio of 1.12%, 1.58% and 2.24%, respectively. The restraint ability and the bearing capacity of the octagonal composite stirrup are better than other stirrup types. The specimens equipped with open polygonal composite stirrup not only had a higher ductility than those with the traditional closed-loop stirrup, but they also had a higher axial bearing capacity than those with an HPB300 strength grades stirrup. Therefore, the open composite stirrup can be used in practical engineering. A new calculation method was proposed based on the stress-strain models for confined concrete under different restrain conditions, and the predicted value was close to the experimental value.

Axial behavior of RC column strengthened with SM-CFST

  • Jiang, Haibo;Li, Jiahang;Cheng, Quan;Xiao, Jie;Chen, Zhenkan
    • Steel and Composite Structures
    • /
    • 제43권6호
    • /
    • pp.773-784
    • /
    • 2022
  • This paper aims to investigate the axial compressive behavior of reinforced concrete (RC) columns strengthened with self-compacting and micro-expanding (SM) concrete-filled steel tubes (SM-CFSTs). Nine specimens were tested in total under the local axial compression. The test parameters included steel tube thickness, filling concrete strength, filling concrete type and initial axial preloading. The test results demonstrated that the initial stiffness, ultimate bearing capacity and ductility of original RC columns were improved after being strengthened by SM-CFSTs. The ultimate bearing capacity of the SM-CFST strengthened RC columns was significantly enhanced with the increase of steel tube thickness. The initial stiffness and ultimate bearing capacity of the SM-CFST strengthened RC columns were slightly enhanced with the increase of filling concrete strength. However, the effect of filling concrete type and initial axial preloading of the SM-CFST strengthened RC columns were negligible. Three equations for predicting the ultimate bearing capacity of the SM-CFST strengthened RC columns were compared, and the modified equation based on Chinese code (GB 50936-2014) was more precise.

축력과 반복횡력을 받는 고강도 R/C기둥의 연성거동 확보 (The Ductile Behavior of High-Strength R/C Columns Subjucted to Reversed Cyclic and Axial Loads)

  • 신성우;이지영;한범석;안종문;이광수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.507-512
    • /
    • 1998
  • An experimental investigation was conducted to examine the behavior of high strength R/C columns subjected to reversed cyclic and axial loads and to find the relationship between amounts of lateral reinforcement and axial loads ratios. The test parameters of column specimens were the compressive strength of concrete($f`_c$=250, 320, 460, $517kg/\textrm{cm}^2), $ the yield strength of longitudinal steel($f_y$=3700, $5254kg/\textrm{cm}^2), $ axial load ratio(0.3, 0.5, 0.6$f`_cA_g$). The results indicated that axial load can significantly affect and alter the behavior of HS R/C column under inelastic cyclic loadings. Also we found that the relationship between amounts of lateral reinforcement and axial load ratios was $\rho$ =(0.37η+0.15)f`/f.

  • PDF