• Title/Summary/Keyword: average spacing

Search Result 208, Processing Time 0.02 seconds

An Empirical Study on Clothing Distribution Center to Improve Storage Efficiency : Especially on Hanger Rack Storage According to Distance between Columns (의류 물류센터 보관효율 향상을 위한 실증적 연구 : 행거 랙 보관과 건물기둥 간격을 중심으로)

  • Nam, Hee Dae
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.75-80
    • /
    • 2019
  • Sales of the Korean clothing industry grew to 16.9 percent on-year in 2010, but the growth rate dropped to 3 percent from 2011 to 2016 and the overall market began to slump to 1.1.6 percent in 2017. The competitiveness of clothing companies is also a major sector in logistics capability, and the average logistics cost of domestic clothing companies is 8.3 percent of sales in 2011, higher than the average 8 percent of domestic industries, and 36.4 percent of the total storage cost in 2011, higher than the 28.8 percent share of the total storage cost of domestic companies. As domestic production conditions such as wage hikes and labor disputes worsened in the 1990s, production facilities were rapidly moved overseas, which led many clothing companies to have no production facilities or a minimal production base in Korea and focus on marketing and design capabilities. The total storage capacity and storage efficiency of the logistics center became very important as the products were changed to the form of mass warehousing and small-volume forwarding. Research shows that building column spacing, a model of this research, can affect the amount of hanger rack storage empirically, so for sustainable growth of clothing companies, it is necessary to improve competitiveness in the logistics market by reducing costs and improving efficiency to overcome difficulties in corporate management. Because logistics costs are 8.3 percent and operating profit to sales ratio is 2 percent, it is expected that operating profit will increase by 41.5 percent if logistics costs are reduced by 10 percent. If 10% of storage cost is saved based on storage cost, operating profit is expected to increase by 15% To strengthen the competitiveness of the clothing industry, a reduction in logistics costs is essential. Therefore, the purpose of this study is to provide hints that logistics experts can have empirically small amounts in reducing storage costs through column spacing adjustment of logistics centers that have not been dealt with statistically until now, and to contribute to the continued growth of clothing companies and the development of the domestic logistics industry.

Strengths of Lap Splices Anchored by SD600 Headed Bars (겹침이음 실험을 통한 SD600 확대머리철근의 정착강도 평가)

  • Chun, Sung-Chul;Lee, Jin-Gon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.217-224
    • /
    • 2013
  • Design provisions for the development length of headed bars in ACI 318-08 include concrete compressive strength and yield strength of headed bars as design parameters but do not consider the effects of transvers reinforcement. In addition, they have very strict limitation for clear spacing and material strengths because these provisions were developed based on limited tests. In this study, splice tests using SD600 headed bars with $2d_b$ clear spacing and transverse reinforcement were conducted. Test results show that unconfined specimens failed due to prying action and bottom cover concrete prematurely spalled. The contribution of head bearing on the anchorage strength is only 15% on average implying that unconfined specimens failed before the head bearing was not sufficiently developed. Confined specimens with stirrups placed along whole splice length have enhanced strengths in bearing as well as bond because the stirrups prevented prying action and improved bond capacity. Bond failure occurred in locally confined specimens where stirrups were placed only at the ends of splice length. The stirrups at ends of splice lengths can prevent prying action but the bond capacity did not increase. From regression analysis of test results, an equation to predict anchorage strength of headed bars was developed. The proposed equation consists of bond and bearing contributions and includes transverse reinforcement index. The average ratio of tests to predictions is 1.0 with coefficient of variation of 6%.

The Morphologic Characteristics of Step-pool Structures in a Steep Mountain Stream, Chuncheon, Gangwon-do (강원도 춘천시 근교의 산지계류에 형성된 계단상 하상구조의 특징)

  • Kim, Suk Woo;Chun, Kun Woo;Park, Chong Min;Nam, Soo Youn;Lim, Young Hyup;Kim, Young Seol
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.202-211
    • /
    • 2011
  • The geometric characteristics of step-pool structures and how they are influenced by channel characteristics were investigated in a steep mountain stream in the Experimental Forests of Kangwon National University in Chuncheon, Gangwon-do. Average values of steps for the study reaches were as follows: step spacing, 4.69 m; step height, 0.47 m; step drop, 0.71 m; step-forming particle sizes, 0.68 m; number, 21steps/ 100 m; the ratio of step spacing to channel width, 0.5; and step steepness, 0.13. Relationships between spacing and height of steps and channel gradient showed a negative- and positive correlation, respectively, whereas all geometric variables of steps manifested poor correlation with channel width. Therefore, step steepness, expressed as the ratio of step height to step spacing, increased as channel gradient increased. The ratio of step steepness to channel gradient representing the criterion of maximum flow resistance was 1.2, indicating the channel bed's stable condition. In particular, the relationship between the ratio of step drop to step height and channel gradient showed a significant negative correlation, suggesting the influence of step-pool geometry in trapping sediment and providing an aquatic habitat. Positive correlations also exist between spacing and drop of steps and step particles. Our findings suggest that the dynamics of step-pool structures may strongly control physical and ecological environments in steep mountain streams, so understanding them is essential for stream management.

A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation (박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Rhee, Han-Cheol;Cheong, Jae-Woan;Choi, Gyeong Lee
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.

Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow (초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 요철이 설치된 유출면에서의 열/물질전달 특성)

  • Rhee, Dong-Ho;Nam, Yong-Woo;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.338-348
    • /
    • 2004
  • The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.

Splice Length of GFRP Rebars Based on Flexural Tests of Unconfined RC Members (RC 부재 휨 실험에 의한 GFRP 보강근의 이음길이 제안)

  • Choi, Dong-Uk;Chun, Sung-Chul;Ha, Sang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.65-74
    • /
    • 2009
  • Glass fiber reinforced polymer (GFRP) bars are sometimes used when corrosion of conventional reinforcing steel bar is of concern. In this study, a total of 36 beams and one-way slabs reinforced using GFRP bars were tested in flexure. Four different GFRP bars of 13 mm diameter were used in the test program. In most test specimens, the GFRP bars were lap spliced at center. All beams and slabs were tested under 4-point loads so that the spliced region be subject to constant moment. Test variables were splice lengths, cover thicknesses, and bar spacings. No stirrups were used in the spliced region so that the tests result in conservative bond strengths. Average bond stresses that develop between GFRP bars and concrete were determined through nonlinear analysis of the cross-sections. An average bond stress prediction equation was derived utilizing two-variable linear regression. A splice length equation based on 5% fractile concept was then developed. As a result of this study, a rational equation with which design splice lengths of the GFRP bars can be determined, was proposed.

Ni/Si/Ni Ohmic contacts to n-type 4H-SiC (Ni/Si/Ni n형 4H-SiC의 오옴성 접합)

  • Lee, J.H.;Yang, S.J.;Noh, I.H.;Kim, C.K.;Cho, N.I.;Jung, K.H.;Kim, E.D.;Kim, N.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.197-200
    • /
    • 2001
  • In this letter, we report on the investigation of Ni/Si/Ni Ohmic contacts to n-type 4H-SiC. Ohmic contacts have been formed by a vacuum annealing and $N_2$ gas ambient annealing method at $950^{\circ}C$ for 10 min. The specific contact resistivity ( $\rho_{c}$ ), sheet resistance($R_s$), contact resistance($R_c$), transfer length($L_T$) were calculated from resistance($R_T$) versus contact spacing(d) measurements obtained from 10 TLM(transmission line method) structures. The resulting average values of vacuum annealing sample were $\rho_{c}=3.8{\times}10^{-5}\Omega cm^{3}$, $R_{c}=4.9{\Omega}$, $R_{T}=9.8{\Omega}$ and $L_{T}=15.5{\mu}m$, resulting average values of another sample were $\rho_{c}=2.29{\times}10^{-4}\Omega cm^{3}$, $R_{c}=12.9{\Omega}$ and $R_{T}=25.8{\Omega}$. The physical properties of contacts were examined using X-Ray Diffraction and Auger analysis, there was a uniform intermixing of the Si and Ni, migration of Ni into the SiC.

  • PDF

The Adsorptions and Configurations of CO Molecules on W (110) and W (100) Surface: Molecular Orbital Theory

  • Choe, Sang-Joon;Kang, Hae-Jin;Park, Dong-Ho;Huh, Do-Sung;Lee, Soon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.9
    • /
    • pp.1314-1320
    • /
    • 2004
  • The adsorption and configuration of CO molecules adsorbed on W (110) and W (100) surfaces have been calculated by the atomic superposition and electron delocalization molecular orbital (ASED-MO) method. Referred to as the ASED-MO method, it has been used in the present study to calculate the geometries, binding energies, vibrational frequencies, orbital energies, reduced overlap population (ROP), and charges. From these results adsorption properties of ${\alpha}$-state and ${\beta}$-state were deduced. The calculated binding energies are in good agreement with the experimental result. On the W (110), the calculated average binding energies are 2.56 eV for the end-on configuration and 3.20 eV for the lying-down configuration. Calculated vibrational frequency is 1927 $cm^{-1}$ at a 1-fold site and 1161 $cm^{-1}$ at a long-bridge (2) site. These results are in reasonable agreement with experimental values. On the W(100) surface, calculated average binding energies of the end-on and the lying-down are 2.54 eV and 4.02 eV respectively. The differences for binding energy and configuration on the surfaces are explained on the basis of surface-atom coordination and atom-atom spacing. In the favored lyingdown CO configuration on the W(110) and W(100) surfaces, 4 ${\sigma}$ and 1 ${\pi}$ donation interactions, coupled with the familiar 5 ${\sigma}$ donation to the surfaces and back-donations to the CO 2 ${\pi}^{\ast}$ orbital, are responsible for adsorption to the surface.

Identification of high-dip faults utilizing the GRM technique of seismic refraction method(Ⅱ) -Application to real data- (굴절파 GRM 해석방법을 응용한 고경사 단층 인지 (Ⅱ) -실제 자료 적용-)

  • Kim, Gi Yeong;U, Nam Cheol
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.1
    • /
    • pp.65-74
    • /
    • 1999
  • From refraction data along four seismic profiles near Eonyang which the Yangsan fault passes through, the Slope Variation Indicators (SVI) are computed and interpreted in terms of fault distribution. The average velocities of 2,250-2,870 m/s are estimated using velocity-analysis functions for the target boundary along those profiles. The average velocity for Line 1 is approximately 600 m/s lower than ones for the other lines. The SVI's with amplitude greater than or equal to 0.5 ms/m are turned out to be located near faults shown on the high-resolution reflection section, as closely as one station spacing (3 m). Large amplitude SVI's are densely distributed near National Road 35, and the fault having the largest vertical slip is indicated to be located approximately 930 m west of the inferred fault on the published geologic map.

  • PDF

Ni/Si/Ni Ohmic contacts to n-type 4H-SiC (Ni/Si/Ni n형 4H-SiC의 오옴성 접합)

  • 이주헌;양성준;노일호;김창교;조남인;정경화;김은동;김남균
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.197-200
    • /
    • 2001
  • In this letter, we report on the investigation of Ni/Si/Ni Ohmic contacts to n-type 4H-SiC. Ohmic contacts have been formed by a vacuum annealing and N$_2$ gas ambient annealing method at 950$^{\circ}C$ for 10 min. The specific contact resistivity($\rho$$\sub$c/), sheet resistance(R$\sub$S/), contact resistance(R$\sub$S/), transfer length(LT) were calculated from resistance(R$\sub$T/) versus contact spacing(d) measurements obtained from 10 TLM(transmission line method) structures. The resulting average values of vacuum annealing sample were $\rho$$\sub$c/=3.8x10$\^$-5/ Ω$\textrm{cm}^2$ , R$\sub$c/=4.9Ω, R$\sub$T/=9.8Ω and L$\sub$T/=15.5$\mu\textrm{m}$, resulting average values of another sample were $\rho$$\sub$c/=2.29x10$\^$-4/ Ω$\textrm{cm}^2$ , R$\sub$c/=12.9Ω, R$\sub$T/=25.8Ω. The Physical properties of contacts were examined using X-Ray Diffraction and Auger analysis, there was a uniform intermixing of the Si and Ni, migration of Ni into the SiC.

  • PDF