6 축 힘/모멘트센서를 이용한 구물체 잡기 손가락 힘측정장치 개발 (Development of Finger-force Measuring System with Six-axis Force/moment Sensor for Measuring a Spherical-object Grasping Force)

  • 김현민;윤정원;신희석;김갑순
    • 한국정밀공학회지
    • /
    • 제27권11호
    • /
    • pp.37-45
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis of their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by grasping a spherical object. At present, the used object in hospital is only a spherical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the spherical object measuring system which can measure the force of their fingers should be developed. In this paper, the finger-force measuring system with a six-axis force/moment sensor which can measure the spherical-object grasping force is developed. The six-axis force/moment sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (digital signal processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the average force of men was about 120N.

원통형 4손가락 힘측정시스템 개발 (Development of four-finger force measuring system of a cylindrical type)

  • 김갑순
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.349-355
    • /
    • 2010
  • Stroke patients, etc. can't use their hands because of the paralysis of their fingers, and their fingers could be recovered by rehabilitating training. In order to judge the rehabilitating extent of their fingers, the patients should grasp a cylindrical object in hospital. At present, the used object in hospital is only a cylindrical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the four-finger force measuring system which can measure the force of their fingers should be developed. In this paper, four-finger force measuring system with four force sensors which can measure the grasping force is developed. The force sensors are designed and fabricated, and the force measuring device is designed and manufactured by using DSP(digital signal processing). Also, the grasping force test of men is performed by using the developed four-finger force measuring system. It was confirmed that the finger average force of right hand is about 214.6 N and that of left hand is about 212.8 N.

3축 힘센서를 이용한 구물체 잡기 손가락 힘측정시스템 개발 (Development of finger-force measuring system with three-axis force sensor for measuring a spherical-object grasping force)

  • 김현민;김갑순
    • 센서학회지
    • /
    • 제19권3호
    • /
    • pp.238-245
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis of their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by grasping a spherical object. At present, the object used in hospital is only a spherical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the spherical object measuring system which can measure the force of their fingers should be developed. In this paper, the finger-force measuring system with a three-axis force sensor which can measure the spherical-object grasping force is developed. The three-axis force sensor is designed and fabricated, and the force measuring device is designed and manufactured using DSP(digital signal processing). Also, the grasping force test of men is performed using the developed finger-force measuring system, it was confirmed that the average force of men was about 120 N.

정방형 홈을 가진 회전원주 주위의 유동과 유체력 (Flow and Fluid Force around a Rotating Circular Cylinder with Square Grooves)

  • 강명훈;노기덕;공태희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1460-1465
    • /
    • 2004
  • Flow patterns around a rotating circular cylinder having square dimpled surface were visualized by the hydrogen bubble technique at velocity ratios from a=0 to 4.8 and Reynolds number of $Re=1.0{\times}10^{4}$. The wake region of the cylinder was reduced as the velocity ratios increase and was smaller than that of the smooth cylinder without dimples at the same velocity ratio. The hydrodynamic characteristics on the cylinder was investigated by measuring of lift and drag at velocity ratios from a=0 to 4.1 and Reynolds number from $Re=1.2{\times}10^{4}$ to $Re=2.0{\times}10^{4}$. As the velocity ratios increase, the average lift and drag coefficients were increased and at the same velocity ratio, the average lift was larger but the average drag was smaller than that of the smooth cylinder.

  • PDF

벽면근처에 놓인 정방형주의 유체력 제어 (Fluid Force Suppression of a Square Prism near Plane Wall)

  • 김광석;노기덕;강명훈;변용수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.61-62
    • /
    • 2006
  • The suppression of fluid force acting on a square prism near plane wall was studied by attaching fences on the comers of the prism. The height of the fence was 10% of the square width and the range of Reynolds number considered was $Re=2.0{\times}10^4$. The experimental parameters were the attaching position and numbers of fences, the space ratios $G/B(G/B=0.1{\sim}1.2)$ between prism and plane wall. The average drag coefficients were increased and the average hit coefficients were decreased and increased with the space ratios foulard plane wall. The drag of the prism was reduced average 7.6% with the space ratios by attaching the normal fence at the rear and upper comer and the horizontal normal fence at the rear and lower corner on the prism.

  • PDF

Measurement of the Space Radiation Dose for the Flight Aircrew at High-Altitude

  • Lee, Jaewon;Park, Inchun;Kim, Junsik;Lee, Jaejin;Hwang, Junga;Kim, Young-Chul
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권1호
    • /
    • pp.33-39
    • /
    • 2014
  • This paper describes an experimental approach to evaluate the effective doses of space radiations at high-altitude by combining the measured data from the Liulin-6K spectrometer loaded onto the air-borne RC-800 cockpit and the calculated data from CARI-6M code developed by FAA. In this paper, 15 exposed dose experiments for the flight missions at a high-altitude above 10 km and 3 experiments at a normal altitude below 4 km were executed over the Korean Peninsula in 2012. The results from the high-altitude flight measurements show a dramatic change in the exposed doses as the altitude increases. The effective dose levels (an average of $15.27{\mu}Sv$) of aircrew at the high-altitude are an order of magnitude larger than those (an average of $0.30{\mu}Sv$) of the normal altitude flight. The comparison was made between the measure dose levels and the calculated dose levels and those were similar each other. It indicates that the annual dose levels of the aircrew boarding RC-800 could be above 1 mSv. These results suggest that a proper procedure to manage the exposed dose of aircrew is required for ROK Air Force.

Design of a novel haptic mouse system

  • Choi, Hee-Jin;Kwon, Dong-Soo;Kim, Mun-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.51.4-51
    • /
    • 2002
  • $\textbullet$ A noval haptic mouse system is developed for human computer interface. $\textbullet$ Five bar mechanism is adapted for 2 dof force feedback with virtual environment. $\textbullet$ Double prismatic joint type mechanism is adapted to reflect 1 dof grabbing force feedback. $\textbullet$ Cable driven mechansim is used for actuation to reduce backlash and endow backdrivability. $\textbullet$ Virtual wall perception experiment is conducted to obtain force specification for haptic mouse. $\textbullet$ Average mouse workspace is measured using magnetic position tracker.

  • PDF

트로카 고정부에 작용하는 반력을 측정하여 수술도구 말단의 수직방향 상호작용 힘을 추정하는 방법 (Estimation of Vertical Interaction Force to the End of a Surgical Instrument by Measuring Reaction Force to the Trocar Support)

  • 김수용;김청준;이두용
    • 제어로봇시스템학회논문지
    • /
    • 제22권8호
    • /
    • pp.615-618
    • /
    • 2016
  • This paper proposes a method to estimate vertical interaction force to the end of the surgical instrument by measuring reaction force at the part supporting the trocar. Relation between the force to the trocar and the interaction force is derived using the beam theory. The vertical interaction force is modeled as a function of the reaction force to the trocar and the distance between the drape plate and the trocar. Experimental results show that error is induced by the asymmetric shape of the trocar tip because contact position between the instrument and the trocar tip is changed depending on the direction of the interaction force. The theoretical relation, therefore, is compensated and reduced. Average $L_2$ relative error of the estimated force in the x-direction and the y-direction is 5.81 % and 5.99 %, respectively.

군 급식에서 배식서비스에 미치는 영향요인 (Factors Related to Foodservice Satisfaction in Military Foodservice)

  • 여운승;이윤호
    • 대한영양사협회학술지
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2006
  • This study was intended to investigate and analyze the satisfaction of military meals service which was recognized by air force soldiers who were familiar to the society's meals service, and to make suggestions for the analysis results. For the study, the questionnaire survey was conducted for 460 air force soldiers who performed military duties in Chungcheong area for 23 days from June 3, 2003 to June 26, 2003. Total 460 copies of questionnaire were distributed. But, among them, 431 questionnaires except 29 copies which included dishonest and untrustful answers were analyzed for the study. In terms of the soldiers' rank in demographical characteristics, 43.2% (186 respondents) of total respondents were the airman first class, and 29.7% (128 soldiers) of total respondents were the airman second class. In terms of an education level, 66.1% (285 respondents) of total respondents had the undergraduate school or higher education level. Also, in terms of the growth area, 56.8% (245 respondents) of total respondents came from large cities. Among 20 items about the military meals service, in the question of cooking soldier's kindness degree, respondents answered that they were satisfied with the cooking solders' kindness at a medial level. The survey showed the average 2.95 in this item. The satisfaction level of actions taken at the lack of foods, was 2.94 on the average. Respondents answered that the soldiers' satisfaction on the actions taken at loss of foods was in the medial level. The average was 2.94 and respondents answered that this satisfaction was in the average level. In the item of daily menu placement, the average was 3.19. respondents showed the little higher satisfaction than the average. As the result of investigating whether the castor's seasoning materials were frequently replaced, there was the satisfaction of average level with 3.00 on the average. The satisfaction level of hot foods' temperature was 3.52 on the average. Respondents answered that they were relatively satisfied with the hot foods' temperature preservation. Also, the survey indicated that the nutritional satisfaction had the most influence.

  • PDF

손 힘 사용 측정 FSA 시스템의 성능 평가 (Evaluation of the FSA Hand Force Measurement System)

  • 정기효;유희천;권오채
    • 대한인간공학회지
    • /
    • 제24권2호
    • /
    • pp.45-49
    • /
    • 2005
  • The FSA(Force Sensitive Application) system measures hand force by using force resistance sensors. Compared to conventional hand force measurement systems such as Lafayette hand dynamometer and Jamar hydraulic hand dynamometer, the FSA system can be applied to analyze use of hand forces while the hand is manipulating objects for a task, However, the measurement performance of the FSA system has not been objectively evaluated. The present study tested the FSA system in terms of stability, repeatability, accuracy, and linearity. It is shown that the FSA system has good stability (CV$\leq$0.02) and linearity($R^2$=0.82), but has low repeatability(CV=$0.11{\sim}0.19$) and accuracy(22% of underevaluation on average). This performance result indicates that measurements from the FSA system should be used for relative comparison rather than for absolute comparison.