  • Marine algal flora and community structures were examined seasonally at three sites around the Shingori Nuclear Power Plant, Korea from February to November 2016. A total of 76 species were identified, including 9 green, 14 brown and 53 red algae. The greatest number of species occurred at Daesongri (51 species) followed by Sinamri (43 species) and at the discharge area (38 species) during the study period. Of the 76 seaweeds, 59 annuals and 17 warm tolerant species were recorded. Annual average biomass in dry weight varied from $168.02g/m^2$ at the discharge area to $222.53g/m^2$ at Sinamri. The coarsely branched form was the dominant functional form of seaweeds at the three sites. Seaweed community structures at the discharge site were distinguishable by decreasing species richness, biomass, species diversity index, richness index, and evenness index. The ratio of warm tolerance species and the dominance index values were remarkably higher at the discharge than those at the other sites.

Investigation on Oil-paper Degradation Subjected to Partial Discharge Using Chaos Theory

  • Gao, Jun;Wang, Youyuan;Liao, Ruijin;Wang, Ke;Yuan, Lei;Zhang, Yiyi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1686-1693
    • /
    • 2014
  • In this paper, oil-paper samples composed of transformer windings were used to investigate the insulation degradation process subjected to partial discharge (PD), with artificial defects inside to simulate the PD induced insulation degradation. To determine appropriate test voltages, the breakdown time obtained through a group of accelerated electrical degradation tests under high voltages was firstly fitted by two-parameter Weibull model to acquire the average breakdown time, which was then applied to establish the inverse power law life model to choose advisable test voltages. During the electrical degradation process, PD signals were synchronously detected by an ultra-high frequency (UHF) sensor from inception to breakdown. For PD analysis, the whole degradation process was divided into ten stages, and chaos theory was introduced to analyze the variation of three chaotic parameters with the development of electrical degradation, namely the largest Lyapunov exponent, correlation dimension and Komogorov entropy of PD amplitude time series. It is shown that deterministic chaos of PD is confirmed during the oil-paper degradation process, and the obtained results provide a new effective tool for the diagnosis of degradation of oil-paper insulation subjected to PD.

몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작 (Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers)

  • 이경렬;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

Influence of Plasma Discharge Power on the Electrical and Optical Properties of Aluminum Doped Zinc Oxide Thin Films

  • Moon, Yeon-Keon;Park, Jong-Wan
    • 한국재료학회지
    • /
    • 제16권6호
    • /
    • pp.346-350
    • /
    • 2006
  • Al-doped ZnO (AZO) thin films were grown on type of glass#1737 substrates by DC magnetron sputtering. The structural, electrical and optical properties of the films were investigated as a function of various plasma discharge power. The obtained films were polycrystalline with a hexagonal wurtzite structure and preferentially oriented in the (002) crystallographic direction. The lowest resistivity was $6.0{\times}10^{-4}{\Omega}cm$ with the carrier concentration of $2.69{\times}10^{20}cm^{-3}$ and Hall mobility of 20.43 $cm^2/Vs$. The average transmittance in the visible range was above 90%.

데이터 취득 시스템을 이용한 전력케이블의 부분방전 검출과 통계량 계산 (Partial Discharge Detection and Statistic Value Calculation of Power Cable Using Data Acquisition System)

  • 조경순
    • 한국컴퓨터산업학회논문지
    • /
    • 제3권12호
    • /
    • pp.1651-1658
    • /
    • 2002
  • 최근 들어 우리나라에서는 설치의 간편성과 높은 신뢰도를 가진 전력케이블의 사용이 증가하고 있다. 전력케이블은 출고 전에 IEEE std. 404-1993 시험을 거쳐 안정성을 확인하고 있지만 포설시 발생하는 접속부 내부의 결함으로 인하여 많은 문제가 발생하고 있다. 특히 불순물 혼입 또는 공극 발생시 고장율은 증가하게 된다. 부분방전 검출은 포설 후 전력케이블의 상태를 관측할 수 있는 유용한 방법이다. 본 연구에서는 부분방전 특성을 평가하고자 케이블 접속재인 EPR과 케이블 절연체인 XPLE 사이에 인공 결함을 발생시킨 후 데이터 취득 시스템을 이용하여 ${\varphi}$-q-n 특성을 검출하였으며, 부분방전의 정량적 해석을 위해 필요한 통계량인 최대방전전하량($q_{max}$), 평균방전 발생 펄스 수(${\={n}$), 평균 방전전하량(${\={q}$), ${\={n}$의 언밸런스 비와${\={q}$의 언밸런스 비를 계산하였다.

  • PDF

$SF_{6}$가스와 절연지의 절연계에서 가스압력에 따른 부분방전 현상(II) (Partial Discharge Phenomena with $SF_{6}$ Gas Pressures in Insulation Consisted of Insulation Paper and $SF_{6}$ Gas(II))

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권9호
    • /
    • pp.430-435
    • /
    • 2002
  • The $SF_{6}$ gas insulated power equipments have the insulation systems which are composed of $SF_{6}$ gas and insulation paper. It is repored that their insulation abilities are influenced by the $SF_{6}$ gas gaps in those insulation systems and gas pressures. This paper describes partial discharge phenomena with $SF_{6}$ gas pressures in insulation system of $SF_{6}$ gas-insulation paper Specimens of $SF_{6}$ gas-insulation paper were prepared and aramid paper was used as insulation paper. Partial discharge inception voltages(PDIV) and breakdown voltages for the existence of $SF_{6}$ gas gaps were measured by short term tests with gas pressures. Also, average PD quantities and pulse counts, life times of each specimens were calculated from the results of long term aging tests with gas pressures. It was found that the $SF_{6}$ gas gaps decrease increasing rates of PDIV and brealdown voltages according to gas pressure increase and the insulation breakdown caused by the smaller PD quantities than 1[pC] at the high gas pressure of 300kPa is due to the increase of energy density with increase of gas pressure.

LDPE에서 발생된 전기트리에 수반된 내부 부분방전 펄스 해석 (Electrical Pulses of Internal Partial Discharges Accompanying with Electrical Tree in LDPE)

  • 강성화;박영국;권순석;신태수;임기조
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.216-221
    • /
    • 1999
  • 전력용 케이블은 전선로의 지중화 추세에 따라 사용이 증가하고 있다. 케이블 절연체의 경우 장기간의 전압인가에 의해 열화 및 절연파괴 된다. 전력용 케이블의 절연파괴시 발생하는 사회/경제적 문제는 매우 심각한 것으로 알려져 있다. 절연체의 열화에 영향을 주는 요인은 매우 복잡하지만 그중에서도 전기트리 열화에 의한 파괴는 비교적 두꺼운 고체 유전체인 경우에 절연파괴 사고의 주된 원인이 되고 있다. 전기트리의 개시나 진전시 부분방전이 발생하므로 부분방전의 검출에 의해 전기트리의 발생 및 진전 양상을 관측할 수 있고 부분방전의 해석에 의해 절연재료의 잔여 수명을 예측할 수 있다. 본 논문에서는 고전압 전력용 케이블 절연재로써 광범위하게 사용되고 있는 저밀도 폴리에틸렌 시편에서의 전기트리 진전 양상을 비파괴 진단 기법에 의하여 검출하고자 내부 부분방전을 관측/해석하였다.

  • PDF

Carbon Nano-Powder Functionalization and Disperisibility with Plasma Discharge

  • 강유석;정만기;이덕연;송석균;김성인
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.491-491
    • /
    • 2013
  • A novel plasma system has been developed for 3-dimensional modification of the carbon nano-powders. Improvement of dispersion of these nano materials are studied by plasma discharge, not using chemical modification. The plasma process is considered to great advantages over wet chemical process due to environmental, economic viewpoint, and uniformity over the treated volume. The uniform dispersion is a critical factor for these material's nano composite applications. Using this plasma system, graphene, carbon black, and CNT was treated and functionalized. Several key discharge conditions such as Ar/H2/O2 or Ar/H2/NH3 gas ratio, treatment time, power, feeder's vibration frequency are investigated. Hydrophobic of graphene has turned some more into hydrophilic by reaction test with water, electrophoresis, surface contact angle test, and turbidity analysis. The oxygen content ratio in the plasma treated CNT has increased about 3.7 times than the untreatedone. In the case of graphene and carbon black, the oxygen- and nitrogen- content has been enhanced average 10%. O-H (N-H) peak, C-O (C-N) peak, and C=O (C=N) peak data have been detected by FTIR measurement and intensified compared to before-plasma treatment due to O2 or NH3 content.

  • PDF

부분방전 패턴인식을 위해 EMC센서를 이용한 최적화된 RBFNNs 분류기 설계 (Design of Optimized Radial Basis Function Neural Networks Classifier Using EMC Sensor for Partial Discharge Pattern Recognition)

  • 정병진;이승철;오성권
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1392-1401
    • /
    • 2017
  • In this study, the design methodology of pattern classification is introduced for avoiding faults through partial discharge occurring in the power facilities and local sites. In order to classify some partial discharge types according to the characteristics of each feature, the model is constructed by using the Radial Basis Function Neural Networks(RBFNNs) and Particle Swarm Optimization(PSO). In the input layer of the RBFNNs, the feature vector is searched and the dimension is reduced through Principal Component Analysis(PCA) and PSO. In the hidden layer, the fuzzy coefficients of the fuzzy clustering method(FCM) are tuned using PSO. Raw datasets for partial discharge are obtained through the Motor Insulation Monitoring System(MIMS) instrument using an Epoxy Mica Coupling(EMC) sensor. The preprocessed datasets for partial discharge are acquired through the Phase Resolved Partial Discharge Analysis(PRPDA) preprocessing algorithm to obtain partial discharge types such as void, corona, surface, and slot discharges. Also, when the amplitude size is considered as two types of both the maximum value and the average value in the process for extracting the preprocessed datasets, two different kinds of feature datasets are produced. In this study, the classification ratio between the proposed RBFNNs model and other classifiers is shown by using the two different kinds of feature datasets, and also we demonstrate the proposed model shows superiority from the viewpoint of classification performance.

직류 마이크로 할로우 음극 방전을 이용한 이단 마이크로 플라즈마 추력기의 배기 플룸의 형상 특성 (Shape Characteristics of Exhaust Plume of Dual-Stage Plasma Thruster using Direct-Current Micro-Hollow Cathode Discharge)

  • ;신지철
    • 한국추진공학회지
    • /
    • 제20권3호
    • /
    • pp.54-62
    • /
    • 2016
  • 이단 마이크로 할로우 음극 방전(MHCD) 플라즈마를 사용하는 마이크로 플라즈마 추력기(${\mu}PT$)에 대한 실험 연구가 수행되었다. 40 sccm의 아르곤 유량과 10 W 미만의 전력으로 보다 더 직진성 있고 긴 침투 길이를 가진 배기 플룸을 만드는 정전기적 가속이 이단 MHCD에 의해 발생되었다. 전압-전류 특성에서는 이단 운전 시 두 번째 단의 가속 전압이 일정하게 되는 최적 영역이 있음을 보였다. 추정된 배기 플룸의 길이가 가속 전압으로 추산된 이론적 배출 속도와 비슷한 증가 경향을 보였다. 다중 채널을 가진 마이크로 플라즈마 추력기는 동일한 총 전력량에 대하여 단일 채널 추력기와 비슷한 특성을 보여, 이는 채널 당 허용 전력량을 낮춰 전체 전력량을 높일 수 있음을 의미한다. 아르곤 원자 분광선의 볼츠만 그래프에서 배기 플룸의 평균 전자 여기 온도는 약 2.6 eV(=약 30,170 K)임이 확인되었다.