• Title/Summary/Keyword: auto calibration

Search Result 119, Processing Time 0.027 seconds

Development of Map-Based Engine Control Logic for DME Fuel (MAP 기반 DME용 엔진 제어로직 개발)

  • Park, Young-Kug;Chung, Jae-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3127-3134
    • /
    • 2013
  • This paper presents the verified results from the examination of the control algorithm, logic composition, and vehicle condition of the engine that has been adapted for DME fuel. It introduces the development process of the control structure and the logic control based on control map and auto-code generation, and finally verifies the reliability and performance of the overall control. The control structure largely consists of the injection control part that implements driver demand into an engine net torque and the air control system part that satisfies characteristics of exhaust gas and power performance. The control logic is designed with feedforward and feedback control for each of its control functions for an enhanced response. Moreover, the control map of the feedforward controller is created by the use of an engine model created by test data of mass product diesel engine, and it was subsequently calibrated in the test process of the engine and vehicle state. A test mode was completed by attaching the developed controller to the vehicle, and a reduction in gas emission is confirmed by the calibration of EGR, VGT, and injection times.

Laser imager의 성능관리에 대한 연구

  • Lee, Hyeong-Jin;In, Gyeong-Hwan;Lee, Won-Hong;Kim, Geon-Jung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.3 no.1
    • /
    • pp.126-132
    • /
    • 1997
  • Purpose : To apply to Program of Auto processor quality control after comparison of Film density variations with amendments to Auto density by using Check density program and Adjust density program of calibration mode into the Laser imager. Methods : Observe Check and Adjust density variations on the Control chart with standard step and value during seven months from December, 1995 to June, 1956 extending twice a week. (1) Measure density value on the steps after printing out 17-step sensitometric pattern of the Check density program. (2) In the same way, measure density values after amending density by using Adjust density program If they are exceeding allowable error limit. Results : In case of Check density program, the exceeding limit rates of Density difference(DD) and Middle density(MD) are: FL-IM3543 DD=75%. MD=72.5%, FL-IMD DD=0%. MD=30.8%(14.5%) After amending density by using Adjust density program, the exceeding limit rates of all both Laser imager were zero percent. The standard deviations are show lower FL-IM D than FL-IM3543 on the Check density control chart, but higher on the Adjust density control chart. Conclusion : (1) Check density variations by printingout sensitometric pattern extending once a week at least for quality control of the Laser imager. (2) In case of a dusty place, check the Laser beam transmission after cleaning Laser optical unit extending once a month. (3) Be sure to measure and check density values by using adjust density program if they are exceeding allowable error limit. (4) Maintain much better film density by performing the adjust density program even if check density values are existed within normal limit.

  • PDF

Thermal Stability of Photo-produced H3O+ in the Photolyzed Water-ice Film

  • Moon, Eui-Seong;Kang, Heon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.192-192
    • /
    • 2011
  • Hyperthermal ion scattering experiments were conducted with low kinetic energy (<35 eV) cesium ion beams to analyze the UV-photolyzed water-ice films. Neutral molecules (X) on the surface were detected as cesium-molecule ion clusters ($CsX^+$) which were formed through a Reactive Ion Scattering (RIS) process. Ionic species on the surface were desorbed from the surface via a low energy sputtering (LES) process, and were analyzed [1]. Using these methods, the thermal stability of hydronium ion ($H_3O^+$) that was produced by UV light was examined. As the thermal stability of $H_3O^+$ is related with the reaction, $H_3O^+$ + OH + $e^-$ (or $OH^-$) ${\rightarrow}$ $2H_2O$, which is similar or same with the reverse reaction of the auto-ionization of water, the result from this work would be helpful to understand the auto-ionization of $H_2O$ in water-ice that has not been well-understood yet. However, as $H_3O^+$ was not detected through a LES method, the titration experiment of $H_3O^+$ with methylamine ($CH_3NH_2$, MA), MA + $H_3O^+\;{\rightarrow}\;MAH^+$ + $H_2O$, was conducted. In this case, the presence of $MAH^+$ indicates that of $H_3O^+$ in the ice. Thus the pristine ice was photolyzed with UV light for a few minutes and this photolyzed ice was remained at the certain temperature for minutes without UV light. Then MA was adsorbed on that surface so that the population of $H_3O^+$ was found. From the calibration experiments, the relation of $MAH^+$ and $H_3O^+$ was found, so that the thermal stability of $H_3O^+$ can be investigated [2].

  • PDF

A Study on the Traffic Volume Correction and Prediction Using SARIMA Algorithm (SARIMA 알고리즘을 이용한 교통량 보정 및 예측)

  • Han, Dae-cheol;Lee, Dong Woo;Jung, Do-young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.6
    • /
    • pp.1-13
    • /
    • 2021
  • In this study, a time series analysis technique was applied to calibrate and predict traffic data for various purposes, such as planning, design, maintenance, and research. Existing algorithms have limitations in application to data such as traffic data because they show strong periodicity and seasonality or irregular data. To overcome and supplement these limitations, we applied the SARIMA model, an analytical technique that combines the autocorrelation model, the Seasonal Auto Regressive(SAR), and the seasonal Moving Average(SMA). According to the analysis, traffic volume prediction using the SARIMA(4,1,3)(4,0,3) 12 model, which is the optimal parameter combination, showed excellent performance of 85% on average. In addition to traffic data, this study is considered to be of great value in that it can contribute significantly to traffic correction and forecast improvement in the event of missing traffic data, and is also applicable to a variety of time series data recently collected.

Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra (NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.143-151
    • /
    • 1997
  • As the pulse heights from a NaI(Tl) detector vary with the temperature of the measuring environment a significant change in temperature may affect the energy calibration of the spectrometer. The auto-adjustment of the channel corresponding to a pulse heights can be achieved by introducing an external reference source to compensate the temperature dependency of pulse heights, but unfavorable increases of the Compton continuum are caused due to the external source. In this study, the total absorption peaks dominant in the typical environmental gamma spectrum-239 keV from $^{212}Pb$, 351 keV from $^{214}Pb$, 1460 keV from $^{40}K$ and 2614 keV from $^{208}Tl$ for examples - were used as reference in the correction of energy calibration. With these peaks, the program to calibrate the energy of the s spectrum was developed using Microsoft Visual Basic language. The program developed here was applied to the environmental spectra measured at intervals of 30 minutes in the temperature range of from $-20^{\circ}C$ to $10^{\circ}C$ to demonstrate the validity and applicability. As a result of the test, the correction scheme appeared to be effective in the temperature changes encountered in the usual environment.

  • PDF

Parameter Estimation of a Distributed Hydrologic Model using Parallel PEST: Comparison of Impacts by Radar and Ground Rainfall Estimates (병렬 PEST를 이용한 분포형 수문모형의 매개변수 추정: 레이더 및 지상 강우 자료 영향 비교)

  • Noh, Seong Jin;Choi, Yun-Seok;Choi, Cheon-Kyu;Kim, Kyung-Tak
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.11
    • /
    • pp.1041-1052
    • /
    • 2013
  • In this study, we estimate parameters of a distributed hydrologic model, GRM (grid based rainfall-runoff model), using a model-independent parameter estimation tool, PEST. We implement auto calibration of model parameters such as initial soil moisture, multipliers of overland roughness and soil hydraulic conductivity in the Geumho River Catchment and the Gamcheon Catchment using radar rainfall estimates and ground-observed rainfall represented by Thiessen interpolation. Automatic calibration is performed by GRM-MP (multiple projects), a modified version of GRM without GUI (graphic user interface) implementation, and "Parallel PEST" to improve estimation efficiency. Although ground rainfall shows similar or higher cumulative amount compared to radar rainfall in the areal average, high spatial variation is found only in radar rainfall. In terms of accuracy of hydrologic simulations, radar rainfall is equivalent or superior to ground rainfall. In the case of radar rainfall, the estimated multiplier of soil hydraulic conductivity is lower than 1, which may be affected by high rainfall intensity of radar rainfall. Other parameters such as initial soil moisture and the multiplier of overland roughness do not show consistent trends in the calibration results. Overall, calibrated parameters show different patterns in radar and ground rainfall, which should be carefully considered in the rainfall-runoff modelling applications using radar rainfall.

Waste Load Allocation Method for Total Maximum Daily Load Program of a Polluted River (수질오염총량관리제 대상 오염심화 하천에 대한 오염부하량 할당방법)

  • Cho, Jae-Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.2
    • /
    • pp.157-170
    • /
    • 2013
  • 수질오염총량관리제 시행 하천에 대해서는 객관적이고 과학적 방법으로 유역내 각 지역의 오염부하량을 할당할 필요가 있다. 본 연구에서는 대도시에서 배출되는 오염부하의 영향을 크게 받는 영산강수계의 중상류부를 대상으로 오염부하량 할당 방법에 대해 검토하였다. 오염부하량 할당을 위한 수질모델링은, 수질관리에 흔히 적용되어온 QUAL2E의 최근 판인, QUAL2Kw를 이용해서 수행하였다. 모델 적용 대상 지역의 각 reach의 수질매개변수는 QUAL2Kw의 자동보정 기능을 이용해서 추정하였다. 오염부하량 할당의 최적화는 유전알고리즘(genetic algorithm)을 이용하였고, 최소부하량 삭감법(least waste load removal allocation), 일정 부하량 이상 최소부하량 삭감법(least waste load removal over a certain value), 동일삭감률 할당법(equal removal rate)의 세가지 방법을 적용하고 비교 검토하였다. 동일삭감률 할당법은 다른 방법보다 유역 전체 부하량 삭감량이 훨씬 크기 때문에 효과적이지 않았고, 이 방법을 쓰기 위해서는 부하량 삭감대상인 각 소유역과 하수처리장을 그 규모와 특성에 따라 세분화할 필요가 있다. 동일삭감률 할당법의 적용시 세가지 범주로 나누어서 삭감률을 적용하였다. 오염부하량 삭감의 효율성을 감안할 때 최소 부하량 삭감법보다 일정 부하량 이상 최소부하량 삭감법이 더 적절한 것으로 검토되었다.

Measurements of Peroxyacetyl Nitrates at an Urban and a Rural Site in Korea (도시지역과 청정지역에서의 대기 중 PAN(PeroxyAcetyl Nitrate) 측정)

  • 김세웅;이강웅;김경렬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.157-167
    • /
    • 2001
  • Although PAN has ong been considered to belong to one of the most characteristic photooxidants, its concentra-tions have rarely been measured in a systematic manner in Korea. The first in-situ Measurements of PAN were made in concert with simultaneous analysis of NO, NO$_2$, $O_3$ and UV-Visible radiation intensity from Seoul and dong-Hae during Spring and early Summer of 1999. The aim of our study was to evaluate the behavior of photo-chemical species in a highly polluted urban air and a relative clean one. PAN were determined using a semi-auto-mated gas chromatograph equipped with an electron captured detection system. Calibration of the PAN was done by synthesizing liquid standards using a strong acid nitration of the corresponding peracid. The PAN concentra-tions were found in the range of a few ppbv in the urban air ad persistently less than a ppbv in the clean rural airs. Diurnal variations of PAN and $O_3$ were also observed consistently during the experiment with maxima occurring during the late daylight hours. While the positive dependency of $O_3$ production and PAN concentrations were ob-served in most occasion, the dependency became deviated significantly under changes in air masses.

  • PDF

Development and Application of Agricultural Reservoir Water Quality Simulation Model (ARSIM-rev) (농업용 저수지 수질모델 (ARSIM-rev) 개발 및 적용)

  • Haam, Jong Hwa;Kim, Dong Hwan;Kim, Hyung Joong;Kim, Mi-Ock
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.6
    • /
    • pp.65-76
    • /
    • 2012
  • Agricultural reservoir water quality simulation model (ARSIM-rev) was developed in this study for water quality simulation of a small and shallow agricultural reservoir with limited observed water quality data. Developed ARSIM-rev is a zero-dimensional water quality model because of little spatial differences in water quality between stations in a small and shallow agricultural reservoir. ARSIM-rev used same water quality reaction equations with WASP except for several equations, and daily based input parameters such as settling rate, release rate from sediment, and light extinction coefficient changed yearly based input parameters in ARSIM-rev. A number of pre- and post-processors were developed such as auto calibration and scenario analysis for ARSIM-rev. CE-QUAL-W2, WASP, and developed ARSIM-rev were applied to Mansu agricultural reservoir to evaluate model performance, and ARSIM-rev demonstrated similar model performance with CE-QUAL-W2 and WASP when low number of observed data was used for agricultural reservoir water quality simulation. Overall, developed ARSIM-rev was feasible for water quality simulation in a small and shallow agricultural reservoir with limited observed water quality data, and it can simulate agricultural reservoir water quality precisely enough like common water quality model such as CE-QUAL-W2 and WASP within a limited time.

Data processing of sensor output for correction of pressure measurement value of an anesthesia ventilator (마취기용 인공호흡기의 압력 측정값의 보정을 위한 센서 출력의 데이터 처리)

  • 박영준;이종수;김영길
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1067-1070
    • /
    • 1999
  • Anesthesia gas to pour to patients affects the flow and volume as the pressure difference of an oxygen and an anesthesia gas. An anesthesia gas, being injurious and polluting an environment, must control the pressure of an oxygen gas because of being used by closing up tight. But a pressure sensor to use for measuring an oxygen gas appears other pressure as the characteristic and the error difference of elements to use for implementing an system. A medical machine such as an anesthesia ventilator must be accurate because of using for the person's body. So we intend to implement an system for a sensor pressure measurement not to be change regardless of an environment. This papers is the target that a sensor pressrue measurement to be changed in environment is equal to actual sensor pressure measurement. So an implemented system is using analog filter and digital filter to reduce a noise. And we are using auto-zeroing and calibration to correct a sensor pressure which is changed in environment. Through such a process we increase the accuracy and the confidence of an anesthesia ventilator by controlling the flow of an anesthesia gas.

  • PDF