• Title/Summary/Keyword: attenuation measurement

Search Result 390, Processing Time 0.025 seconds

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

A Study on the Status and Prediction of Arterial Road Noise in Seoul, Korea (서울시 간선도로의 소음도 현황 및 예측식에 관한 고찰)

  • Park, Joon-Cheol;Kim, Yoon-Shin;Hong, Seung-Cheol;Choi, Joon-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.5
    • /
    • pp.395-402
    • /
    • 2008
  • Road traffic noise causes considerable disturbance and annoyance in exposed inhabitants. Particularly, arterial road noise is a significant environmental problem in many urban areas in which higher traffic volume and higher car speed occur. Arterial road noise became the target of this investigation in Seoul, South Korea. Noise levels were measured at four points that were based on distance from roadside at the same measurement site and under the conditions as reported by the National Institute of Environmental Research (NIER) in 1999. The average noise levels ($L_{eq,1h}$) of the arterial road was 80.3 dBA at 5 m, 77.4 dBA at 10 m, 73.7 dBA at 20 m, 70.9 dBA at 30 m. A comparison between 1999 and 2008's measurement values has shown that in 2008 noise level is up by about 1.5 dBA, traffic volume has increased by about 15.7%, while car speed has decrease by about 8%. The relationship between 2008' measured values and predicted values using the NIER Equation is low under 10 m from the roadside. The influence range of arterial noise is calculated at 26 m for road noise limits in daytime. In relation to the comparison between traffic volume and noise level, the equivalence in traffic volume (Light car+10xHeavy car) is higher than other variables.

Multiplexed Hard-Polymer-Clad Fiber Temperature Sensor Using An Optical Time-Domain Reflectometer

  • Lee, Jung-Ryul;Kim, Hyeng-Cheol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Optical fiber temperature sensing systems have incomparable advantages over traditional electrical-cable-based monitoring systems. However, the fiber optic interrogators and sensors have often been rejected as a temperature monitoring technology in real-world industrial applications because of high cost and over-specification. This study proposes a multiplexed fiber optic temperature monitoring sensor system using an economical Optical Time-Domain Reflectometer (OTDR) and Hard-Polymer-Clad Fiber (HPCF). HPCF is a special optical fiber in which a hard polymer cladding made of fluoroacrylate acts as a protective coating for an inner silica core. An OTDR is an optical loss measurement system that provides optical loss and event distance measurement in real time. A temperature sensor array with the five sensor nodes at 10-m interval was economically and quickly made by locally stripping HPCF clad through photo-thermal and photo-chemical processes using a continuous/pulse hybrid-mode laser. The exposed cores created backscattering signals in the OTDR attenuation trace. It was demonstrated that the backscattering peaks were independently sensitive to temperature variation. Since the 1.5-mm-long exposed core showed a 5-m-wide backscattering peak, the OTDR with a spatial resolution of 40 mm allows for making a sensor node at every 5 m for independent multiplexing. The performance of the sensor node included an operating range of up to $120^{\circ}C$, a resolution of $0.59^{\circ}C$, and a temperature sensitivity of $-0.00967dB/^{\circ}C$. Temperature monitoring errors in the environment tests stood at $0.76^{\circ}C$ and $0.36^{\circ}C$ under the temperature variation of the unstrapped fiber region and the vibration of the sensor node. The small sensitivities to the environment and the economic feasibility of the highly multiplexed HPCF temperature monitoring sensor system will be important advantages for use as system-integrated temperature sensors.

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Prediction and Measurement of Propagation Path Loss in Underground Environments (지하공간에서의 전파 경로손실의 예측 및 측정)

  • 김영문;진용옥;강명구
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.736-742
    • /
    • 2003
  • This paper presents the propagation path loss in a tunnel which is a kinds of underground environments. To predict propagation path loss more accurately, we choose a straight tunnel with rectangular cross-section. The simulated receiver powers that are using a hybrid waveguide model and a Ray-Tracing method, are compared with the measured ones as a function of distance between TX and RX antennas in tunnel. The attenuation value of regression analysis for measured power in the tunnel is 0.0238dB/m which is similar to the one of the EH1.2 mode, 0.0246dB/m in hybrid waveguide model. By comparing simulation with measurement in tunnels, it has been shown that the measured values are approximate to the simulated results of ray-tracing model. In the analysis of wide-band channel characteristics of the tunnel, the more the distance between TX and RX antennas in tunnel increases, RMS delay spread increases and coherence bandwidth decreases.

Acoustic Nonlinearity of Surface Wave and Experimental Verification of Characteristics (표면파의 음향 비선형성과 실험적 특성 검증)

  • Lee, Jae-Ik;Kwon, Goo-Do;Lee, Tae-Hun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.344-350
    • /
    • 2009
  • The goal of this study is to introduce the theoretical background of acoustic nonlinearity in surface wave and to verify its characteristics by experiments. It has been known by theory that the nonlinear parameter of surface wave is proportional to the ratio of $2^{nd}$ harmonic amplitude and the power of primary component in the propagated surface wave, as like as in bulk waves. In this paper, in order to verify this characteristics we constructed a measurement system using contact angle beam transducers and measured the nonlinear parameter of surface wave in an Aluminum 6061 alloy block specimen while changing the distance of wave propagation and the input amplitude. We also considered the effect of frequency-dependent attenuation to the measurement of nonlinear parameter. Results showed good agreement with the theoretical expectation that the nonlinear parameter should be independent on the input amplitude and linearly dependent on the input amplitude and the $2^{nd}$ harmonic amplitude is linearly dependant on the propagation distance.

A Study on Blood Flow Measurement Method using Independent Component Analysis (독립성분분석을 이용한 혈류 속도 측정 방법에 관한 연구)

  • Cho, Seog-Bin;Lim, Dong-Seok;Baek, Kwang-Ryul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.2 s.314
    • /
    • pp.10-17
    • /
    • 2007
  • The echo signal on ultrasonic transducer is a mixed signal from tissues, blood vessel walls, blood cells and noise. In this mixed-signal, the signal reflected from tissues and blood vessel walls is called clutter. It is necessary to extract pure blood signal from this mixed-signal, when measuring blood flow velocity with medical ultrasonic system The quality of measured blood flow velocity is highly dependent on sufficient attenuation of the clutter signals. In this paper, we suggest a clutter rejection method using ICA For simulation, the echo signals are generated by Field n ultrasonic simulation program In this echo signals, independent signals are separated by using ICA Then the blood signal is obtained from the separated signals. Blood flow velocity is measured by 2D autocorrelation method. We compare ICA clutter rejection method with PCA-based eigen filter method using both measured blood flow velocity profiles by 2D autocorrelation. In simulation results, ICA clutter rejection method can be better applied measuring blood flow velocity in noisy echo signals.

Irradiance Distribution in East Sea by Using Measured Optical Properties for Squid Jigging Vessels

  • Bae, JaeHyun;Kim, SangWoo;Park, TaeYang;Cho, HyunWoo;An, YoungDuk;Kim, SangHyun;Ra, HyunWoon;Cho, YoungSil;Koh, JaeSeok;Jung, MeeSuk
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.547-556
    • /
    • 2016
  • A fishing lamp is the instrument for attracting distributed fish to a certain place, and is the lighting system mainly used in fishery. In the inshore fishing, most fishing lamps are used for squid and hairtail jigging fishing, and the light source of the fishing lamps mainly used is metal halide with 1.5 KW in electric power consumption. We will analyze the irradiance distribution according to depth because squid is attracted towards light. To analyze irradiance distribution by such fishing lamps, data for seawater Type-II among the seawater types defined in 1976 are applied to East Sea. However, the Type-II data have limitations in analyzing precise seawater transmission characteristics, due to insufficient information on deep seawater. This paper analyzed the irradiance distribution of fishing lamps using the measurement of transmission characteristics in the seawater in East Sea up to 100 m underwater instead of Type-II data, which is not sufficient for transmission. A compensation factor was drawn between the actual measurement data and Type-II data through seawater transmission characteristics simulation.

Positioning using ZigBee and Ultrasound

  • Park, Chan-Sik;Kim, Seung-Beom;Kang, Dong-Youn;Yun, Hee-Hak;Cha, En-Jong;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.217-222
    • /
    • 2006
  • To find a location, GPS has been wildly used. But, it is hard to use in indoor because of very weak signal level. To meet indoor requirements, there have been many studies applying wireless communication networks such as WLAN, UWB and ZigBee. Among these, ZigBee is widely adopted in many WSN applications because it has an advantage of low-power and low-cost. In ZigBee, the RSSI is used as range measurement for ad-hoc network. The RSSI are converted to ranges using the signal attenuation model and these ranges become inputs of positioning methods. The obtained position with RSSI has large error because of its poor accuracy. To overcome this problem, ultrasonic sensors are added in many researches. By measuring the arrival time difference of ZigBee and ultrasound as a range measurement, the precise position can be found. However, there are still many problems: scheduling of beacons to transmit signals in a correct order, addition and synchronization of beacons and low-rate positioning rate. At this paper, an efficient method to solve these problems is proposed. In the proposed method, a node transmits ZigBee and ultrasound signal simultaneously. And beacons find the range with the received signals and send it back to a node with ZigBee. The position is computed in a node with the received ranges. In addition, a new positioning algorithm to solve the risk of the divergence in the linearization method and the singularity problem in the Savarese method is presented. Both static and dynamic experimental results show 0.02m RMS errors with high output rate.

  • PDF

Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans (갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구)

  • Jung-Soo Kim;Geun-Woo Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.401-408
    • /
    • 2023
  • Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of images acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid uptake system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the protocol of thyroid scan test (99mTcO4 - , 370 MBq) in normal results, 99mTcO4 - was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 cm). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when using the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was statistically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thyroid disease.