• Title/Summary/Keyword: attached table

Search Result 83, Processing Time 0.031 seconds

Evaluation of Seismic Performance of Valve Chamber System by Shaking Table Tests (진동대 실험을 통한 밸브실 시스템의 내진성능 평가)

  • Young-Soo Jeong;Kyeong-Seok Lee;Jin-Seok Yu;Hyung-Chae Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • The structural safety of expansion joints for piping systems has been drawing attention owing to ruptures and leaks of water pipes caused by earthquakes and road subsidence at soft ground. In general, metal bellows are installed as expansion joints to prevent various damages in the piping system. In this study, the seismic performance of a valve chamber system was evaluated by performing earthquake shaking table tests. To validate the benefits to structural safety of metal bellows in connecting steel pipes to valve chambers, the seismic tests were conducted on expansion joints (bellows) and general pipping, and the results were compared for durability. Strain gauges were attached to measure the effects of the input motion. As a result of the shaking table test, it was confirmed that the strain of the valve chamber structure and inflow or outflow steel pipes were decreased in 1/100, 1/20 by applied to the expansion joints.

Application and Design of Scent Display Device for Head-Mounted Display (HMD용 발향장치 설계와 적용)

  • Baek Yu, Min Ho;Kim, Min Ku;Keum, Dong-Wi;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.52-57
    • /
    • 2019
  • Studies to augment emotion and immersion in multimedia content through olfactory stimulation are being increasingly conducted in the past two decades, and a variety of scent devices have been developed. Most of the scent devices are very large and heavy; consequently, they are installed on a table rather than being attached to the Head-mounted Display (HMD). Even if such devices are mounted on the HMD, it is not possible to control the scent density because of the size limitation, and it is not easy to be immersed in the experience because of the noise caused by the scent device. In order for an actual virtual reality or an augmented reality system to work efficiently with the scent device, three conditions - noiseless, a compact design, and concentration control- must be satisfied. In this study, we design a scent device that satisfies these three conditions. By using a miniature piezoelectric pump, a small size scent device is designed so that it can be easily attached to the lower end of the HMD, and hardly any noise is generated. Moreover, it is possible to control the concentration of the scent by controlling the piezoelectric pump using amplitude and frequency.

Vision Inspection and Correction for DDI Protective Film Attachment

  • Kang, Jin-Su;Kim, Sung-Soo;Lee, Yong-Hwan;Kim, Young-Hyung
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.153-166
    • /
    • 2020
  • DDI(Display Driver IC) are used to drive numerous pixels that make up display. For stable driving of DDI, it is necessary to attach a protective film to shield electromagnetic waves. When the protective film is attached, defects often occur if the film is inclined or the center point is not aligned. In order to minimize such defects, an algorithm for correcting the center point and the inclined angle using camera image information is required. This technology detects the corner coordinates of the protective film by image processing in order to correct the positional defects where the protective film is attached. Corner point coordinates are detected using an algorithm, and center point position finds and correction values are calculated using the detected coordinates. LUT (Lookup Table) is used to quickly find out whether the angle is inclined or not. These algorithms were described by Verilog HDL. The method using the existing software requires a memory to store the entire image after processing one image. Since the method proposed in this paper is a method of scanning by adding a line buffer in one scan, it is possible to scan even if only a part of the image is saved after processing one image. Compared to those written in software language, the execution time is shortened, the speed is very fast, and the error is relatively small.

A Study on the Acceleration Response Amplification Ratio of Buildings and Non-structural Components Considering Long-Period Ground Motions (장주기 지진동을 고려한 건축물 및 비구조요소의 가속도 응답 증폭비)

  • Oh, Sang Hoon;Kim, Ju Chan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 2023
  • Structures of high-rise buildings are less prone to earthquake damage. This is because the response acceleration of high-rise buildings appears to be small by generally occurring short-period ground motions. However, due to the increased construction volume of high-rise buildings and concerns about large earthquakes, long-period ground motions have begun to be recognized as a risk factor for high-rise buildings. Ground motion observed on each floor of the building is affected by the eigenmode of the building because the ground motion input to the building is amplified in the frequency range corresponding to the building's natural frequency. In addition, long-period components of ground motion are more easily transmitted to the floor or attached components of the building than short-period components. As such, high-rise buildings and non-structural components pose concerns about long-period ground motion. However, the criteria (ASCE 7-22) underestimate the acceleration response of buildings and non-structural components caused by long-period ground motion. Therefore, the characteristics of buildings' acceleration response amplification ratio and non-structural components were reviewed in this study through shake table tests considering long-period ground motions.

Beach-chair lateral traction position using a lateral decubitus distracter in shoulder arthroscopy

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.164-164
    • /
    • 2008
  • The beach-chair traction position is designed to allow the use of traction while allowing the surgeon to orient the shoulder in an upright position and convert to an open procedure, if necessary. The patient is placed in the beach-chair position under general anesthesia. A three-point shoulder holder (Arthrex, Naples, Florida) is attached to the rail of the operating table on the same side as the surgeon, whereas it is placed on the side opposite the surgeon in the lateral decubitus position. A shoulder traction and rotation sleeve (Arthrex) are affixed to the arm following the manufacturer's instructions. Positioning the thumb toward the closed side of the sleeve ensures a field for the anterior portion of the rotator cuff and prevents the tendency of the suspension apparatus to place the arm in internal rotation. The arm is maintained in 30 to 40 degree abduction and 30 to 40 degree flexion by controlling the length and height of the bar and the location of the universal clamp. The universal clamp allows multiple planes of adjustment to control abduction and forward movement of the arm. The sleeve is attached to the longitudinal traction cable using a sterile hook, and a lateral strap is secured around the proximal portion of the sleeve to the overhead traction cable to ensure a field for glenohumeral reconstruction. The use of a lateral strap permits ideal shoulder positioning for improved access to the anterior and inferior glenohumeral joint. The lateral strap can be released or removed to widen the subacromial space during subacromial decompression or rotator cuff repair. A 10-lb weight is attached to the longitudinal traction cable for an average-sized person.

  • PDF

The Study on Hydraulic Model Experiment of Discharge Channel and Spillway (여수토 방수로의 수리모형검시에 관한 연구)

  • 김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.8 no.2
    • /
    • pp.1124-1140
    • /
    • 1966
  • 'This hydraulic experiment have been practised Juk an Reservoir spillway and discharge 'channel which the province Kyong Buk was constructed and designed U. hook, for seizing all state of hydraulic. As result of the experimellt planning and making the model test, it has gained the necessary data at the amendment, projection of the most rational and economical result. 1. Project (1) Experiment project....1/30 of the discharge (2) project flood....0.01945 $m^3$/sec (rapidly) 2. Design Experiment It were sighted the water level for the nine point (L. & R. sides of No. O, L. & R. of No.1, L. side of NO.2, NO.3, No. 4 and NO.5), but it appeared each other that the lowest water level was 0.63 m at spillway (No.5) and the highest water level 0.735m less than planning water level O.75 m at No. 0. It was regarded as the phenomena appearing the difference from the calculation of the rational formular and coefficient of discharge. 3. Experiment examine E. ${\circled1}$ As a table (2) it had not a difference in comparision with design and was some lower value than design experiment's. E ..${\circled2}$) !twas same table (3) in a consequence of Experiment contracted Rocky cutting. E.${\circled3}$. ${\circled4}$ It was done amend.ment Experiment by elevating G.H. in only control point, but was not sure result as a table (2)(3)(4), and so it was changed largely in ${\circled5}$ Experiment. E. ${\circled5}$ Increasing water level was understanded to be proportion to $V^2$ in consideration of centrifugal force in the curve part and showed velocity contracting in curve the effect order's being regular in consequence of 1/6 sloped extending G.H. attached from 5 No. 0 to 1. 50 m, to S No. 0+5m. (S; discharge channel number).

  • PDF

The Geometric Layout Analysis of the Document Image Using Connected Components Method and Median Filter (연결요소 방법과 메디안 필터를 이용한 문서영상 기하학적 구조분석)

  • Jang, Dae-Geun;Hwang, Chan-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.8A
    • /
    • pp.805-813
    • /
    • 2002
  • Document image should be classified into detailed regions as text, picture, table and etc through the geometric layout analysis if paper documents can be converted automatically into electronic documents. However, complexity of the document layout and variety of the size and density of a picture are the reason to make it difficult to analyze the geometric layout of the document images. In this paper, we propose the method which have a better performance of the region segmentation and classifications, and the line extraction in the table region than the commercial softwares and previous methods. The proposed method can segment the document into detailed regions by using connected components method even if its layout is complex. This method also classifies texts and pictures by using separable median filter even. Though their size and density are diverse, In addition, this method extracts the lines from the table adapting one dimensional median filter to the each horizontal and vertical direction, even though lines are deformed or texts attached to them.

Shaking Table Experimental Study on 3-Dimensional Floor Isolation in Main Control Room of Nuclear Power Plant (원전 주제어실 3차원 층 지진격리시스템의 진동대 실험 연구)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo;Yoon, Hyun-Do
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.57-66
    • /
    • 2008
  • An experimental study was performed to evaluate seismic reduction performance and applicability of 3-dimensional floor isolation system to the main control room of nuclear power plant. A friction pendulum system(FPS) and air spring were designed and fabricated for 3-dimensional floor isolation system. Two kind of the partial experimental model of a main control room attached to the FPS and air spring were tested on the shaking table. The experimental model consisted of a control panel, a $2.5m{\times}2.5m$ access floor, four FPS and air springs. The artificial time histories based on the vertical and horizontal floor response spectrums(OBE, SSE) of the main control room were used as the earthquake input signals in the test. Compared to non-isolated system, the seismic response of experimental models using 3-dimensional floor isolation system were shown considerable seismic reduction performance.

Calibration of Inertial Measurement Units Using Pendulum Motion

  • Choi, Kee-Young;Jang, Se-Ah;Kim, Yong-Ho
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.3
    • /
    • pp.234-239
    • /
    • 2010
  • The utilization of micro-electro-mechanical system (MEMS) gyros and accelerometers in low-level inertial measurement unit (IMU) influences cost effectiveness in a positive way under the condition that device error characteristics are fully calibrated. The conventional calibration process utilizes a rate table; however, this paper proposes a new method for achieving reference calibration data from the natural motion of pendulum to which the IMU undergoing calibration is attached. This concept was validated with experimental data. The pendulum angle measurements correlate extremely well with the solutions acquired from the pendulum equation of motion. The calibration data were computed using the regression method. The whole process was validated by comparing the measurement from the 6 sensor components with the measurements reconstructed using the identified calibration data.

An Improved Mechanistic Model to Predict Critical Heat Flux in Subcooled and Low Quality Convective Boiling

  • Kwon, Young-Min;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.236-255
    • /
    • 1999
  • An improved mechanistic model was developed to predict a convective boiling critical heat flux (CHF) in the vertical round tubes with uniform heat fluxes. The CHF formula for subcooled and low quality boiling was derived from the local conservation equations of mass, energy and momentum, together with appropriate constitutive relations. The model is characterized by the momentum balance equation to determine the limiting transverse interchange of mass flux crossing the interface of wall bubbly layer and core by taking account of the convective shear effect due to the frictional drag on the wall-attached bubbles. Comparison between the present model predictions and experimental CHF data from several sources shows good agreement over a wide range of How conditions. The present model shows comparable prediction accuracy with the CHF look-up table of Groeneveld et al. Also the model correctly accounts for the effects of flow variables as well as geometry parameters.

  • PDF