• 제목/요약/키워드: atmospheric plasma

검색결과 597건 처리시간 0.03초

연속 대기압 플라즈마를 처리한 폴리에스테르 섬유의 표면 특성 (Surface-Properties of Poly(Ethylene Terephthalate) Fabric by In-line Atmospheric Plasma Treatments)

  • 권일준;박성민;구강;송병갑;김종원
    • 한국염색가공학회지
    • /
    • 제19권4호
    • /
    • pp.38-46
    • /
    • 2007
  • Surface properties of the plasma treated fabric were changed while maintaining its bulk properties. Surface of plasma treated fabric take charge of enhanced adhesion by surface etching, surface activity. The water repellency coating Poly(Ethylene Terephthalate) fabric was treated with atmospheric pressure plasma using various parameters such as Argon gas, treatment time, processing power. Morphological changes by atmospheric pressure plasma treatment were observed using field emmission scanning electron microscopy(FE-SEM) and the zeta-potential measurement, contact angle measurement equipment. At the atmospheric pressure plasma treatment time of 150 sec, the power of 800W, the best wettability and peel strength were obtained. And we confirmed the possibility of industrial application by using atmospheric plasma system.

Curing of meat batter by indirect treatment of atmospheric pressure cold plasma

  • Jo, Kyung;Lee, Juri;Lim, Yubong;Hwang, Jaejun;Jung, Samooel
    • 농업과학연구
    • /
    • 제45권1호
    • /
    • pp.94-104
    • /
    • 2018
  • Nitrite is an essential additive for cured meat product. Plasma is ionized gas and reactive nitrogen species in plasma can be infused into meat batter and subsequently generate nitrites by reaction with water molecules after plasma treatment. However, the increase of nitrite in meat batter is limited with direct treatment of atmospheric pressure cold plasma because of the increase of meat batter temperature. Therefore, this study investigated the influence of indirect treatment of atmospheric pressure cold plasma on the physicochemical properties of meat batter. Meat batter was indirectly treated with plasma at 1.5 kW for 60 min. The pH of meat batter decreased while the temperature increased with plasma treatment time. The total aerobic bacterial count of meat batter was not affected by plasma treatment. The nitrite content of meat batter was increased to 377.68 mg/kg after 60 min of plasma treatment. The residual nitrite content of cooked meat batter also increased with plasma treatment time. The CIE $a^*$-value of cooked meat batter increased. As plasma treatment time increased, lipid oxidation tended to increase and protein oxidation significantly increased. According to these results, the indirect treatment of atmospheric pressure cold plasma can be used as a new curing method for replacing synthetic nitrite salts.

The Study of DNA Damage Induced by Atmospheric Pressure Plasma Jet and Their Mechanisms

  • Park, Yeunsoo;Song, Mi-Young;Yoon, Jung-Sik
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.155.1-155.1
    • /
    • 2013
  • The goals of this study are to elucidate the plasma effects on DNA molecules to apply some plasma based applications and also to find out the mechanisms of plasma-induced DNA damage in biomolecule. Nonthermal atmospheric pressure plasma has much potential for medical, agricultural and food applications for the future. The atmospheric pressure plasma jet (APPJ) contains radicals, charged particles, low energy electrons, excited molecules and UV light. It has been started doing experiments using APPJ at the early 21th. And some recent results showed that APPJ has a possibility to apply to new fields like mentioned above. But it is kind of at the very early stages of plasma based application. It is definitely necessary much of theoretical and experimental studies to further understanding to use nonthermal atmospheric pressure plasma in biomedical, agriculture and food parts. Here we introduce a new experimental system to study plasma effects on biomolecules. And we will show some recent results of LEE-induced DNA damage using electron irradiation apparatus under ultra-high vacuum.

  • PDF

상압 플라즈마 매개변수들이 산업용 전자부품의 세척공정(cleansing)에 미치는 효과 (The Effect of Atmospheric Plasma Parameters on Cleansing the Electronic-Industrial Parts)

  • 리의재
    • 한국표면공학회지
    • /
    • 제42권5호
    • /
    • pp.208-215
    • /
    • 2009
  • We employed atmospheric plasma to reactively remove the lubricant sprayed onto such industrial electronic parts as LCD chassis during sheet-metal forming processes and investigated basically the effect of plasma parameters on cleansing the surfaces of zinc-electroplated steel plates (EGI). Specimen prepared with some controlled amount of lubricant sprayed on their surfaces beforehand were subjected to two different kinds of atmospheric plasma, one being generated by using air and the other generated by using nitrogen (99.9% purity). Locating the plasma beams at the height range between 3.5 and 13.5 mm from the surface of each specimen and radiating for 5 to 30 seconds resulted out that the cases with a position of 3.5 mm and a duration of 5 seconds or longer showed the surfaces completely cleansed without a trace of lubricant. Furthermore we found out that the plasma generated by using simple air depicted higher cleansing ability than the other one generated by using expensive nitrogen, interestingly useful very much for industrial purposes. On another aspect, we confirmed that the drilled or cut surfaces of Zn-plated steel substrate would not be oxidized even under the influence of plasma during its cleansing process. Therefore, we could probably conclude from this fore-survey that a dry process adopting atmospheric plasma for cleansing industrial parts might be determined to become successful in terms of commercialization, cautiously.

Analysis of Single Crystal Silicon Solar Cell Doped by Using Atmospheric Pressure Plasma

  • Cho, I-Hyun;Yun, Myoung-Soo;Son, Chan-Hee;Jo, Tae-Hoon;Kim, Dong-Hae;Seo, Il-Won;Roh, Jun-Hyoung;Lee, Jin-Young;Jeon, Bu-Il;Choi, Eun-Ha;Cho, Guang-Sup;Kwon, Gi-Chung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.357-357
    • /
    • 2012
  • The doping process of the solar cell has been used by furnace or laser. But these equipment are so expensive as well as those need high maintenance costs and production costs. The atmospheric pressure plasma doping process can enable to the cost reduction. Moreover the atmospheric pressure plasma can do the selective doping, this means is that the atmospheric pressure plasma regulates the junction depth and doping concentration. In this study, we analysis the atmospheric pressure plasma doping compared to the conventional furnace doping. the single crystal silicon wafer doped with dopant forms a P-N junction by using the atmospheric pressure plasma. We use a P type wafer and it is doped by controlling the plasma process time and concentration of dopant and plasma intensity. We measure the wafer's doping concentration and depth by using Secondary Ion Mass Spectrometry (SIMS), and we use the Hall measurement because of investigating the carrier concentration and sheet resistance. We also analysis the composed element of the surface structure by using X-ray photoelectron spectroscopy (XPS), and we confirm the structure of the doped section by using Scanning electron microscope (SEM), we also generally grasp the carrier life time through using microwave detected photoconductive decay (u-PCD). As the result of experiment, we confirm that the electrical character of the atmospheric pressure plasma doping is similar with the electrical character of the conventional furnace doping.

  • PDF

펄스변조의 듀티비 변경에 따른 DBD 대기압 플라즈마 특성 연구 (Study on the Atmospheric Plasma Characteristics of Dielectric Barrier Discharge due to a Variation of the Duty Ratio of Pulse Modulation)

  • 박종인;황상혁;조태훈;윤명수;곽형신;진기남;전부일;최은하;권기청
    • 한국재료학회지
    • /
    • 제25권11호
    • /
    • pp.616-621
    • /
    • 2015
  • Atmospheric pressure plasma is used in the biological and medical fields. Miniaturization and safety are important in the application of apply atmospheric plasma to bio devices. In this study, we made a small, pocket-sized inverter for the discharge of atmospheric plasma. We used pulse power to control the neutral gas temperature at which the, when plasma was discharged. We used direct current of 5 V of bias(voltage). The output voltage is about 1 to 2 kilo volts the frequency is about 80 kilo hertz. We analyzsed the characteristics of the atmospheric plasma using OES(Optical emission spectroscopy) and the Current-Voltage characteristic of pulse power. By calculating of the current voltage characteristics, we were able to determine that, when the duty ratio increased, the power that actually effects the plasma discharge also increased. To apply atmospheric plasma to human organisms, the temperature is the most important factor, we were able to control the temperature by modulating the pulse power duty ratio. This means we can use atmospheric plasma on the human body or in other areas of the medical field.

상압 플라즈마를 이용한 무기박막의 화학기상 증착법에 대한 연구동향 (Chemical Vapor Deposition of Inorganic Thin Films using Atmospheric Plasma : A Review of Research Trend)

  • 김경남;이승민;염근영
    • 한국표면공학회지
    • /
    • 제48권5호
    • /
    • pp.245-252
    • /
    • 2015
  • In recent years, the cleaning and activation technology of surfaces using atmospheric plasma as well as the deposition technology for coating using atmospheric plasma have been demonstrated conclusively and drawn increasing industrial attention. Especially, due to the simplicity, the technology using atmospheric plasma enhanced chemical vapor deposition has been widely studied from many researchers. The plasma source type commonly used as the stabilization of diffuse glow discharges for atmospheric pressure plasma enhanced chemical vapor deposition pressure is the dielectric barrier discharge. In this review paper, some kinds of modified dielectric barrier discharge type will be presented. And, the characteristics of silicon based compound such as SiOx and SiNx deposited using atmospheric plasma enhanced chemical vapor system will be discussed.

Non-Thermal Atmospheric-Pressure Plasma Possible Application in Wound Healing

  • Haertel, Beate;von Woedtke, Thomas;Weltmann, Klaus-Dieter;Lindequist, Ulrike
    • Biomolecules & Therapeutics
    • /
    • 제22권6호
    • /
    • pp.477-490
    • /
    • 2014
  • Non-thermal atmospheric-pressure plasma, also named cold plasma, is defined as a partly ionized gas. Therefore, it cannot be equated with plasma from blood; it is not biological in nature. Non-thermal atmospheric-pressure plasma is a new innovative approach in medicine not only for the treatment of wounds, but with a wide-range of other applications, as e.g. topical treatment of other skin diseases with microbial involvement or treatment of cancer diseases. This review emphasizes plasma effects on wound healing. Non-thermal atmospheric-pressure plasma can support wound healing by its antiseptic effects, by stimulation of proliferation and migration of wound relating skin cells, by activation or inhibition of integrin receptors on the cell surface or by its pro-angiogenic effect. We summarize the effects of plasma on eukaryotic cells, especially on keratinocytes in terms of viability, proliferation, DNA, adhesion molecules and angiogenesis together with the role of reactive oxygen species and other components of plasma. The outcome of first clinical trials regarding wound healing is pointed out.

A spectroscopic study of the effect of humidity on the atmospheric pressure helium plasma jets

  • Han, Duksun
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1375-1380
    • /
    • 2018
  • Atmospheric-pressure plasma has a great potential in many applications due to its simplicity rather than low pressure plasmas. In material processing, biomedical applications, and many other applications, the input power, gas flow rate, and the geometry of electrode have been mainly considered and studied as important external parameters of atmospheric-pressure plasma control. Besides, since the atmospheric-pressure plasmas are typically generated in an open air, the relative humidity is difficult to control and can change day by day. Therefore, the relative humidity cannot be ignored for plasmas. Thus, in this work, the atmospheric-pressure plasma jet was characterized by changing relative humidity, and it was found that the increase in electron density and OH radicals are due to Penning ionization between helium metastable and water vapors at higher humidity condition.

상온 대기압 플라즈마의 치의학적 응용 (Applications of Non-Thermal Atmospheric Pressure Plasma in Dentistry)

  • 엄수혁;권재성;이정환;이은정;김경남
    • 대한치과의사협회지
    • /
    • 제52권12호
    • /
    • pp.783-794
    • /
    • 2014
  • Since the introduction of non-thermal atmospheric pressure plasma in the field of the dentistry, numerous applications have been investigated. Especially with its advantages over existing vacuum plasma in terms of portability, low cost, and non-thermal damage, it can be directly applied in the oral cavity, giving number of potentials for dental application. First, possible application of non-thermal atmospheric pressure plasma in the field of dentistry is relation to dental caries and periodontal diseases. Teeth and alveolar bones are one of the strongest bony structures in our body, but it cannot be regenerated when they are damaged by dental caries or periodontal disease. Hence many studies to prevent such diseases have been carried out, though no perfect solution has been found yet. With recent studies of modifying surfaces through non-thermal atmospheric pressure application that can prevent attachment of bacteria, or studies on bactericidal effects of non-thermal atmospheric pressure plasma can be applied here to prevent oral pathogen and 'biofilm' attachment to the surface of teeth or directly eliminate the dental caries/periodontal disease causing germs. Secondly, non-thermal atmospheric pressure application will be useful on the surface of dental implant. It is well known that the success of dental implant surgery depends on the process known as 'osseointegration' that result from osteoblast attachment, proliferation and differentiation. As the application of non-thermal atmospheric pressure plasma on the surface of dental implant just before its introduction by the chair-side of dental surgery. Despite its long history, the generation of non-thermal atmospheric pressure plasma has been greatly increased with its application in dentistry.