• Title/Summary/Keyword: assessment of collection

Search Result 478, Processing Time 0.022 seconds

An Analysis on the Needs Assessment of School Library Facilities in Korea (학교도서관 시설에 대한 요구조사 분석)

  • Kim, Sung-Jun
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.50 no.3
    • /
    • pp.93-112
    • /
    • 2016
  • This study is an analysis on the needs assessment of school library facilities in Korea. After exploring KLA's Standards for Korean Libraries, IFLA's School Library Guidelines and AASL's Empowering Learners, the needs assessment tool of school library facilities was proposed in the previous study. The tool contains 10 major properties on school library facilities. This study gathered data from 507 students and 134 teacher librarians. The result of analysis is as follows: Students and teacher librarians evaluated the importance of library facilities more highly than the current level of facilities. Collection access, convenience and space are revealed more important properties to students and good environment, expandability, collection access are more important to teacher librarians among the properties.

Examining the Collection Management Process in Public Libraries (공공도서관 장서관리 현황 분석)

  • Lee, Jee-Yeon
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.43 no.3
    • /
    • pp.247-267
    • /
    • 2009
  • This study attempted to analyze the collection management process and its requirements for public libraries. The survey was designed to examine the detailed collection management guidelines and to grasp its requirements varying across different types of public libraries. The respondents to the survey were librarians who are responsible for managing collections in public libraries which achieved excellence in the 2008 nationwide library management assessment. The study results indicated that most public libraries do not have organized collection management guidelines covering the whole collection management area. In addition, small libraries such as those in hospitals, armies, and prisons have difficulties in managing collections since they do not have proper collection management guidelines.

The Development of Exposure Assessment Tools for Risk Assessment of Volatile Organic Compounds (VOCs의 위해성 평가를 위한 노출분석 방법 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Lee, Duck-Hee;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health issue in Korea and many important questions remain to be addressed with respect to assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in their analytic determination Valid Personal exposure assessment methods are needed to evaluate exposure frequency, duration and intensity, as well as their relationship to personal exposure characteristics. Biological monitoring is also important since it may contribute significantly in risk assessment by allowing the estimation of effective absorbed doses. This study was on ducted to establish the environmental measurement, personal dosimetry and biological monitoring methods for VOCs. These methods are needed to compare blood, urinary and exhalation breath VOC levels and to provide tools for risk assessment of VOC exposure. Passive monitors (badge type) and a active samplers (trap) for the VOCs collection were used for air sampling. Methods development included determining the minimum detectable amounts of VOCs in each media, as well as evaluating collection methods and developing analytical procedures. Method reliability was assessed by determining breakthrough volumes and comparing results between laboratories and with other methods. A total capacity of trap used in this study was 60ι. Although variable by compound, the average breakthrough was 20%. Also, there was no loss of compounds in trap even if keep for 45 day in -7$0^{\circ}C$. The recovery of active and passive methods was 69% ~ 126% and method detection limit was 0.24 $\mu\textrm{g}$/trap and 0.07 $\mu\textrm{g}$/badge. There was no statistical difference (P > 0.05) between active and passive methods.

Assessment of asbestos exposure level of workers handling waste containing asbestos (석면함유폐기물 취급근로자의 석면노출수준 평가)

  • Jeong, Jee Yeon;Kim, Eun Young
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.2
    • /
    • pp.135-143
    • /
    • 2018
  • Objectives: There have been many studies on exposure assessment of workers at companies using asbestos as a raw material and at sites of the removal of materials containing asbestos. However, no research has been carried out on the asbestos exposure of workers in industries involving asbestos-containing waste, such as workers at collection and transportation service companies, mid-treatment companies(solidification of asbestos-containing waste), and landfill sites. The objective of this study was to assess the asbestos exposure concentrations of workers in industries handling waste containing asbestos. Methods: For this study, we carried out field investigations at 15 companies: seven collection and transportation service companies, three mid-treatment companies, and five final treatment companies(landfill sites). We took both personal and area samples. Results: The range of asbestos exposure levels of workers handing asbestos-containing wastes at collection, mid-treatment, and landfill companies were 0.000 fibers/cc-0.009 fibers/cc, 0.000 fibers/cc-0.038 fibers/cc, and 0.000 fibers/cc-0.024 fibers/cc, respectively. Conclusions: The asbestos exposure levels of workers at mid-treatment companies were higher than those at collection and transportation companies and at final treatment companies. In the case of collection and transportation workers, the possibility of exposure to levels exceeding those found in the present study is not particularly high considering the characteristics of the work. However, in the case of intermediate or final disposal workers, it is considered that there is a possibility of exposure to levels above those found in this study.

Integrated Solid Waste Management for the Environmentally Sound and Sustainable Development (환경적으로 지속가능한 개발을 위한 폐기물의 통합적 관리 방안)

  • Hong, Sang-Pyo;Nam, Kie-Chang
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.87-98
    • /
    • 2000
  • The costs of solid waste management have continued to increase. Stricter environmental regulations have been applied to waste management units. Future integrated solid waste management should be balanced between source reduction, recycling, energy recovery, and land disposal. To achieve more balanced solid waste management programs, more local governments must adopt diversion and recycling goals and finance to meet those goals. The hierarchy of integrated solid waste management must be enforced in a manner that is flexible enough to allow local governments to implement waste management facilities that match the communities' ability to pay for them. In establishing a hierarchy of integrated solid waste management, local governements have difficulties in implementing source reduction and recycling because of a lack of local control and inability to pay for new facilities. Integrated solid waste management involves selecting compatible options for facilities to manage the collection, recovery of energy and materials(transformation), and disposal of solid wastes efficiently. Waste Collection, transformation, and disposal must support source reduction and recycling activities.

  • PDF

Study on Performance Evaluation of Marine Kitchen Ventilation Hood (선박용 주방 환기후드의 성능평가에 관한 연구)

  • Kim, Dong-Gyu;Chung, Yong-Hyun;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1373-1379
    • /
    • 2014
  • The purpose of this research is to evaluate the performance of the Ventilation hood and to make better oil collection for improvement. In order to complete the purpose, the research range has limited a kitchen cooking utensil used in preparing food in vessels. Assessment was carried out with reference(ASTM F1704-09) to the specification. Evaluation items of ventilation hood were flow visualization, oil collection rate and noise levels. When filter angle was 40 degrees, oil collection rate was increased by 9%.

Analysis of EIA for Electric power plant construction (전력산업의 환경영향평가 분석을 통한 제도개선)

  • Cha, Dong-Won;Kim, Yong-Hwa;Jeong, Kee-Wook;Kim, Chang-Hyeon
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.145-152
    • /
    • 1998
  • The first Environmental Impact Assessment(EIA) in Korea was carried out for Electric Power resource development. This study includes of the method and procedure of pre-Environmental investigation and EIA for Electric Power resource development. Through the analysis of these we make some conclusions for the improvemental and effective method of impact prediction, the environmentally sound and sustainable development of the earth(ESSD) and the collection of public opinions.

  • PDF

Reliability Analysis of Arcing Measurement System Between Pantograph and Contact Wire (팬터그래프-전차선간 아크 검측 장치의 신뢰성 분석)

  • Park, Young;Kwon, Sam-Young;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1216-1220
    • /
    • 2012
  • The current collection between pantograph and contact wire is a more critical component for need to train speed up in electric railway. The basic purpose of this paper is to establish a measure of determining arc by developing an arc detector assessment system. The system was designed under conditions of EN 50317 and simulations were conducted using the developed device. According to the results, it was possible to conduct certification tests following regulations of international standards. To check the validity of our approach for the intended application, we analysis contact loss of catenary system using developed arcing measurement system in Korea. The proposed arcing measurement system is expected to enhance precision of current collection quality performance assessment methods at high-speed lines and conventional lines.

Development of an Arc Detector Assessment System by Loss of Contact Between Pantograph and Contact Wire in Electric Railway (전기철도 팬터그래프-전차선간 이선아크 검측 평가 기술 개발)

  • Park, Young;Cho, Yong-Hyeon;Kwon, Sam-Young;Lee, Ki-Won;You, Won-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2171-2175
    • /
    • 2011
  • The objective of this paper is to discuss technologies on assessing reliability of arc detectors by composing a system that generates and simulates occurrence of arc caused by loss of contact between pantographs and contact wires in a laboratory condition. In order to establish the arc simulator, a device that generates light having the bandwidth of arcs that occur between carbon-metal. The simulator was designed under conditions of EN 50317 and simulations were conducted using the developed device. According to the results, it was possible to conduct certification tests following regulations of international standards and the precision of the simulator was satisfactory. The proposed arc detector assessment system is expected to enhance precision of current collection quality performance assessment methods at high-speed lines and conventional lines while being referred as fundamental technologies for development of detectors suiting international conditions.

Lifecycle and Requirements for Digital Collection Management of Thai Theses and Dissertations

  • Jareonruen, Yuttana;Tuamsuk, Kulthida
    • Journal of Information Science Theory and Practice
    • /
    • v.7 no.3
    • /
    • pp.52-64
    • /
    • 2019
  • This research was aimed at studying the situation, problems, and requirements for digital collection lifecycle management of Thai theses and dissertations. The mixed research method used was composed of: (1) Study of the problem and situation in which the qualitative method was applied. The research site covered 10 higher education institutions where the Thailand Digital Collection (TDC) project is operated. The informants were key administrative officers of the TDC project of each institution. In-depth and structured interviews were conducted on an individual basis to obtain the most accurate answers. (2) Study of requirements based on the quantitative research method to survey the requirements for the digital collection management system for Thai theses and dissertations from 84 purposively-selected TDC project officers and 527 end users selected by accidental sampling, totaling 611 samples. Research findings are as follow: (1) The study of the situation and problems of digital collection lifecycle management shows that Thai higher institutions systematically manage their digital collection. The management lifecycle is consistent with the Guidance documents for lifecycle management of ETDs, which included seven steps: program planning, creation, submission, and ingestion, access and retrieval of digital objects, archiving and preservation, evaluation and assessment, interoperation (creation of institutional collaboration), and development of link data. (2) The study of requirements for digital collection management of Thai theses and dissertations shows five system requirements: acquisition and gathering, digitization, metadata standards, management of rights, and storage and retrieval, all of which are at M (mandatory) and D (desirable) levels.