• 제목/요약/키워드: asbestos containing buildings

검색결과 14건 처리시간 0.027초

석면함유 공공 건축물의 위해성 평가 및 면적 분포 특성 (An Asbestos Risk Assessment and Areal Distribution of Asbestos Containing Materials in Public Buildings)

  • 송수진;장봉기;조봉현;김영지;허은협;이종대;손부순;이종화
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.267-276
    • /
    • 2016
  • Objectives: This study, aims to examine the distribution characteristics of asbestos-containing building materials; risk assessment and area of distribution of asbestos-containing building materials depending on year of construction; building materials; types of building materials; and usage in public buildings in order to create fundamental data for safe management of public buildings. Methods: The asbestos investigation was conducted by an asbestos research institution from March to May 2014, targeting 41 public buildings which were subject to asbestos investigation in South Chungcheong-do Province. With respect to 381 presumed asbestos-containing materials, an investigation was conducted into whether they contained asbestos, asbestos type, content, year of construction, and use in the building were examined, and a risk assessment was performed. Results: Asbestos-containing building materials were used in 35 buildings(85.4%). Among them, 31(88.6%) were public buildings. Asbestos was detected in 73% of 381 suspected asbestos-containing materials, which were mostly ceiling materials (85.2%). The older the buildings, the more they showed a tendency to have a significantly higher risk assessment score. The ratio of average area with asbestos-containing building materials to total floor area was 57.6%, 44.1%, and 17.8% for buildings built in the 1980s, 1990s, and 2000s, respectively. This showed a tendency to be significantly higher with the age of the building. Conclusions: From the results above, it can be concluded that with the age of the buildings, the risk assessment score and the ratio of average area with asbestos-containing building materials to total floor area became significantly higher. Given the concern about the exposure to asbestos of residents and civil petitioners, safety management of older public buildings and measures for dismantling and removal of asbestos-containing building materials should therefore be urgently established.

실내의 석면농도 실태 조사 및 저감에 관한 연구 (A study on the survey and reduction of indoor asbestos concentration)

  • 서병원;이주화;박지훈;강선홍
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.325-337
    • /
    • 2014
  • The research on the actual condition of indoor asbestos concentration in Korea has not been thoroughly accomplished up to now. In this research the ratio of asbestos-containing buildings and indoor asbestos concentration was studied. This investigation was conducted in 2012 and 2013 and buildings were categorized based on region, building type by use, existing space(ground or basement), and construction year, respectively. Also the indoor asbestos concentration change was monitored to evaluation the efficiencies of two types of asbestos-concentration abatement devices. As a result, the ratio of asbestos-containing buildings in Seoul was largely decreased. The ratio of asbestos-containing buildings was higher in hospitals and schools regionally and in ground buildings than in basement. The average indoor asbestos concentrations were 0.0011, 0.0008 piece/cc in 2012 and 2013 investigation, respectively. Those values were much lower than standards(0.01 piece/cc), therefore the threat of indoor asbestos concentration might be negligible. In asbestos-concentration abatement experiments, the circulation velocity of ventilator were changed 2-6.7 m/sec. With 6.7 m/sec of velocity of ventilator, the concentration of indoor asbestos was fluctuated and maximum value was 2.4 piece/cc. With 4.5 and 2 m/sec of velocities of ventilator, the maximum concentration of indoor asbestos was fluctuated and maximum value was 0.9 piece/cc. This indicated that the concentration of indoor asbestos was decreased partly due to the free drop of asbestos. From these results, the proper velocity of ventilator seems to be between 4.7 and 6.5m/sec under this circumstance and further research is required. These research results may be used to guideline of asbestos management policy.

건축물에 사용된 석면함유물질(ACMs)의 조사 및 위해성 평가 (Investigation and Risk Assessment of Asbestos-Containing Materials used in Buildings)

  • 김홍관;천영우;노영만;홍승한;김치년;이익모
    • 한국산업보건학회지
    • /
    • 제28권1호
    • /
    • pp.35-42
    • /
    • 2018
  • Objectives:본 연구의 목적은 석면함유물질의 사용 특성을 조사하고, "환경부고시 제2016-230호 석면건축물의 위해성 평가 방법"을 적용하여 위해성평가를 실시하였다. Methods:서울 및 경인지역에 위치한 건축물 100개소를 선정하였으며, 지역의 구분은 서울 29개, 인천 20개, 경기 51개이다. 건축연도는 1970년대 3개, 1980년대 11개, 1990년대 42개, 2000년대 44개로 구분하여 조사하였다. 고형시료의 분석은 고효율 필터가 부착된 후드 내에서 입체현미경을 이용하여 전처리 과정을 거쳐 편광현미경으로 분석하였으며, 분석결과가 함유율 1% 초과인 경우에 석면함유물질(Asbestos-Containing Materials, ACMs)을 석면으로 규정하였다. 석면건축자재의 위해성 평가 방법 및 기준은 "환경부고시 제2016-230호 석면건축물의 위해성 평가 방법"을 참고하여 석면함유물질에 노출된 위해성 등급은 세 가지 단계(높음, 중간, 낮음)로 평가하였다. Results: 건축물 100개소 중 30개소, 고형시료 416개 중 36개(8.6%)에서 석면함유물질이 있는 것으로 나타났다. 1990년대에 지어진 건축물 42개 중 18개에서 석면이 높은 비율로 검출되었으며, 2000년대에 지어진 건물 44개 중 7개에서 가장 낮은 비율로 검출되었다. "환경부고시 제2016-230호 석면건축물의 위해성 평가 방법"에 따라 평가를 실시한 결과, 2개 건축자재의 위해성평가 등급은 "중간"으로 나타났으며, 28개의 건축자재는 "낮음" 으로 나타났다. Conclusion: 석면은 정부에 의해 규제되고 있어 적극적으로 관리를 하여야 하고, 다양한 상황에서 얻은 데이터가 뒷받침하는 석면 노출 위해성 평가방법을 도입하여 시행이 필요할 것이다. 개인이 소유하고 있는 건물의 경우 건축주가 석면 노출의 위해성을 인지하고 있어야 할 것이다.

석면함유 건축물의 석면 노출 및 위해성 평가 (Asbestos Exposure and Health Risk Assessment in Asbestos-Containing Buildings)

  • 정재원;김광수;조순자;이상준
    • 한국환경과학회지
    • /
    • 제21권9호
    • /
    • pp.1069-1078
    • /
    • 2012
  • This study was performed to evaluate the asbestos exposure levels and to calculate excess lifetime cacer risks(ELCRs) in asbestos-containing buildings for maintenance and management. The range of airborne asbestos concentration of 33 buildings was 0.0018 ~ 0.0126 f/cc and one site exceeded indoor air-quality recommended limit 0.01 f/cc. And ELCRs based on US EPA IRIS(Integrated risk information system) model are 1.5E-06 ~ 3.9E-05 levels, and there was no site showed 1.0E-04 (one person per million) level or more, and 11 sites showed 1.0E-05 (one person per 100,000 people) level or more. To prevent the release of asbestos fibers, it needs operation and maintenance of asbestos-containing building materials, and there are some methods such as removal, repairment, enclosure and encapsulation. In conclusion, a risk-based air action level for asbestos in air is an appropriate metric for asbestos-containing building management.

서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구 (A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul)

  • 이진효;이수현;김정연;김지희;정숙녀;김진아;오석률;김익수;신진호;어수미;정권;이진숙
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

석면함유 건축물의 관찰조사를 통한 실내공기 중 섬유 농도 변화 요인 추정 (Estimation of Factors Influencing Airborne Fiber Concentrations through an Observation Survey of Asbestos-containing Materials in Buildings)

  • 이승철;김부욱;이광용;신용철
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.174-183
    • /
    • 2015
  • Objectives: The objective of this study is the estimation of factors influencing airborne fiber concentrations by means of an observation survey of asbestos-containing materials in buildings. Methods: Forty-five samples were collected from four commercial buildings by NIOSH Method 7400 and classified according to current condition, potential activity, construction year, and operations and maintenance(O&M). Results: Airborne fiber concentrations by current condition(classified as good, fair and poor) were significantly different(p<0.05). Concentrations by potential activity were significantly different among groups(p<0.05), and those from the low activity group were higher than those from the middle activity group. Based on construction year, airborne fiber concentrations from the decade of the 1990's were higher than those from the 1960's. When O&M status was considered, airborne fiber concentrations from 1960's buildings were lower than those buildings not operated and maintained(p<0.01), because dust generation was influenced by O&M status. It was found that airborne fiber concentrations were related to current condition and potential activity via regression analysis, but the coefficient of determination was low. Also, correlation analysis showed that the higher the potential activity, the more current condition is worsened, but the relationship was not significant(r=-0.455, p>0.05). Conclusions: Airborne fiber concentrations in asbestos-containing buildings had weak relationships with current condition and potential activity.

PCM과 TEM을 이용한 서울지역 일부 공공 건축물의 실내공기 중 석면농도 조사 (An Investigation on the Airborne Asbestos Concentrations using PCM and TEM in the Public Buildings in Seoul)

  • 정숙녀;남은정;황순용;오석률;신진호;엄석원;채영주
    • 한국산업보건학회지
    • /
    • 제21권3호
    • /
    • pp.139-145
    • /
    • 2011
  • Objectives: This investigation is purposed to evaluate the airborne asbestos concentrations in the public buildings having asbestos containing materials(ACMs) in Seoul. Methods: The Seoul Metropolitan Government carried out an asbestos survey to the city-owned public buildings to identify the level of risk exposure, classified into low, moderate and high risk. To evaluate the airborne concentration of asbestos, 11 sampling sites in ten buildings based on the survey were selected. The air samples from the eleven sites were analyzed by Phase Contrast Microscopy(PCM) and Transmission Electron Microscopy (TEM), and compared the analytical results from the both. Results: 1. The airborne fiber concentrations by PCM were less than the detection limit($7f/mm^2$) in 9(82%) out of 11 sampling sites. The highest concentration was 0.0043 f/cc, but it was below the guideline value for indoor air quality(0.01 f/cc), proposed by the Ministry of Environment, Korea. 2. In two sampling sites, having moderate risk level, the chrysotile was identified and showed it's concentrations of 0.0102 s/cc and 0.0058 s/cc, less than $5{\mu}m$ lengths. 3. The ACMs identified in the two sampling sites were a packing material(65% of chrysotile) in mechanical area and a thermal system insulation(5% of chrysotile) in a boiler room. Having more possibility of asbestos emission in the mechanical area, it would be required to set up and carry out the asbestos management plan. Conclusions: Based on the result of this study, the airborne asbestos concentrations in the public buildings with ACMs were generally lower than the guideline value for indoor air quality. There are widespread concerns about the possible health risk resulting from the presence of airborne asbestos fibers in the public buildings. Most of the previous studies about airborne asbestos analysis in Korea were performed based on PCM method that asbestos and non-asbestos fibers are counted together. In the public and commercial buildings, having ACMs, it is suggested that the asbestos be analyzed by TEM method to identify asbestos due to concerns about asbestos exposure to workers and unspecified people.

A Proposal of Hazard/Risk Assessment Criteria and an Asbestos Management Method for Asbestos-containing Building Materials

  • Park, Wha-Me;Kim, Yoon-Shin
    • 한국환경보건학회지
    • /
    • 제38권1호
    • /
    • pp.66-72
    • /
    • 2012
  • Objectives: The AHERA method by the US EPA, ASTM E2356-04, and HSG264 by the UK HSE, all of which are hazard/risk assessment methods for asbestos-containing building materials, were reviewed and compared based on 231 homogeneous areas. In addition, the current Act on Asbestos Safety Management (enforcement: April 29, 2012) was reviewed and analyzed. This trial provided fundamental data for improving the current asbestos hazard/risk assessment method. Methods: For the hazard/risk assessment of 77 asbestos-containing public buildings including schools, 231 homogeneous areas were selected, each of which was assessed using AHERA, ASTM E2356-04, and HSG264. Results: The matching rate of the hazard/risk assessment stood at 20.4 percent between AHERA and ASTM, at 71.4 percent between AHERA and HSG264 and at 17.8 percent between ASTM and HSG264. The AHERA method includes a seven-category rating scale. There were three categories, two of which have three subcategories. ASTM provides two decision-making charts consisting of ten rating scales for current condition estimation and for potential for disturbance estimation. In addition, the HSG264 method has a total of 20 scores with four items, and then provides four grades. This HSG264 method cannot clearly separate current condition and potential for disturbance. Conclusions: In the Korean Act on Asbestos Safety Management, the hazard/risk assessment method for asbestos-containing building materials should consider balance between current condition estimation and the potential for disturbance estimation.

서울시내 건축물 석면해체·제거 사업장 및 주변에서의 공기 중 석면농도 특성에 관한 연구 (A Study on Characteristics of Airborne Asbestos Concentrations at Demolition Sites and Surrounding Areas of Asbestos Containing Buildings in Seoul)

  • 이진효;이수현;김정연;김지희;정숙녀;김진아;김익수;어수미;정권;이진숙;구자용
    • 대한환경공학회지
    • /
    • 제36권6호
    • /
    • pp.434-441
    • /
    • 2014
  • 본 연구에서는 석면해체 제거작업에 따른 작업자 및 주변 환경에 미치는 영향 등을 파악하기 위해 서울시내 건축물 석면해체 제거 사업장을 대상으로 공기 중 석면농도를 조사하고, 측정결과가 "석면안전관리법"에서 명시된 사업장 주변의 석면배출허용기준에 적합한지를 살펴보았다. 서울시내 총 37개소 석면해체 제거 사업장에서 총 288개의 공기 중 시료를 분석하였으며, 전체 288개 시료 중 101개 시료에서(35%) 검출한계($7fiber/mm^2$) 이하로 나타났다. 이 때 전체 공기 중 석면농도 평균값은 $0.003{\pm}0.002f/cc$로(최대 0.013 f/cc) 대부분의 공기 중 석면농도는 "석면안전관리법"에서 명시된 사업장 주변의 석면배출허용기준 0.01 f/cc 이하로 나타나 서울시내 건축물 석면해체 제거 사업장에서의 석면 노출가능성은 우려할 수준이 아닌 것으로 판단된다. 채취지점별로 살펴보면, 부지경계선(148개), 위생설비입구(25개), 작업장주변(실내)(7개), 작업장주변(실외)(11개)에 대한 공기 중 석면농도 결과, 각각 53개(36%), 5개(20%), 1개(14%), 4개(36%) 시료에서 검출한계 이하로 나타났으며 평균농도는 각각 $0.002{\pm}0.002f/cc$(최대 0.008 f/cc), $0.004{\pm}0.002f/cc$(최대 0.009 f/cc), $0.004{\pm}0.002f/cc$(최대 0.007 f/cc), $0.004{\pm}0.002f/cc$로(최대 0.008 f/cc) 나타났다. 또한 음압기(13개), 폐기물보관지점(27개), 폐기물반출구(9개), 거주자주거지역(48개)에 대한 공기 중 석면농도 결과, 각각 3개(23%), 8개(30%), 2개(22%), 25개(52%) 시료에서 검출한계 이하로 나타났으며 평균농도는 각각 $0.004{\pm}0.002f/cc$(최대 0.009 f/cc), $0.005{\pm}0.004f/cc$(최대 0.013 f/cc), $0.005{\pm}0.003f/cc$(최대 0.009 f/cc), $0.003{\pm}0.002f/cc$0로(최대 0.009 f/cc) 나타났다.

석면 해체제거 보양작업에서 JSA 및 Checklist 적용 (Application of JSA and Checklist in Asbestos Sealing)

  • 조규선
    • 한국안전학회지
    • /
    • 제35권2호
    • /
    • pp.61-66
    • /
    • 2020
  • As asbestos-containing buildings are getting older, asbestos deconstruction works are increasing. As a result, accident risks such as falls, cuts, electric shocks, and suffocation are increasing. Existing studies are mostly about health management and institutional policy research and there is little research on work risk. So workplace risk assessments that are easily applicable in the field are required to be applied. Sealing is the first process of asbestos deconstruction and is the first step to ensure worker's safety. Job Safety Analysis(JSA) and Checklist were used to identify the risk factors and to calculate the level of the risk. By comparing the two risk assessment tools, it was figured out that the JSA is appropriate for the initial process and change of work procedure while Checklist is appropriate for repetitive work. Because the sealing process is sort and simple, it is unlikely to cause serious injury. But since the risk of falling and cuts are exist, safety education and supervision are necessary to maintain a safe working environment.