An Investigation on the Airborne Asbestos Concentrations using PCM and TEM in the Public Buildings in Seoul

PCM과 TEM을 이용한 서울지역 일부 공공 건축물의 실내공기 중 석면농도 조사

  • Chung, Sook-Nye (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Nam, Eun-Jung (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Hwang, Soon-Yong (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Oh, Seok-Ryul (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Shin, Jin-Ho (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Eom, Seok Won (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Chae, Young-Zoo (Seoul Metropolitan Government Research Institute of Public Health and Environment)
  • 정숙녀 (서울특별시 보건환경연구원) ;
  • 남은정 (서울특별시 보건환경연구원) ;
  • 황순용 (서울특별시 보건환경연구원) ;
  • 오석률 (서울특별시 보건환경연구원) ;
  • 신진호 (서울특별시 보건환경연구원) ;
  • 엄석원 (서울특별시 보건환경연구원) ;
  • 채영주 (서울특별시 보건환경연구원)
  • Received : 2011.04.07
  • Accepted : 2011.08.28
  • Published : 2011.09.30

Abstract

Objectives: This investigation is purposed to evaluate the airborne asbestos concentrations in the public buildings having asbestos containing materials(ACMs) in Seoul. Methods: The Seoul Metropolitan Government carried out an asbestos survey to the city-owned public buildings to identify the level of risk exposure, classified into low, moderate and high risk. To evaluate the airborne concentration of asbestos, 11 sampling sites in ten buildings based on the survey were selected. The air samples from the eleven sites were analyzed by Phase Contrast Microscopy(PCM) and Transmission Electron Microscopy (TEM), and compared the analytical results from the both. Results: 1. The airborne fiber concentrations by PCM were less than the detection limit($7f/mm^2$) in 9(82%) out of 11 sampling sites. The highest concentration was 0.0043 f/cc, but it was below the guideline value for indoor air quality(0.01 f/cc), proposed by the Ministry of Environment, Korea. 2. In two sampling sites, having moderate risk level, the chrysotile was identified and showed it's concentrations of 0.0102 s/cc and 0.0058 s/cc, less than $5{\mu}m$ lengths. 3. The ACMs identified in the two sampling sites were a packing material(65% of chrysotile) in mechanical area and a thermal system insulation(5% of chrysotile) in a boiler room. Having more possibility of asbestos emission in the mechanical area, it would be required to set up and carry out the asbestos management plan. Conclusions: Based on the result of this study, the airborne asbestos concentrations in the public buildings with ACMs were generally lower than the guideline value for indoor air quality. There are widespread concerns about the possible health risk resulting from the presence of airborne asbestos fibers in the public buildings. Most of the previous studies about airborne asbestos analysis in Korea were performed based on PCM method that asbestos and non-asbestos fibers are counted together. In the public and commercial buildings, having ACMs, it is suggested that the asbestos be analyzed by TEM method to identify asbestos due to concerns about asbestos exposure to workers and unspecified people.

Keywords

References

  1. 권지운. 편광현미경을 이용한 고형시료 중 석면분석. 한국산업안전보건공단 산업안전보건연구원; 2009;1-2
  2. 김현욱. 대형건물내 비고형 석면함유 건축자재에 의한 기중 석면오염 및 관리실태. 한국산업위생학회지 1995;5(2): 137-146
  3. 서울특별시. 시 소유 공공건축물 석면사용 실태조사 및 석면지도 작성보고서. 서울특별시 맑은환경본부 클린 도시담당관; 2010;1-82
  4. 서울특별시 석면관리정보시스템. 공공건축물석면정보. 시공공건축물 DB정보. URL:http://asbestos.seoul.go.kr/
  5. 최정근, 백도명, 백남원. 우리나라의 석면 생산과 사용 및 근로자 수와 노출농도의 변화. 한국산업위생학회지 1998;8(2):242-253
  6. Burdett GJ, Jaffrey SA. Airborne asbestos concentrations in buildings 1986;30(2):185-199 https://doi.org/10.1093/annhyg/30.2.185
  7. Chesson J, Hatfield J, Schultz B, Dutrow E, Blake J. Airborne asbestos in public buildings. Environmental Research 1990;51(1):100-107 https://doi.org/10.1016/S0013-9351(05)80186-0
  8. Crump KS, Farrar DB. Statistical analysis of data on airborne asbestos levels collected in an EPA survey of public buildings. Regulatory Toxicology and Pharmacology 1989;10(1):51-62 https://doi.org/10.1016/0273-2300(89)90012-3
  9. Eastern Research Group, Inc. Report on the Expert Panel on Health Effects of Asbestos and Synthetic Vitreous Fibers: The Influence of Fiber Length, Prepared for Agency for Toxic Substances and Disease Registry Division of Health Assessment and Consultation; 2003;5-7
  10. Ganor E, Fischbein A, Brenner S, Froom P. Extreme airborne asbestos concentrations in a public building. British Journal of Industrial Medicine 1992;49(7):- 486-488
  11. Lee RJ, Van Orden DR. Airborne asbestos in buildings. Regulatory Toxicology and Pharmacology 2008;50(2):218-225 https://doi.org/10.1016/j.yrtph.2007.10.005
  12. NIOSH. Asbestos and other fibers by PCM No. 7400. 4th ed. NIOSH; 1994;1-7
  13. U.S. Environmental Pollution Agency. Assessing Asbestos in Public Buildings EPA 560/5-88-002. U.S. Environmental Protection Agency; 1986
  14. U.S. Environmental Pollution Agency. Asbestos Hazard Emergency Response Act 40 CFR Part 763 Appendix A to Subpart E. U.S. Environmental Protection Agency; 1987;781-815