• Title/Summary/Keyword: artificial joint

Search Result 276, Processing Time 0.035 seconds

A General Analysis and Complexity Reduction for the Lattice Transversal Joint Adaptive Filter

  • Yoo, Jae-Ha
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.2035-2038
    • /
    • 2002
  • The necessity of the filter coefficients compensation for the LTJ adaptive filter was explained generally and easily by analyzing it with respect to the time-varying transform domain adaptive filter. And also the reduction method of computational complexity for filter coefficients compensation was proposed and its effectiveness was verified through experiments using artificial and real speech signals. The proposed adaptive filter reduces the computational complexity for filter coefficients compensation by 95%, and when the filter is applied to the acoustic echo canceller with 1000 taps, the total complexity is reduced by 82%

  • PDF

Application of New Measurement Method for Improvement of Rock Joint Roughness Underestimation (암석 절리면 거칠기 과소평가의 개선을 위한 새로운 측정방법의 적용)

  • Hong, Eun-Soo;Lee, Joo-Gong;Lee, Jong-Sub;Lee, In-Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2C
    • /
    • pp.133-142
    • /
    • 2006
  • Many methods have been tried to more correctly measure rock joint roughness. However, true roughness may be distorted and underestimated due to the sampling interval and measurement method. Thus, currently used measurement methods produce a dead zone and distort roughness profiles. The purpose of this study is to suggest new roughness measurement method by a camera-type 3D scanner as an alternative of currently used methods. First, the underestimation of artificial roughness is analyzed by using the current measurement method such as laser profilometry. Second, we replicate eight specimens from two rock joint surfaces, and digitize by a 3D scanner. Then, the roughness coefficient values obtained from eight numbers of 3D surface data and from three hundred twenty numbers of 2D profiles data are analyzed by using current and new measurement methods. The artificial simulation confirms that the sampling interval is one of main factors for the distortion of roughness and shows that inclination of waviness may not be considered any current methods. The experimental results show that the camera-type 3D scanner produces 10% larger roughness values than current methods. As the proposed new method is a fast, high precision and more accurate method for the roughness measurement, it should be a promising technique in this area.

The Convergent Influence of the Incidence of Delirium in Patients after Arthroplasty (인공관절치환 수술 후 발생하는 섬망에 따른 융복합적 영향)

  • Kim, Young-Hee;Kwon, Young-Chae
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.369-377
    • /
    • 2016
  • This study examined artificial joint replacement surgery for early intervention and prevention of the occurrence of delirium surgery. Data of study were analysed using the sample through the EMR (Electronic Medical Record) and after surgery to provide basic data. The subjects were elderly aged 60 years or more and the number of the sample was 821. Data were analysed by using SPSS 20.0 with t-test, $x^2$-test and multiple logistic regression analysis. The study results showed patients with artificial joint replacement surgery incidence of delirium was 13.5%, findings of these variables insisted that the main influencing factors of delirium were caused by age, fall history, physical activity, emotional status, body mass index (BMI) before surgery. The study suggested that the above findings are required for early intervention, early detection and prevention of delirium.

Changes in Knee Joint Loading on Infilled Turf with Different Soccer Cleat Designs (축구화 스터드 형태에 따른 무릎 모멘트의 변화)

  • Park, Sang-Kyoon;Lee, Joong-Sook;Park, Seung-Bum;Stefanyshyn, Darren
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.369-377
    • /
    • 2009
  • The purpose of this study was to determine the relationship between different soccer cleat designs and knee joint moments. Twelve physically active males (mean(SD): age: 26.4(6.2)yrs; height: 176.4(4.1)cm; mass: 74.0 (7.4)kg) were recruited Kinematic and force plate data were collected for all subjects during normal running and a $45^{\circ}$ cutting maneuver, called a v-cut. Both motions were performed at $4.0{\pm}0.2\;m/s$ on infilled artificial turf with three pairs of soccer cleats of different sole plate designs, and one pair of neutral running shoes. Inverse dynamics were used to calculate three dimensional knee joint moments, with repeated measures ANOVA and post hoc paired Student's t-test used to determine significance between shoe conditions. Significant differences were found in the extension moments of the knee for running trials, and for external rotation and adduction moments in the v-cutting trials. Knee moments were greater in v-cut than running, and the traditional soccer cleats (Copa Mondial and World Cup) tended to result in greater knee moments than the Nova runner or TRX soccer cleat. Cleat design was found to influence 3-dimensional knee moments in a v-cut maneuver. In the translational traction test, there were significant differences between all conditions. In the rotational traction test, friction with soccer shoes were greater than friction with running shoes. However, no differences were found between soccer shoes. Higher moments may lead to increased loads and stresses on knee joint structures, and thus, greater injury rates.

The Comparison of Sphere Fitting Methods for Estimating the Center of Rotation on a Human Joint (인체관절의 회전중심 추정을 위한 구적합법의 비교)

  • Kim, Jin-Uk
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.53-62
    • /
    • 2013
  • The methods of fitting a circle to measured data, geometric fit and algebraic fit, have been studied profoundly in various areas of science. However, they have not been applied exactly to a biomechanics discipline for locating the center of rotation of a human joint. The purpose of this study was to generalize the methods to fitting spheres to the points in 3-dimension, and to estimate the center of rotation of a hip joint by three of geometric fit methods(Levenberg-Marquardt, Landau, and Sp$\ddot{a}$th) and four of algebraic fit methods(Delogne-K${\aa}$sa, Pratt, Taubin, and Hyper). 1000 times of simulation experiments for flexion/extension and ad/abduction at an artificial hip joint with four levels of range of motion(10, 15, 30, and $60^{\circ}$) and three levels of angular velocity(30, 60, and $90^{\circ}$/s) were executed to analyze the responses of the estimated center of rotation. The results showed that the Sp$\ddot{a}$th estimate was very sensitive to the marker near the center of rotation. The bias of Delogne-K${\aa}$sa estimate existed in an even larger range of motion. The Levenberg-Marquardt algorithm of geometric fit and the Pratt of algebraic fit showed the best results. The combination of two methods, using the Pratt's estimate as initial values of the Levenberg-Marquardt algorithm, could be a candidate of more valid estimator.

Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol

  • Chena, Lee;Eun-Gyu, Ha;Yoon Joo, Choi;Kug Jin, Jeon;Sang-Sun, Han
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.393-398
    • /
    • 2022
  • Purpose: This study proposed a generative adversarial network (GAN) model for T2-weighted image (WI) synthesis from proton density (PD)-WI in a temporomandibular joint(TMJ) magnetic resonance imaging (MRI) protocol. Materials and Methods: From January to November 2019, MRI scans for TMJ were reviewed and 308 imaging sets were collected. For training, 277 pairs of PD- and T2-WI sagittal TMJ images were used. Transfer learning of the pix2pix GAN model was utilized to generate T2-WI from PD-WI. Model performance was evaluated with the structural similarity index map (SSIM) and peak signal-to-noise ratio (PSNR) indices for 31 predicted T2-WI (pT2). The disc position was clinically diagnosed as anterior disc displacement with or without reduction, and joint effusion as present or absent. The true T2-WI-based diagnosis was regarded as the gold standard, to which pT2-based diagnoses were compared using Cohen's ĸ coefficient. Results: The mean SSIM and PSNR values were 0.4781(±0.0522) and 21.30(±1.51) dB, respectively. The pT2 protocol showed almost perfect agreement(ĸ=0.81) with the gold standard for disc position. The number of discordant cases was higher for normal disc position (17%) than for anterior displacement with reduction (2%) or without reduction (10%). The effusion diagnosis also showed almost perfect agreement(ĸ=0.88), with higher concordance for the presence (85%) than for the absence (77%) of effusion. Conclusion: The application of pT2 images for a TMJ MRI protocol useful for diagnosis, although the image quality of pT2 was not fully satisfactory. Further research is expected to enhance pT2 quality.

Changes of C-Reactive Protein and Erythrocyte Sedimentation Rate Level from Infection and Non-Infection after the Artificial Joint Surgery (인공관절 수술 후 감염과 비 감염에 따른 C-반응성단백과 적혈구침강속도의 변화 추이)

  • Kim, Min-Ju;Kim, Hye-Jeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.321-326
    • /
    • 2016
  • This study aimed to analyze the changes of C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) measured in acute infection within four weeks post artificial joint surgery to predict potential infection in early stages, provide rapid treatment, and prevent the abuse of antibiotics. This study included 50 patients with acute infection and 50 patients without any symptoms of infection, among patients who received artificial joint replacement surgery on the lower limbs in a four-week period. CRP was the highest two-to-three days after surgery. with $5.77{\pm}3.69$ and $5.17{\pm}3.48$, respectively, in those with infection and without infection. Thereafter, the value rapidly reduced in those without infection. However, it increased again to $3.16{\pm}2.87$ in the group with infection according to the bimodal curve (p<0.001). ESR was the highest two-to-three days after surgery, with $58.8{\pm}24.63$ and $44.08{\pm}21.48$, respectively. Thereafter, the value slowly reduced in those without infection. However, it was increased again to $47.62{\pm}26.26$ in those with infection according to the bimodal curve p<0.001). As this study shows, if there is an increasing trend for CRP and ESR after artificial joint replacement surgery, it may be possible to question whether patients are acutely infected post surgery. In particular, this result is expected and regarded as a useful factor for diagnosing infection due to the high level of sensitivity and uniqueness for CRP.

Performance Improvement of Pneumatic Artificial Muscle Manipulators Using Magneto-Rheological Brake

  • Ahn, Kyoung-Kwan;Cong Thanh, TU Diep;Ahn, Young-Kong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.778-791
    • /
    • 2005
  • A novel pneumatic artificial muscle actuator (PAM actuator), which has achieved increased popularity to provide the advantages such as high strength and high power/weight ratio, low cost, compactness, ease of maintenance, cleanliness, readily available and cheap power source, inherent safety and mobility assistance to humans performing tasks, has been regarded during the recent decades as an interesting alternative to hydraulic and electric actuators. However, some limitations still exist, such as the air compressibility and the lack of damping ability of the actuator bring the dynamic delay of the pressure response and cause the oscillatory motion. Then it is not easy to realize the performance of transient response of pneumatic artificial muscle manipulator (PAM manipulator) due to the changes in the external inertia load with high speed. In order to realize satisfactory control performance, a variable damper-Magneto­Rheological Brake (MRB), is equipped to the joint of the manipulator. Superb mixture of conventional PID controller and a phase plane switching control method brings us a novel controller. This proposed controller is appropriate for a kind of plants with nonlinearity, uncertainties and disturbances. The experiments were carried out in practical PAM manipulator and the effectiveness of the proposed control algorithm was demonstrated through experiments, which had proved that the stability of the manipulator can be improved greatly in a high gain control by using MRB with phase plane switching control method and without regard for the changes of external inertia loads.