• 제목/요약/키워드: array sensing

검색결과 256건 처리시간 0.024초

불평형 간섭계를 이용한 광섬유 청음기 배열의 수중음향 감지특성 연구 (Investigation of Underwater Sound Detection Characteristics of Fiber Optic Hydrophone Array by using an Unbalanced Interferometer)

  • 이종길;남성현;윤형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.617-621
    • /
    • 1998
  • Optical sensing techniques have been associated with high sensitivity and precise measurements and attracted considerable attention in recent years. In this paper, two channels TDM(Time Division Multiplexing) fiber-optic hydrophone array for the underwater applications was fabricated and their acoustic characteristics were investigated by using the acoustic water tank. A fiber length of the order of 100m is wounded at the hollow cylinder type aluminum mandrel. An unbalanced interferometer (discrete Mach-Zehnder type) was used. Sound detection performance is tested in the underwater tank with 2kHz continuous sound source. Finally, it is shown that two channels TDM(Time Division Multiplexing) fiber-optic hydrophone array can detect 2kHz sound stably.

  • PDF

이동 물체의 3차원 계측을 위한 PSD 센서 배열 설계 (PSD sensor array design for the 3D measurement of moving objects)

  • 김종만;도용태
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.106-113
    • /
    • 2008
  • Perceiving a 3D moving target is important for automated machines including robots in a factory. Although stereovision or ultrasonic ranging is often employed for the purpose, the former requires high-cost systems, and the latter suffers from low-resolution. In this paper, we propose a PSD sensor array to acquire the 3D profile of an object conveyed by a belt. Rectangular parallelepiped target objects at random positions and orientations are assumed. Nine PSD sensors are configured in a $3{\times}3$ array above the belt, and fired in a sequence so that cross-talk can be avoided. Time gaps among sensor readings are compensated to get a result that is obtainable when sensors' measurements are made simultaneously along a sensing line. The system designed is tested with various objects in experiments.

HIGH RESOLUTION IMAGE ACQUISITION MODE USING PANCHROMATIC REDUNDANT CHANNEL

  • Chang, Young-Jun;Kong, Jong-Pil;Huh, Haeng-Pal;Kim, Young-Sun;Park, Jong-Uk
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.800-803
    • /
    • 2006
  • The Space-borne electro-optical camera system, like KOMPSAT has panchromatic redundant image channel as well as primary channel in order to increase reliability of satellite system. In most case redundant channel never been used during the whole mission period. Staggered array configuration using redundant image channel and new operation mode proposed which operates primary and redundant channel simultaneously. Without new hardware design, fast electronics and system complexity, we can get 1.414 times more fine GSD image of original system and aliasing effect which corrupt high frequency information of image can be minimized. To get the more efficiency from staggered array configuration, we introduce masked pixel CCD.

  • PDF

길이방향 지폐계수기 투입구의 최적 설계 (Design of a Feeding Mechanism for Longitudinal Banknote Counters)

  • 윤준일;김권희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.848-852
    • /
    • 2001
  • A new approach to the design of bank note counters is suggested. Modern bank note counters are equipped with several types of sensors for counting and detection of counterfeit bank notes. To achieve higher speed of counting while maintaining the sensing capability, longitudinal feeding scheme is proposed. Several merits of longitudinal feeding are discussed. Taguchi method is used for the optimization of the feeding mechanism.

  • PDF

광섬유 간섭계형 센서 어레이의 구성 및 특성 조사 (Characterization of a Fiber-optic Interferometric Sensor Array)

  • 안준태;김병윤
    • 한국광학회지
    • /
    • 제5권1호
    • /
    • pp.152-157
    • /
    • 1994
  • 감지부에 두 개의 간섭계형 센서가 있고 원격측정이 가능한 광섬유센서 어레이를 구성하였다. 각 센서의 신호를 분리 측정하기 위하여 짧은 광펄스를 광원으로 하는 시간분할방식의 신호처리를 도입하였다. 센서의 측정감도는 수 kHz 영역에서 $40{\mu}rad\sqrt{Hz}$였고, 센서간의 cross talk은 -50dB 이하였다.

  • PDF

Position Estimation of Sound Source Using Three Optical Mach-Zehnder Acoustic Sensor Array

  • Hwang, Jeong-hwan;Seon, Seokpyeong;Park, Chang-Soo
    • Current Optics and Photonics
    • /
    • 제1권6호
    • /
    • pp.573-578
    • /
    • 2017
  • Position estimation of a sound source based on time difference of arrival at an array of three acousto-optic sensors is introduced. Each sensor consists of a Mach-Zehnder interferometer including a sensing part in one arm that is a piece of fiber surrounded by membrane in order to enhance the acousto-optic effect. Estimation error of a recorded gunshot sound signal was evaluated with the theoretically calculated values for two different locations.

Signal subspace comparison between Physical & synthesized array data in echo imaging

  • Choi, Jeong-Hee
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.262-267
    • /
    • 1998
  • In Synthetic Aperture Radar(SAR) imaging, the echoed data are collected by moving radar's position with respect to the target area, and this operation actually gives effect of synthesizing aperture size, which in turn gives better cross range resolution of reconstructed target scene. Among several inversion scheme for SAR Imaging, we uses an inversion scheme which uses no approximation in wave propagation analysis, and try to verify whether the collected data with synthesized aperture actually gives the same support as that with physical aperture in the same size. To do this, we make a signal subspace comparison of two imaging models with physical and synthesized arrays, respectively. Theoretical comparison and numerical analysis using Gram-Schmidt procedures had been performed. The results showed that the synthesized array data fully span the physical array data with the same system geometry and strongly support the proposed inversion scheme valuable in high resolution radar imaging.

  • PDF

혈압 측정을 위한 외팔보형 접촉힘 센서 어레이 (A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement)

  • 이병렬;정진우;전국진
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

Infrared Focal Plane Array 용 MEMS 구조체 개발 (Development of a MEMS Structure for an Infrared Focal Plane Array)

  • 조성목;양우석;류호준;전상훈;유병곤;최창억
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1461-1465
    • /
    • 2007
  • A micromachined sensor part for an infrared focal plane array has been designed and fabricated. Amorphous silicon was adapted as a sensing material, and silicon nitride was used as a membrane material. To get a good efficiency of infrared absorption, the sensor was made as a ${\lambda}/4$ cavity structure. All the processes were done in $0.5\;{\mu}m$ iMEMS fab. in the Electronics and Telecommunication Research Institute (ETRI). The processed MEMS sensor structure had a small membrane deflection less than $0.3\;{\mu}m$. This excellent deflection property can be attributed to the rigorous balancing of the stresses of individual layers. The efficiency of infrared absorption was more than 75% in the wavelength range $8\;-\;14\;{\mu}m$.

Experimental Results of Sub-Y-Type Array for High Angular Resolution Interferometric Radiometer at 37 GHz

  • Kang, Gum-Sil;Kim, Sung-Hyun;Choi, Jun-Ho;Kim, Yong-Hoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.534-536
    • /
    • 2003
  • The Sub-Y-type array is proposed to decrease the number of antennas keeping same resolution or to use same number of antennas in order to have a narrow 3dB beamwidth. When the sub-Y-type array is des igned with 136 antennas for comparison with MIRAS, the reduction rate is theoretically 30 %. The proposed ideas are evaluated by experimental interferometric radiometer at 37 GHz.

  • PDF