• Title/Summary/Keyword: arrangement of the buildings

Search Result 198, Processing Time 0.029 seconds

A Study on the evaluation of the Residential Environment Efficiency by Arrangement of Multi-Family Residential Buildings - focused on the evaluation of daylight and view environment - (공동주택 주동 배치유형에 따른 주거환경성능 평가에 관한 연구 - 일조 및 조망환경성능 평가를 중심으로 -)

  • Choi, Doo Sung;Do, Jin Seok
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.57-64
    • /
    • 2009
  • To make a prediction for a change of residential environment caused by the building code in Seoul which includes loosening the distance between multi-residential buildings, proposals of the four main building arrangements by analyzing examples were selected and then, amount of daylight and view efficiency were analyzed and presented through computer simulation for the proposals. In the result of the analysis, there was a difference among the arrangements but, when the distance between buildings was applied 0.8H as the least, residential environment like daylight and view efficiency per unit significantly decreased in quality. Particularly, for the middle stories(6-15) and the high stories(16~24), when the distance between buildings decreased from the current measurement, 1.0H, to 0.8H, the analysis indicated that 28% of daylight and 7% of view efficiency were reduced. In the building arrangements, an order of the best residential environment was followed in this sequence; balanced arrangement of flat type as the best, combined arrangement between L-shape and tower types, balanced arrangement of tower type, combined arrangement between flat and Y-shape types, grid arrangement of flat type, and combined arrangement between Y-shape and tower types as the least.

Strategic width-wise arrangement of viscous dampers in steel buildings under strong earthquakes

  • Huang, Xiameng
    • Earthquakes and Structures
    • /
    • v.20 no.2
    • /
    • pp.225-238
    • /
    • 2021
  • Supplemental passive dampers are widely employed to improve the structural performance of buildings under seismic excitations. Nevertheless, the added damping could be counter-productive if the axial forces induced by the damper reaction forces are not routed properly in the columns. A few researchers engaged to optimize the width-wise damper arrangement to improve the delivered path of the axial column forces. However, most of these studies are limited under the design-based seismic level and few of them has evaluated the collapse performance of buildings under strong earthquakes. In this paper, the strategic width-wise placement method of viscous dampers is explored regarding the building performance under collapse state. Two realistic steel buildings with different storeys are modelled and compared to explore higher mode effects. Each building is designed with four different damper arrangement scenarios based on a classic damper distribution method. Both a far-fault and a near-fault seismic environment are considered for the buildings. Incremental Dynamic Analysis (IDA) is performed to evaluate the probability of collapse and the plastic mechanism of the retrofitted steel buildings.

Consequential Change of Wind Environment in Building Arrangements (건물배치에 따른 풍환경 변화)

  • Lee, Sun-Young;Kim, Sang-Jin
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • The purpose of this study is to investigate the change of wind environment for different building arrangement. In this study, we analyze outdoor wind environment on different building arrangement that take same floor area ratio using the CFD (Computational Fluid Dynamics) method. We do not consider the effect of temperature. Building arrangements of low density, different hight and a lot of green area will change the effect of wind environment. The eight different arrangements of buildings are studied in this paper. In these calculations, we know the different arrangement of buildings change outdoor wind environments. Especially, reducing the number of building and crossing the different height of buildings have a good kind of wind environment at the same floor ratio. We know that these arrangement of buildings to reduce the heat island phenomena on city plan.

A Comparative Study on the Horizontal Openness of High-rise Residential Buildings in terms of Building Arrangement Type - Focused on the Cases in Daegu - (상업지역 내 초고층 주거건축의 주동배치방식에 따른 수평적 개방성 비교연구 - 대구지역 사례 중심으로 -)

  • Kwon, Jong-Wook;Park, Sang-Min;Park, Byong-Han
    • Journal of the Korean housing association
    • /
    • v.23 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • Openness to outside is one of the most critical advantages for high-rise buildings. However, the effect of openness can be decreased if it is blocked by other high-rise buildings, especially built within the building complex of commercial district. The purpose of this study is to identify the horizontal openness of high-rise residential buildings by comparing 3 different cases of building arrangement type. A new method of evaluation has been introduced on the basis of distance to measure the openness including the matter of securing privacy. As a result of this study, comparative analysis was possible and relatively plentiful results of analysis could be drawn out. Through the process of analysis, this study set the evaluation indicators suitable to the analysis of openness of unit households. Thereby, the results of this study are expected to be used as useful basic data in planning high-rise mixed-use buildings.

Morphological Characteristics of Apartment Complex Sites in Busan (부산 아파트단지 배치형태의 변화 특성에 관한 연구)

  • Lee, Sangjin;Park, SoHyun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.10
    • /
    • pp.45-54
    • /
    • 2018
  • The purpose of the research is to track the morphological transformation of apartment complex sites in Busan, especially focusing on building arrangement on apartment complex sites. Though there have been numerous studies regarding apartment housing, only few studies have been performed about the building arrangement. The arrangement has been poorly treated and not well disclosed as compared with other apartment-based research such as form of residential towers, floor plan, etc. The building arrangement is one of the most critical decisions at the early design stage and is affected by numerous social aspects such as building/zoning code, market demand, cultural preference, etc. Thus, the transformation of the arrangement may provide the hint for the change of socio-cultural demands of apartment housing. The research has been done on the existing 269 apartment complexes which have been built through 2016 in Busan. There are three categories set for analysis: relationship between buildings, relation between road and buildings, and the building arrangement along site perimeter. The result shows that significant change has occurred since 2000s; the arrangement has become diverse from three types to seven types. The early model of parallel or lattice types have been dominant until 2000, but the skewed one replaced the parallel or lattice types in Period V and Period VI, which is from 2001 through 2016.

The Relationship between Rafter Configuration and Dory Arrangement of 7-Dories Buildings in Late Joseon Dynasty (조선 후기 7량 목조건물의 서까래 구성과 도리 배열 상관성 연구)

  • Jeon, Myeong-Su;Ryoo, Seong-Lyong
    • Journal of architectural history
    • /
    • v.29 no.6
    • /
    • pp.29-40
    • /
    • 2020
  • This research is conducted focusing on the 7-Dories type wooden buildings showing different rafter installation. This research found the reason why the rafter configuration look different each other and the relationship the between rafters and the Dory. Factors were compared to determine why the rafter configuration show the formal differentiation. The comparison factors are as follows: 1. The type of rafter installation is related to the longitudinal length of the building. 2. The type of rafter installation is related to the number of Kans on the side of the building and is proportionate. 3. The type of rafter configuration is related to the Dory arrangement and is proportionate. 4. The type of rafter configuration is related to the Dory's vertical arrangement. If the Dory arrangement is small, it is identified as two-stage rafter configuration. And if the Dory arrangement is large, it is identified as three-stage rafter configuration. Eventually, it was confirmed that the rafter configuration were affected by the Dory arrangement.

A Study on Planning Ecological School Buildings by Traditional Construction Techniques -Focused of the buildings of traditional education institutions- (전통 건축기법을 이용한 친환경학교건축 계획방향에 관한 연구 -전통 교육건축을 중심으로-)

  • Kim, Yeon-Hyouk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.7 no.1
    • /
    • pp.29-38
    • /
    • 2008
  • The purpose of this study was to discuss how traditional construction practices could be applied to school buildings. The spatial arrangement and constituents of Seoweon and Hyanggyo buildings were analyzed, and the spatial arrangement and ground plans of current schools were analyzed as well. As a result, it's found that how the characteristics of traditional architecture should be reflected in today's school design is one of critical matters that need an immediate attention. Based on the case study, there are some suggestions about the application of traditional construction techniques to school buildings: (1) The link between internal and external spaces should be stressed. The type of spatial configuration the could ensure nature accessibility is required. (2) The use of environment-friendly materials is recommended, and classrooms should be arranged in a way to let them function as multipurpose educational spaces. (3) It's not advisable to construct school buildings according to the sung-Confucianistic construction techniques of traditional educational institutions, but there should evidently be a change in tasteless school buildings, They should be built in small size and in consideration of harmony with nature and ecosystem, and boarding schools should be constructed in a more careful and discreet manner.

  • PDF

Reconsideration of the Construction Period of the Jeongnimsaji Temple Site (정림사지 창건시기 재고)

  • Tahk, Kyung-Baek
    • Journal of architectural history
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2016
  • It was believed that Jeongnimsa temple was built after the capital was moved from Gongju to Buyeo. It was confirmed that it was built A.D. $625{\pm}20$ by conducting a paleomagnetic analysis on the fireplace, which was recently found at the bottom of Jungmunji(middle gate). Consequently, it is assumed that the temple was built in the early 7th century unlike the previous point of view. Therefore, this study evaluated if the fireplace at the bottom of Jungmunji was found at the geological stratum representing the Jeongnimsa temple. Moreover, the study examined when the fireplace at the bottom of Jungmunji was constructed on the soil stratum. It is possible that the fireplace was built in the early 7th century as shown in the paleomagnetic analysis. However, when we compared the soil strata of the Jungmunji and the existing five-story stone pagoda, it showed that the ground was prepared differently and they were built over a fairly long period of time. Furthermore, I discovered that there was a wooden pagoda under the five-story stone pagoda by examining the soil strata map. Therefore, previous studies evaluated the arrangement of auxiliary buildings of Jeongnimsa temple and concluded that it was built in the early 7th century. It is hard to determine when the temple was built based on the arrangement of auxiliary buildings, because it takes a long time to build a temple and auxiliary buildings can be relocated during this long construction period. Rather, we have to admit that there are various arrangement patterns through minor changes in buildings from the one pagoda and one main building(Geumdang) arrangement.

Analysis of the Visual Quality of Riverfront Skyline Through the Feature of Height and Spatial Arrangement of Tall Building

  • Puspitasari, Ayu Wandira;Kwon, Jongwook
    • Architectural research
    • /
    • v.21 no.4
    • /
    • pp.91-98
    • /
    • 2019
  • In modern times, numerous cities are competing to create the unique skyline adjacent to the water. Tall buildings located across the river have a great contribution to the skyline of a riverfront city and can be a precious asset for the city. Moreover, in several cities, tall buildings and their impact on the urban skyline are a matter that should be considered and regulated in urban design. Therefore, as a prominent element in a larger visual setting of the city, tall buildings should improve the visual quality of the skyline rather than diminish that quality. This research attempts to provide an objective method to analyze the visual quality of the skyline made by a group of tall buildings through their feature of heights and spatial arrangement from riverfront views. The analysis is determined by the design variables of building heights variation, heights transition, density, and spacing of a group of tall buildings. A comparative case study of tall buildings in Yeouido and Lujiazui was conducted to prove the effectiveness of the analysis. The proposed method can be used in a simple way in the quantitative approach to quantify the visual quality of the skyline. In conclusion, Yeuido's skyline is not quite interesting from the riverfront view in terms of height variation and continuity of the skyline view because they are dispersed. Conversely, Lujiazui's skyline from the riverfront vantage points has a good quality in all aspects of the feature of height and spatial arrangements of tall buildings cluster. These factors can be used for the urban designer on how proposed tall buildings within the cluster should appropriately respond to adding image on the skyline.

Effect of earthquake induced-pounding on the response of four adjacent buildings in series

  • Elwardany, Hytham;Mosa, Beshoy;Khedr, M. Diaa Eldin;Seleemah, Ayman
    • Structural Engineering and Mechanics
    • /
    • v.83 no.2
    • /
    • pp.153-166
    • /
    • 2022
  • Structural pounding due to strong seismic excitations can result in severe damage or even collapse of colliding structures. Many researchers focused on studying the mutual pounding between two adjacent structures while very few researches were concerned with the pounding of a series of structures. This paper aims to study the pounding effect on a series of four buildings having different natural frequencies. The paper also investigates the effect of different arrangements of the four buildings on their pounding response. For this, a mathematical model was constructed using Matlab code where, pounding was modeled using a contact force-based approach. A Non-Linear viscoelastic (Hertzdamp) contact element was used and activated only during the approach period of collision. The mathematical model was validated by comparing its prediction versus experimental results on three adjacent buildings. Then the model was used to study the pounding between four adjacent structures arranged in different sequences according to their natural frequencies. The results revealed that increasing the gap distance generally led to decrease the peak responses of the towers. Such response is somehow different from that predicted earlier by the authors for the case of three adjacent buildings. Moreover, the arrangement of towers has a significant effect on their pounding response. Significant difference between the natural frequencies of adjacent structures increases the pounding forces especially when the more flexible buildings are located at the outer edge of the series. The study points out the need for further researches on buildings in series to gain a better understanding of such complex phenomena.