• Title/Summary/Keyword: area measuring

Search Result 1,952, Processing Time 0.028 seconds

Design and embodiment about pulse modeling of light investigation for disease treatment by skin color (피부색에 따른 병변치료를 위한 광조사펄스모델링에 대한 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.5
    • /
    • pp.563-572
    • /
    • 2006
  • Advantage that light transmission treatment way of most suitable through skin can investigate light directly in part ar there is difference in ability photoelectricity month by diverse complexion of horn character department which is branch or head of a family outside part of skin and treatment according to various patient can be inappropriate. By result that this research uses color information after search each color ingredient that ingredient of HIS and YIQ that use method, color information to use skin impedance way and color information through skin area ion and difference video to do fixed measuring by light investigation way by skin impedance corresponds to skin color in an experiment though is most universal result according to patient's skin model area detection each single person's skin model through videotex automatically create and because measuring, investigate skin color, energy, wave length, approximately, transmission time, model of most suitable that draw pulse delay and so on and want and special quality, and saved standard of disease treatment pulse modeling by skin impedance, and design and manufacture light investigation pulse modeling system of most suitable by skin subordinate, and constructed suitable treatment pulse database by skin color.

  • PDF

Position of the Fist Cervical Vertebra in Relation to Cervical Curvature (제 1경추골의 위치와 경추만곡도 간의 관계)

  • Moon-Il Her;Kyung-soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.197-206
    • /
    • 1996
  • This study ws performed to investigate the relationship between cervical curvature and the spatial position of the posterior part of the atlas imaged in the lateral cephalograph. Sixty six patients with temporomandibular disorders(TMD) and twenty dental students were selected for patients group and control group, respectively. The average age of patients group was 26.3 years, and 24.9 years in control group. Measured variables were cervical depth, upper space between the atlas and the base of the occiput, lower space between the atlas and the spinous process of the axis, rea of the posterior part of the atlas imaged in the lateral cephalograph, and the cervical curvature passing through the uppermost point in dorsal side of Dens of the Axis to the lowermost and rearmost point of the 5th cervical vertebra. The reliability of the method used for measuring cervical curvature with curved ruler was also tested. The results obtained were as follows : 1. Cervical depth of patients group was 122.9mm and significantly shorter than that of control group, in which cervical depth was 131.9mm, and cervical depth was significantly correlated with other variables in all subjects. 2. Upper space was greater in patients group, but total space including upper and lower space showed no difference between the two groups. The average value of total space was 26.5mm. 3. Area of the posterior part of the atlas was 168.2$\textrm{mm}^2$ in patients group, and 186.5$\textrm{mm}^2$ in control group with significant difference between the two groups. 4. Average range of radius of cervical curvature were 33-40cm and there was no difference between the two groups. 5. There was no significant correlation between the cervical curvature and the area of the posterior arch of the atlas. 6. The method using curved ruler for measuring cervical curvature could be accepted as a reliable method.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

The Calibration of $^{90}$ Sr Ophthalmic Applicator by Measuring Electron Current (전류 측정 방식에 의한 안과용 $^{90}$ Sr 선원의 교정)

  • 이병용;신동오;김현자;홍성언;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.149-154
    • /
    • 1991
  • We have designed and applied the calibrationmethod of $\^$90/Sr Ophthalmic Applicaton by measuring the electron currents. We considered the number of electrons which is emitted from the source, the area of the source, and the electron stopping power in the water, and those data were used for calculation. Film was used for evaluating the accurate source area. Average electron stopping power was obtained by analyzing ${\beta}$-ray energy spectrum. We compared between the result from our method and that from the TLD measurements. The calibration result from our method shows 63.3 ${\pm}$5.1 cGy/sec, while 50.7${\pm}$7.3 cGy/sec from TLD measurement. But the supplier's specification tells 46.89.4cGy/sec.

  • PDF

Magnetic Orientations of Bull Sperm Separated into Head and Flagellum Treated by DTT or Heparin

  • Suga, D.;Shinjo, A.;Kurnianto, E.;Nakada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.2
    • /
    • pp.167-175
    • /
    • 2000
  • This paper describes the magnetic orientation of bull sperm separated into the head and the flagellum treated by DTT or heparin in a 5,400G static field. Semen samples collected from four bulls (Japanese Black) were mixed to the same sperm density. One percentage triton X-100 was used to extract the plasma membrane. The intact and demembranated sperm suspensions were treated with 20, 200, 2,000 mM DTT, 100, 1,000 or 10,000 units heparin solutions at $4^{\circ}C$ for 6 days. The decondensation of the sperm nuclei treated by DTT or heparin was examined by measuring the head area at 1, 3 and 6 days. After measuring the area, each sample was exposed to a 5,400G static magnetic field generated by Nd-Fe-B permanent magnets for 24 hours at room temperature. Results showed that the sperms were separated into the head and the flagellum through the DTT treatment. Almost of the separated heads showed that their long axis oriented perpendicularly to the magnetic lines of force, and most of the long axis perpendicularly oriented heads showed that their flat plane oriented perpendicularly in a 5,400G magnetic field. Also, the demembranation of the head tended to increase those perpendicular orientations, while those perpendicular orientations of the head declined with the decondensation of the sperm nuclei. These findings suggest that strong magnetic anisotropy for the perpendicular orientation of the long axis and the flat plane of the head occurs in the sperm nuclei in a 5,400G magnetic field. The separated flagellum showed lower parallel orientation, and the separated and demembranated flagellum showed parallel orientation to the magnetic lines of force in this magnetic field. These findings suggest that weak magnetic anisotropy of the parallel orientation of the flagellum occurs in the inside components in a 5,400G field.

Analysis of a Trend of Instrument Usage to Assess Cognitive Function of Breast Cancer Patients Undergoing Chemotherapy (항암화학요법으로 인한 유방암 환자의 인지기능 측정도구 사용 실태 분석)

  • Kim, Gyung-Duck;Chung, Bok-Yae;Kim, Kyung-Hae;Byun, Hye-Sun;Choi, Eun-Hee
    • Asian Oncology Nursing
    • /
    • v.11 no.3
    • /
    • pp.179-185
    • /
    • 2011
  • Purpose: This study analyzed recent trends of instrument usage assessing cognitive function of breast cancer patients undergoing chemotherapy. Methods: The researcher collected 64 studies outside the country that were published between January 1996 and August 2010. Results: There was no study on the instrument assessing all domains of cognitive function in breast cancer patients undergoing chemotherapy. Most instruments assessing cognitive function of breast cancer patients have been used for patients with dementia, depression, and/or organic brain damage. Also the objective neuropsychological tests such as the grooved pegboard for the psychomotor area, RCFT copy in visuospatial skill area and the WAIS-III block design have low sensitivity for measuring cognitive function in breast cancer patients, thus they are not good for applying to breast cancer patients. Conclusion: There is a need to develop an instrument which has good sensitivity and specificity for measuring the cognitive function of the breast cancer patients who experienced cognitive impairment after chemotherapy treatment. In addition, the developed instrument needs to be accessible and feasible in any nursing clinical setting for the purpose of accurate assessment and evaluation of the cognitive function among breast cancer patients.

EXAMINATION OF CALCULATION METHOD FOR THE FLEXURAL RIGIDITY OF CROP STALKS

  • Hirai, Yasumaru;Inoue, Eiji;Hashiguchi, Koichi;Kim, Young-Keun;Inaba, Shigeki;Tashiro, Katsumi
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.287-294
    • /
    • 2000
  • Calculation of the flexural rigidity value (EI) is indispensable for prescription of deflection characteristics of crop stalks in harvesting□Conventionally□EI has been determined by either average EI of the whole stalk or average EI of each stems divided into node through the calculation method of cantilever with homogeneous section□However□deflection characteristics of crop stalks caused by mechanical operation such as combine harvester were not exactly presumed by these conventional EI through the experiment by authors. Further, actual EI of a stalk changes in company with a change of moisture contents as time passes during the experiment. Finally, efficient calculation method for determining EI is needed in order to improve these problems. In this study, mechanical model based on actual structure of the crop stalk with variety sectional area was proposed. This mechanical model is calculated by the theory of cantilever with continuous stages. Therefore, improvement of both calculating accuracy on EI and efficiency of measuring system was tried. At first, this calculation method was applied to piano wire of which EI was recognized in advance. As a result, EI calculated from this new method coincided approximately with piano wire's EI. Next, applying to crop stalks as same as piano wire, relationship between loads acting on crop stalks and deflection values calculated by EI using this new calculation method was exactly presumed in comparison with conventional method. Further, measuring time of deflection test was greatly reduced. Finally, new calculation method of EI will be available for estimating mechanical characteristics of so many kinds of crop stalks in harvesting operation. Further, in this study, new deflection test using image-processing apparatus by computer will be introduced.

  • PDF

A study on the saving of energy consumption load using electrical heat control system (전기적 열제어 시스템을 사용한 에너지 소비량 감소에 관한 연구)

  • Han, Kyu Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.1
    • /
    • pp.58-66
    • /
    • 2013
  • Most of steam power plant in Korea are heating the feed water system to prevent freezing water flowing in the pipe in winter time. The heating system is operated whenever the ambient temperature around the power plant area below 5 degree Centigrade. But this kind of heat supplying system cause a lot of energy consuming. If we think about the method that the temperature of the each pipe is controled by attaching the temperature measuring sensor like RTD sensor and heat is supplied only when the outer surface temperature of the pipe is under 5 degree Centigrade, then we can save a plenty of energy. In this study, the computer program package for simulation is used to compare the energy consumption load of both systems. Energy saving rate is calculated for the location of Youngweol area using the data of weather station in winter season, especially the January' severe weather data is analyzed for comparison. Various convection heat transfer coefficients for the ambient air and the flowing water inside the pipe was used for the accurate calculation. And also the various initial flowing water temperature was used for the system. Steady state analysis is done previously to approximate the result before the simulation. The result shows that the temperature control system using RTD sensor represents the high energy saving effect which is more than 90% of energy saving rate. Even in the severe January weather condition, the energy saving rate is almost 60%.

Development of Traffic Volume Measuring System Utilizing DSRC and Radar Detector (DSRC와 레이더 검지기를 활용한 교통량 측정 시스템 개발)

  • Park, Hyun-Hwa;Lee, Sung-Hoon;Bae, Hong-Min;Kim, Byung-Seo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.143-148
    • /
    • 2015
  • In order to design and plan a city, the importance of collecting traffic information increases. However, current method to collecting traffic information by using sensors layed on the roads is not appropriate for exceptional cases such as national highway or newly planned city area, where sensors are already not layed. To scope the cases, the traffic information is estimated from traffic information of surroundings area. This paper develops portable traffic volume measuring equipment utilizing two or radar detector, so that more useful traffic information can be obtained in any environments. Furthermore, the system allows users to be able to instantly analyze gathered data on the site. The system has been tested in the field and proved the excellences theough the field test.

New Carotid Artery Stenosis Measurement Method Using MRA Images (경동맥 MRA 영상을 이용한 새로운 내경 측정 방법)

  • 김도연;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.12
    • /
    • pp.1247-1254
    • /
    • 2003
  • Currently. the north american symptomatic carotid endarterectomy trial, european carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidate for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiography. rotational angiography, computed tomography angiography and magnetic resonance angiography. A new computerized carotid stenosis measuring system was developed using MR angiography axial image to overcome the drawbacks of conventional carotid stenosis measuring methods, to reduce the variability of inter-observer and intra-observer. The gray-level thresholding is one of the most popular and efficient method for image segmentation. We segmented the carotid artery and lumen from three-dimensional time-of-flight MRA axial image using gray-level thresholding technique. Using the measured intima-media thickness value of common carotid artery for each cases, we separated carotid artery wall from the segmented carotid artery region. After that, the regions of segmented carotid without artery wall were divided into region of blood flow and plaque. The calculation of carotid stenosis degree was performed as the following; carotid stenosis grading is(area measure of plaque/area measure of blood flow region and plaque) * 100%.