• Title/Summary/Keyword: arch effect

Search Result 365, Processing Time 0.026 seconds

Effects of Foot Orthotics on the Foot Arch Strain related to Plantar Fasciitis During Treadmill Level and Uphill Walking and Running (평지와 오르막경사의 트레드밀 걷기와 달리기 동안 발보장구가 발바닥근막염과 관련된 발아치 스트레인에 미치는 영향)

  • Kim, Seung-Jae;Stefanyshyn, Darren;Kim, Ro-Bin
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.155-176
    • /
    • 2005
  • There is some evidence that one of major factors to produce plantar fasciitis depends on the magnitude of the foot arch strain. The orthotics that can reduce the foot arch strain during locomotion may be effective to prevent or treat plantar fasciitis. Therefore, the purpose of this study was to investigate the effect of control condition and three types of foot orthotics on 3-dimensional foot arch strain that can produce plantar fasciitis during treadmill level and uphill walking and running. Sixteen male subjects are recruited and the arch length and height strain according to three types of foot orthotics with respect to control condition were measured by using two digital video cameras. The first hypothesis which the comfort of foot orthotics would be increased from arch pad, half length orthotics to full length orthotics was mostly accepted. It suggested that the types of the foot orthotics could be properly prescribed according foot regions that is pain or abnormal. The second hypothesis which the foot arch strain can be reduced by foot orthotics during level heel-toe walking and running and the third hypothesis which the foot arch strain can be reduced by foot orthotics during uphill heel-toe walking and running were rejected. The foot arch length and height strain during walking and running showed small and subject-specific characteristics and could not be optimal biomechanical variable to prove the overall comfort. The forth hypothesis which the foot arch strain cannot be reduced by foot orthotics during uphill toe walking and running was accepted. With the foot arch length and height strain during uphill toe walking and running the windlass mechanism suggested by Hicks can be explained successfully and excessive uphill toe walking and running can be one of cause of plantar fasciitis. The dynamic investigation on the foot arch such as walking and running should be carefully observed with integrated insights considering ligaments and foot bones as well as plantar fascia, extrinsic muscles and tendons, and intrinsic muscles and tendons.

Fragility analysis of concrete-filled steel tube arch bridge subjected to near-fault ground motion considering the wave passage effect

  • Liu, Zhen;Zhang, Zhe
    • Smart Structures and Systems
    • /
    • v.19 no.4
    • /
    • pp.415-429
    • /
    • 2017
  • This paper focuses on the impact of the wave passage effect on the long-span bridge. In order to make the wave passage effect more obvious, ground motion samples are selected from the near-fault ground motion of the 1999 Chi-Chi earthquake and an arch bridge with a 280m main span is selected as a bridge sample. The motion ground samples are divided into two groups according to the characteristics of near-fault. A sequence of fragility curves is developed. It is shown that the seismic damage is increased by the wave passage effect and the increase is more obvious in the near-fault ground motion.

Creep effects on dynamic behavior of concrete filled steel tube arch bridge

  • Ma, Y.S.;Wang, Y.F.;Mao, Z.K.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.3
    • /
    • pp.321-330
    • /
    • 2011
  • Long-term properties of concrete affect structures in many respects, not excepting dynamic behaviors. This paper investigates the influence of concrete creep on the dynamic behaviors of concrete filled steel tube (CFT) arch bridges, by means of combining the analytical method for the creep of axially compressed CFT members, which is based on Model B3 for concrete creep, with the finite element model of CFT arch bridges. By this approach, the changes of the stress and strain of each element in the bridge with time can be obtained and then transformed into damping and stiffness matrices in the dynamic equation involved in the finite element model at different times. A numerical example of a long-span half-through CFT arch bridge shows that creep influences the natural vibration characteristics and seismic responses of the bridge considerably, especially in the early age. In addition, parameter analysis demonstrates that concrete composition, compressive strength and steel ratio have an obvious effect on the seismic response of the CFT arch bridge.

A Study on the Effect of Carrying Vertical Loads Over Embankment Piles (성토지지말뚝의 연직하중 분담효과에 관한 연구)

  • 홍원표;이광우
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.285-294
    • /
    • 2002
  • Embankment Piles, which is subjected to damage due to lateral movement of soft ground, can be classified into pile slab, cap beam pile, and isolated cap pile according to the installation pattern of pile cap. In the cap beam pile and the isolated cap pile method, the soil arch is developed by the different stiffness between pile and soil, and most embankment loads are transferred into embankment piles through soil arch. In these two methods, the difference of soil arch is that the soil arch of the cap beam pile method develops like the arch from of tunnel between cap beams and the soil arch of the isolated cap pile method develops like dome between isolated caps. Therefore, theoretical analysis methods on soil arching effect of the cap beam pile and the isolated cap pile method were respectively proposed according to their own arch form considering the limiting equilibrium of stresses in a crown of soil arch. And a series of model tests were performed both to investigate the load transfer by soil arching in fills above embankment piles and to verify the reliability of the theoretical analysis.

Effect of Gastrocnemius Strength to be Applicated Low-Dye Taping in Flatfoot with Arch-Recovery Exercise (Low-Dye 테이핑 적용이 아치회복운동을 시행한 편평족의 장딴지근력에 미치는 효과)

  • Park, Jae-Gyu;Kim, Gwang-Rok;Kim, Gun-Woo;Kim, Min-Ji;No, Su-Bin;Sung, Nu-Ga;Kim, Jin-A
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.3
    • /
    • pp.634-643
    • /
    • 2016
  • Purpose. The purpose of this study was to progress the effect of gastrocnemius strength when groups are applicated on low-dye taping group and without taping group of flatfoot with arch-recovery exercise. Methods. Subjects were measured navicular drop test to confirm of 16 university student in J city, low-dye taping group and without taping group were applicated both with arch-recovery exercise, three times per a week for four weeks. The power track were measured four weeks, total 3 times. Comparative analysis of the control group and experimental group were investigated of gastrocnemius strength. Results. The results, we found that after of arch-recovery exercise were significantly increased than before of arch-recovery exercise in each foot. And application of low-dye taping(experimental group) in flatfoot with arch-recovery exercise were significantly increased than control group. Conclusions. In conclusion, the arch-recovery exercise application were effective to low-dye taping significantly increase the gastrocnemius strength of flatfoot.

An experimental study on the load transfer machanism of shallow 2-arch tunnel excavation sequence with vertical discontinuity planes in sandy ground (연직 불연속면이 존재하는 얕은 심도의 사질토 지반에서 2-arch 터널 단계별 굴착에 따른 하중전이에 관한 실험적연구)

  • Oh, Bum-Jin;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.215-231
    • /
    • 2011
  • In this study, the behavior of a shallow 2-arch tunnel during the excavation in the sandy ground containing vertical discontinuity plane was experimentally studied. Load transfer mechanism in the pillar caused by a 2-arch tunnel excavation was observed. The position of the vertical discontinuity plane was varied. Model tests were carried out in the normal construction sequence of 2-arch tunnel. Test results-showed that the load transfer caused by the 2-arch tunnel excavation was concentrated in the discontinuity plane, and was cut by the discontinuity plane, so no load transfer took place above the discontinuity plane. It was also shown that the effect of adjacent tunnel excavation on the pillar load and the ground deformation was greater when excavating the upper half-face of the main tunnel, more than when excavating the lower half-face.

Structural Characteristics of Steel-Concrete Composite Plate Girder with Arch-Type Web Stiffener (아치형 복부판 보강재가 설치된 플레이트거더 강합성교의 구조적 거동특성)

  • Woo, Sang-Pyuk;Yoo, Jong-Ho;Lee, Hong-Kyu;Won, Yong-Seok;Kim, Sun-Hee;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • In this paper, we present the result of analytical investigation pertaining to the structural behavior of steel-concrete composite plate girder with arch-type web stiffener. In the arch-type web stiffener located in the compression side of web, infill concrete is cast to strengthen the arch-type stiffener and also to exert resisting force against compression force. This type of composite steel-concrete plate girder bridge is built and is in service. To understand the behavior thoroughly, analytical parametric study was conducted by using the finite element method. As a result it was found that the effect of arch-type stiffener with infill concrete is considerable for the design of such type composite girder bridge.

Development of a Gable-roofed Prefabricated Pipe-house for Improvement of Snow Endurance (내설성 향상을 위한 지붕형 조립식 파이프하우스의 개발)

  • Yang, In-Kyoo;Nam, Sang-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.3
    • /
    • pp.71-78
    • /
    • 2009
  • Pipe section of bending part at the arch type pipe-house showed an ellipse with oblateness of 0.076 on the average. Flexural rigidity of bending part decreased by average 6.3% than that of an original round shape section. The deflection of arch type pipe-house measured by model experiments showed much bigger than the result of structural analysis. In case of arch type pipe-house, we supposed that the decrease of flexural rigidity for the bending part of pipes had an effect on deflection of roof under the working load. This effect should be considered in the structural analysis. Bending resistance of gable type pipe-house used a prefabricated connector which developed in this study showed about $1.5{\sim}1.8$ times stronger than that of the existing arch type or gable type processed bending. Therefore, we supposed that the gable-roofed prefabricated pipe-house is safer than arch type or bent gable type in case of heavy snowfall. According to house scales and section properties of steel pipe in use, safe snow depths and rafter intervals were presented for design of gable-roofed prefabricated pipe-house. Their standards were established in the range of the durable models recommended by RDA, and the comparative examinations were conducted by means of structural analysis. It was evaluated that the developed greenhouse model had a high applicability in the field.

Limit point instability of shallow arches under localized sinusoidal loading

  • Ayfer Tekin Atacan
    • Structural Engineering and Mechanics
    • /
    • v.85 no.5
    • /
    • pp.665-677
    • /
    • 2023
  • In the present study, the limit point buckling and postbuckling behaviors of sinusoidal, shallow arches with pinned supports subjected to localized sinusoidal loading, based on the Euler-Bernoulli beam theory, are numerically analyzed. There are some studies on the buckling of sinusoidal shallow arches under the effect of sinusoidal loading. However, in these studies, the sinusoidal loading acts along the horizontal projection of the entire shallow arch. No study has been found in the relevant literature pertaining to the stability of the shallow arches subjected to various lengths of sinusoidal loading. Therefore, the purpose of this paper is to contribute to the literature by examining the effect of the length of the localized sinusoidal loading and the initial rise of the shallow arch on the limit point buckling and postbuckling behaviors. Equilibrium paths corresponding to certain values of the length of the localized sinusoidal loading and various values of the initial rise parameter are presented. It has been observed that the length of the sinusoidal loading and the initial rise parameter affects the transition from no buckling to limit point instability remarkably. The deformed configurations of the sinusoidal shallow arch under localized loading regarding buckling and postbuckling states are illustrated, as well. The effects of the length of the localized sinusoidal loading on the internal forces of the shallow arch are investigated during various stages of the loading.

Effect of Transverse and Longitudinal Arch Support of Individual Discount rate on the Balance Ability of the Body (개인별 인솔의 족궁 지지가 신체 균형능력에 미치는 영향)

  • Kim, Seon-Chil;Bae, Jin-Woo;Jang, Ji-Pil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • The body to achieve an interaction that are connected to each other. Foot of which plays an important role in motor activity. Insole that has been recently used, have a dynamic functional elements. In particular, support of Arch plays a very important role in terms of a motor function of the human body as a whole. It is possible to predict the proper support Arch with insole, the overall structure of the body there can affect the balance. In this study, by applying the insole which supports the Longitudinal arch and Transverse arch, you are trying to assess the interaction of balance and the body's ability. To target the 20 there is no problem in the sense of balance, college student, and changes were observed by measuring the Center of Position area and distance through the Biorescue device worn before and after led by Arch support. As a result, I showed improved results significantly discount rate after wearing in the Center of Position area and distance to assess the balance ability. Therefore, the correction insole function is to support the Longitudinal arch and Transverse arch to an important role in the foot. It may be that it has a functional element for improving the balance of the function of preventing collapse of the arch during walking, to disperse the weight of the entire foot, us reduce fatigue in the end.

  • PDF