• Title/Summary/Keyword: appearance test

Search Result 1,094, Processing Time 0.027 seconds

Studies of the components in Sedum sarmentosum Bunge as a materials of vegetable health (야채 건강음료 재료로서의 돌나물에 관한 성분 연구)

  • 김희아;홍철희;정형석
    • Culinary science and hospitality research
    • /
    • v.8 no.1
    • /
    • pp.55-69
    • /
    • 2002
  • Sedum Sarmentosum Bunge has been used as medical material and food in Korea. To upgrade it's value as a materials of beverage, I research and analysed nutritive substance and taste. Inorganic components content was included in the order of Ca, mg, P, K, Na, in line, and there were little Fe, Cu, Zn. It appeared much Ascorbic acid contents in May sample for March sample, but it was included less than other Green Vegetables. Chlorophyll contents decreased about 37.8% and 37.6% to the first each contents after seven days resulting measuring May sample and March sample in room temperature. There was much difference in appearance. Sedum Sarmentosum Bunge included a little polyphenol contents. Polyphenol contents decreased a little in five days in May sample and March sample. I measured phenol compounds of garlic acid, vani11ic acid, caffeic acid, p-coumaric acid, ferulic acid, most of consisted in corrected forms. Fragrance components were confirmed 9 kinds in March sample, 11 kind in May sample the common components in May sample and March sample were 7-octen-4-o1.

  • PDF

Comparison of the Mid-term Evaluation of Distance Lectures for the First Semester of 2020 and the First Semester of 2021: Targeting D Colleges in the Daegu Area (2020년도 1학기와 2021년도 1학기 원격수업에 대한 중간 강의평가 비교: 대구지역 D 전문대학을 대상으로)

  • Park, Jeong-Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.675-681
    • /
    • 2021
  • Recently, the Ministry of Education stipulates in the distance class operation regulations that student lecture evaluations for distance learning subjects should be conducted at least twice per semester and the results should be disclosed to students. Therefore, the lecture evaluation of D college was compared with the first semester of 2020 and the first semester of 2021. As for the multiple-choice evaluation result of the distance learning mid-course evaluation, the overall average of the mid-course evaluation of the distance class in the first semester of 2020 increased from 4.1819 to 4.4000 in the mid-course evaluation in the first semester of 2021.In the case of the first semester of 2020, due to Corona 19, all non-face-to-face classes were held, but in the first semester of 2021, face-to-face classes increased. The overall satisfaction level rose from 4.18 points in the first semester of 2020 to 4.39 points in the first semester of 2021. The screen composition, sound and picture quality, playback time, face appearance, lecture material provision, and frequency of use of the top 3% and bottom 3% also increased. Despite the changes caused by the LMS replacement, which was a concern, student attendance, assignments, and test submission rates also increased compared to the previous year. The null hypothesis that 'the difference between the two scores is the same' is the null hypothesis because the probability of significance is 0.000 and less than 0.05 in the case of the best 3% of the test result of the test result of the mid-course evaluation of distance classes in the first semester of 2020 and the evaluation of the intermediate lectures in the first semester of 2021. As this was rejected, it can be seen that the best score for the 2021 school year has significantly increased compared to the first semester of 2020. Also, in the case of Worst 3% or less, the significance probability is 0.000, which is less than 0.05, so the null hypothesis that 'the difference between the two scores is the same' was rejected, indicating that the Worst score for the 2021 school year was significantly higher than that for the first semester of 2020.

The Spectrum of CT Findings of COVID-19 Pneumonia: Acute Alveolar Insult and Organizing Pneumonia as Different Phases of Lung Injury and Repair (COVID-19 폐렴의 다양한 CT 영상 소견: 급성 폐포 손상과 기질화 폐렴)

  • Yun Su Kim;Ung Rae Kang;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.359-370
    • /
    • 2021
  • Purpose To analyze the findings and serial changes in chest CT lesions in 123 symptomatic patients with coronavirus disease 2019 (COVID-19). Materials and Methods From February 19 to April 7, 2020, a total of 123 confirmed COVID-19 patients (male, 44; female, 79; mean age, 59.2 ± 18.6) were enrolled in this retrospective study. A total of 234 CT scans were reviewed for the following patterns: acute alveolar insult (AAI) patterns: ground-glass opacity (GGO), crazy-paving appearance, mixed pattern, and consolidation; organizing pneumonia (OP) patterns: perilobular patterns, band opacity, curvilinear opacity, reversed halo opacity, and small nodular consolidation; resolving patterns: pure GGO, remnant curvilinear, small nodular consolidation, and serial changes of lung abnormalities. We compared the proportions of AAI pattern, OP pattern, or resolving pattern with time progression and analyzed the association between the patterns and disease severity using Pearson chi-square and Fisher's exact test. Results Predominant CT patterns were AAI pattern (87%) in the early hospital period group (0-10 days, after the onset of symptoms), OP pattern (45.7%) in the later hospital period group (after 10 days), and resolving pattern in discharge and follow-up group (47.2% and 84.8%, respectively). The difference in the proportions of predominant CT patterns with time progression was statistically significant (p < 0.001, Pearson's chi-square test). No statistically significant association was observed between the patterns and disease severity (p = 0.055, Fisher's exact test). No fibrous changes in the lesions were observed on follow-up CT scans. Conclusion The serial CT scans of COVID-19 patients showed the spectrum of COVID pneumonia CT manifestations as different phases of lung injury and repair.

Corrosion Characteristics of Cell-Covered Ternary Ti-Nb-Ta Alloy for Biomaterials

  • Kim, W.G.;Yu, J.W.;Choe, H.C.;Ko, Y.M.;Park, G.H.
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Ti and Ti-alloys have good biocompatibility, appropriate mechanical properties and excellent corrosion resistance. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus (100 GPa) than cortical bone (20 GPa). Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. The electrochemical behavior of surface-modified and MC3T3-E1 cell-cultured Ti-30(Nb,Ta) alloys with low elastic modulus have been investigated using various electrochemical methods. Surfaces of test samples were treated as follows: $0.3{\mu}m$ polished; $25{\mu}m$, $50{\mu}m$ and $125{\mu}m$ sandblasted. Specimen surfaces were cultured with MC3T3-E1 cells for 2 days. Average surface roughness ($R_a$) and morphology of specimens were determined using a surface profilometer, OM, and FE-SEM. Corrosion behavior was investigated using a potentiostat(EG&G PARSTAT 2273), and electrochemical impedance spectroscopy was performed (10 mHz to 100 kHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The microstructures of the Ti-30(Ta,Nb) alloys had a needle-like appearance. The $R_a$ of polished Ti-30Ta and Ti-30Nb alloys was lower than that of the sandblasted Ti alloy. Cultured cells displayed round shapes. For polished alloy samples, cells were well-cultured on all surfaces compared to sandblasted alloy samples. In sandblasted and cell-cultured Ti-30(Nb,Ta) alloy, the pitting potential decreased and passive current density increased as $R_a$ increased. Anodic polarization curves of cell-cultured Ti alloys showed unstable behavior in the passive region compared to non-cell-cultured alloys. From impedance tests of sandblasted and cell-cultured alloys, the polarization resistance decreased as $R_a$ increased, whereas, $R_a$ for cell-cultured Ti alloys increased compared to non-cell-cultured Ti alloys.

A Study on One-Piece Dress Pattern According to the Somatotype Alteration of Women in their 20s (20대 여성의 체형변화에 따른 원피스 드레스 원형연구)

  • Park, Ju-Hee;Hong, Jung-Min;Yoon, Jin-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.7 no.4
    • /
    • pp.407-412
    • /
    • 2005
  • This study is to establish the pattern for one piece dress which fits well to the women somatotype with different drop value and is functional and has high body fitness. Selected 2 testers from classified 4 types who were close to the average value and took twice dressing test. After successive correction and revision, patterns of one piece dress for each somatotype were established. M type ; Bust line is established to B/4+1.7 cm. Waist line is W/4+1.5+2.5 cm(dart amount) for front pattern and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+0.8 cm for front and H/4+0.8 cm for back and the bust dart amount is 2.5 cm. A type ; Bust line is established to B/4+1.7 cm. Waist line is W/4+1.5+2.5 cm (dart amount) for front pattern and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+1.5 cm for front and H/4+1 cm for back and the bust dart amount is 2.2 cm. X type ; Bust line is established to B/4+1.5 cm for front pattern and B/4+2 cm for back. Waist line is W/4+2+2.5 cm (dart amount) for front and W/4+1+2+1.4 cm(for two darts amount) for back. Hip line is H/4+1 cm for front and H/4+1.3cm for back and the bust dart amount is 2.8 cm. H type; Bust line is established to B/4+1.5 cm for front pattern and B/4+2cm for back. Waist line is W/4+1.7+2.5 cm (dart amount) for front and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+2 cm for front and H/4+1.5 cm for back and the bust dart amount is 2.8 cm. In order to achieve the objective evaluation on a new pattern in this study, the sensory evaluation for both Imwonja pattern and a new pattern in this study was completed. As a result of sensory evaluation, a new pattern of this study could accomplished a good appearance in reflecting characteristics of each types and could achieved the functional superiority than comparison pattern.

A Study of the Foundation Garment Manufacturing for the Well-Balanced Somatotype - With middle-aged womenhood - (체형(體型) 균형화(均衡化)를 위한 파운데이션 가먼트 제작(製作)에 관한 연구(硏究) - 장년층(長年層) 여성(女性)을 중심으로 -)

  • Choi, Mee Sung;Kim, Ok Jin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.2
    • /
    • pp.247-264
    • /
    • 1993
  • This study deals with the manufacturing of the foundation garments for the well-balanced somatotype of the Korean middle-aged womenhood. In order to get hold of the different somatotypes, a survey of a total of 134 middle-aged women in Kwangju area, ranging in their age from 45 through 59 was made. The statistical methods used for the analysis of the basic data were the Pearson's correlation coefficient, Anova, Cluster analysis and Stepwise. Emphasis of the try-on test was placed on (1) the comparison of anthropometric data before and after trying on the foundation garments, (2) sensory evaluation, (3) a rating on fit and performance, (4) the comparison by means of photograph. The conclusions obtained are as follows : 1) The 134 women sampled and measured were classified into the five groups of somatotype : the 52 women (34%) belong to Cluster 1 ; the 22 women(14.5%) belong in Cluster 2 ; the 12 women(7.9%) belong in Cluster 3 ; the 15 women(9.9%) belong in Cluster 4 ; the 33 women(27.7%) belong to Cluster 5. 2) As for the characteristics of the foundation garment design, the V-shaped neckline and chest dart was used. The adjust point is right above the perineum point. The foundation garment length is as far as trochanteric point. The materials used are cotton/polyurethane, lace, 100%cotton. The materials used for corrections were the sponge pad for the chest, and non-woven fabric pad for the back, shoulder and the hip. 3) The comparison of the anthropometric data of the subject when dressed in foundation garments showed a significant difference in bust point height, in bust point length and in nipple-ta-nipple breadth, which proves the foundation garments to be effective in correcting such part as the chest, the hip and the abdomen. 4) As considered in terms of the sensory evaluation, the item except for the shoulder and the armhole coincided with each other in the mean value and in the composite reliability coefficient, which also proves the foundation garments to be effective. 5) Subjects were satisfactory on fit, performance, design, of the foundation garment, and their changed appearance. 6) In the case of the comparison through the photographs, the silhouettes of all the five women subjects were found effectively to be balanced.

  • PDF

ORIGINAL ARTICLE - The incidence and types of C-shaped canal of permanent mandibular second molar in Korean sub-population: Cone-Beam CT data analysis (한국인의 영구 하악 제2대구치의 C형 근관 빈도와 형태 : Cone-Beam CT 자료 분석)

  • Moon, Jung-Bon;Jang, Ju-Kyong;Son, Sung-Ae;Park, Bong-Soo;Lee, Hyo-Jin;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.50 no.4
    • /
    • pp.203-210
    • /
    • 2012
  • Objective: The aim of this study was to investigate the incidence of the C-shaped canal of permanent mandibular second molar (PMSM) in Korean sub-population using Cone-Beam CT (CBCT) data and analyze the types of C-shaped canal. Materials & Methods: The protocol for this study was approved by the Institutional Review Board at the Pusan National University Hospital (E-2011039). Among the CBCT images taken of patients who visited the St. Bennedict Dental Hospital (Busan, Korea) from May 2008 to April 2011 for implant surgery and surgical removal of impacted teeth, high-quality CBCTs from 705 patients (361 male and 342 female) were screened and 607 PMSMs of 383 patients were evaluated retrospectively. All PMSMs were anatomically analyzed in detail by using image viewer software (EasyDent; Vatech). PMSMs were evaluated in the axial plane to investigate the shape of root and canals. The C-shaped canals were classified into five types. The total incidence, gender ratio, bilateral and unilateral appearance. and the correlation between right-side and left-side occurrences of C-shaped PMSMs were computed and compared statistically using the chi-square test. Results: Among the 607 PMSMs of 383 CBCTs of 187 females and 196 males, 198 PMSMs(32.6%) had C-shaped root and 158 PMSMs(26.0%) had C-shaped canals. The shape of C-shaped root canals at the furcalion level did not have significant change at the level of mid root (P<0.0001). Female had more prevalence of C-shaped root canals than male (P<0.0001). The prevalence of bilateral occurrence of C-shaped root canals was higher than unilateral occurrence. Conclusions: The occurrence of C-shaped PMSMs among a Korean population was 32.6% and was higher than other countries and ethnicities. Understanding the prevalence of PMSMs with a C-shaped root and/or canal in a Korean population may be useful for successful endodontic treatments.

A Study on the Nurse's Image Perceived by Nursing College Students (간호대학생이 지각한 간호사 이미지에 관한 연구)

  • Park, Mi-Hwa;Yang, Jin-Ju
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.1
    • /
    • pp.107-121
    • /
    • 2002
  • The purpose of this study was to identify how nurse's image was perceived by nursing college students. The subjects included were 315 students experienced clinical practice during $20{\sim}22$ weeks and 134 students not with a total of 449 nursing students in Gwangju and Chonnam. The data were collected from November 21 to December 5, 2001 by the structured questionnaires. The research tool was measured by 30 items divided into four dimensions; traditional, professional, social and personal image of nurse. Cronbach $\alpha$ for the tool of nurse's image was 0.8960. The data were analysed by SPSS 8.0 for Windows program using frequency, percentage, mean, standard deviation, t-test, ANOVA and scheffe. The results of this study were as follows; 1. In the nurse's image related to general characteristics, there were significant differences for school graduation, applicative motivation, interpersonal relationship and image forming factor. 2. In the Image forming factors, nursing college students perceived the nurse's image by visiting hospital or admission(37.9%), watching TV(25.8) and others; nurses' appearance during clinical experience(16.3). 3. The mean score for nurse's image of clinical experience group (2.76$\pm$0.28) was lower than that of non-clinical experience group(2.89$\pm$0.31) in significance (t=4.319, p=0.000). 4. In the nurse's image according to clinical experience, there were significant differences for traditional, professional, social, personal image between two groups and the lower mean scores were found in the clinical experience group in all dimensions. The ranks of dimensions were professional image(3.08), traditional image(2.76), social image(2.65), the personal image(2.59) in clinical experience group, whereas professional image(3.21), traditional image(2.93), social image(2.75), personal image(2.71) for non-clinical experience group.5. The high score items of nurse's image were 'worthwhile work(3.48)', 'always working hard(3.30)', 'profession(3.17)', 'strong responsibility toward work(3.08)', 'have a high technical skill(3.05)' in clinical experience group and 'worthwhile work(3.69)', 'always working hard(3.28)', 'clean and decent(3.22)', 'profession(3.21)', 'have a bountiful professional knowledge(3.18)' in non-clinical experience group. 6. The highest mean score for nurse's image related to the image forming factors was 86.8 by novels or literature and the second highest was 84.3 by visiting hospital or admission. And others(mean=82.1)was the most negative nurse's image by clinical experience. In conclusion, nurse's image perceived by nursing college students will be the mirror of themselves. And clinical experience will be the important opportunity to form the professional image with white uniformed nurses in future. Therefore it is important for clinical nurses to play professional roles rightly so that nursing students could form positive nurse's image.

  • PDF

Effect of Pre-Harvest Sprouting on Seed Viability, Germination and Seedling Emergence Rate of Rice (벼 수발아가 종자 활력, 발아율 및 입모율에 미치는 영향)

  • Shon, Jiyoung;Kim, Junhwan;Jung, Hanyoung;Kim, Bo-Kyung;Choi, Kyung-Jin;Yang, Woonho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.59 no.4
    • /
    • pp.427-434
    • /
    • 2014
  • This study aimed to investigate the effects of pre-harvest sprouting (PHS)-damaged grains of rice on seed viability, germination percentage and seedling emergence rate. As comparing the seed lots of same cultivar 'Hopum' with different PHS percentages, seed lot with 8% PHS (high PHS percentage) showed 30% lower germination than that with 1% PHS (low PHS percentage). The difference of seedling emergence rate and seed viability percentages between the two seed lots was consistent with that of germination percentage. PHS-damaged brown rice was observed protruded embryo, discolored endosperm and fungi infected grains. PHS grains were classified into two groups, PHS-I showing endosperm discoloration in one third of a grain and PHS-II in more than half of a grain. The seed lot with high PHS percentage had much more PHS-II grains than that of low PHS percentage. PHS-II grains showed remarkably lower germination percentage than PHS-I grains and got severely moldy during germination test. In laboratory experiment, morphological changes and re-germination ability of seeds which dried after germination by soaking were tested. Sprouted seeds of 3mm shoot length showed half discolored endosperm and had a strong resemblance with PHS-II grains. Re-germination percentage of 3mm sprouted seeds sharply decreased than 2 mm sprouted seeds. Sprouted seeds which were treated for accelerated-aging (AA) for 24hr at $45^{\circ}C$ were significantly reduced in re-germination percentage compared to that of non-AA-treated sprouted seeds. These results indicate that PHS with over 3mm shoot length can severely damage not only grain appearance but also seed viability, germination percentage and seedling emergence rate. Therefore, we conclude that larger difference of germination percentage or seedling emergence rate between seed lots having smaller difference of PHS percentage might be caused by accelerated seed deterioration in PHS-damaged rice grains.

Effect of a Fluoride - Containing Orthodontic Primer for Preventing Enamel Demineralization around Bracket (불소를 함유한 교정용 접착제의 브라켓 주변 법랑질 탈회 예방 효과)

  • Jang, Hayoung;Kim, Jongbin;Kim, Jongsoo;Oh, Sohee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.412-418
    • /
    • 2017
  • During orthodontic treatment, formation of white spot lesions (WSLs) around brackets has long been recognized as a potential risk. This study performed to investigate effect of preventing enamel demineralization and remineralization by application of fluoride-containing orthodontic primer. Fifty extracted bovine incisors teeth were randomly allocated to 3 groups: (I) Non-preparation specimens, (II) Application of Light Bond$^{TM}$ as fluoride containing orthodontic primer, (III) Application of Transbond$^{TM}$ XT Primer as traditional orthodontic primer without fluoride. Each group is demineralized under artificial carious solution. The demineralization pattern was evaluated using a Q-ray view, Vickers hardness test and polarized light microscope. The remained primer was calculated as 35 - 50%. The highest surface microhardness was shown on Light Bond$^{TM}$ surface. There were statistically significant differences in Vickers microhardness number between adjacent areas of Light Bond$^{TM}$ and non-prepared area. There was almost no demineralization of the enamel surface under the Light Bond$^{TM}$. At the adjacent site of Light Bond$^{TM}$, the shallow caries pattern and remineralization appearance were also observed. These results suggest that the use of fluoride-containing primers may be useful for bracket attachment to reduce enamel demineralization during orthodontic treatment.