• Title/Summary/Keyword: apparent density

Search Result 504, Processing Time 0.026 seconds

Correlation Among Permeability, Apparent Density, And Porosity of Human Lumbar Vertebral Trabecular Bone (인체 요추해면골의 배류계수, 겉보기밀도, 공극비 사이의 상관관계에 관한 연구)

  • 홍정화;강신일
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.333-338
    • /
    • 1997
  • Abnormal intraosseous flow and pressure in trabecular bone could cause various pathological conditions such as osteonecrosis and osteoarthritis. Characteristics of intraosseous fluid flow and pressure generation in porous trabecular bone can be significantly affected by the permeability. Factors which determine the permeability could be the porosity and apparent density of trabecular bone. However, there is little data on the permeability and the relationship among the permeability. porosity, and apparent density of trabecular bone. In this study. the permeability. porosity, and apparent density of human lumbar vertebral trabecular bone were experimentally measured. Also, a power relationship among the permeability, porosity, and apparent density was investigated to understand effects of the porosity and apparent density variations on the permeability of trabecular bone based on Kozeny-Carman equation. A near linear relationship between intraosseous fluid flow and time indicated that the fluid phase flowed through the pores in trabecular bone is governed by the permeability. The permeability of trybecular bone was found to have a significant power relationship with the porosity and apparent density (r: 0.84 and $\textit{p}$< 0.0005). The power relationship could be useful to determine the permeability of trybecular bone after measuring the apparent density and porosity.

  • PDF

Preparation of Low Density Ceramic Supporter from Coal Fly Ash

  • Yeon Hwang;Lee, Hyo-Sook;Lee, Woo-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.605-609
    • /
    • 2001
  • Low density ceramic supporter was prepared by using fly ash as a starting material for the application to the biological aerated filter (BAF) system, and the effect of additives and sintering atmosphere on the apparent and bulk density of the carrier was examined. Borax, Na$_2$O and glass powders were added to produce liquid phase. The density of the supporter decreased as the amount of borax increased. The bulk density of 0.79 g/㎤ and the apparent density of 1.10 g/㎤ were obtained when the fly ash with 15% of borax was sintered at 116$0^{\circ}C$ for 15 minutes. The density also decreased as the plate glass powders past through 22${\mu}{\textrm}{m}$ size were mixed. When the fly ash with 12% of grass powder was sintered at 128$0^{\circ}C$ for 10 minutes, the bulk and apparent density were 0.90g/㎤ and 1.00 g/㎤, respectively. Apparent density of 1.6~1.8g/㎤ was obtained when the fly ash was sintered at 120$0^{\circ}C$ in a weak reducing atmosphere. By maintaining the reducing atmosphere and sintering at a high heating rate, the liquid phase was farmed from the reduced composition of fly ash. This resulted in the formation of closed pores that enabled the low apparent density.

  • PDF

Correlations Among Speed of Sound, Broadband Ultrasonic Attenuation, Broadband Ultrasonic Reflection, and Bone Density in Bovine Cancellous Bone

  • Lee, Kang-Il;Choi, Bok-Kyoungi;Yoon, Suk-Wang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.2E
    • /
    • pp.69-77
    • /
    • 2003
  • Correlations between acoustic properties and bone density have been investigated in bovine cancellous bone. Speed of sound (SOS), broadband ultrasonic attenuation (BUA), and broadband ultrasonic reflection (BUR) were measured in 10 defatted bovine cancellous bone specimens in vitro. SOS showed a significant correlation with the apparent density of the bone. A comparable correlation was observed between BUA and the apparent density. BUR was rather highly correlated with the apparent density. It was shown that BUR had a weak correlation with BUA and a significant correlation with SOS. This indicates that the parameter BUR can provide important information that may not be contained in BUA and SOS and, therefore, can be useful as an alternative diagnostic parameter of osteoporosis. As expected, a linear combination of all three ultrasonic parameters in a multiple regression model resulted in a significant improvement in predicting the apparent bone density.

The Syudy of Young's Modulus in Trabecular Bone with Bone Cement Injection (골강화제가 주입된 망상골의 영률에 관한 연구)

  • Moon, H.W.;Lee, M.K.;Park, J.Y.;Chae, S.W.;Lee, T.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1368-1372
    • /
    • 2003
  • PMMA which is used as the bone cement for vertebroplasty is able to be a supporter, as a fixing supporter role, for broken trabecular structure, caused by the compressed fracture of spine on aged osteoporosis. In this thesis, as experimenting apparent density of bone pieces, we have figured out support extent of Young's modulus as classifying the bone pieces injected PMMA and the others which are not. In case of low apparent density of PMMA in some bone, Young's modulus seems to be more supportable to bone. On the other hand, if apparent density of bones is normal, injection of PMMA is not very effective on improvement in Young's modulus of bone cement injection.

  • PDF

Feasibility of a Nonlinear Acoustic Method for the Assessment of Bone Status and Osteoporosis in Trabecular Bone

  • Lee, Kang Il
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1849-1854
    • /
    • 2018
  • The present study aims to investigate the feasibility of using a simple nonlinear acoustic method for the assessment of bone status and osteoporosis in trabecular bone. Correlations of linear and nonlinear ultrasound parameters with the apparent bone density were obtained in 32 bovine femoral trabecular bone samples. Highly significant positive correlations were observed between the apparent bone density and the two linear ultrasound parameters, the speed of sound (SOS) and the normalized broadband ultrasound attenuation (nBUA), with Spearman's correlation coefficients of r = 0.85 and 0.77. In contrast, the apparent bone density was found to be negatively correlated with the nonlinear ultrasound parameter introduced in the present study, the logarithmic difference between the power spectrum levels of the fundamental frequency and the second harmonic (PSL1-PSL2), with the highest correlation coefficient of r = -0.92. These results suggest that the PSL1-PSL2, in addition to the SOS and the nBUA, may be useful for the assessment of bone status and osteoporosis.

Effects of a compaction method for powder compacts on the critical current density of MgB2 bulk superconductors

  • Kang, M.O.;Joo, J.;Jun, B.H.;Choo, K.N.;Kim, C.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.2
    • /
    • pp.40-44
    • /
    • 2019
  • In this study, the effects of the compaction method for (Mg+2B) powders on the apparent density and superconducting properties of $MgB_2$ bulk superconductor were investigated. The raw powders used in this study were nano-sized boron (B) and spherical magnesium (Mg). A batch of a powder mixture of (Mg+2B) was put in a steel mold and uniaxially pressed at 1 ton or 3 tons into pellets. Another batch of the powder mixture was uniaxially pressed at 1 ton and then pressed isostatically at $1800kg/cm^2$ in the water chamber. All pellets were heat-treated at $650^{\circ}C$ for 1 h in flowing argon gas for the formation of $MgB_2$. The apparent density of powder compacts pressed at 3 ton was higher than that at 1 ton. The cold isostatic pressing (CIP) in a water chamber allowed further increase of the apparent density of powder compacts, which influenced the pellet density of the final products ($MgB_2$). The compaction methods (uniaxial pressing and CIP) did not affect the formation of $MgB_2$ and superconducting critical temperature ($T_c$) of $MgB_2$, but affected the critical current density ($J_c$) of $MgB_2$ significantly. The sample with the high apparent density showed high $J_c$ at 5 K and 20 K at applied magnetic fields (0-5 T).

Effects of Dietary Energy Concentration and Lysine on the Digestible Energy Ratio for Apparent Amino Acid Digestibility in Finishing Barrows

  • Cho, S.B.;Lee, H.J.;Chung, I.B.;Long, H.F.;Lim, J.S.;Kim, Y.Y.;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.2
    • /
    • pp.232-236
    • /
    • 2008
  • This experiment was performed to investigate the effects of two energy levels and four lysine:digestible energy (DE) ratios on the apparent digestibility of nutrients in finishing pigs. The experiment was conducted using a $2{\times}4$ randomized complete block (RCB) design with three replicates. Twenty-four cross-bred finishing barrows ((Landrace${\times}$Yorkshire)${\times}$Duroc) with an average body weight of $64.2{\pm}0.69kg$ were assigned to one of eight treatments. Each barrow was placed in an individual metabolism crate and dietary treatment and water was provided ad libitum. Diets were designed to contain lysine:ME ratios of 1.5, 1.8, 2.1 and 2.4 g/Mcal at 3.35 and 3.6 Mcal/kg of diet in a $4{\times}2$ factorial arrangement. Dry matter (DM), ash, Ca and P digestibility were not affected by energy density or lysine:DE ratios. Crude fat digestibility increased as the energy density increased from 3.35 to 3.6 Mcal of DE/kg. Increasing the lysine:DE ratio also increased crude protein digestibility. There were no interactions between energy density and lysine:DE ratio in terms of nutrient digestibility. Nitrogen excretion via feces was not affected by energy density and lysine:DE ratio, while nitrogen excretion via urine was significantly affected by energy density and lysine:DE ratio. The apparent digestibility of all amino acids except for isoluecine, arginine and aspartic acid as well as average values of essential amino (EAA), non-essential amino acids (NEAA) and total amino acid digestibility (p>0.05) were not affected by energy density. The apparent digestibility of all amino acids except for leucine, proline, alanine and tyrosine, NEAA and total amino acid digestibility were significantly affected by lysine: DE ratio (p<0.05). Interactive effects of energy and lysine:DE ratio also significantly affected amino acid digestibility except for isoleucine, alanine, cystine, leucine, phenylalanine, glutamine and proline (p<0.05). In conclusion, these results suggest that maintaining the appropriate lysine:DE ratio becomes more important as the energy density of the diet increases. Consequently, increasing the lysine:DE ratio can result in increased crude protein digestibility and urinary nitrogen excretion, although apparent protein digestibility and nitrogen excretion were not affected by energy density Furthermore, increasing the lysine:DE ratio also increased the apparent digestibility of essential amino acids, except for leucine, regardless of energy density. The optimum lysine:DE ratio for maximum essential amino acid digestibility of the $64.2{\pm}0.69kg$ pig is approximately 2.4 g of lysine/Mcal of DE.

Acoustic Properties of Bovine Cancellous Bone in the Frequency Range of 0.5-2 MHz

  • Lee Kang Il;Roh Heui-Seol;Yoon Suk Wang
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.373-376
    • /
    • 2002
  • Most previous studies using ultrasound for osteoporosis diagnosis have employed ultrasound in a frequency range of 0.2-1 MHz. In this study, acoustic properties of the 12 defatted bovine cancellous bone specimens were investigated in vitro. Speed of sound (SOS) and broadband ultrasonic attenuation (BUA) were measured using three matched pairs of transducers with the center frequencies of 1, 2.25, and 3.5 MHz, respectively, in order to cover a broad frequency range of 0.5-2 MHz. The relative orientation between ultrasonic beam and bone specimens was the mediolateral (ML) direction of the bovine tibia. SOS showed significant linear positive correlations with apparent density for all three pairs of transducers of 1 MHz, 2.25 MHz, and 3.5 MHz, respectively. BUA showed relatively weak correlations with apparent density for the pairs of transducers of 1 MHz and 2.25 MHz. Furthermore, in the measurement with the pair of 3.5 MHz transducers, BUA was independent of apparent density. SOS and BUA were only weakly correlated with each other. The linear combination of SOS and BUA showed significant correlations with apparent density. These results suggest that the frequency range up to 1.5 MHz may be also useful in the osteoporosis diagnosis.

  • PDF

Evaluation of Organic-Inorganic Hybrid Insulation Material Using Inorganic Filler and Polyurethane (무기질 충진재와 폴리우레탄을 활용한 유·무기 복합 단열소재의 특성 평가)

  • Lee, Jong-Kyu;Soh, Jung-Sub;Noh, Hyun-Kyung
    • Korean Journal of Materials Research
    • /
    • v.22 no.11
    • /
    • pp.604-608
    • /
    • 2012
  • Recently, inorganic-organic hybrid materials have attracted much attention not only for their excellent thermal conductivity but also for their flame retardant properties. In this study, the properties of organic-inorganic hybrid insulating materials using inorganic fillers and polyurethane foam with different foaming conditions have been investigated. The addition of 1.5 wt% water to polyurethane as foaming agent shows the best foaming properties. The pore size was decreased in the foaming body with increasing of the $CaCO_3$ addition. The apparent density and thermal conductivity were increased by increasing the $CaCO_3$ addition. With an increasing amount of $CaCO_3$ powder, the flame retardant property is improved, but the properties of thermal conductivity and apparent density tend to decrease. When the addition of fine particles of $CaCO_3$, the apparent density and thermal conductivity were increased and, also, with the addition of coarse particles over $45{\mu}m$ in size, the apparent density and thermal conductivity were increased as well. In this study, the adding of $CaCO_3$ with average particle size of $27{\mu}m$ led to the lowest thermal conductivity and apparent density. After evaluation with different inorganic fillers, $Mg(OH)_2$ showed the highest thermal conductivity; on the other hand, $CaCO_3$ showed the lowest thermal conductivity.

On Apparent Density and Flow Rate Measurement at Elevated Temperature for Powder Mixes Intended for Warm Compacting (온간성형용 분말의 고온 유동도와 겉보기 밀도 측정에 관하여)

  • Lee Jeong-Keun;Kim Soon-Wook
    • Journal of Powder Materials
    • /
    • v.13 no.1 s.54
    • /
    • pp.52-56
    • /
    • 2006
  • The aim of this work was to establish an optimal condition for determination of apparent density and flow rate for warm compacting powder. For this purpose it was evaluated uncertainty on them according to ISO Guide to the Expression of Uncertainty in Measurement. This evaluation example would be useful even in powder fluidity measurement at room temperature.