• Title/Summary/Keyword: anterior chamber depth

Search Result 15, Processing Time 0.022 seconds

Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth of 20 to 24 Years old population in Korea (한국인 20세부터 24세까지의 중심 각막 두께, 앞방 부피, 앞방 깊이에 대한 상관관계 분석)

  • Sang Yeul Park;Douk Hoon Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.12 no.1
    • /
    • pp.1654-1659
    • /
    • 2024
  • Purpose: The aim of this study was to determine Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth in Koreans aged 20 to 24 years using the Pentacam tool. Methods: The subjects of this study were 53 Korean adults with healthy eyes. The central corneal thickness(CCT), anterior chamber volume(ACV), and anterior chamber depth(ACD) was measured with Pentacam device. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 22.0±2.01 years. The mean +/- central corneal thickness of the right eye and left eye were 546.66±32.221mmg and 545.70±32.759mm, respectively. Also The mean central cornea thickness was 546.19 um in the whole sample. The mean anterior chamber volume the right eye and left eye was 181.66±33.738 mm3 and 180.12±30.84 mm3, respectively. The mean anterior chamber depth was 3.158±0.257 mm and 3.122±0.233 mm in right eye and left eye, respectively. There was a statistically significant difference between anterior camber volume and anterior chamber depth(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and anterior chamber volume. Also there was no statistically significant difference between central cornea thickness and anterior chamber depth. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adolescents.

Analysis of the Central Corneal Thickness and Anterior Chamber Depth of Eyes in Korean Young Population using the Pentacam (Pentacam을 이용한 한국 청소년 집단에서 각막의 중심두께와 전방깊이 분석)

  • Kim, Douk-Hoon;Bae, Han-Yong
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.2
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose. This study was to investigate the analysis of the central corneal thickness and anterior chamber depth of eyes in Korean Young Population using the Pentacam topography. Methods. The subjects consisted of 126 eyes from normal cornea of Korean aged 7-12($8.857{\pm}1.501$) years during 2009. The thinnest location, pachy apex, and pupil central region of the cornea thickness was measured using the Pentacam pachymetry. The anterior chamber depth of normal corneas was measured with Pentacam. Results. The thinnest location of corneal thickness was $547.413{\pm}37.893$um. The pachy apex of cornea thickness was $552.103{\pm}36.016$um. Also, the pupil center of corneal thickness was measured $552.143{\pm}36.418$um. On the other hand, the mean thickness in the central cornea was a statically significant relationship(t-test, p=0.0002) between pachy apex and thinnest zone. Also the mean thickness of the central cornea was a statically significant correlation(pearson p=0.0001) among the pupil center, pachy apex and thinnest zone. The anterior chamber depth was $3.137{\pm}0.308$mm. The mean depth in the anterior chamber of cornea was a statically relationship(t-test, p>0.05) between OD and OS. Conclusions. The results of this clinical study suggested that the analysis of the central corneal thickness and anterior chamber depth using Pentacam in Korean young population can provide the useful morphological information in diagnosis of cornea for the contact lens fitting and corneal refraction surgery.

  • PDF

Corneal Asphericity for Myopia in Korea (한국인 근시안의 각막 비구면성)

  • Kim, Hyo-Jin;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.109-114
    • /
    • 2006
  • We evaluated the contour using corneal asphericity of the myopic cornea in Korea and investigated the relationship between refractive error and other ocular dimensions in Korean myopia, including anterior chamber depth and asphericity. The monoocular asphericity value of 50 myopes with $-4.83{\pm}2.38$ D between early 20 age and early 30 age in adult was included. Cycloplegic refraction, corneal asphericity and anterior chamber depth using corneal topography were examined. The mean asphericity values were$-0.27{\pm}0.13$ and the corneas of 96.0% were prolate ellipse. Refractive error was related to asphericity and anterior chamber depth among myopes. However, asphericity only were significant difference in high and low myopia group. Corneal configuration on the contact lens fits are discussed. We think that the longitudinal study for myopia and asphericity was required.

  • PDF

Study of Ocular Optical Components (안구의 광학적 구조에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.139-144
    • /
    • 2000
  • In this study, anterior corneal radius of curvature in korean subjects aged between 16 to 79 year-olds were measured using a keratometer. Refractive power was also measured without cyloplegia. A-mode Ultrasonography was used to measure anterior chamber depth, crystalline lens thickness, vitreous chamber depth & axial length. Measurements of anterior chamber depth of subjects in their 20s were between 3.0 mm & 4.0 mm, 70s age group were between 2 mm & 3.50 mm, showing a decrease with age. Crystalline lens thickness of 20s age group was 2.64 mm while 70s age group was 4.62 mm showing an increase with age. Vitreous chamber depth, unaffected by age, was about 17 mm. Axial length was 24.47 mm in subjects below 40s age groups decreasing to 24.11 mm in above 40s age groups. Corneal radius of curvature was 7.79 mm and 7.72 mm in younger and older age groups respectively, showing a decrease with age.

  • PDF

The Correlation of Refractive Error and Ocular Dimensions in Older Age (고령의 연령에서 굴절이상과 안광학 성분들의 연관성 분석)

  • Lim, Byung Kwan;Jeon, Soon-Woo;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.293-297
    • /
    • 2011
  • Purpose: This study was to know the correlation among refractive error and the dimensions of ocular components on older adults. Methods: The subjects were 95 older age who had no eye diseases. The refractive error, corneal radius, corneal diopter, axial length, anterior chamber depth and lens thickness were measured and analysed. Results: The axial length(AL)/corneal radius(CR) ratio was positively correlated with the corneal diopter, axial length, the anterior chamber depth. Then it was negatively correlated with corneal radius. It was shown that the highest correlation was between the corneal diopter and axial length (r = -0.545, p = 0.000). The spherical equivalent of the refractive error was negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the old age.

Analysis on Ocular Components Variation with the Difference of Both Refractive Errors (양안 굴절이상 차이에 의한 안광학상수 변화도 분석)

  • Lee, Hae-Jung;Lee, Eun-Hee;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.435-440
    • /
    • 2016
  • The aim of study was to provide the preliminary data to find out characteristics of the difference between both refractive errors through analysis of ocular components variation. We measured spherical equivalent power and corneal radius with KR-8800, and axial length and anterior chamber depth with IOL Master, and the difference of measuring values between the right eye and left eye was applied as the absolute values in 100 adults aged 20~59 years. In all participants, the most common results showed that spherical equivalent power was $-1.83{\pm}2.17D$, axial length was 23.00~24.99mm, corneal radius was 7.50~7.89mm, and anterior chamber depth was 3.60~4.09mm. There are significant correlations between both eyes in axial length and anterior chamber depth with the difference of both spherical equivalent power. The difference of both axial lengths was the biggest with the difference of both refractive errors, and shown the highest correlation. The convergence complex study through classification by aspects is needed since the difference of both refractive errors is closely related with ocular components variation, and poor visual function would be caused by the difference of both refractive errors.

Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • Journal of Korean Clinical Health Science
    • /
    • v.6 no.1
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.

Study of the Correlation and Ocular Components in Preschool Children (취학전 어린이들의 안광학 성분 측정 및 상관성 분석)

  • Jeon, Soon-Woo;Hwang, Hye-Kyung;Lee, Sun Haeng;Park, Chun-Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.201-206
    • /
    • 2010
  • Purpose: This study was to know the correlation among the dimensions of ocular components and refractive error on kindergarten children. Methods: The subjects were 80 preschool students who had no eye diseases. The refraction, corneal diopter, corneal radius, inter-pupillary distance, axial length, anterior chamber depth and dominant eye were measured and analysed. Results: It was shown that the highest correlation was between the axial length and the corneal diopter (r=-0.674, p=0.000). The ratio of height, weight and axial length (AL) to Corneal radius (CR) ratio were positively correlated with the axial length (r=0.351, r=0.408, r=0.488). The spherical equivalent of the refractive error and the corneal diopter were negatively correlated with the axial length (r=-0.302, r=-0.674). The anterior chamber depth and the corneal diopter were positively correlated with the AL/CR ratio (r=0.422, r=0.280). The spherical equivalent of the refractive error and the corneal radius were negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the preschoolers.

A Clinical Study of Ocular Dimention and Visual Acuity Before and After Cataract Surgery Over Ninety Years Old (90세 이상 초고령 환자들의 백내장 수술전.후 안수치와 시력에 관한 임상연구)

  • Lee, Jung-Mi;Kim, In-Suk;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 2010
  • Propose: Due to the rapid growth of medical technologies and the increasing population of older people, we investigated clinical status of ocular dimensions and visual acuity for pre and post cataract surgeries of people over age 90. Methods: From March 2007 to February 2009, we investigated eighty-two eyes of forty-eight patients who had undergone cataract surgeries at an ophthalmic clinic (Ansung, Kyungi-do), investigated maximum corrected vision, axial length, anterior chamber depth and accompanied ocular diseases before and after the surgeries based on the collected data. Results: As patients aged, axial length unchanged but anterior chamber depth decreased over all due to the increase of intraocular lens thickness, and men tended to have a higher degree than women. Seventy-one (86.6%) of eighty-two eyes showed improved corrected vision than before surgeries and forty-three (52.4%) eyes could see more than visual acuity of 0.5. Conclusions: Patients with the systemic disease and accompanied ocular disease showed low vision less than 0.5 after cataract surgery compared to same healthy age peoples. But the others improved correction visual acuity more than 0.5, so the cataract surgery was surely necessary for people over 90 years old and also the presence of ocular disease could have a great influence on correction visual acuity.

The Correlation of Myopic Refractive Error and Ocular Components in Primary School Students (초등학생의 근시성 굴절이상과 안광학 성분들의 관련성)

  • Jeon, Soon-Woo;Lee, Hyun-Joo;Hwang, Hye-Kyung;Park, Chun-Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.299-303
    • /
    • 2012
  • Purpose: In this study the correlation among the myopic refractive error and ocular components in primary school students was investigated. Methods: The subjects were 62 children who had no eye diseases. The refractive error, corneal radius, anterior chamber depth, lens thickness, axial length were measured and analysed. Results: Myopic refractive error in primary school students was negatively correlated with the axial length (1~3rd grade r=-0.653, p=0.000/4~6th grade r=-0.742, p=0.000), AL/CR ratio (1~3rd grade r=-0.571, p=0.000/4~6th grade r=-0.852, p=0.000). Conclusions: It was shown that the axial length and axial length(AL)/corneal radius(CR) ratio were very important data for myopic refractive error in primary school students.