• Title/Summary/Keyword: and VP9

Search Result 211, Processing Time 0.02 seconds

Determination of the Effective Energy of X-Ray Beam Using Optically Stimulated Luminescent nanoDot Dosimeters (광자극형광나노닷선량계를 사용한 X선 빔의 유효에너지 결정)

  • Kim, Jongeon;Lee, Sanghun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.375-379
    • /
    • 2015
  • The purpose of this study is to determine the effective energy of a polyenegetic X-ray beam. The half value layer(HVL) of aluminum for 80 kVp X-ray beam was measured by using optically stimulated luminescent nanoDot dosimeters(OSLnDs). The linear attenuation coefficient(${\mu}$) was calculated using the measured HVL. And the mass attenuation coefficient(${\mu}/{\rho}$) was obtained by dividing the linear attenuation coefficient by the density(${\rho}$) of aluminum. The effective energy($E_{eff}$) of the obtained mass attenuation coefficient was determined using data of the X-ray mass attenuation coefficients for photon energies of aluminum given by National Institute of Standards and Technology(NIST). As a result, the HVL value is 2.262 mmAl. The ${\mu}$ value is $3.06cm^{-1}$. The ${\mu}/{\rho}$ value is $1.114cm^2/g$. And the $E_{eff}$ value was determined at 29.79 keV.

Evaluation of Compost Qualities with or without Microbial Inoculation for Food Waste Composting (미생물제 첨가유무에 따른 음식물 쓰레기 퇴비 부숙도 평가)

  • Jeong, Jun-Young;Jung, Kwang-Yong;Nam, Sung-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.3
    • /
    • pp.280-286
    • /
    • 1999
  • This studies were conducted to evaluate efficiency of microbial inoculator for active composting of food wastes. The Microbial inoculators used in this studies were purchased from different comparise to evaluate their effectiveness for composting of food waste in Korea. The number of bacteria growing at $30^{\circ}C$ in commercial inoculator collected were below $91.0{\times}10^8\;CFU/g$ which were counted from well cured compost made by animal manure. The number of bacteria in commercial microbial inoculator, such as FL, VP, B9, CM and GE were higher than that of composted at $50^{\circ}C$ or $60^{\circ}C$ of incubation temperature. Fungi were counted in GR, VP and B9 as over $10^3CFU/g$ at $30^{\circ}C$ of incubation temperature, while fungi of all the commercial inoculator collected could not grown at $50^{\circ}C$ and $60^{\circ}C$. Actinomycetes in most of the these had higher number($10^5CFU/g$) than that of compost : however, it was not detected at $60^{\circ}C$ incubation temperature from all the samples collected. The amount of carbon dioxid production was order to VP>HU>B9>GE>CM>Control>Compost in the lab scale composting test with or without inoculation of commercial inoculators, however, but the difference in carbon dioxide production was similar among each treatments. The effect of inoculation on composting parmeter such as pH changes, temperature increasing and change of chemicals properties were a little among each treatments, with or without inoculation of commercial inoculator in active composting of food waste. Using commercial inoculator did not show any statistical difference in food waste composting process under various condition such as pH changes, temperature changes, etc.

  • PDF

Evaluation of Sodium Lactate and Potassium Lactate on the Quality Characteristics and Shelf-life of Low-fat Sausage during Refrigerated Storage (젖산나트륨과 젖산칼륨의 첨가가 냉동저장 중 저지방 소시지의 품질특성 및 저장성에 미치는 영향)

  • Chin Koo Bok;Ahn Eun Ha
    • Food Science of Animal Resources
    • /
    • v.25 no.1
    • /
    • pp.52-59
    • /
    • 2005
  • This study was performed to investigate physicochemical and textural characteristics, and antimicrobial effect for Listeria monocytogenes (LM) in low-fat functional sausages (LFFS) containing sodium lactate (SL) and potassium lactate (PL) during storage at 4℃ for 10 weeks. The LFFS treatments included CTL (Low-fat sausage control), TRT1 (SL 3.3%), TRT2 (SL 2.2% + PL 1.1%), TRT3 (SL 1.1% + PL 2.2%), TRT4 (PL 3.3%). Proximate composition for LFFS were 73.9∼75.2% moisture, 1∼2% fat and 15.5∼15.9% protein, and pH values ranged from 5.8 to 6.5. Expressible moisture (EM, %) and vacuum purge (VP, %) ranged from 22.9 to 33.0 and from 2.7 to 5.3, respectively. EM of CTL, TRT1 and TRT2 increased with increased storage time, however, no differences in VP were observed during storage time. Hunter color values (L, a, b) were not affected by the addition of SL and PL, and storage time (p>0.05). Most textural properties of LFFS were not affected by the addition of SL and PL, except for few cases, but those of CTL tended to increase with increased storage time. The addition of SL and PL into LFFS, alone or in combination, inhibited the microbial growth of inoculated LM during refrigerated storage, resulting in longer shelf-life than the control.

The Complementizer That-Deletion in English

  • Kim, Yangsoon
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.112-116
    • /
    • 2021
  • The aim of this study is to analyze the complementizer that-deletion in embedded complement clauses in English. This paper is concerned with the alternation between the overt that-complementizer and the zero complementizer by the complementizer deletion (C-deletion or that-deletion) in constructions with a nominal complement that-clause, i.e. [VP Verb [CP that-TP]]. In this paper, we compare that-complementation and zero-complementation in a diachronic grammaticalization and corpus, and show that the complementizer that has its origin in pronouns diachronically and finally becomes to form a C-head of the functional category CP. We provide the syntactic and semantic explanation on the optionality of that-deletion while answering the question why and how that-deletion is getting increasing in use especially with the verb, think, in the informal contexts. With the major causes for the currently increasing use of that-deletion, we are concerned with the contexts in which the overt complementizers or the covert complementizers are preferred.

Design and Fabrication of Second-Order Multibit Sigma-Delta Modulator (2차 멀티비트 Sigma-Delta 변조기 설계 및 제작)

  • 김선홍;최석우;조성익;김동용
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.9
    • /
    • pp.650-656
    • /
    • 2004
  • This paper presents block and timing diagrams of the DWA(data weighted averaging) to optimize a feedback time delay of the sigma-delta modulator. Through the Matlab modeling, the optimized coefficients of the integrators are obtained to design the modulator. And then the fully differential SC integrators, feedback DAC, 9-level quantizer, and DWA are designed by considering the nonideal characteristics of the modulator. The designed second-order multibit modulator is fabricated in a 0.35$\mu\textrm{m}$ CMOS process. The designed modulator achieves 73dB signal-to-noise ratio and 72dB dynamic range at 1.2Vp-p 585kHz input singal and 52.8MHz sampling frequency.

Comparative Outcome of Thai Pediatric Osteosarcoma Treated with Two Protocols: the Role of High-Dose Methotrexate (HDMTX) in a Single Institute Experience

  • Choeyprasert, Worawut;Pakakasama, Samart;Sirachainan, Nongnuch;Songdej, Duantida;Chuansumrit, Ampaiwan;Anurathapan, Usanarat;Hongeng, Suradej;Nartthanarung, Adisak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9823-9829
    • /
    • 2014
  • Background: High-dose methotrexate (HD-MTX) is recognized as an efficient component of therapy against pediatric osteosarcoma in combination with other drugs such as cisplatin (CDP), carboplatin (CBDCA), doxorubicin (ADM), etoposide (VP-16) and ifosfamide (IFO). Objectives: To demonstrate the feasibility and effectiveness of the HD-MTX/CDP/DOX/VP-16/IFO [MTX(+)] protocol comparable to CDP/ADM/CBDCA/IFO [MTX(-)] for treating childhood osteosarcoma at Ramathibodi Hospital (1999-2014). Materials and Methods: A retrospective analysis was conducted of osteosarcoma patients aged less than 18 years treated with two chemotherapeutic regimens between 1999 and 2014. A total of 45 patients received the MTX(-) and 21 the MTX(+) protocol. Results: Overall limb-salvage and amputation rate were 12.9% and 77.7%, respectively. Kaplan-Meier analysis results for 3-year disease free survival (DFS) and overall survival (OS) regardless of treatment regimens were $43.4{\pm}6.0%$ and $53.2{\pm}6.1%$ respectively. The 3-year DFS and OS were improved significantly with the MTX(+) protocol compared to MTX(-) protocol (p=0.010 and p=0.009, log rank test) [$69.8{\pm}10.5%$, $79.8{\pm}9.1%$ for MTX(+) and $31.1{\pm}6.9%$, $42.2{\pm}7.4%$ for MTX(-) protocol, respectively]. Patients with metastatic osteosarcoma treated with the MTX(+) protocol had statistically significant higher 3-year DFS and OS than those treated with the MTX(-) protocol ($66.7{\pm}13.6%$ and $15.0{\pm}8.0%$ for 3-year DFS, p=0.010, $73.3{\pm}13.2%$ and $20{\pm}8.9%$ for 3-year OS, p=0.006, respectively). The independent risk factors for having inferior 3-year DFS and OS were poor histological response (tumor necrosis <90%) and treatment with the MTX(-) protocol. The multivariate analysis identified only the treatment with the MTX(-) protocol as an independent predictor of inferior OS with a hazard ratio (HR) of 3.53 (95% confidence interval of 1.2-10.41, p=0.022). Conclusions: Our study demonstrated the tolerability, feasibility and efficacy of the HDMTX-based regimen improving the survival rate in pediatric osteosarcoma cases, in line with reports from developed countries.

Impact of Packaging Methods Coupled with High Barrier Packaging Loaded with TiO2 on the Preservation of Chilled Pork

  • Xiaoyu Chai;Dequan Zhang;Yuqian Xu;Xin Li;Zhisheng Zhang;Chengli Hou;Weili Rao;Debao Wang
    • Food Science of Animal Resources
    • /
    • v.44 no.5
    • /
    • pp.1142-1155
    • /
    • 2024
  • This study investigated the impact of packaging methods coupled with high barrier packaging loaded with titanium dioxide (TiO2) on the quality of chilled pork. The experiment consisted of three treatment groups: air packaging (AP), vacuum packaging (VP), and vacuum antibacterial packaging (VAP). Changes in total viable count (TVC), pH value, total volatile basic nitrogen (TVB-N) value, sensory attributes, and water holding capacity of pork were analyzed at 0, 3, 6, 9, and 12 d. TVC of the VAP group was 5.85 Log CFU/g at 12 d, which was lower than that of AP (6.95 Log CFU/g) and VP (5.93 Log CFU/g). The antibacterial film incorporating TiO2 effectively inhibited microorganism growth. The VAP group exhibited the lowest pH value and TVB-N value among all the treatment groups at this time. The findings demonstrated that the application of VAP effectively preserved the sensory attributes of pork, the hardness, cohesiveness and adhesiveness of pork in VAP group were significantly superior than those in AP group (p<0.05), but not significantly compared with VP group. On the 12 d, the CIE a* value of pork in VAP group was significantly higher (p<0.05). This exhibited that VAP could effectively maintain the freshness of chilled pork and extend the shelf life for 3 d compared to the AP group. These findings provide empirical evidence to support the practical implementation of TiO2-loaded packaging film in the food industry.

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography (Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향)

  • Kwon, Soonmu;Park, Changhee;Park, Jeongkyu;Son, Woonheung;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • Chest radiography has been typically performed at SID of 180 cm. Image quality and patient dose were investigated between 180 cm and 340 cm by 20 cm intervals at 120 kVp and 320 mAs with the AEC. VGA was performed for qualitative assessment and SNR was analysed for quantitative assessment on the image of the chest phantom. Patients dose was measured by ESAK and PCXMC was used for effective dose. As a result, when using the standard of SID of 180 cm which is typically used in the clinical practice, in the case of ESAK, 240 cm, 280 cm, and 320 cm were 8.7%, 11.47%, and 13.56% respectively therefore significant reduction was confirmed. In the case of effective dose, 2.89%, 4.67%, and 6.41% in the body and 5.08%, 6.09%, and 9.6% in lung were reduced. In the case of SNR, 9.04%, 8.24%, and 11.46% were respectively decreased especially, by 8.03% between SID of 260 cm and 300 cm, but SNR was 5.24 up to 340 cm. There were no significant differences in VGA thus the image is valuable in diagnosis. It is predicted that increasing SID up to 300 cm in digital chest radiography can reduce patient dose without decreasing image quality.

Structure and physical properties of Earth Crust material in the Middle of Korean Peninsula(2) : Comparison between elastic Velocity and point-load of core specimen of sedimentary rocks. (한반도 중부권 지각물질의 구조와 물성연구(2) : 퇴적암류 코아시료의 탄성파 속도와 점재하 강도 비교)

  • 송무영;황인선
    • The Journal of Engineering Geology
    • /
    • v.3 no.1
    • /
    • pp.21-37
    • /
    • 1993
  • In order to investigate the correlation of sedimentary rock properties. specific gravity, porosity, water content, sonic wave velodty, and point4oad strength index of core samples of limestones, sandstones and shales were measured. The relationships between density and velocity show $V_p=16300d-38719.3,{\;}V_s1896.4d-29225.1$ of regression equation for sandstones and $Vp=4085d-10264.8,{\;}V_s=3519d-7841.3$ for shales and <$Vp=4085d^2-20747d+303,{\;}V_s=3899d^2-21442d+318$ for limestones. Seismic wave velocity of shales which have high density is lower than that of sandstones, and this seems to be an effect of bedding in shale. P-wave velocity and S-wave velocity of limestones, sandstones and shales show the linear relationships as a whole. The regression equations are respectively calculated V_s=0.26V_p+1041.6m/sec,{\;}V_s=0.43V_p+424.2m/sec,{\;}and{\;}Vs=0.51V_p+261.9m/sec$ and the correlation coefficients of the velocity show r= 0.86 in sandstones, r= 0.75 in limestones and r=0.86 in shales. According to the point4oad strength test for limestones, point4ord strength anisotropy was not so dear even though the specimens show generally the banded structure. Variations of dip angle of bedding whihin the range $30^{\circ}-60^{\circ}$ does not have much influence upon the diametral strength index and axial strength index. From the result of point load test, P-wave velocity increases with point4ord strength index but the regression equations are $V_p=98.5lI{s_d}+4082.1m/sec,{\;}V_p=106.41{s_a}+3954m/sec$ and their correlation coefficient is low.

  • PDF