• Title/Summary/Keyword: analytical verification

Search Result 349, Processing Time 0.024 seconds

Derivation of Analytic Formulas and Numerical Verification of Weakly Singular Integrals for Near-Field Correction in Surface Integral Equations

  • Rim, Jae-Won;Koh, Il-Suek
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.2
    • /
    • pp.91-97
    • /
    • 2017
  • An accurate and efficient evaluation for hypersingular integrals (HIs), strongly singular integrals (SSIs), and weakly singular integrals (WSIs) plays an essential role in the numerical solutions of 3D electromagnetic scattering problems. We derive analytic formulas for WSIs based on Stokes' theorem, which can be expressed in elementary functions. Several numerical examples are presented to validate these analytic formulas. Then, to show the feasibility of the proposed formulations for numerical methods, these formulations are used with the existing analytical expressions of HIs and SSIs to correct the near-field interaction in an iterative physical optics (IPO) scheme. Using IPO, the scattering caused by a dihedral reflector is analyzed and compared with the results of the method of moments and measurement data.

Generalized Selective Harmonic Elimination Modulation for Transistor-Clamped H-Bridge Multilevel Inverter

  • Halim, Wahidah Abd.;Rahim, Nasrudin Abd.;Azri, Maaspaliza
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.964-973
    • /
    • 2015
  • This paper presents a simple approach for the selective harmonic elimination (SHE) of multilevel inverter based on the transistor-clamped H-bridge (TCHB) family. The SHE modulation is derived from the sinusoidal voltage-angle equal criteria corresponding to the optimized switching angles. The switching angles are computed offline by solving transcendental non-linear equations characterizing the harmonic contents using the Newton-Raphson method to produce an optimum stepped output. Simulation and experimental tests are conducted for verification of the analytical solutions. An Altera DE2 field-programmable gate array (FPGA) board is used as the digital controller device in order to verify the proposed SHE modulation in real-time applications. An analysis of the voltage total harmonic distortion (THD) has been obtained for multiple output voltage cases. In terms of the THD, the results showed that the higher the number of output levels, the lower the THD due to an increase number of harmonic orders being eliminated.

Modified Disturbed State Concept for Dynamic Behaviors of Fully Saturated Sands (포화사질토의 동적거동규명을 위한 수정 교란상태개념)

  • 최재순;김수일
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.107-114
    • /
    • 2003
  • There are many problems in the prediction of dynamic behaviors of saturated soils because undrained excess pore water pressure builds up and then the strain softening behavior is occurred simultaneously. A few analytical constitutive models based on the effective stress concept have been proposed but most models hardly predict the excess pore water pressure and strain softening behaviors correctly In this study, the disturbed state concept (DSC) model proposed by Dr, Desai was modified to predict the saturated soil behaviors under the dynamic loads. Also, back-prediction program was developed for verification of modified DSC model. Cyclic triaxial tests were carried out to determine DSC parameters and test result was compared with the result of back-prediction. Through this research, it is proved that the proposed model based on the modified disturbed state concept can predict the realistic soil dynamic characteristics such as stress degradation and strain softening behavior according to dynamic process of excess pore water pressure.

  • PDF

A unified method for stresses in FGM sphere with exponentially-varying properties

  • Celebi, Kerimcan;Yarimpabuc, Durmus;Keles, Ibrahim
    • Structural Engineering and Mechanics
    • /
    • v.57 no.5
    • /
    • pp.823-835
    • /
    • 2016
  • Using the Complementary Functions Method (CFM), a general solution for the one-dimensional steady-state thermal and mechanical stresses in a hollow thick sphere made of functionally graded material (FGM) is presented. The mechanical properties are assumed to obey the exponential variations in the radial direction, and the Poisson's ratio is assumed to be constant, with general thermal and mechanical boundary conditions on the inside and outside surfaces of the sphere. In the present paper, a semi-analytical iterative technique, one of the most efficient unified method, is employed to solve the heat conduction equation and the Navier equation. For different values of inhomogeneity constant, distributions of radial displacement, radial stress, circumferential stress, and effective stress, as a function of radial direction, are obtained. Various material models from the literature are used and corresponding temperature distributions and stress distributions are computed. Verification of the proposed method is done using benchmark solutions available in the literature for some special cases and virtually exact results are obtained.

Finite Element Model Verification of Buckling Restrained Brace With Nonlinear Behavior (비선형 거동을 하는 비좌굴가새의 유한요소모델 검증)

  • Kim, Dae-Hong;Yoo, Jung-Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.2
    • /
    • pp.81-88
    • /
    • 2021
  • In this paper, nonlinear finite element analysis was conducted based on the experimental results on buckling restrained brace. The reliability of the analytical model was verified by comparing the results of experimental studies with hysteresis loop, bi-linear curve, cumulative energy dissipation capacity, and equivalent viscous damping. A valid finite element model has been secured and will be used as basic data for finite element analysis of buckling restrained braces in the future.

Verification of Radiation and Beam-Steering Characteristics for Planar-Phased Array Radars Using Near-Field Beam Focusing (근전계 빔 집속 시험 기법을 활용한 평면위상배열레이다 시스템 복사 및 빔 조향 특성 검증)

  • Kim, Young-Wan;Lee, Jaemin;Jung, Chae-Hyun;Park, Jongkuk;Lee, Yuri;Kim, Jong-Phil;Kim, Sunju
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.160-168
    • /
    • 2019
  • In this study, we propose a verification method for a planar-phased array radar system using a near-field beam focusing(NFBF) test method. We then confirmed the validity of the results. The proposed method can be used to verify a radar system in the near-field range of twice the antenna aperture size, and this is done in the same manner as the field system performance test conducted in a non-outdoor electromagnetic anechoic chamber. The test configuration and procedure for verifying the NFBF using near-field energies were reviewed. In addition, the phase compensation values of additional individual channels were quantified through mathematical verification of the beam-steered NFBF test. Based on a theoretical verification, the actual NFBF test was performed and the validity of the test method was confirmed through comparison with ideal analytical results.

Standardization for Analysis Method of Total Polyphenol in Complex of Picao Preto (피카오프레토 등 복합물 중 총 폴리페놀 분석법 표준화)

  • Hu, Soojung;Kim, Ji-An;Moon, Myung-Hee;Lee, Sung-Hye;Yoon, Hae-Seong;Hong, Jin-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • As generic health functional food items have been expanded, this research project has been conducted to prepare a scientific and systematic standardized analytical method of relevant food item and examine the suitability of the method for health/functional foods on sale. Total polyphenol was necessary for development and verification of standardized analytical method. The method exhibited high linearity in the tannic acid calibration curve ($r^2$ > 0.999) over concentrations of $5-50{\mu}g/mL$. The limits of detection and quantitation for tannic acid were $5{\mu}g/mL$ and $15{\mu}g/mL$, respectively, while tannic acid recovery was 102.3-112.4% with standard deviations of 0.8-3.2%. To verify the accuracy of the analytical method, the labeled amounts of purchased health functional foods were monitored. The recovery for tannic acid was 105.6% of the labeled amounts. Thus, the new method was suitable for all cases.

Comparison Analysis of Patient Specific Quality Assurance Results using portal dose image prediction and Anisotropic analytical algorithm (Portal dose image prediction과 anisotropic analytical algorithm을 사용한 환자 특이적 정도관리 결과 비교 분석)

  • BEOMSEOK AHN;BOGYOUM KIM;JEHEE LEE
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.15-21
    • /
    • 2023
  • Purpose: The purpose of this study is to compare the performance of the anisotropic analytical algorithm (AAA) and portal dose image prediction (PDIP) for patient-specific quality assurance based on electronic portal imaging device, and to evaluate the clinical feasibility of portal dosimetry using AAA. Subjects and methods: We retrospectively selected a total of 32 patients, including 15 lung cancer patients and 17 liver cancer patients. Verification plans were generated using PDIP and AAA. We obtained gamma passing rates by comparing the calculated distribution with the measured distribution and obtained MLC positional difference values. Results: The mean gamma passing rate for lung cancer patients was 99.5% ± 1.1% for 3%/3 mm using PDIP and 90.6% ± 5.8% for 1%/1 mm. Using AAA, the mean gamma passing rate was 98.9% ± 1.7% for 3%/3 mm and 87.8% ± 5.2% for 1%/1 mm. The mean gamma passing rate for liver cancer patients was 99.9% ± 0.3% for 3%/3 mm using PDIP and 96.6% ± 4.6% for 1%/1 mm. Using AAA, the mean gamma passing rate was 99.6% ± 0.5% for 3%/3 mm and 89.5% ± 6.4% for 1%/1 mm. The MLC positional difference was small at 0.013 mm ± 0.002 mm and showed no correlation with the gamma passing rate. Conclusion: The AAA algorithm can be clinically used as a portal dosimetry calculation algorithm for patientspecific quality assurance based on electronic portal imaging device.

  • PDF

Enhancing the Reliability of OTT Viewing Data in the Golden Age of Streaming: A Small Sample AHP Analysis and In-Depth Interview

  • Seung-Chul Yoo;Yoontaek Sung;Hye-Min Byeon;Yoonmo Sang;Diana Piscarac
    • International journal of advanced smart convergence
    • /
    • v.12 no.1
    • /
    • pp.140-148
    • /
    • 2023
  • With the OTT media market growing rapidly, the significance of trustworthy data verification and certification cannot be emphasized enough. This study delves into the crucial need for such measures in South Korea, exploring the steps involved, the technological and policy-related considerations, and the challenges that may arise once these measures are put into place. Drawing on in-depth interviews and the analytical hierarchy process (AHP), this study surveyed various stakeholder groups, both directly and indirectly related to OTT data authentication and certification. By assessing the severity of OTT data-related issues and identifying the requirements for reliability-improvement policies, participants shared their valuable insights and opinions on this pressing matter. The survey results clearly indicate a divided opinion among stakeholders and industry experts on the reliability of OTT data, with some expressing trust while others remain skeptical. However, there was a consensus that advertising-based AVOD is more reliable than SVOD. By analyzing the priorities of authentication and verification, this study paves the way for the establishment and operation of a Korean MRC (KMRC), centered on the OTT media industry. The KMRC will serve as a vital platform for ensuring the authenticity and accuracy of OTT data in South Korea, providing businesses and industry players with a reliable source of information for informed decision-making. This study highlights the pressing need for reliable data authentication and certification in the rapidly growing OTT media market, and provides a persuasive case for the establishment of a KMRC in South Korea to meet this critical need.

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF