• Title/Summary/Keyword: amplitude margin

Search Result 37, Processing Time 0.026 seconds

Embodiment of Low Operating Voltage in Positive Column AC-PDPs

  • Kim, Hyun;Tae, Heung-Sik;Chien, Sung-Il
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.95-98
    • /
    • 2003
  • The positive column discharge characteristics in the long gap (440 ${\mu}m$) are investigated based on the voltage distribution among three electrodes. In particular, the effects of the amplitude and width of the short pulse applied to the address electrode on the positive column discharge characteristics are examined intensively. By proper controlling of the amplitude and width of the address short pulse, it is found that the positive column discharge in the long gap is well constructed. As a result, under the stable static voltage margin condition, the firing and sustaining voltages are as low as those of conventional short gap(60 ${\mu}m$) discharge($V _f=220V$, $V_s=150V$) and the color purity is improved. Moreover, the luminous efficiency increases up to 60% in comparison with the conventional case.

  • PDF

Effects of Load Center of Gravity and Feet Positions on Peak EMG Amplitude at Low Back Muscles While Lifting Heavy Materials (중량물 들기 작업시 물체 무게중심 및 발의 위치가 허리 근육의 최대 EMG 진폭에 미치는 영향)

  • Kim, Sun-Uk;Han, Seung Jo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.257-264
    • /
    • 2012
  • Objectives: This study's aims were to evaluate the effects of load center of gravity within an object lifted and feet placements on peak EMG amplitude acting on bilateral low back muscle groups, and to suggest adequate foot strategies with an aim to reducing low back pain incidence while lifting asymmetric load. Methods: The hypotheses that asymmetric load imposes more peak EMG amplitude on low back muscles contralateral to load center of gravity than symmetric load and maximum peak EMG amplitude out of bilateral ones can be relieved by locating one foot close to load center of gravity in front of the other were established based on biomechanics including safety margin model and previous researches. 11 male subjects were required to lift symmetrically a 15.8kg object during 2sec according to each conditions; symmetric load-parallel feet (SP), asymmetric load-parallel feet (AP), asymmetric load-one foot contralateral to load center of gravity in front of the other (AL), and asymmetric load-one foot ipsilateral to load center of gravity in front of the other (AR). Bilateral longissimus, iliocostalis, and multifidus on right and left low back area were selected as target muscles, and asymmetric load had load center of gravity 10cm deviated to the right from the center in the frontal plane. Results: Greater peak EMG amplitude in left muscle group than in right one was observed due to the effect of load center of gravity, and mean peak EMG amplitudes on both sides was not affected by load center of gravity because of EMG balancing effect. However, the difference of peak EMG amplitudes between both sides was significantly affected by it. Maximum peak EMG amplitude out of both sides and the difference of peak EMG amplitude between both sides could be reduced with keeping one foot ipsilateral to load center of gravity in front of the other while lifting asymmetric load. Conclusions: It was likely that asymmetric load lead to the elevated incidence of low back pain in comparison with symmetric load based on maximum peak EMG amplitude occurrence and greater imbalanced peak EMG amplitude between both sides. Changing feet positions according to the location of load center of gravity was suggested as one intervention able to reduce the low back pain incidence.

An Experimental Assessment of Combustion Stability of Coaxial Swirl Injectors and an Impinging Injector through Simulating Combustion Test (상압기상연소시험을 통한 동축형 스월 분사기와 충돌형 분사기의 연소 안정성 평가)

  • Park, Junhyeong;Kim, Hongjip
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2017
  • High-frequency combustion instabilities may occur during the development of feasible engine combustors. These instabilities can result in irreparable damages to the wall of combustors or the degradation of engine performance. So, it is essential to identify injectors that have high stability characteristics during the early stages of development. The objective of present study was to assess the stability of coaxial injectors and an impinging injector with different recess lengths in order to develop stable injectors optimally. Stability margin was evaluated based on the distance from operating condition to the unstable regions. A simulating combustion test method was used to analyze the stability of injectors. A small-scale combustion chamber was designed to simulate the first tangential acoustic mode of the actual combustor. Gaseous oxygen and a mixture of methane and propane were used as simulant propellants to satisfy their flow similarity to the actual propellants of a combustor in a liquid rocket combustor. The results indicated that injectors having small recess lengths showed relatively large combustion stability margins. For the injectors of large recess lengths, instability regions with large and super-large amplitude oscillations were observed. Thus, injector with shorter recess lengths had a higher stability than that of longer one due to the different mixing processes.

AVO analysis on BSR in the northern regions of the South Shetland Islands, Antarctica (남극 남쉐틀랜드 북부지역에서 나타나는 BSR의 AVO 반응분석)

  • Goo, Kyoung-Mo;Hong, Jong-Kuk;Jin, Young-Keun;Lee, Joo-Han;Lee, Jung-Mo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.157-162
    • /
    • 2007
  • Geophysical survey has been conducted on the continental margin off the South Shetland Islands aboard R/V Onnuri of KORDI in 1992/1993. About 800-line km of 96-channel reflection data have been acquired. On the seismic section, BSR with strong reflectivity and negative polarity has been found at 700 ms below the sea bottom. BSR is considered as the base of gas hydrates and AVO analysis was performed to study physical properties along BSR. True amplitude recovery and surface consistence amplitude were applied to seismic data and angle gathers were obtained. AVO gradient and AVO intercept are calculated on every CDP gather. Section of AVO intercept show strong reflectivity and negative polarity on BSRs and stronger continuity of BSR than stacked section. Cross plot of intercept-gradient indicates that the lower layer below BSR is filled with free gas.

  • PDF

Study on the Critical Current of Field Coil for High Temperature Superconducting Motor (고온초전도 전동기용 계자코일의 임계전류 연구)

  • Jo, Young-Sik;Sohn, Myung-Whan;Baik, Seung-Kyu;Kwon, Woon-Sik;Lee, Eon-Yong;Kwon, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.873-875
    • /
    • 2003
  • It is well known that $I_c$ (critical current) in HTS tape is more sensitive to $B{\perp}$ (magnetic field amplitude applied perpendicular to the tape surface) than to B// (magnetic field amplitude applied parallel to the tape surface). Thus, the magnitude of $B{\perp}$ at HTS tape is important to the design of HTS motor, because it determines the operating current. In addition, the $I_c$ of HTS field coil is determined by not only the $B{\perp}$ but also stress and strain condition at given operating temperature. Therefore, at the stage of field coil design, stress and strain conditions should be considered because when the HTS tape is handled, it is necessary to know the limiting values of loading, bending and twisting to avoid any damages. The $I_c$ of field coil is calculated by 3D analysis and measured through experiments considering the $B{\perp}$ and the margin of contacts loss.

  • PDF

Luminance Control for a Given Gray Level by the Asymmetric Sustain Pulse Amplitude in AC PDP (주어진 계조 하에서 불평형 서스테인 펄스를 이용한 AC PDP의 휘도제어)

  • Lee Sun-Hong;Park Chung-Hoo;Choi Joon-Young
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.4
    • /
    • pp.161-165
    • /
    • 2005
  • Need of a dimmer function becomes more important with increasing interest on a HDTV for home theater applications. In a conventional AC PDP, a possible method to reduce luminance of a whole Panel is to reduce a total number of sustain pulses and then to change the gray level. However, the reduction of the total sustain number causes the step of luminance to be rough. Moreover, it is impossible to control the luminance of the panel for a given gray level. In this paper, a simple and robust method is proposed to control linearly the luminance of whole panel by applying the asymmetric sustain pulses in the display period of the ADS driving scheme. As the range of luminance control by the proposed method is about $50\%$ for a given gray level. Moreover, it is experimentally verified that the proposed method shows similar dynamic margin performances compare with the conventional method.

Images of Benign Vocal Fold Lesions Using Videokymogram

  • Ahn, Cheol-Min;Yoon, Seon-Young;Chung, Duk-Hee
    • Speech Sciences
    • /
    • v.7 no.1
    • /
    • pp.89-96
    • /
    • 2000
  • Examination of the vibrations of the vocal fold is very important in patients with voice changes. The newly developed videokymography (VKG) takes images in real time and records irregular vibrations of the vocal fold. However, there are few data on VKG findings. We studied VKG to evaluate the vibratory characteristics of the vocal fold in benign vocal fold lesions. Unique vibratory patterns, blurred demarcation of the mucosal propagation, decreased margin amplitudes, asymmetry in phase or amplitude, and a level difference of the contact site were observed in each benign vocal-fold lesion. We conclude that each type of laryngeal lesion has specific characteristic which are revealed by VKG examination, these parameters can be quantified and used to objectively evaluate VKG findings. Based on these results, VKG can be used as a supplementary diagnostic tool.

  • PDF

시일의 마멸로 인한 다단터빈펌프의 위험속도 변화

  • Kim, Yeong-Cheol;Lee, Dong-Hwan;Lee, Bong-Ju
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.02a
    • /
    • pp.203-209
    • /
    • 1998
  • Rotordynamic analysis of a multistage turbine pump using finite element method is performed to investigate the effects of seal wear on Its system behavior. Stiffness and damping coefficients of the 2-axial grooved bearing are obtained as functions of rotating speed. Stiffness and damping coefficients of plane annular seals are calculated as functions of rotating speed as well as seal clearance. As the clearance of seals become larger, these stiffness and damping coefficients decrease drastically so that there can be significant changes in whirl natural frequencies and damping characteristics of the pump rotor system. Although a pump is designed to operate with a sufficient seperation margin from the 1st critical speed, seal wear due to long operation may cause a sudden increase in nitration amplitude by resonance shift and reduce seal damping capability.

  • PDF

Impact of the Respiratory Motion and Longitudinal Profile on Helical Tomotherapy

  • Park, So Hyun;Choi, Jinhyun;Kim, JinSung;Ahn, Sohyun;Kim, Min Joo;Lee, Ho;Choi, Seo Hee;Park, Kwangwoo
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • The $TomoTherapy^{(R)}$ beam-delivery method creates helical beam-junctioning patterns in the dose distribution within the target. In addition, the dose discrepancy results in the particular region where the resonance by pattern of dose delivery occurs owing to the change in the position and shape of internal organs with a patient's respiration during long treatment times. In this study, we evaluated the dose pattern of the longitudinal profile with the change in respiration. The superior-inferior motion signal of the programmable respiratory motion phantom was obtained using AbChes as a four-dimensional computed tomography (4DCT) original moving signal. We delineated virtual targets in the phantom and planned to deliver the prescription dose of 300 cGy using field widths of 1.0 cm, 2.5 cm, and 5.0 cm. An original moving signal was fitted to reflecting the beam delivery time of the $TomoTherapy^{(R)}$. The EBT3 film was inserted into the phantom movement cassette, and static, without the movement and with the original movement, was measured with signal changes of 2.0 s, 4.0 s, and 5.0 s periods, and 2.0 mm and 4.0 mm amplitudes. It was found that a dose fluctuation within ${\pm}4.0%$ occurred in all longitudinal profiles. Compared with the original movement, the region of the gamma index above 1 partially appeared within the target and the border of the target when the period and amplitude were changed. Gamma passing rates were 95.00% or more. However, cases for a 5.0 s period and 4.0 mm amplitude at a field width of 2.5 cm and for 2.0 s and 5.0 s periods at a field width of 5.0 cm have gamma passing rates of 92.73%, 90.31%, 90.31%, and 93.60%. $TomoTherapy^{(R)}$ shows a small difference in dose distribution according to the changes of period and amplitude of respiration. Therefore, to treat a variable respiratory motion region, a margin reflecting the degree of change of respiration signal is required.

Performance A Analysis of OFDM/QPSK-DMR System Using BL-PSF over Microwave Channel Environments (Microwave 채널환경에서 BL-PSF를 적용하는 OFDM/QPSK-DMR 시스템의 성능분석)

  • Ahn, Jun-bae;Yang, Hee-jin;Oh, Chang-heon;Cho, Sung-joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9C
    • /
    • pp.1279-1288
    • /
    • 2004
  • In this paper, the DMR(Digital Microwave Radio) system-based OFDM(Orthogonal Frequency Division Multiplexing) scheme in microwave channel environments has been proposed and system performances have been evaluated. The existing single carrier DMR system has a complex system structure due to using high-level QAM(Quadrature Amplitude Modulation) modulation scheme and so charmel capacity is limited by sensitive effects from fading. Therefore, in the proposed DMR system, it uses that the OFDM scheme for enhancement of fading distortion and also uses that the band-limited pulse shaping filter instead of windowing for no additional data such as GI/GB and for using efficient of IFFT/FFT block. The performance of OFDM/QPSK-DMR system and single carrier DMR system are analysed by computer simulation using two-ray model under the microwave channel environments The computer simulation results confirm that the fade margin of the proposed OFDM/QPSK-DMR system is highly increased as the number of sub-carriers is larger.