• Title/Summary/Keyword: amplitude distortions

Search Result 34, Processing Time 0.027 seconds

A Digital Bathymetric Model combining Multi Beam Echo Sounder and Sidescan Sonar

  • Park, Jo-Seph;Kim, Hik-Il
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.330-330
    • /
    • 2002
  • The combination of Multi-Beam Echo Sounder swath bathymetry and high-resolution towed Sidescan sonar provides a powerful method of examination about hydrographic survey results. In this paper, we investigate the fast method of 3D bathymetric reconstruction with the Digital Sidescan sonar(Benthos SIS 1500) and Shallow Multi-Beam Echo Sounder(Reson Seabat 8125). The Seabat 8125 is a 455KHz high resolution focused Multibeam echo sounder(MBES) system which measures the relative water depth across a wide swath perpendicular to a vessel's track. The Benthos SIS1500 is a chirp(nominal fq. 200KHz) sonar which map the topographical features & sediment texture of ocean bottom using backscattered amplitude. We generates the very large 3D bathymetric texture mapping model with the Helical System's HHViewer and describes additional benefits of combining MBES and Sidescan Sonar imagery, the removal of geometric distortions in the model and a deterministic sounding noise.

  • PDF

Correction of MRI Artifact due to Planar Respiratory Motion (호흡운동에 의한 MRI 아티팩트의 수정)

  • 김응규;김규헌
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.1863-1866
    • /
    • 2003
  • In this study, respiratory motion is modeled by a 2-Dimensional linear expanding-shrinking movement. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimated, a reconstruction algorithm based on superposition method was used to removed the MRI artifact. For the purpose of estimating unknown motion parameters, we applied the spectrum shift method to find the respiratory fluctuation function, the x directional expansion coefficient and its center, and also we used the minimum energy method to find the y directional expansion coefficient and its center. The effectiveness of this presented method is shown by Computer simulations.

  • PDF

A Compensation of Linear Distortion for Loudspeaker Using the Adaptive Digital Filter (적응 디지탈 필터를 이용한 확성용 스피커의 선형 왜곡 보상)

  • 전희영;차일환
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1995.06a
    • /
    • pp.165-170
    • /
    • 1995
  • In this paper, it is attempted to apply the adaptive digital signal processing to compensate for a linear distortion of a loudspeaker and implement a real time hardware for that purpose. The real time system is implemented by using the DSP56001, a general purpose signal processor, as a host processor and the DSP56200, a cascadable adaptive FIR filter peripheral chip, as an adaptive digital filter. The system has 1000 taps at a 44.1kHz. After inverse modeling of under_compensation_speaker, the system reduces loudspeaker's linear distortions by pre-processing an input audio signal to loudspeaker. The experiment shows satisfactory results; after adaption with white noise as input signal for 60sec, the flat amplitude and linear phase frequency characteristics is found to lie over a wide frequency range of 100Hz to 20kHz.

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance

  • Han, Daesu;Park, Yonggyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.246-247
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. Combination of these two control algorithms depending on the operating requirements and depth of grid unbalance presents most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system. The proposed control algorithms are verified through transient response in the simulation.

  • PDF

A Design of Predistorter for Independently Controllable AM/AM and AM/PM of High Power Amplifier for the Communication Systems (통신용 대전력증폭기의 AM/AM과 AM/PM을 독립적으로 제어하는 전치왜곡보상기 설계)

  • 원용규;정찬수
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.3
    • /
    • pp.188-196
    • /
    • 2004
  • Amplifier linearity plays a major role in the quality of mordern communication systems. The Power amplifier should be operated near saturation region to achieve high efficiency But at this region amplitude and phase distortions of the amplifier remarkably increase with the input power increase and cause a significant adjacent channel interference. In this paper, an independently controllable AM/AM and AM/PM predistortion linearizers consisted of two bias feed resistance linearizers is proposed. This linearizer allows independent adjustment of the AM/AM and AM/PM curves by using two adjustable voltages to compensate tile power amplifier non-linearities. The predistortion linearizer can improve the ACPR by 5.3dB with cdma2000 multi carrier signals. And by applying this linearizer to two-tone(880MHz) power amplifier, third order IMD products are improved up to 8(dB).

MRI Artifact Correction due to Respiratory Motion (호흡운동에 따른 MRI 아티팩트 수정)

  • 김응규;김규헌
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.58-61
    • /
    • 2003
  • In this study, a planar respiratory motion is modeled by a 2-D linear expanding-shrinking movement. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimated, a construction algorithm based on superposition method was used to remove the MRI artifact. For the purpose of estimating unknown motion parameters, we used the spectrum shift method to find the respiratory fluctuation function, the x directional expansion coefficient and its center, and we also used the minimum energy method to find the y directional expansion coefficient and its center. Finally the effectiveness of this presented method is shown by computer simulations.

  • PDF

Visualization Tool of Distortion-Free Time-Series Matching (왜곡 제거 시계열 매칭의 시각화 도구)

  • Moon, Seongwoo;Lee, Sanghun;Kim, Bum-Soo;Moon, Yang-Sae
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.9
    • /
    • pp.377-384
    • /
    • 2015
  • In this paper we propose a visualization tool for distortion-free time-series matching. Supporting distortion-free is a very important factor in time-series matching to get more accurate matching results. In this paper, we visualize the result of time-series matching, which removes various time-series distortions such as noise, offset translation, amplitude scaling, and linear trend by using moving average, normalization, linear detrending transformations, respectively. The proposed visualization tool works as a client-server model. The client sends a user-selected time-series, of which distortions are removed, to the server and visualizes the matching results. The server efficiently performs the distortion-free time-series matching on the multi-dimensional R*-tree index. By visualizing the matching result as five different charts, we can more easily and more intuitively understand the matching result.

Blind Equalizer and Carrier Recovery Circuit Using $\theta$-matching Algorithm in QAM Signal Demodulator (QAM 신호 복조시 자력 등화기와 $\theta$-정합을 이용한 위상 복구 회로)

  • 조웅기;장일순;정차근;조경록
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6A
    • /
    • pp.920-930
    • /
    • 1999
  • Many researches on the multi-level QAM(Quadrature Amplitude Modulation) which is known to be a promising digital data transmission method for efficient use of channel bandwidth have been carried on, and their applications to various real fields are now being in progress. However, in the band-limited communication systems, each transmitted symbols is distorted by the ISI(Intersymbol Interference) and the phase error. Therefore, an equalizer and a carrier recovery must be taken into considerations to attenuate the effects of these distortions in the receiver. This paper presents an effective receiver structures that is applicable to the multi-level QAM. The proposed receiver system is consisted of an equalizer with Godard’s blind algorithm and a carrier recovery circuit. The phase error is estimated with a $\theta$-matching algorithm and is used in the carrier recovery to recover the correct phase. The simulation results are included to evaluate performance of the proposed receiver system for the various channel models.

  • PDF

Performance of 8SQAM System in a Nonlinearly Amplified Channel Environment (비선형 증폭 채널 환경에서 8SQAM 시스템의 성능)

  • 성봉훈;서종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.7C
    • /
    • pp.669-677
    • /
    • 2003
  • A new Modem technique - 8SQAM(8-state Superposed Quadrature Amplitude Modulation) - for use in power and bandwidth limited digital communication system is proposed. 8SQAM is free of inter-symbol interference(ISI) and generates output signals which have a smooth and continuous phase transition and a reduced envelope fluctuation by keeping correlation between amplitudes and phases of two subsequent symbols. Accordingly, 8SQAM, as compared with a conventional 8PSK, is influenced a little by ISI and inter-modulation(IM) caused by nonlinear distortions. In this paper, the performance of the 8SQAM system, in a nonlinearly amplified channel impaired by additive white Gaussian noise(AWGN), ISI and IM, is analyzed via computer simulation. The simulation result shows that 8SQAM outperforms 8PSK with roll-off value of $\alpha$=0.25 by 2.5dB in CNR to maintain BER=1$\times$10$^{-4}$ when input back-off(IBO) of HPA is 3dB.

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.