• Title/Summary/Keyword: amplitude difference

Search Result 654, Processing Time 0.037 seconds

Comparison of Intraoperative Somatosensory Evoked Potential(SSEP) Monitoring During Aneurysm Surgery : ACA Aneurysms vs MCA Aneurysms (전대뇌동맥과 중대뇌동맥 동맥류 수술시 체성감각유발전위의 모니터링의 비교, 분석)

  • Choi, Kwang Yeong;Kim, Gook Ki;Lim, Young Jin;Kim, Tae Sung;Leem, Won;Rhee, Bong Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.281-288
    • /
    • 2001
  • Objectives : The purpose of this study is to evaluate the usefulness of SSEP monitoring during intracranial aneurysm surgery and compare the characteristics of wave change in relation to neurologic changes between ACA aneurysms and MCA aneurysms. Methods : During recent three years(between January 1997 and November 1999), intraoperative SSEP monitoring had been done in 63 operations for intracranial aneurysms. We had monitored the median nerve SSEP during surgery for aneurysms of MCA and the posterior tibial nerve SSEP for aneurysms of ACoA or ACA. A more than 50% reduction of any cortical SEP response was considered to be a significant SEP change, compared to its baseline value before the start of surgery. Changes in the SEPs were categorized as follows : Type IA, no significant amplitude changes without temporary clipping ; Type IB, no significant amplitude changes with temporary clipping ; Type II, significant changes with temporary clipping and complete return to control amplitude ; Type III, significant changes with temporary clipping and incomplete return to control amplitude ; Type IV, significant changes with temporary clipping and more decreased amplitude changes. Results : Among the 63 intraoperative monitoring, there were 37 cases of ACA aneurysms(An), and 26 of MCA An. The temporary proximal arterial occlusion during surgery were performed in 31(83.8%)cases of ACA An, 22(84.6%) of MCA An. Seven of the 31 ACA An(22.6%) and ten of the 22 MCA An(45.5%) had significant changes. The type were as follows : 4 patients with type II and 3 with type III in the ACA An ; 3 patients with type II and 3 with type III and 4 with type IV in the MCA An. In both group type II changes had no new postoperative neurological deficit. All 6 patients with type III had new neurological deficits ; However, One case in the ACA An and two cases in the MCA An. had transient neurologic deficit and improved markedly over the next two months. All 4 type IV changes in the MCA An. had permanant neurologic deficits. Two out of 30 cases(6.7%) in the ACA An. and one out of 16 cases(6.3%) in the MCA An. without significant amplitude change had new neurologic deficit postoperatively. Conclusion : Based on this study, Intraoperative SSEP monitoring during aneurysm surgery would provide useful information for detecting cerebral ischemia. SSEP response during surgery for MCA An. is more sensitive than ACA An. Otherwise, there were no meaningful difference in rate of false negativity.

  • PDF

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

The effects of the methods of eye gaze and visual angles on accuracy of P300 speller (시선응시 방법과 시각도가 P300 문자입력기의 정확도에 미치는 영향)

  • Eom, Jin-Sup;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.17 no.2
    • /
    • pp.91-100
    • /
    • 2014
  • This study was to examine how visual angle of matrix corresponding to the physical properties of P300 speller and eye gaze corresponding to the user's personal characteristics influence on the accuracy of P300. Visual angle of the matrix was operated as the distance between the user and the matrix and three groups were composed: 60 cm group, 100 cm groups, and 150 cm group. Eye gaze methods was consisted three conditions. Head moving condition was putting eye gaze using head, pupil moving condition was moving pupil with the head fixed, while the eye fixed condition is to fix the eye gaze at the center of the matrix. The results showed that there was significant difference in the accuracy of P300 speller according to the eye gaze method. The accuracy of the head moving condition was higher than the accuracy of pupil moving conditions, accuracy of pupil moving conditions was higher than the accuracy of the eye fixed conditions. However, the effect of visual angle of matrix and interaction effect were not significant. When P300 amplitude of target character was measured depending on how you stare at the target character, P300 amplitude of the head moving condition was greater than P300 amplitude of the pupil moving condition. There was no significant difference in the error distribution in head moving condition and pupil moving condition, while there was a significant difference between two eye gaze conditions and fixed gaze condition. The error was located at the neighboring characters of the target character in head moving condition and pupil moving condition, while the error was relatively distributed widely in fixed eye condition, error was occurred with high rate in characters far away from the center of matrix.

Vortex Pairing and Jet-Spreading in an Axisymmetric Jet under Helical Fundamental and Axisymmetric Subharmonic Forcing (헬리컬 기본교란과 축대칭 분수조화교란을 이용한 원형제트에서의 보텍스 병합 및 제트확산)

  • Cho, Sung Kwon;Yoo, Jung Yul;Choi, Haecheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1610-1624
    • /
    • 1998
  • An axisymmetric jet is forced with two helical fundamental waves of identical frequency spinning in opposite directions and an additional axisymmetric sub harmonic wave. The subharmonic component rapidly grows downstream from subharmonic resonance with the fundamental, significantly depending on the initial phase difference. The variations of the subharmonic amplitude with the initial phase difference show cusp-like shapes. The amplification of the sub harmonic results in 'vortex pairing of helical modes'. Furthermore, azimuthal variation of the amplification induces an asymmetric jet cross-section. When the initial subharmonics is imposed with an initial phase difference close to a critical value, the jet-cross section evolves into a three-lobed shape. One lobe is generated by the enhanced vortex pairing and the other two lobes are generated by the delayed vortex pairing. Thus, it is confirmed that the initial phase difference between the fundamental and the subharmonic plays an important role in controlling the jet cross-section.

The Effect of Joint Space Pumping Treatment in Patients with Reducible Disc Displacement Accompanied by TMJ Sound and Pain (악관절잡음 및 동통을 동반한 정복성 관절원판 변위환자에 대한 관절강 Pumping 효과)

  • Kim, Hyeon-Cheol;Choi, Jong-Hoon;Park, Hye-Suk;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.1
    • /
    • pp.9-24
    • /
    • 1999
  • Pumping into the upper joint cavity of the TMJ was done on patients who had reducible disc displacement with pain. This article discusses the change in TMJ sounds before and after the Pumping treatment. 20subjects(mean age of $32.1{\pm}10.2yr$)were selected among those who visited the department of Oral Medicine of Yonsei University for the treatment of craniomandibular dysfunctions. Through a thorough history taking, clinical exam and X-ray taking these subjects were diagnosed as reducible disc displacement patients, and they were subdivided into two groups as acute and chronic according to the time the TMJ sound was made. Sonopak was used to measure the TMJ sound before, right after and one-week after the Pumping treatment. VAS was used to measure the degree of subjective TMJ complaints(sounds and pain) before and one-week after the Pumping treatment. Vibration related items included total integral, high integral, low integral, ratio of high integral to low integral, peak amplitude, peak frequency and median frquency. 1. It was not statistically significant between the acute and chronic groups before the treatment. However, total integral, high integral, low integral, peak amplitude, peak frequency, median frequency showed to be greater in the chronic group. 2. In all the subjects, just after the Pumping treatment was done, total integral, high and low integral, peak amplitude and peak frequency significantly decreased (p<0.05). Even after one week, low integral, peak frequency and median frequency significantly decreased (p<0,05), and the TMJ sound diminished accordingly. 3. Comparing the two groups(before and right after the Pumping treatment), there was the following difference ; in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05). In the chronic group, total integral, high integral, low integral, ratio, peak amplitude and peak frequency significantly decreased(p<0,05). It was not statistically significant between the acute and chronic group. 4. Comparing the two groups(right after and one week after the Pumping treatment), there was the following difference : in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05), In the chronic group, low integral significantly decreased(p<0.05). However, although it was not statistically significant, after one week, there was an increase in total integral, ratio, peak amplitude and peak frequency compared to right after the treatment group. 5. In the VAS of before and one week after the Pumping treatment of the TMJ pain and sound, the TMJ pain significantly decreased(p<0.05) in both the acute and chronic group. However, it was not statistically significant between the two groups. There was a statistically significant decrease(p<0.05) in the TMJ sound in the acute group after one week of Pumping treatment, but no change was notable in the chronic group and it was not statistically significant between the two groups. From the above results, we can conclude that Pumping into the upper joint cavity of patients having reducible disc displacement is effective in reducing clicking and pain. Therefore, it can be applied in diverse clinical fields.

  • PDF

A Study on the Frequency Response Characteristics of High Response Flow Control Servo Valve (고 응답 유량제어 서보밸브의 주파수 응답특성에 관한 연구)

  • 서종수;신유식;지명국;전영흥;정효민;정한식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.480-488
    • /
    • 2003
  • The purpose of this research Is to derive the principal design parameters governing the dynamic characteristics of the high response flow control servo valve. For this purpose, a numerical modeling of the servo valve system and a parameter sensitivity analysis to a frequency response characteristics was peformed. As a result of these analysis, a basis for improvement of a dynamic characteristics of servo valve was arranged.

A Comparison Study Between Navier-Stokes Equation and Reynolds Equation in Lubricating Flow Regime

  • Song, Dong-Joo;Seo, Duck-Kyo;William W. Schultz
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.599-605
    • /
    • 2003
  • For practical calculations, the Reynolds equation is frequently used to analyze the lubricating flow. The full Navier-Stokes Equations are used to find validity limits of Reynolds equation in a lubricating flow regime by result comparison. As the amplitude of wavy upper wall increased at a given average channel height, the difference between Navier-Stokes and lubrication theory decreased slightly : however, as the minimum distance in channel throat increased, the differences in the maximum pressure between Navier-Stokes and lubrication theory became large.

Space Voltage Vector Pulse Width Modulation for 2-Phase Inverter (2상 인버터를 위한 공간 전압벡터 방식)

  • 장도현;박재권
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.280-286
    • /
    • 1998
  • In this paper, space voltage vector pulsewidth modulation for 2-phase inverter is proposed. When this method is appled to 2-phase induction motor, the phase difference of voltage between phase A and B is fixed at $90^{\circ}$and amplitude of voltage of phase Ais same with that of phase B. This method have advantages over low-power servo system because this is simple method comparing to 3-phase space vector method which requires d-q transform.

  • PDF

Effect of Physical Training on Electrocardiographic Amplitudes and the QRS Vector (체력단련(體力鍛練)이 심전도파고(心電圖波高)와 QRS벡타에 미치는 효과(效果))

  • Yu, Wan-Sik;Hwang, Soo-Kwan;Kim, Hyeong-Jin;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.18 no.1
    • /
    • pp.51-65
    • /
    • 1984
  • In an effort to elucidate the effect of physical training on the electrocardiographic amplitudes, QRS vector, axis and QRS vector amplitude, electrocardiograms were recorded before and 1, 5 and 10 minutes after 3 minute rebounder exercise in 23 healthy male students aged between 18 and 21 years in two groups of athletes and non-athletes. ECG amplitudes were measured from lead I, $V_1$ and $V_5$ and axis and amplitudes of QRS vectors were measured from lead I and III in frontal plane, from lead $V_2$ and lead $V_6$ in horizontal plane. The results obtained are summarized as follows. ECG amplitudes: The R wave amplitude was $23.38{\pm}1.14\;mm$ in athletes which was higher than $17.91{\pm}2.00\;mm$ in non-athletes. After exercise, the difference in two groups remained significant throughout the recovery period. The S wave amplitude was increased significantly, and the T wave amplitude was decreased in both groups after exercise. The P wave amplitude was increased in both groups after exercise, and it was lower in athletes than in non-athletes. The PQ segment amplitude was zero in athletes but negative in non-athletes than in the resting state. The J point amplitude was positive in resting state and was negative after exercise in both groups. J+0.08 sec point amplitude was also lowered after exercise, and it was higher in athletes than in non-athletes. Therefore the whole ST segment was proved to be decreased after exercise. The summated amplitude of R in $V_5$ plus S in $V_1$ was $38.74{\pm}2.71\;mm$ in athletes which was higher than $32.82{\pm}2.90\;mm$ in non-athletes. After exercise, it was also significantly higher in athletes than in non-athletes. Axis of QRS vector: In frontal plane, axis of QRS vector was $62.7{\pm}7.36^{\circ}$ in athletes, it showed no significant difference between the two groups. In horizontal plane, axis of QRS vector was $-23.5{\pm}7.2^{\circ}$ in athletes which was significantly higher than $-38.8{\pm}8.2^{\circ}$ in non-athletes. After exercise, it was significantly higher than the resting state in both groups. Amplitude of QRS vector : In frontal plane, amplitude of QRS vector was $13.86{\pm}1.44\;mm$ in athletes which was significantly higher than $9.62{\pm}0.97\;mm$ in non-athletes. After exercise, it was also significantly higher in athletes than in non-athletes. In horizontal plane, amplitude of QRS vector was $19.82{\pm}2.10\;mm$ in athletes which was significantly higher than $16.90{\pm}1.39\;mm$ in non-athletes. After exercise, it was also significantly higher in athletes than in non-athletes. From the above, these results indicate that R wave amplitude in athletes was significantly higher than in non-athletes before and after exercise, and that the summated amplitude of R in $V_5$ plus S in $V_1$ in athletes was also $38.74{\pm}2.71\;mm$ suggesting a left ventricular hypertrophy We should note that the PQ segment and ST segment amplitude were higher in athletes than in non-athletes, and they were decreased with exercise in both groups. In particular, the fact that amplitudes of QRS vector in frontal plane or in horizontal plane were significantly greater in athletes than in non-athletes may be an index in evaluating athletes.

  • PDF

Nonlinear Sound Amplification and Directivity Due to Underwater Bubbles (수중 기포에 의한 비선형 음파의 증폭과 지향성)

  • 김병남;최복경;윤석왕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.250-260
    • /
    • 2003
  • Since a bubble in water is a highly nonlinear acoustic scatterer, the acoustic scattered waves from underwater bubbles show highly nonlinear acoustic properties. These acoustic scattered waves can be observed at the second or higher harmonics as well as at the fundamental primary frequency of incident acoustic wave. When two primary acoustic waves of different frequencies are incident on a bubble, the acoustic scattered waves can be also observed at the sum and the difference frequencies of the primary waves. In this study, when the two primary acoustic waves were incident on a bubble screen in water, we observed that the amplitude of difference frequency wave was amplified by the bubble nonlinearity and its directivity was oriented in the propagation directions of primary waves. The directivity of scattered difference frequency wave was analyzed as a coherent scattering for virtual source by using the directivity of the primary acoustic wave.