• 제목/요약/키워드: alternating conductivity

검색결과 30건 처리시간 0.021초

Effect of open-core screw dislocation on axial conductivity in semiconductor crystals

  • Taira, Hisao;Sato, Motohiro
    • Advances in nano research
    • /
    • 제1권3호
    • /
    • pp.171-182
    • /
    • 2013
  • The alternating current (AC) conductivity in semiconductor crystals with an open-core screw dislocation is studied in the current work. The screw dislocation in crystalline media results in an effective potential field which affects the electronic transport properties of the system. Therefore, from a technological view point, it is interesting to investigate properties of AC conductivity at frequencies of a few terahertz. To quantify the screw-induced potential effect, we calculated the AC conductivity of dislocated crystals using the Kubo formula. The conductivity showed peaks within the terahertz frequency region, where the amplitude of the AC conductivity was large enough to be measured in experiments. The measurable conductivity peaks did not arise in dislocation-free crystals threaded by a magnetic flux tube. These results imply different conductivity mechanisms in crystals with a screw dislocation than those threaded by a magnetic flux tube, despite the apparent similarity in their electronic eigenstates.

Effects of Alternating Magnetic Field Assisted Annealing of Pentacene Film for Organic Thin Film Transistor Applications

  • Park, Jae-Hoon;Choi, Jong-Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권1호
    • /
    • pp.32-35
    • /
    • 2007
  • In this article, a novel annealing technique using alternating magnetic field (AMF) is adopted to improve the electrical characteristics of pentacene film, thereby enhancing the performance of pentacene-based organic thin film transistors (OTFTs). According to the investigation results, the electrical conductivity in the pentacene film could be increased from 0.32 to 1.18 S/cm by annealing the pentacene film using AMF. And also, OTFTs with the pentacene film annealed by AMF exhibited an improved performance compared to the device without annealing. These results suggest that an annealing using AMF can be an effective method to improve the performance of devices based on organic semiconductors.

MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHY

  • Kwon, Oh-In;Seo, Jin-Keun;Woo, Eung-Je;Yoon, Jeong-Rock
    • 대한수학회논문집
    • /
    • 제16권3호
    • /
    • pp.519-541
    • /
    • 2001
  • Magnetic Resonance Electrical Impedance Tomography(MREIT) is a new medical imaging technique for the cross-sectional conductivity distribution of a human body using both EIT(Electrical Impedance Tomography) and MRI(Magnetic Resonance Imaging) system. MREIT system was designed to enhance EIT imaging system which has inherent low sensitivity of boundary measurements to any changes of internal tissue conductivity values. MREIT utilizes a recent CDI (Current Density Imaging) technique of measuring the internal current density by means of MRI technique. In this paper, a mathematical modeling for MREIT and image reconstruction method called the alternating J-substitution algorithm are presented. Computer simulations show that the alternating J-substitution algorithm provides accurate high-resolution conductivity images.

  • PDF

Evaluation of 475 ℃ embrittlement in UNS S32750 super duplex stainless steel using four-point electric conductivity measurements

  • Gutierrez-Vargas, Gildardo;Ruiz, Alberto;Lopez-Morelos, Victor H.;Kim, Jin-Yeon;Gonzalez-Sanchez, Jorge;Medina-Flores, Ariosto
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.2982-2989
    • /
    • 2021
  • One of the consequences of the 475 ℃ embrittlement of duplex stainless steels is the reduction of the resistance to localized corrosion. Therefore, the detection of this type of embrittlement before the material exhibits significant loss in toughness, and corrosion resistance is important to ensure the structural integrity of critical components under corrosion threats. In this research, conductivity measurements are performed using the alternating current potential drop (ACPD) technique with using a portable four-point probe as a nondestructive evaluation (NDE) method for detecting the embrittlement in a 2507 (UNS S32750) super duplex stainless steel (SDSS) aged at 475 ℃ from as-received condition to 300 h. The electric conductivity results were compared against two electrochemical tests namely double loop electrochemical potentiokinetic reactivation (DL-EPR) and critical pitting temperature (CPT). Mechanical tests and the microstructure characterized using scanning electron microscopy (SEM) imaging are conducted to track the progress of embrittlement. It is shown that the electric conductivity correlates with the changes in impact energy, microhardness, and CPT corrosion tests result demonstrating the feasibility of the four-point probe as a possible field-deployable method for evaluating the 475 ℃ embrittlement of 2507 SDSS.

DyCoO3 세라믹스의 교류전도특성 (Alternating-Current Electrical Conduction Properties of DyCoO3 Ceramics)

  • 정우환
    • 한국재료학회지
    • /
    • 제20권3호
    • /
    • pp.161-166
    • /
    • 2010
  • The ac, dc conductivity and dielectric properties of $DyCoO_3$ were reported in the temperature range of 77 - 300K and in the frequency range of 20 Hz - 100 kHz. It was observed that at low temperature, ac conductivity is much higher than dc conductivity and the hopping carrier between localized states near the Fermi level was the dominant loss mechanism. A comparison of the measured ac conductivity $\sigma(\omega)$ was made with some of the models of hopping conductivity of the proposed earlier in the literature. It was observed that in $DyCoO_3$ the measured ac conductivity, over the entire frequency and temperature region, can be explained reasonably well by assuming two contributions $\sigma_1(\omega)$ and $\sigma_2(\omega)$ to the measured $\sigma(\omega)$. The first, $\sigma_1(\omega)$, which dominates at low temperature, may be due to impurity conduction in a small polaron; the second, $\sigma_2(\omega)$, which dominates at higher temperatures, depending on the frequency of measurements, may be due to the hopping of a small polaron and is reasonable for the dielectric relaxation peak.

Investigations of Temperature Effect on the Conduction Mechanism of Electrical Conductivity of Copolymer/Carbon Black Composite

  • El Hasnaoui, M.;Kreit, L.;Costa, L.C.;Achour, M.E.
    • Applied Microscopy
    • /
    • 제47권3호
    • /
    • pp.121-125
    • /
    • 2017
  • This study deals the prediction of temperature effect on low-frequency dispersion of alternating current (AC) conductivity spectra of composite materials based on copolymer reinforced with carbon black (CB) particles. A sample of ethylene butylacrylate loaded with 13% of CB particles were prepared and investigated using the impedance spectroscopy representation in the frequency range from 40 Hz to 0.1 MHz and temperature range from $20^{\circ}C$ to $125^{\circ}C$. The dielectric constant, ${\varepsilon}^{\prime}$, and dielectric losses, ${\varepsilon}^{{\prime}{\prime}}$, were found to decrease with increasing frequency. The frequency dependence of the AC conductivity follows the universal power law with a large deviation in the high frequency region, the positive temperature coefficient in resistivity effect has been observed below the melting temperature which makes this composite potentially remarkable for industrial applications.

CONDUCTIVITIES OF SEA-BOTTOM SEDIMENTS

  • HoWoongShon
    • 지구물리
    • /
    • 제6권2호
    • /
    • pp.79-87
    • /
    • 2003
  • An in-situ four-electrode contact resistivity probe system was designed, and field-tested in submarine sediments. Seismic survey was also performed to support and compare the results of electric survey. The probe was designed to be driven to selected depths below the seafloor using a Vibracore system. The four insulated electrodes were, spaced equidistant across the wedge, were extended beyond the probe tip to minimize effects of sediment disturbance by the wedge insertion. In-situ measurements of resistivity were recorded on board by precision electronic equipment consisting of signal generators and processors, and by temperature- monitoring systems. Overall limits of uncertainty at respective depths below the seafloor are up to ±10% of the measured values. Best estimates of conductivity are considered to be ±3 percent of the reported values. Resistivity measurements were made at six sites in carbonate sediments to a maximum depth of penetration of about 5 m. Average values of conductivity range between 0.88 and 1.21 mho/m. The results show the seabed is composed of alternating layers of relatively high-conductivity material (0.8 to 1.4 mho/m) in thicknesses of more or less one meter and layers about 30 cm thick having relatively low conductivities (0.4 to 0.8 mho/m).

  • PDF

균열을 가진 상자성체의 교류전위차에 미치는 하중의 영향 (Loading Effect on ACPD of a Crack in Paramagnetic Material)

  • 이정희
    • 비파괴검사학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 1999
  • 교류전위차법 (alternating current potential drop : ACPD)을 이용하여 이차원 표면균열을 갖고 있는 상자성체 (paramagnetic material)의 모드 I (opening mode) 응력확대계수($K_I$)를 실험적으로 평가하기 위하여 하중에 따른 교류전위차 변화(change in ACPD)를 연구하였다. 아울러 하중에 의한 전위차 변화의 원인 그리고 전위차 변화에 미치는 자속(magnetic flux) 탈자(demagnetization) 및 균열길이의 영향을 연구하였다. 상자성체의 교류전위차는 인장하중을 증가시킬수록 선형적으로 감소하였다. 전위차 감소의 원인은 균열선단 주위의 도전율(conductivity)이 인장하중의 증가에 따라 증가하고 이는 시험편의 저항과 내부 인덕턴스를 감소시키기 때문이다. 도전율의 변화는 균열선단 주변의 응력상태에 의존하기 때문에 일정 $K_I$ 변화에 따른 전위차 변화량은 균열길이에 의존하지 않는다. 하중에 의한 전위차변화량은 시험편 주위의 자속의 유무에 영향을 받지만 탈자의 유무에는 영향을 받지 않는다.

  • PDF

신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현 (Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis)

  • 김성철;조병남;이석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.331-333
    • /
    • 2004
  • In this study, we implement the multiple frequency bioelectrical impedance analysis system for body composition analysis. Overall system consists of : 1) conductivity electrodes to contact with hands and foots, 2) multiple frequency alternating current signal generator for generating 5, 50, 250kHz frequency and 800uA contained alternating current signal, 3) voltage signal detector, 4) phase signal detector, 5) key-pad to input individual information, 6) micro controller for data processing, 7) LCD for processed data to display, 8) system power, We explain the architecture of the system and required theory to implement the system. Finally, experimental results are illustrated to show the performance of the system.

  • PDF

교번자속 인가에 의한 유기 반도체막의 어닐링 효과에 관한 연구 (Study on the annealing effects of organic semiconductiong layer using alternating magnetic field)

  • 박재훈;최종선;이용수;노재상;김은석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1517-1519
    • /
    • 2003
  • A novel technique of alternating magnetic field (AMF) is investigated to improve the electrical conducting properties of pentacene. By applying AMF to pentacene layer, the electrical conductivity of pentacene was enhanced, which can be applied for characteristic improvements of pentacene-based thin-film transistors. In this study, the annealing effects of pentacene layer using AMF will be discussed.

  • PDF