• Title/Summary/Keyword: alkali ion

Search Result 279, Processing Time 0.028 seconds

A Review on the Analytical Techniques for the Determination of Fluorine Contents in Soil and Solid Phase Samples (토양 및 고체시료 중 불소함량 측정기법)

  • An, Jinsung;Kim, Joo-Ae;Yoon, Hye-On
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.112-122
    • /
    • 2013
  • Current status of soil contamination with fluorine and its source were investigated. The basic principles and procedures of various techniques for the analysis of fluorine contents in soil and solid phase samples were summarized in this review. Analysis of fluorine in solid matrices can be achieved by two types of techniques: (i) UV/Vis spectrophotometer or ion selective electrode (ISE) analysis after performing appropriate extraction steps and (ii) direct solid analysis. As the former cases, the standard method of Korean ministry of environment, alkali fusion-ISE method, pyrohydrolysis, oxygen bomb combustion, aqua regia digestion-automatic analysis, and sequential extraction-ISE method were introduced. In addition, direct analysis methods (i.e., X-ray fluorescence spectrometry and proton induced gamma-ray emission spectrometry) and atomic spectrometry combining with the equipment for introducing solid phase sample were also reviewed. Fluorine analysis techniques can be reasonably selected through site-specific information such as matrix condition, contamination level, the amount of samples and the principles of various methods for the analysis of fluorine presented in this review.

Determination of Trace Strontium with o-Cresolphthaleoxon by Electroanalytical method (o-Cresolphthaleoxon을 이용한 스트론튬의 전기화학적 분석)

  • Choi, Won Hyung;Lee, Jin Sik;Kim, Do Hoon;Kim, Jae Soo
    • Analytical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.247-254
    • /
    • 1993
  • Strontium can not be determined by conventional dc polarography method since it is very difficult to be reduced at the drop mercury electrode(DME) in aqueous solution. However the analytical sensitivity was improved by adsorptive stripping voltammetry in which electro-reduction of ligand in a complex formed between strontium and o-cresolphthaleoxone was performed. Strontium could be determined in range of $5{\sim}30{\mu}g/L$ concentration. This method was affected by coexistent alkali earth metal ions. Consequently ion exchange separation is recommended to analyze strontium in samples.

  • PDF

Lithium Ion Selective Electrode Based on a Synthetic Neutural Carrier (중성운반체를 이용한 리튬이온 선택 전극)

  • Kim, Jae Sang
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.33-39
    • /
    • 1992
  • THF-based crown-4 of 16-membered rings having tetrahydrofuran unit was synthesized by an acid-catalyzed condensation of furan and acetone followed by hydrogenation in an effort to obtain highly elective ionophores for lithium ions. The new ionophore was compared with previously reported ionophores under similar measurement conditions with the same plasticizer, tris(2-ethylhexyl) phosphate in poly(vinyl chloride)(PVC) membrane electrodes. Separate solution method was used to determine relative selectivity coefficients for the electrode. The selectivity coefficients($K_{LiM}^{POT}$) of lithium over ammonium, alkali and alkaline earth metal ions go from about $2.4{\times}10^{-1}$ to $2.3{\times}10^{-4}$ to working range and pH dependence have also been studied.

  • PDF

A Study on Heavy Metal Removal Using Alginic Acid (알긴산을 이용한 중금속 제거에 관한 연구)

  • Jeon, Choong;Choi, Suk Soon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.4
    • /
    • pp.107-114
    • /
    • 2007
  • A study on the removal of heavy metals using alginic acid, a kind of polysaccharides, was performed. Alginic acid adsorbed 480 mg Pb/g dry mass at pH 4, which was about twice as high as uptake capacity of other biosorbents. Isothermal adsorption curve for lead ions was described by the Langmuir model equation and the experimental data well fitted to model equation. The adsorption of lead ions was an endothermic process since binding strength increased with temperature. The effect of alkali metal ions ($Ca^{2+}$ and $Mg^{2+}$) on lead sorption capacity was negligible and most adsorption process was completed in 30min. The uptake capacity of other metals such as, copper, mercury, strontium, and cesium ions using alginic acid was also investigated.

  • PDF

Status and Prospect of Test Methods of Quality Silicone Water Repellent for Protecting Reinforced Concrete

  • Sun, H.Y.;Yuan, Z.Y.;Yang, Z.;Shan, G.L.;Shen, M.X.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • Impregnating with quality silicone water repellent on the concrete surface is an effective method of protecting concrete. Quality silicone water repellent has been widely used in the engineering profession because of its desirable properties such as hydrophobicity, keeping concrete breathable and preserving the original appearance of the concrete. The companies in China that produce silicone water repellent are listed. Test methods in the specifications or standards about silicone water repellent in China are summed. The test methods relative to durability of concrete impregnated with silicone water repellent (such as resistant to chloride ion penetration, resistant to alkali, resistance to freezing and thawing and weatherability etc.) and the constructive quality (such as water absorption rate, impregnating depth and the dry velocity coefficient etc.) are compared and analyzed. The results indicate that there are differences among test methods relative to different specifications with the same index and therefore, confusion has ensued when selecting test methods. All test methods with the exception of the method of water absorption rate by using a Karsten flask are not non-destructive methods or conducted in a laboratory. Finally, further research on silicone water repellent during application is proposed.

Removal of Ni and Pb Ion from Aqueous Solution by the Agricultural Wastes, Allium Roots (농산 폐기물인 Allium속 뿌리를 이용한 Ni와 Pb 이온 제거)

  • 김성호;백승화;김운성;문광현
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.6
    • /
    • pp.595-599
    • /
    • 1998
  • A batch experiment was conducted to evaluate the removal capacity of welsh onion(Allium fistulosum L.), shallot (Allium ascalonicum L.), garlic (Allium sativum L.) roots as an adsorbent for Ni and Pb in aqueous solution. One gram of the dried Allium root powder was reacted in 100ml of solution containing 10mg of each heavy metal and effects of metal concentration, pH, temperature, and size of adsorbent on the removal efficiency were evaluated. The results were as follows ; The amount of adsorption of heavy metal ions were higher with the smaller particles size of adsorbent. Garlic root was high adsorption capacity of Pb, especially. The higher concentration of heavy metal solution was, the more amount of adsorption of heavy metals was. The adsorption ratio was differed from a kind of heavy metal. As the temperature increased, the amount of adsorption of Ni and Pb by shallot and welsh onion were decreased. The amount of adsorption of Ni was high under alkali conditions but the amount of adsorption of Pb was high under neutral and acidity condition.

  • PDF

Dyeing Properties of Natural Red Colorants Extracted from Phytolacca americana Linne against Wool Fabrics (미국자리공으로부터 추출한 홍색색소의 모섬유에 대한 염색성)

  • 홍경옥;오태광;배순이;신인수
    • Textile Coloration and Finishing
    • /
    • v.11 no.2
    • /
    • pp.38-45
    • /
    • 1999
  • Natural red colorants were extracted from Phytolacca americana Linne by using 50% ethanol solution at room temperature for 12 hours. The colorant components were partially purified as yellow and deep red colorants by thin layer chromatography. Natural red colorants were consisted of major water-soluble red colorant, having maximum absorbance at 538nm and alcohol-soluble yellow colorant, having maximum absorbance at 664nm. Concentration of red colorants were calibrated by the equation of dye(mg/ml) $A_{538nm}\times{1.284}$. Red colorants were changed to yellow at extreme alkali pH and repaired 55% color intensity by neutralization of pH and stabled below $55^\circ{C}$. Dyeability of red colorants against wool fabrics was mainly operated by red pigment having 538nm absorbance without big color differences. Below $55^\circ{C}$, color differences $(\Delta{E}^*_{ab})$ were not changed in spite of big difference of chroma$(c^*)$, having higher scores at higher temperature. The effect of mordants were not drastically changed parameters of color difference without copper ion. Citric acid was big changes of color difference$(\Delta{E}^*_{ab})$ in spite of similar chroma$(c^*)$ values. From these experimental results, red colorants from Phytolacca americana Linne is available for wool fabric dyeing.

  • PDF

La(III) Selective Membrane Sensor Based on a New N-N Schiff's Base

  • Ganjali, Mohammad Reza;Matloobi, Parisa;Ghorbani, Maryam;Norouzi, Parviz;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.38-42
    • /
    • 2005
  • Bis(2-methylbenzaldehyde)butane-2,3-dihydrazone(TDSB) was used as new N-N Schiff's base which plays the role of an excellent ion carrier in the construction of a La(III) membrane sensor. The best performance was obtained with a membrane containing, 30% poly(vinyl chloride), 60% benzyl acetate, 6% TDSB and 4% sodium tetraphenyl borate. This sensor reveals a very good selectivity towards La(III) ions over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The proposed electrode exhibits a Nernstian behavior (with slope of 19.8 mV per decade) over a wide concentration range (1.0 ${\times}$ 10$^{-5}$-1.0 ${\times}$ 10$^{-1}$ M). The detection limit of the sensor is 7.0 ${\times}$ 10$^{-6}$ M. It has a very short response time, in the whole concentration range ($\sim$5 s), and can be used for at least twelve weeks in the pH range of 3.0-9.4. The proposed sensor was successfully applied as an indicator electrode for the potentiometric titration of a La(III) solution, with EDTA. It was also successfully applied in the determination of fluoride ions in three mouth wash preparations.

Anti-Cariogenicity of NCS (Non-Cariogenicity Sugar) Produced by Alkalophilic Bacillus sp. S-1013

  • Ryu, Il-Hwan;Kim, Sun-Sook;Lee, Kap-Sang
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.4
    • /
    • pp.759-765
    • /
    • 2004
  • The NCS inhibited the activity of glucosyltransferase which was produced by Streptococcus mutans JC-2, and the rate of inhibition at $100\muM<$ and $200\muM$ were 74.0% and 99.8%, respectively. It was stable in alkali condition, but unstable in acid condition. It was also stable up to $80^{\circ}C$. The kinetic study of the inhibition by NCS was carried out by Lineweaver-Burk plot and Dixon plot. It was non-competitive inhibition, determined by the two plots and $K_i$ and $K_i$ values were $15\muM$ and $19.3\muM$ respectively. The NCS did not show cytotoxicity against human gingival cells at $K_i$ ($15\muM$, $150\muM$, $1,500\mu$ M) concentrations. It had less cytotoxicity than chlohexidin, which has usually been used as the agent of anticaries. To evaluate the industrial applicability of the NCS, human pluck tooth was used. The inhibitory rates of tooth calcification and calcium ion elution by the NCS were 41 % and 2.5 times, respectively. These results suggested that NCS from Bacillus sp. S-1013 is an efficient anticaries agent.

The Effect of Water-Soluble Calcium Supplements on Calcium Metabolism and Bone Metabolism of Growing Rats

  • Jang, Se-Young;Jeong, Yong-Jin;Kwon, Teak-Kyu;Seo, Ji-Hyung;Park, Eun-Mi
    • Preventive Nutrition and Food Science
    • /
    • v.12 no.4
    • /
    • pp.217-221
    • /
    • 2007
  • Within the elderly population, the use of calcium supplements and the intake of calcium from food are on the rise in order to maintain health. Calcium is absorbed as an ion in vivo, leading to speculation that absorption efficiency is affected by the solubility of the calcium consumed. In our study, the bioavailability of two types of calcium supplements with different solubilities was evaluated. Experimental animals were fed water-soluble or insoluble calcium supplements for 6 weeks. We found that blood alkali phosphatase activity, osteocalcin content, and urine crosslinks values were not different between the groups. Similarly, the degree of apparent calcium absorption between the two calcium supplements was not significantly different. The bone mineral density and bone mineral content of the femur and the tibia increased in the group that consumed insoluble calcium compared with those of the water-soluble calcium supplemented group. However, when considering body weight, the bone mineral density value for all areas, including the spine, was significantly higher in the group that consumed the water-soluble calcium supplement.