• Title/Summary/Keyword: alignment-free method

Search Result 34, Processing Time 0.026 seconds

Si Induced Polymer Based Alignment Layer for Liquid Crystal Orientations with High Electro-Optic Properties at Low Temperature (저온 공정의 Si을 이용한 PI 배향 막의 전기광학 특성 향상에 대한 연구)

  • Kim, Dai-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.677-681
    • /
    • 2013
  • Apart from the deposition of alignment layer, alignment process needs to be involved for alignment of liquid crystal (LC) molecules. To simplify manufacturing process, several method were used such as rubbing, ion-beam irradiation, UV irradiation, and lithography. But, eventually it needs another treatment for LC alignment. Here, we suggested Si induced polyimide (PI) alignment layer at low temperature. Using this method, we are able to eliminate the alignment process and found that the alignment and electro-optic performance are much better than that of the rubbed PI LC cells. Compared to the rubbed PI cells, the response time was decreased by 70% and C-V characteristics have hysteresis-free.

Evaluation of Interference Alignment for MIMO-IC based on IEEE 802.11n (IEEE 802.11n 기반 MIMO-IC의 간섭정렬 성능평가)

  • Bae, Insan;Yun, Heesuk;Kim, Jaemoung
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.47-52
    • /
    • 2013
  • In this paper, The existing interference alignment algorithms were analyzed in Rayleigh fading channel environment. The interference alignment techniques are divided to two parts. First thing is Iterative-method, another is Linear-method. Iterative method needs local channel info, but it has the constraint of iteration. On the other hand Linear-method must have global channel info, but has free of iteration and better performance. This paper evaluates the performance of interference alignment algorithms in Rayleigh fading channel of outdoor environment and WLAN channel based on IEEE 802.11n of indoor environment.

Liquid Crystal Alignment Effect on Polyimide Surface by Ion-beam Irradiation (이온빔을 이용한 폴리이미드 표면의 액정배향효과)

  • Park, Hong-Gyu;Oh, Byeong-Yun;Kim, Young-Hwan;Kim, Byoung-Yong;Han, Jeong-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.330-330
    • /
    • 2008
  • It is widely investigated to liquid crystal (LC) alignment using non-contact alignment method such as ion-beam (IB) irradiation, UV alignment, and oblique deposition. Because conventional rubbing method has some drawbacks. These include defects from dust and electrostatic charges and rubbing scratch during rubbing process. In addition, rubbing method needs additional process to remove these defects. Therefore rubbing-free methods like ion-beam irradiation are strongly required. We studied LC alignment effect on poly imide surface by IB irradiation and electro-optical (EO) characteristics of twisted nematic liquid crystal display (TN-LCD). In this experiment, a good uniform alignment of the nematic liquid crystal (NLC) with the ion-beam exposure on the polyimide (PI) (SE-150 from Nissan Chemical) surface was observed. We also achieved low pretilt angle as a function of ion-beam irradiation intensity. In addition, it can be obtained the good EO properties of the IB-aligned TN-LCD on PI surface. Some other experiments results and discussion will be included in the poster.

  • PDF

A Defect Free Bistable C1 SSFLC Devices

  • Wang, Chenhui;Bos, Philip J.
    • Journal of Information Display
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Recent progress in both low pretilt and high pretilt defect free C1 surface stabilized ferroelectric liquid crystal (SSFLC) devices is reviewed. First, by numerical calculation to investigate the balance between surface azimuthal anchoring energy and bulk elastic energy within the confined chevron layer geometry of C1 and C2, it is possible to achieve a zigzag free C1 state by low azimuthal anchoring alignment with a low pretilt angle. The critical azimuthal anchoring coefficient for defect free C1 state is calculated. Its relationship with elastic constant, chevron angle as well as surface topography effect are also discussed. Second, using $5^{\circ}$ oblique SiO deposition alignment method a defect free, large memory angle, high contrast ratio and bistable C1 SSFLC display, which has potential for electronic paper applications has also been developed. The electrooptical properties and bistability of this device have been investigated. Various aspects of defect control are also discussed.

Symmetric-viewing liquid crystal display with alternating alignment layers in an inverse-twisted-nematic configuration

  • Na, Jun-Hee;Li, Hongmei;Park, Seung-Chul;Lee, Sin-Doo
    • Journal of Information Display
    • /
    • v.12 no.4
    • /
    • pp.191-194
    • /
    • 2011
  • A symmetric-viewing inverse-twisted-nematic (ITN) liquid crystal display (LCD) with alternating alignment layers was developed using a stamping-assisted rubbing (SAR) technique. A patterned layer of a fluorinated acrylate polymer was transferred onto the first rubbed vertical-alignment layer prepared on a substrate by stamping. The fluorinated acrylate polymer provided a protective layer covering the first rubbed alignment layer during the second rubbing process, which promoted the vertical alignment of the LC molecules. The LC cell in the ITN geometry with two orthogonally rubbed alignment layers showed symmetric-viewing characteristics with fourfold symmetry. The SAR technique was shown to be a mask-free alignment method of producing multidomains for symmetric-viewing LCDs.

Stamping-assisted Fabrication Technique of the Bidirectional Alignment Layer for Wide-Viewing Twisted-Nematic Liquid Crystal Displays

  • Koo, Kyung-Mo;Na, Jun-Hee;Kim, Yeun-Tae;Li, Hongmei;Lee, Sin-Doo
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.180-183
    • /
    • 2009
  • A stamping-assisted rubbing technique for generating bidirectional alignment in the fabrication of wide-viewing twistednematic (TN) liquid crystal displays (LCDs) was developed. A patterned layer of a fluorinated acrylate polymer was transferred onto the first rubbed alignment layer prepared on a substrate by stamping. The fluorinated acrylate polymer provides a protective layer that covers the first alignment layer during the second rubbing process to facilitate the bidirectional alignment of the LC molecules. The LC cell in the twisted geometry with two bidirectional-alignment layers showed stable electro-optic properties and wide-viewing characteristics. The stamping-assisted rubbing technique serves as a mask-free alignment method of producing multidomains for wide-viewing LCDs.

Comparison between Two Coordinate Transformation-Based Orientation Alignment Methods (좌표변환 기반의 두 자세 정렬 기법 비교)

  • Lee, Jung-Keun;Jung, Woo-Chang
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.30-35
    • /
    • 2019
  • Inertial measurement units (IMUs) are widely used for wearable motion-capturing systems in the fields of biomechanics and robotics. When the IMUs are combined with optical motion sensors (hereafter, OPTs) for their complementary capabilities, it is necessary to align the coordinate system orientations between the IMU and OPT. In this study, we compare the application of two coordinate transformation-based orientation alignment methods between two coordinate systems. The first method (M1) applies angular velocity coordinate transformation, while the other method (M2) applies gyroscopic angle coordinate transformation. In M1 and M2, the angular velocities and angles, respectively, are acquired during random movement for a least-square algorithm to determine the alignment matrix between the two coordinate systems. The performance of each method is evaluated under various conditions according to the type of motion during measurement, number of data points, amount of noise, and the alignment matrix. The results show that M1 is free from drift errors, while drift errors are present in most cases where M2 is applied. Thus, this study indicates that M1 has a far superior performance than M2 for the alignment of IMU and OPT coordinate systems for motion analysis.

Effect of an 8-week Closed Kinetic Chain Styled Pilates Exercise on Lower Limb Alignment (8주간 닫힌 사슬형 필라테스 운동이 하지 정렬에 미치는 영향)

  • Ga Ram Jeon;Sukhoon Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.4
    • /
    • pp.128-136
    • /
    • 2023
  • Objective: The aim of this study was to investigate the effect of an 8-week closed kinetic chain typed Reformer and Chair Pilates exercise on static and dynamic lower limb alignment for healthy female adults. Method: Ten healthy young female adults without musculoskeletal injury history in last 6 months (Age: 29.3 ± 3.5 yrs., Height: 165 ± 3.4 cm, Body mass: 58.2 ± 5.4 kg) participated in this study. All participants asked to join the 8-week closed kinetic chain typed Reformer and Chair Pilates exercise, and the program was conducted for 60 minutes twice a week. Participants were asked to be measure a static Q-angle and performed free squat one week before and after the program. A 3-D motion analysis with 8 infrared cameras and 5 channels of EMG was executed in this study. The effectiveness of the training was evaluated by paired t-test, and the significance level was set at .05. Results: A significantly decreased in internal rotation angles was found at hip joint during free squat after the training. Also, significantly decreased in lateral rotation angles were found at knee and ankle joint during free squat after training. Finally, significantly decreased in muscle activations were found at adductor longus and peroneus longus during free squat after training. Conclusion: From results of our study, it is concluded that an 8-week closed kinetic chain typed Pilates exercise positively effect on lower limb alignment during dynamic movement.

Alignment of Schwarzchild-Chang Off-axis Telescope with a Shack-Hartmann Wavefront Sensor and Sensitivity Table Method

  • Lee, Sunwoo;Park, Woojin;Kim, Yunjong;Kim, Sanghyuk;Chang, Seunghyuk;Jeong, Byeongjoon;Kim, Geon Hee;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.79.1-79.1
    • /
    • 2019
  • The Schwarzchild-Chang telescope is a confocal off-axis two mirror telescope with D = 50 mm, F = 100 mm and FOV = 8 ° × 8 °. Unlike common off-axis telescopes, the mirrors of the Schwarzchild-Chang telescope share their focal points to remove the linear astigmatism. In this poster, we show the alignment process of the Schwarzchild-Chang telescope with wavefront measurement and the sensitivity table method. Wavefront is measured using the Shack-Hartmann sensor, and Zernike polynomials are obtained from measured wavefront. Sensitivity table method is to calculate alignment errors from the Zernike coefficients. As a result, we evaluate tilt, decenter, and despace of each mirror of linear astigmatism-free con-focal off-axis system.

  • PDF

Properties of liquid crystal alignment layers exposued to ion-beam irradiation enemies (이온빔 에너지에 따른 액정배향막의 전기광학적 특성연구)

  • Oh, Byeong-Yun;Lee, Kang-Min;Park, Hong-Gyu;Kim, Byoung-Yong;Kang, Dong-Hun;Han, Jin-Woo;Kim, Young-Hwan;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.430-430
    • /
    • 2007
  • In general, polyimides (PIs) are used in liquid crystal displays (LCDs) as alignment layer of liquid crystals (LCs). Up to date, the rubbing alignment technique has been widely used to align liquid crystals on the PI surface, which is suitable for mass-production of LCDs because of its simple process and high productivity. However, this method has some disadvantages. Rubbed PI surfaces include the debris left by the cloth and the generation of electrostatic charges during rubbing process. Therefore, rubbing-free techniques for LC alignment are strongly required in LCD technology. In this experiment, PI was uniformly coated on indium-tin-oxide electrode substrates to form LC alignment layers using a spin-coating method and the PI layers were subsequently imidized at 433 K for 1 h. The thickness of the PI layer was set at 50 nm. The LC alignment layer surfaces were exposed to an $Ar^+$ ion-beam under various ion-beam energies. The antiparallel cells and twisted-nematic (TN) cells for the measurement of pretile angle and electro-optical characteristics were fabricated with the cell gap of 60 and $5\;{\mu}m$, respectively. The LC cells were filled with nematic LC (NLC, MJ001929, Merck) and were assembled. The NLC alignment capability on ion-beam-treated PI was observed using photomicroscope and the pretilt angle of the NLC was measured by the crystal-rotation method at room temperature. Voltage-transmittance (V-T) and response time characteristics of the ion-beam irradiated TN cell were measured by a LCD evaluation system.

  • PDF