• Title/Summary/Keyword: air-operated valve

Search Result 60, Processing Time 0.025 seconds

Development of Reliability Analysis Program for Air Operated Valve (공기구동밸브 신뢰도 분석 모듈 개발)

  • 허태영;양상민;김봉호;송동섭;김찬용;이우준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1080-1082
    • /
    • 2003
  • To develop a reliability analysis program applied to the diagnosis for air operated valve's integrity. we collected, analyzed AOV failure data from foreign and domestic nuclear power plants, and classified whole subjects of this program into several groups according to type and size. We established a theoretical basis using Lognormal Distribution and Bayesian Theory to develop analysis methodology. The result of this program was applied to the calculation of operational unavailability of AOV, and the effect of AOV's failure. Also this program can be applied to the development of diagnostic technique considering AOV environment (temperature, pressure), and setting-up maintenance cycle.

  • PDF

Air-Operated Valve Diagnostic System Development (공기구동밸브의 진단시스템 개발)

  • 양상민;송동섭;허태영;김봉호;신성기;김찬용;조택동
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.430-433
    • /
    • 2003
  • Air-operated valve is one of principal valves that are using to control fluid flow. A period diagnosis for safety of power plants is necessary. But there are many difficulties such as economic loss caused by intone of high cost devices and a matter hard to deal with users. In this study we developed the diagnosis system that usersofpower plants are easy to handle. The diagnosis system is composed of database module, reliability analysis module, design safety nodule and diagnosis test and evaluation module.

  • PDF

Study on a Self Diagnostic Monitoring System for an Air-Operated Valve: Development of a Fault Library

  • Chai Jangbom;Kim Yunchul;Kim Wooshik;Cho Hangduke
    • Nuclear Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.210-218
    • /
    • 2004
  • In the interest of nuclear power plant safety, a self-diagnostic monitoring system (SDMS) is needed to monitor defects in safety-related components. An air-operated valve (AOV) is one of the components to be monitored since the failure of its operation could potentially have catastrophic consequences. In this paper, a model of the AOV is developed with the parameters that affect the operational characteristics. The model is useful for both understanding the operation and correlating parameters and defects. Various defects are introduced in the experiments to construct a fault library, which will be used in a pattern recognition approach. Finally, the validity of the fault library is examined.

Study on the Self Diagnostic Monitoring System for an Air-Operated Valve : Algorithm for Diagnosing Defects

  • Kim Wooshik;Chai Jangbom;Choi Hyunwoo
    • Nuclear Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.219-228
    • /
    • 2004
  • [1] and [2] present an approach to diagnosing possible defects in the mechanical systems of a nuclear power plant. In this paper, by using a fault library as a database and training data, we develop a diagnostic algorithm 1) to decide whether an Air Operated Valve system is sound or not and 2) to identify the defect from which an Air-Operated Valve system suffers, if any. This algorithm is composed of three stages: a neural net stage, a non-neural net stage, and an integration stage. The neural net stage is a simple perceptron, a pattern-recognition module, using a neural net. The non-neural net stage is a simple pattern-matching algorithm, which translates the degree of matching into a corresponding number. The integration stage collects each output and makes a decision. We present a simulation result and confirm that the developed algorithm works accurately, if the input matches one in the database.

Development of Diagnosis System for Diaphragm Operated Globe Valve (다이어프램 구동형 글로브 밸브의 진단장비 개발)

  • Yang, Sang-Min;Shin, Sung-Ky
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.975-980
    • /
    • 2007
  • Air-operated valve is one of principal valves that are used to control fluid flow in nuclear power plants. A periodic diagnosis for the safety of power plants is necessary. But there are many difficulties such as economic loss caused by income of high cost devices and a matter hard to deal with users. In this study, we developed the diagnostic system that users of power plants are easy to handle. The diagnostic system is composed of database module, diagnosis test module and analysis module.

The Development of Performance Evaluation System for Air-Operated Actuaotr (공기구동기 성능평가 시스템 개발)

  • Cho T.D.;Yang S.B.;Lee H.Y.;Yang S.M.;Kwon B.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1770-1773
    • /
    • 2005
  • The performance evaluation of AOV(air-operated valve) requires the processes to confirm the actuator system capability. It is necessary to evaluate the thrust of the air actuator for the margin evaluation. In this paper, to evaluate and analysis the air actuator, the performance test system and operating program are developed. This system is composed of several sensors such as pressure sensor, LVDT, and LoadCell which are used to get the data for evaluation. The LabVIEW was used for developing the operating program. The test system and operating program are proved through the actual test of the diaphragm actuator.

  • PDF

Performance Analysis of Air Operated Valve by Thermal Aging (공기구동밸브의 열노화에 따른 성능평가)

  • Lee, Sun-Ki
    • Journal of Power System Engineering
    • /
    • v.19 no.5
    • /
    • pp.93-98
    • /
    • 2015
  • Nuclear power plants has a number of valves, which are operating at a high temperature-high pressure and radiation environment conditions. Nevertheless, it is important to maintain the reliability of the valves to ensure safe operation of the nuclear power plant. However, the aging of the valves by increasing of years of plant operation and the system transients due to the sudden load change are working the failures of the reliability of the valve. In this paper, we evaluate experimentally the performance change according to the thermal aging of the valve. Results show that the valve stem and the actuator leakages were enlarged by the thermal aging.

A Computational Analysis of Water-Hammer (수격현상에 대한 수치적 고찰)

  • Chun, Kwang-Min
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 1982
  • The water-hammer phenomena caused by pump power failure are analysed by digital computer. Asan cool ins water pipe system has been chosen as a model. It is Shown that after power failure the pressure at the pump outlet drops sharply, and to prevent reverse flow, either butterfly valve or check valve can be used. After the valve closure, pressure oscillates behind the valve. To weaken the pressure wave, it is recommended to install a servo-operated valve in a bypass Line around the pamp and the check valve.

  • PDF

Dynamic Analysis of Air Operated Globe Valve (공기구동형 글로브밸브의 동적거동해석)

  • 양상민;박종학;김동진;허태영;김봉호;신성기;김찬용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1022-1025
    • /
    • 2003
  • Although the globe is the most typical valve to control high pressure drop in piping system, it is very hard to figure out the characteristics of flow field in the globe valve caused by its complex geometry. So there is very few studies to find out flow characteristics of globe valve. In this study, numerical analysis for flow field in the globe valve is carried out using the Fluent code which is commercial CFD program. Pressure drop through the globe valve is also measured to verify the results come from numerical analysis. Comparing experiment with numerical analysis, two results are very close to each other. Also finite element method is employed to evaluate the safety of globe valve using the results coming from the flow analysis to make the boundary conditions for FEM analysis. Maximum stress appears on the inlet channel of valve where inlet flow runs against. Because the maximum stress between 11.7 MPa to 3.6 MPa is within 3.4% of yield stress. the structural safety of valve is considered to be very sound

  • PDF

The Development of Diagnostic System for Testing Air-Operated Valves (공기구동 밸브의 진단장비 개발)

  • Yang, S.M.;Hong, S.D.;Sin, S.K.;Park, C.K.;Song, D.S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.481-487
    • /
    • 2004
  • Air-operated valve is one of principal valves that are using to control fluid flow in nuclear power plants. A period diagnosis lot safety of power plants is necessary. But there are many difficulties such as economic loss caused by income of high cost devices and a matter hard to deal with users. In this study, we developed the diagnostic system that users of power plants are easy to handle. The diagnostic system is composed of database module, diagnosis test module and evaluation module.

  • PDF