• 제목/요약/키워드: air quality monitoring system

검색결과 162건 처리시간 0.031초

Review of Internet of Things-Based Artificial Intelligence Analysis Method through Real-Time Indoor Air Quality and Health Effect Monitoring: Focusing on Indoor Air Pollution That Are Harmful to the Respiratory Organ

  • Eunmi Mun;Jaehyuk Cho
    • Tuberculosis and Respiratory Diseases
    • /
    • 제86권1호
    • /
    • pp.23-32
    • /
    • 2023
  • Everyone is aware that air and environmental pollutants are harmful to health. Among them, indoor air quality directly affects physical health, such as respiratory rather than outdoor air. However, studies that have examined the correlation between environmental and health information have been conducted with public data targeting large cohorts, and studies with real-time data analysis are insufficient. Therefore, this research explores the research with an indoor air quality monitoring (AQM) system based on developing environmental detection sensors and the internet of things to collect, monitor, and analyze environmental and health data from various data sources in real-time. It explores the usage of wearable devices for health monitoring systems. In addition, the availability of big data and artificial intelligence analysis and prediction has increased, investigating algorithmic studies for accurate prediction of hazardous environments and health impacts. Regarding health effects, techniques to prevent respiratory and related diseases were reviewed.

무선센서네트워크에 기반한 공기질 모니터링 연구 (Study of Air Quality Monitoring based on Wireless Sensor Network)

  • 박덕신;조영민;권순박;박은영;옥민환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1756-1760
    • /
    • 2008
  • In this study, it was suggested how to monitor the air quality with use of intelligent wireless sensor network in the subway station. When Zigbee-based ubiquitous sensor network was used, smaller budget was required in configuring the system compared to existing air-quality monitoring method and this system may easily be configured due to easy installation of communication cables. The study will be continued to supplement the network systems currently installed in subway stations and the completion of development of this system is expected to make a large contribution in improvement of indoor air quality.

  • PDF

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF

한국에서의 환경영향평가와 환경측정 (Environmental Impact Assessment and Environmental Monitoring in Korea)

  • 강인구;김명진
    • 환경영향평가
    • /
    • 제4권3호
    • /
    • pp.31-39
    • /
    • 1995
  • Environmental Impact Assessment (EIA) is composed of various procedures, such as screening, scoping, inventory survey, prediction, assessment, alternative assessment, mitigation measures, and post management. Environmental monitoring data for air quality or water quality, etc. is applied in the EIA process, especially in prediction and post management. As an effective tool of environmental monitoring, the remote sensing method, introduced recently, was used in collecting nationwide data concerning ecosystem and land use. This article explains the current monitoring status in Korea. Monitoring factors include air quality, water quality, soil, ocean, odor, noise, and ecosystems. This report explains the organization of the environmental monitoring system managed by the Ministry of Environment in Korea. Furthermore, it shows the environmental criteria and environmental policies applied to EIA in Korea.

  • PDF

실내공기질 개선 시스템의 서버 구성 방식에 따른 응답 시간의 차이 비교 (Comparison of the Difference in Response Time According to the Server Configuration Type of the Indoor Air Quality Improvement System)

  • 국중진
    • 반도체디스플레이기술학회지
    • /
    • 제22권1호
    • /
    • pp.59-63
    • /
    • 2023
  • Various devices have been emerging as a means of measuring indoor air quality, and among them, there are devices that support real-time remote monitoring through IoT technology and a cloud environment. To improve indoor air quality, based on the results determined by measuring devices, air purifiers or ventilation systems may need to be operated, and temperature and humidity control may be required. In this paper, we propose a design of indoor air quality measuring devices required for indoor air quality evaluation, and of the system needed to control relevant devices to improve indoor air quality through the interaction with the measuring devices. Currently, the servers for the interaction of indoor air quality devices and IoT devices are divided into conventional server type and serverless type, comparing the differences in response time of IoT devices to changes of indoor air quality.

  • PDF

Envi-met 모델을 이용한 도심지역 대기오염측정망 주변의 바람장 분석 (An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model)

  • 김민경;이화운;도우곤;정우식
    • 한국환경과학회지
    • /
    • 제18권9호
    • /
    • pp.941-952
    • /
    • 2009
  • The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.

지하역사의 공기질 감시 시스템 구성에 관한 연구 (A Study on Indoor Air Quality Monitoring System for Subway Stations)

  • 이병석;황선주;이준화;김규식;김조천
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.48-50
    • /
    • 2009
  • This paper presents an IAQ(Indoor Air Quality) Monitoring System using equipments for measurement of fine Particle($PM1{\sim}PM10$), $CO_2$, VOCs(Volatile Organic Compounds), temperature and humidity for IAQ monitoring of subway station which millions of people use a day. The necessity of IAQ monitoring system is getting increased for more effective subway station monitoring in line with the recent government's regulation for IAQ is reinforcing. Subway Station is an unusual case. The structure of subway station is closed and complicated. Therefore when data of equipments are transferred, transmission error can happen occasionally. To prevent transmission error, an IAQ Monitoring System is needed the appropriate position and selection of equipments or sensor module. In addition IT(Information Technology) can be utilized like "WiBro(Wireless Broadband)" and "GateWay" for facilitate movement of data and construction of IAQ monitoring system of subway station.

  • PDF

서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가 (Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station)

  • 임봉빈;이규성;김주인;홍현수;김장원;조경호;정을규;김인규;안연순
    • 한국대기환경학회지
    • /
    • 제30권3호
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

실시간 위치탐지 기능을 갖춘 대기오염 모니터링 RF-Sensor 시스템 (Air Pollution Monitoring RF-Sensor System Trackable in Real Time)

  • 김진영;조장호;전일태;정달도;강준희
    • 대한공간정보학회지
    • /
    • 제18권2호
    • /
    • pp.21-28
    • /
    • 2010
  • 대기오염 모니터링은 삶의 질 향상에 직접적으로 연관되어 많은 관심을 받고 있다. 현재 운영되고 있는 대부분의 대기질 정보 시스템은 특정장소에 측정소를 구축하여 대기 질을 측정하고 있으며, 고가의 장비를 사용하기 때문에 다양한 장소에 설치하여 운영하는데 어려움을 겪고 있다. 본 연구에서는 이러한 문제를 보완하기 위하여 소형화 측정시스템을 구현하였다. 뿐만 아니라 제작비용을 최소화하여 대기 오염 예보에 적용할 수 있는 무선센서 시스템을 구현하였다. 본 연구에서 개발한 대기오염 모니터링 시스템은 대기오염을 측정하기 위한 센서부, 취득된 대기오염 정보를 처리하는 중앙처리부, 전원공급을 위한 전원부, 그리고 무선으로 데이터를 송수신하기 위한 무선회로를 구성하였으며, 실제 현장에 직접 적용할 수 있도록 구성하였다. 또한, Global Positioning System(GPS) 회로를 장착하여 센서의 위치 정보를 무선 송신할 수 있도록 함으로써 실시간 위치추적을 할 수 있도록 하였다. 다양한 대기 환경을 측정하기 위해서 CO, $O_3$, $NO_2$ 센서 및 먼지센서를 장착하였다.

유해대기오염물질 모니터링을 위한 대도시 우선순위 측정지점 선정기법 제안 (Suggestions on the Selection Method of Priority Monitoring Sites for Hazardous Air Pollutants in Megacities)

  • 권혜옥;김성준;김용표;김상균;홍지형;최성득
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.544-553
    • /
    • 2017
  • There is an overall guideline of the installation of air quality monitoring stations in Korea, but specified steps for the selection of monitoring sites for hazardous air pollutants(HAPs) are not provided. In this study, we proposed a systematic method for the selection of monitoring sites for HAPs using geographic information system (GIS). As a case study, the Seoul metropolitan area (Seoul, Incheon, and Gyeonggi Province) was chosen, and 15 factors including population, vehicle registration, and emission data were compiled for each grid cell ($7km{\times}7km$). The number of factors above the top 30% of individual data for each grid cell was used to select priority monitoring sites for HAPs. In addition, several background sites were added for data comparison and source identification. Three scenarios were suggested: Scenario 1 with 7 sites, Scenario 2 with 17 sites, and Scenario 3 with 30 sites. This proposal is not the final result for an intensive monitoring program, but it is an example of method development for selecting appropriate sampling sites. These results can be applied not only to HAPs monitoring in megacities but also to the national HAPs monitoring network.