• Title/Summary/Keyword: air pollution control devices

Search Result 28, Processing Time 0.033 seconds

A review of elemental mercury removal processing

  • Bae, Kyong-Min;Kim, Byung-Joo;Park, Soo-Jin
    • Carbon letters
    • /
    • v.12 no.3
    • /
    • pp.121-130
    • /
    • 2011
  • Public concern has recently increased over the potential risk of toxic elements emitted from anthropogenic sources. Among these, mercury has drawn special attention owing to its increasing level of bioaccumulation in the environment and in the food chain, with potential risks for human health. This paper presents an overview of research related to mercury control technology and identifies areas requiring additional research and development. It critically reviews measured mercury emissions progress in the development of promising control technologies, including catalytic oxidation, sorbent injection, photochemistry oxidation, and air pollution control devices.

Current Management Status of Mercury Emissions from Coal Combustion Facilities: International Regulations, Sampling Methods, and Control Technologies

  • Lee, Sung-Jun;Pudasainee, Deepak;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.E1
    • /
    • pp.1-11
    • /
    • 2008
  • Mercury (Hg), which is mainly emitted from coal-fired power plants, remains one of the most toxic compounds to both humans and ecosystems. Hg pollution is not a local or regional issue, but a global issue. Hg compounds emitted from anthropogenic sources such as coal-fired power plants, incinerators, and boilers, can be transported over long distances. Since the last decade, many European countries, Canada, and especially the United States, have focused on technology to control Hg emissions. Korea has also recently showed an interest in managing Hg pollution from various combustion sources. Previous studies indicate that coal-fired power plants are one of the major sources of Hg in Korea. However, lack of Hg emission data and feasible emission controls have been major obstacles in Hg study. In order to achieve effective Hg control, understanding the characteristics of current Hg sampling methods and control technologies is essential. There is no one proven technology that fits all Hg emission sources, because Hg emission and control efficiency depend on fuel type, configuration of air pollution control devices, flue gas composition, among others. Therefore, a broad knowledge of Hg sampling and control technologies is necessary to select the most suitable method for each Hg-emitting source. In this paper, various Hg sampling methods, including wet chemistry, dry sorbents trap, field, and laboratory demonstrated control technologies, and international regulations, are introduced, with a focus on coal-fired power plants.

A Study on the Correlation Level Among Air Pollution from Solid waste Incinerator (고형폐기물 소각로에서 배출되는 대기오염물질간의 상관성에 관한 연구)

  • 조상원
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.183-187
    • /
    • 1999
  • The purpose of this study is providing basic data to control the air pollutants from solid waste incinerator. Incinerating the waste wood, the electrostatic precipitator had the best collection efficiency. The leather incineration had the same collection efficiency as synthetic resin incineration. And the coarse particle collection efficiency was high. As you know in correlation of leather incineration. pollutants produced a from incinerator are mostly fine particles. If the scrubber used only in the process produced a lot of fine particles. It is adequate to use the above control devices, together with high efficiency collector like bag-filter. To select the adequate control devices, it is required to investigate the size distribution before establishing control devices.

  • PDF

Impact of the Exclusive Median Bus Lane System on Air Pollution Concentrations in Seoul, Korea (서울시 중앙버스전용차로 도입의 부가적인 대기오염 영향성 평가)

  • Baik, Yeon-Ju;Kim, Da-Wool;Kwon, Hye-Young;Kim, Youngkook;Kim, Sun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.542-553
    • /
    • 2018
  • Since many previous studies reported the health effect of air pollution and indicated traffic as a major pollution source, significant policy efforts have been made to control traffic to reduce air pollution. However, there have been few studies that evaluated such policy implementation. In Seoul, Korea, the exclusive median bus lane system was implemented in 2004, and the metropolitan government applied air pollution reduction policies such as conversion of diesel buses to compressed natural gas buses and installation of emission control devices. This paper aimed to investigate the impact of the exclusive median bus lane system on air pollution reduction. Using hourly concentrations of particulate matter ($PM_{10}$) and nitrogen dioxide ($NO_2$) measured at 131 regulatory monitoring sites in Seoul and Gyeonggi-do for 2001-2014, we calculated annual and daily average concentrations at each site. We assessed the impact of the policy using differences-in-differences analysis by annual and daily average models after adjusting for geographic and/or meteorological variables. This method divides population into treatment and control groups with and without policy application, and compares the difference between the two time periods before and after the policy implementation in the treatment group with the difference in the control group. We classified all monitoring sites into treatment and control groups using two definitions: 1) Seoul vs. Gyeonggi-do; 2) within vs. outside 300 meters from the median bus lane. Pre- and post-policy periods were defined as 2001-2005 and 2006-2014, and 2004 and 2014 in the annual and daily models, respectively. The decrease in $PM_{10}$ concentrations between the two periods across monitoring sites in the treatment group was larger by $1.73-5.88{\mu}g/m^3$ than in the control group. $NO_2$ also showed the decrease without statistical significance. Our findings suggest that an efficient public transport policy combined with pollution abatement policies can contribute to reduction in air pollution.

Effective Control of fine Particles Using an Electrostatic Coagulation Between Particle and Water Droplet (입자와 액적간의 정전기적 응집을 통한 미세입자의 효율적인 제어)

  • Lee, Myong-Hwa;Kim, Sang-Bum;Hwang, You-Seong;Kim, Jong-Ho;Kim, Gyung-Soo
    • Journal of ILASS-Korea
    • /
    • v.11 no.2
    • /
    • pp.98-104
    • /
    • 2006
  • A charged droplet scrubber was introduced to remove visible smokes generated in many industrial facilities. Lab-scale and field tests were conducted in this study. The system consists of a corona discharger to effectively charge the fine particles, fellowed by an electrostatic chamber to promote coagulation between charged fine particles and oppositely charged droplets and a demister to remove resultant particles. Overall collection efficiency, 98.4% was obtained from a lab-scale test, when a high voltage was applied to an ionizer and a charged droplet scrubber. Field tests also show the high collection efficiencies, 93.5% with one stage and 99.4% with two stage system. This system can be used to increase the collection efficiency of the conventional air pollution control devices to satisfy the national emission standard.

  • PDF

Integrated Environment Impact Assessment of Brick Kiln using Environmental Performance Scores

  • Pokhrel, Rajib;Lee, Heekwan
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.15-24
    • /
    • 2014
  • The capital city of Himalayan Country Nepal, Kathmandu Valley is surrounded by consecutive high mountains, which limits the air distribution and mixing effects significantly. It in turn generates steady air flow pattern over a year except in monsoon season. The air shed in the Valley is easily trapped by the surrounded mountains and the inversion layer formulated as the cap. The $PM_{10}$ concentration was noticeably higher than the standard level (120 ${\mu}g/m^3$) in urban and suburban area of Kathmandu valley for all seasons except monsoon period. The Valley area experiences similar wind patterns (W, WWS, and S) for a year but the Easterly wind prevails only during the monsoon period. There was low and calm wind blows during the winter season. Because of this air flow structure, the air emission from various sources is accumulated within the valley air, high level of air pollution is frequently recorded with other air polluted cities over the world. In this Valley area, brick kilns are recognized as the major air pollution source followed by vehicles. Mostly Bull Trench Kiln (BKT), Hoffman Kiln and Vertical Shaft Brick Kiln (VSBK) are in operation for brick firing in Kathmandu valley where the fuels such as crushed coal, saw dust, and natural gas are used for processing bricks in this study. Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI) was used for screening and quantifying the potential impacts of air emission from firing fuels. The total Environmental Performance Score (EPS) was estimated and the EPS of coal was approximately 2.5 times higher than those of natural gas and saw dust. It is concluded that the crushed coal has more negative impact to the environment and human health than other fuel sources. Concerning the human health and environment point of view, alternative environment friendly firing fuel need to be used for brick industry in the kiln and the air pollution control devices also need to be applied for minimizing the air emissions from the kilns.

A Study on the Prevention of Spill of Fuel Oils and Lubricating Oils for Sunken Ships

  • Han, Won-Heui;Ju, Hae-Ji
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.3
    • /
    • pp.309-314
    • /
    • 2015
  • A sunken ship often involves an oil spill. This paper was carried out to minimize environmental and cost damages stemming from oil spil of sunken shipl. Through the analysis of both the standards of the oil tank system and installation, we have identified potential oil spill sites and proposed a remedy of prevention. The result of study, the air pipes of the oil tank are a vulnerable point for oil spill. Also, the remote control devices of emergency shut-off valve have poor accessibility at abandon ship, making it difficult to shut off the emergency shut-off valve. Thus, we propose the addition of a remote quick closing valve in the air pipe and the building of a central control system.

Emission Characteristics of PCDD/Fs in MSW Incinerator(I) - The Effect of Air Pollution Control Device - (도시폐기물 소각공장에서의 다이옥신 배출특성(I) - 방지시설의 영향 -)

  • Kim, Jin-Beom;Lee, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1817-1824
    • /
    • 2000
  • This study is carried out to investigate the discharge characteristics of PCDD/Fs from municipal solid waste(MSW) incinerator, According to the results measured at several air pollution control devices(APCDs), the largest amount of polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs) are found at selective catalytic reduction (SCR) inlet. Therefore, it concludes that the electrostatic precipitator(EP) provides the appropriate condition for the formation of PCDD/Fs. The concentration of PCDD/Fs shows a large difference with the season. The concentration of PCDD/Fs in winter is higher than that of autumn, which suggests that the formation of PCDD/Fs is affected by the MSW components and the operation condition of municipal solid waste incinerator(MSWI).

  • PDF