• Title/Summary/Keyword: air form

Search Result 1,172, Processing Time 0.028 seconds

Characteristics of Air Pollutants Emission from Medium-duty Trucks Equipped EGR and SCR in Korea (국내 EGR과 SCR 장착 중형트럭 대기오염물질 배출 특성)

  • Son, Jihwan;Kim, Jounghwa;Jung, Sungwoon;Yoo, Heungmin;Hong, Heekyung;Mun, Sunhee;Choi, Kwangho;Lee, Jongtae;Kim, Jeongsoo
    • Journal of ILASS-Korea
    • /
    • v.21 no.3
    • /
    • pp.130-136
    • /
    • 2016
  • NOx and PM are important air pollutants as vehicle management policy aspect. Medium-duty truck is the main source of the pollutants although the vehicle market share is only 3.5%. National emission portion of NOx and PM form the mobile sourece are 14% and 16% respectively. In this study it was investigated that characteristics of air pollutants emission on medium duty truck equipped with EGR and SCR system. Vehicle's test reflected driving cycle on the chassis dynamometer, and applied test cycle was WHVC(World Harmonized Vehicle Cycle) mode. The test cycle include three segments, represent urban, rural and motorway driving. Based on the test results NOx, PM, HC were less emitted form SCR vehicle than EGR vehicle. And CO was less emitted form EGR vehicle than SCR vehicle due to CO oxidation reaction on DPF surface. And most air pollutants reduced as average vehicle speed increased. Pollutants were less emitted on motorway section than urban and rural sections. But highly NOx emission on motorway section was verified according to increased EGR ratio on fast vehicle speed. HC and CO additional emission was identified as 68%, 58% respectively during SCR vehicle's cold engine start emission test. NOx additional emission was detected by 24% on SCR vehicle's condition of engine cold start while not detected on vehicle equipped with EGR. SCR vehicle's additional NOx emission was derived from low reaction temperature during engine cold start condition. medium-duty truck emission characteristics were investigated in this study and expected to used to improve air pollutants management policy of medium-duty truck equipped with SCR & EGR.

Field Case Study of Mechanized Form Roads Pavement Construction using Cellulose Fiber Reinforced Concrete (셀룰로오스 섬유보강 콘크리트를 사용한 기계화경작로 확·포장공사의 현장사례 연구)

  • Park, Jong Gun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.2
    • /
    • pp.47-56
    • /
    • 2015
  • At the present, the mechanized form roads pavement was constructed with plain concrete. Mostly, it was used by welded wire mesh for preventing crack. Cellulose fibers for the reinforcement of concrete offer relatively high levels of elastic modulus, fiber count (per unit weight), specific surface, and bond strength to cement-based materials. The construction of concrete pavement confirmed that cellulose fiber reinforced concrete was applicable to mechanized form roads pavement. In the study, cellulose fibers were used here at 0.08 % volume fraction, which is equivalent to a fiber content of $1.2kg/m^3$. Cellulose fiber reinforced concrete were compared with plain concrete. Field test results indicated that cellulose fiber reinforced concrete showed slightly to increase of 28 days compressive strength and improved the initial strength. it tended to increase of splitting tensile strength. Test results showed that the slump and air content tend to decreased. but, the variation of air contends is very little. Also, construction cost of cellulose fiber reinforced concrete is less than about 25.7 % the case of welded wire mesh previously used. Therefore, The cost reduction is expected to be possible in construction site by mechanized form roads pavement.

Effects of the Lift Valve Opening Area on Water Hammer Pump Performance and Flow Behavior in the Valve Chamber

  • Saito, Sumio;Dejima, Keita;Takahashi, Masaaki;Hijikata, Gaku;Iwamura, Takuya
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.3
    • /
    • pp.109-116
    • /
    • 2012
  • Water hammer pumps can effectively use the water hammer phenomenon for water pumping. They are capable of providing an effective fluid transport method in regions without a well-developed social infrastructure. The results of experiments examining the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. However, these conventional studies have not fully evaluated pump performance in terms of pump head and flow rate, common measures of pump performance. The authors have focused on the effects on the pump performance of various geometric form factors in water hammer pumps. The previous study examined how the hydrodynamic characteristics was affected by the inner diameter ratio of the drive and lift pipes and the angle of the drive pipe, basic form factors of water hammer pumps. The previous papers also showed that the behavior of water hammer pump operation could be divided into four characteristic phases. The behavior of temporal changes in valve chamber and air chamber pressures according to the air volume in the air chamber located downstream of the lift valve was also clarified in connection with changes in water hammer pump performance. In addition, the effects on water hammer pump performance of the length of the spring attached to the drain valve and the drain pipe angle, form factors around the drain valve, were examined experimentally. This study focuses on the form of the lift valve, a major component of water hammer pumps, and examines the effects of the size of the lift valve opening area on water hammer pump performance. It also clarifies the behavior of flow in the valve chamber during water hammer pump operation.

An Equation of State for the PVT Behavior of Gaseous Refrigerants (기체냉매의 PVT 거동을 나타내기 위한 상태방정식)

  • Park, K.;Sonntag, R.E.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.98-111
    • /
    • 1995
  • The objective of this work is to investigate the form of equations of state for specific refrigerants. In particular, equations of the extended van der Waals form have been studied. As a result, a new equation of state has been developed and tested over ranges of pressure and density up to 5 and 1.5 times critical, respectively. The equation of state separates the compressibility factor into two parts. One is the repulsive compressibility factor and the other is attractive. The former is in the same form of Carnahan-Starling's repulsive term with constant hard-sphere volume. The latter is based on a combination of two different functions linear to density. The equation of state developed here has 12 adjustable parameters and correlates PVT data successfully. All properties are in reduced forms.

  • PDF

A solution method of view factor by the area weighted average and graphical methods (면적가중 평균법과 그래프 해법에 의한 형태계수의 해석)

  • 유승호;손장열
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.709-715
    • /
    • 1999
  • To optimize a heating and cooling system, we need an exact solution lot radiant heat transfer in any form of room or building. This paper describes the solution method of view factor by the area weighted average and graphical method to calculate the radiant heat exchange or daylighting level in any form of room or building. This study shows that the area weighted average and graphical methods have many points of merits(calculation speed, correctness and calculation capability in an arbitrary form of room shapes etc.) compared with existing methods

  • PDF

The temperature distributions of the curing space according to blocking the opening of gang-form at the apartment in the cold weather (동절기 공동주택 갱폼 개구부 천막보양에 따른 보양 온도 분포 분석)

  • Cho, Hong-Bum;Song, Jin-Hee;Kim, Young-Sun;Choi, Ji-Su;Lee, Kyu-Nam
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.140-141
    • /
    • 2022
  • CFD analysis was performed to analyze the temperature distribution of the inner space of the curing house according to blocking the opening of the gang-form with a tent in case of concrete pouring and heat curing of the apartment house during the winter season. If the gang-form opening is closed with a tent during internal heating using a hot air blower in the winter, the internal temperature rises compared to the non-reserved due to air-tightness of the curing spaces, and uniform temperature distribution can be ensured. In addition, it is possible to increase curing efficiency by reducing the amount of heat supplied and shortening the heating time.

  • PDF

Development of Uniform Press for Wafer Bonder (웨이퍼 본딩 장비용 Uniform Press 개발)

  • Lee, Chang-Woo;Ha, Tae-Ho;Lee, Jae-Hak;Kim, Seung-Man;Kim, Yong-Jin;Kim, Dong-Hoon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.4
    • /
    • pp.265-271
    • /
    • 2015
  • The bonding process should be achieved in vacuum environment to avoid air bubble. In this study, we studied about pressure uniformity that became an issue in thermo compression bonding usually. Uniform press is realized by the method that use air spring and metal form spring. The concept of uniform press using air spring is removed except pressing direction in the press processing so angle between the vector of pressure surface and the pressure axis is parallel automatically. Air spring compensate the errors of machining and assembly. Metal form compensate the thermal deformation and flatness error.

The Study for the Air Bubble Deterioration of Combined High Flowing Self-Compacting Concrete (병용계 고유동 자기충전콘크리트의 기포저감을 위한 연구)

  • Choi, Yun-Wang;Kim, Kyung-Hwan;Ruy, Deug-Hyun;Jeong, Jae-Gwon;Kang, Hyun-Jin;Lee, Jae-Nam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.449-452
    • /
    • 2008
  • This study is to manufacture HSCC (High flowing Self-Compacting Concrete) be able to construction without vibration & hardening, and it is stable according to the change of the surface number of aggregate and to examine the factor of reduction occurred before after hardening through the indoor experiment. It is essential to use of the thickener to increase the viscosity in the combined HSCC. In this result, it make more bubbles than HSCC of pulverulent body. The result of study has shown, through the surface air bubble by not passed air bubbles within concrete after hardening, It has bad effect in not only appearance of structures but strength & duration. It is the experiment for air bubble of concrete according to the types of aggregate (fine aggregate), mixing time of concrete, exfoliation, material of model form and so that reduce the air bubble of combined HSCC. Experiments have shown, the effect of exfoliation was bigger than the effect of form for the performance of surface finishing of combined HSCC after hardening according to the exfoliation or material of model form and the opaque guris has good condition of finishing.

  • PDF

A Numerical Analysis on Flow Fields and Calculation of Pressure Resistance about an Air Supported Ship (수치시뮬레이션에 의한 공기부양선 주위의 유동장해석과 조파저항계산)

  • Na Y. I.;Lee Y. G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.43-48
    • /
    • 1995
  • A numerical computation is carried out to analyse characteristics of flow fields around Air Supported Ships having arbitrary form. The computations are performed in a rectangular grid system with MAC(Marker And Cell) method. The governing equations are represented in a Finite Difference form by forward differencing in time and centered differencing in space except for convection terms. For validation of this numerical analysis method, the computation of flow fields around Catamaran and ACV(Air Cushion Vehicle) with pressure distribution on free surface are done, and that around Surface Effect Ship is also carried out. The results of the computations are compared with the those of existed numerical computation and experimental results with the same condition.

  • PDF

Characteristics of Sparkover Discharge in Flowing Air with Reynolds Numbers' Variable (Reynolds Number를 변수(變數)로한 유동공기(流動空氣)의 방전특성(放電特性)에 관한 연구)

  • Kim, Y.H.;Oh, J.Y.;Lee, K.S.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.286-288
    • /
    • 1990
  • This paper reports the characteristics of sparkover discharge in flowing air ranging from 0[m/s] to 30 [m/s] under the needle-needle gap. Flowing air duct of this investigation is circular tube. The important results obtained form this study are as follows. 1. the ratio of sparkover voltage to the Reynolds number decreases with increasing the Reynolds number. 2. The duration time of sparkover(t) decreases with increasing the Reynolds number. 3. the empirical equation obtained form this experiment is [ %]${\frac{Vs}{Re}}$ = A + $B{\varepsilon}^{C.Re}$ where A = 10.2 b = 125 c = -4.66 ${\times}$ $10^{-5}$

  • PDF