• Title/Summary/Keyword: air flotation

Search Result 130, Processing Time 0.017 seconds

Development of Dissolved Air Flotation Technology from 1st Generation to the Newest or 3rd One (Very Thick Microbubble Bed) with High Flowrates DAF in Turbulent Flow Conditions (차세대 고효율 용존공기 부상공정(High Rate DAF)의 개발)

  • Kiuru, H.J.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.228-234
    • /
    • 2004
  • Dissolved air flotation (DAF), in which suspended solids are removed from water by means of micro-size air bubbles raising slowly up in water and lifting solids from water (smaller than those) attached onto the micro-bubbles as well as those (larger than solids) being attached on these, have been used in water and wastewater since 1920s. The dissolved air flotation technology was originally based on the laminar flow conditions prevailing in water to be treated, but the latest development in that technology has led now to a situation, in which the flow conditions may also be turbulent ones in the modem dissolved air flotation units. Despite of that, the flotation phenomenon used in this unit operation for removal suspended solids from water or wastewater is still the same.

Thickening Characteristics of Activated Sludge by Air Flotation Process (공기부상법을 이용한 활성슬러지의 부상분리 특성)

  • Park, Chanhyuk;Hong, Seok-won;Maeng, Juwon;Lee, Sanghyup;Choi, Yong-su;Moon, Seong-yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.747-753
    • /
    • 2006
  • Air flotation is a solid-liquid separation process that utilizes up-flow microbubbles to thicken activated sludge and enhance clarification efficiency. Continuous air flotation experiments were performed to investigate the effect of operation parameters such as initial MLSS (mixed liquor suspended solid) concentration, air pressure, surface loading rate, air to solid (A/S) ratio, and flotation time on thickening efficiency. An initial activated sludge concentration ranged from 3,000 to 12,000mgSS/L and thickened sludge concentration varied from 6,400 to 28,100mgSS/L. The result showed that the thickening efficiency was mainly dependent on surface loading rate, A/S ratio, and flotation time. The pressure did not affect the thickening efficiency when it kept in the range of 1.6 to 1.8 bar. Experimental results showed that the thickening efficiency of activated sludge was increased only when the feed sludge concentration exceeded 5,000mgSS/L and the thickened concentration was over 20,000mgSS/L. At this time, SS concentration in the clarified liquid was ranged from 5 to 10mg/L.

Effects of Blade Configuration on the Performance of Induced Gas Flotation Machine (익형 변화에 따른 유도공기부상기 성능특성 연구)

  • Song, You-Joon;Lee, Ji-Gu;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.41-46
    • /
    • 2017
  • The flotation performance of the induced gas flotation (IGF) machine is considerably influenced by geometric configurations of rotor and stator. The interaction of rotor and stator, which are the most important components in IGF, serves to mix the air bubbles. Thus, the understanding of flow characteristics and consequential analysis on the machine are essential for the optimal design of IGF. In this study, two-phase (water and air) flow characteristics in the forced-air mechanically stirred Dorr-Oliver flotation cell was investigated using ANSYS CFX. In addition, the void fraction and the velocity distributions are determined and presented with different blade configurations.

Coagulation and Flotation Conditions of Humic Acid by Dissolved Air Flotation

  • Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1043-1051
    • /
    • 2012
  • Coagulation, flocculation, and dissolved air flotation (DAF) experiments were performed with humic acid to evaluate the influence of operational conditions on removal efficiencies. We investigated coagulation, flocculation, and flotation conditions of humic acid removal using a laboratory-scale DAF system. This paper deals with coagulant type (aluminum sulfate and PSO-M) and the most relevant operational conditions (velocity gradients for coagulation and flocculation, retention time and recycle ratio and flotation time). Results showed that optimal conditions for removing humic acid, yielding CHA removal efficiencies of approximately 85 %, are a recycle ratio of 40 %, coagulant dosages of 0.15 - 0.20 gAl/gHA as aluminum sulfate and 0.03 - 0.12 gAl/gHA as PSO-M, coagulation($400s^{-1}$ and 60s), flocculation($60s^{-1}$ and 900s or more), and flotation(490 kPa or more and at least 10 min).

The Study on the Humic Acid Removal using Underwater Plasma Discharge (수중 방전을 이용한 휴믹산 제거)

  • Hong, Eunjung;Chung, Paulgene;Ryu, Seungmin;Park, Junseuk;Yoo, Seungryul;Lho, Taihyeop
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.367-374
    • /
    • 2012
  • A flotation process has a shorter processing time and needs less space than a sedimentation process. Dissolved air flotation process (DAF) is an efficient flotation method and used in a conventional wastewater treatment process. However, DAF requires the circulation of water containing compressed air and requires expensive installation and operation cost. Plasma Air Flotation (PAF) process is able to float flocs by micro bubbles generated from underwater plasma without the circulation of bubbly water and additional saturators. Therefore, PAF can be an alternative solution overcoming economic barriers. In this study, Humic acid removal efficiency by PAF process was compared with that of sedimentation process. 44.67% and 87.3% reduction rate based on UV 254 absorbance has been measured in sedimentation and PAF respectively. In particular, PAF in the flocculation zone can dramatically remove humic acid from water. In flocculation zone, PAF can separate organic matters but sedimentation cannot.

Effect of Sludge Characteristics on the Thickening of Bulking Sludge using DAF (Dissolved Air Flotation) (슬러지의 성상이 DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축에 미치는 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • Excess sludge treatment and disposal currently represent a rising challenge for domestic or wastewater treatment plants due to economic, environmental and regulation factors. Conventional gravity sedimentation process has been widely used in sludge thickening. The operation method of the process is very simple, but the process requires long detention time for sludge thickening, uses polymers, and shows low sludge thickening efficiency. To solve the problems, we studied on DAF (Dissolved Air Flotation) system. We use bulking sludge of a paper manufacturing plant. The effects of parameters such as SVI (Sludge Volume Index), storage time, initial concentration and wet density of excess sludge were examined. The results showed that the more SVI was low, the more sludge was thickened. As storage time goes by, SVI was increased and thickening performance was deteriorated. In order to improve flotation performance at high concentration, high recycling ratio and pressure did not increase the concentration due to thickening limitation. The addition of 0.8 g/L of loess was increased flotation efficiency of 1.41 times.

Flotation Characteristics of Activated Sludge by Micro-bubbles (미세 기포에 의한 활성슬러지의 부상특성)

  • Kim, Seong-Jin;Kang, Byoung-Jun;Park, Sang-Wook;Lee, Jae-Wook;Jung, Heung-Joe;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.501-507
    • /
    • 2006
  • Dissolved air flotation (DAF) has been well known for the gravity separation process. The solids to be separated are transferred from the water body to the water surface using micro-air bubbles. DAF has also been used for enhancing solids-liquid separation of industrial and municipal wastewater by adding a its unit parallel to a sedimentation unit to reduce the hydraulic loading in the sedimentation clarifier. This study was to investigate flotation characteristics of activated sludge by the recent DAF technique without chemical agents. In addition, the effect on temperature in flotation of activated sludge and the thickening degree of activated sludge were studied.

COD, SS and Turbidity Removal of Paper Wastewater Using DAE(Dissolved Air Flotation) (DAF(Dissolved Air Flotation)를 이용한 제지폐수의 COD, SS 및 탁도 제거)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.246-253
    • /
    • 2005
  • The supernatant treatment of recovery process of raw materials of paper plant was studied using DAF (Dissolved Air Flotation) system. We investigated the removal efficiency (COD, SS and turbidity) of the DAF process. The effects of parameters such as A/S ratio, pressure, flotation conditions, coagulant concentration, mixing conditions, size and ratio of packing and nozzle type were examined. The results showed that the optimum A/S ratio and pressure were 0.058 and 4.5-5 atm, respectively. Injection times of pressurized water around 30 s and flotation times around 10 min appeared to be optimal for the DAF operation. Anion polymer addition improved the removal of COD, SS and turbidity. The smaller size and the more packing ratio were enhanced the removal efficiencies. The order of performance of nozzle was full cone > flat > assemble type.

Simulation study of DAF flotation basin using CFD (전산유체해석기법을 이용한 용존공기부상공정의 유동해석)

  • Park, Byungsung;Woo, Sungwoo;Park, Sungwon;Min, Jinhee;Lee, Woonyoung;You, Sunam;Jun, Gabjin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.261-272
    • /
    • 2013
  • Algae boom (Red tide) in south coastal area of Korea has been appeared several times during a decade. If algae boom appears in the desalination plant, media filter and UF filter are clogged quickly, and the plant should be shutdown. In general, Algae can be removed from water by flotation better than by sedimentation, because of the low density of algal cell. The purpose of this study conducts the CFD simulation of DAF flotation basin to apply the design of the dissolved air flotation with ball filter in the Test Bed for SWRO desalination plant. In this study, Eulerian-Eulerian multiphase model was applied to simulate the behavior of air bubbles and seawater. Density difference model and gravity were used. But de-sludge process and mass transfer between air bubbles and seawater were ignored. Main parameter is hydraulic loading rate which is varied from 20 m/hr to 27.5 m/hr. Geometry of flotation basin were changed to improve the DAF performance. According to the result of this study, the increase of hydraulic loading rate causes that the flow in the separation basin is widely affected and the concentration of air is increased. The flow pattern in the contact zone of flotation basin is greatly affected by the location of nozzle header. When the nozzle header was installed not the bottom of the contact zone but the above, the opportunity of contact between influent and recycle flow was increased.

Thickening of Bulking Sludge using DAF (Dissolved Air Flotation) (DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축)

  • Kim Dong-Seog;Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.77-84
    • /
    • 2006
  • An effective technique of sludge separation is required for excess sludge of sewage or wastewater plant. The separation of bulking sludge of paper manufacturing plant was studied using DAF(Dissolved Air Flotation) system. The effects of parameters such as nozzle type, A/S(air/solid) ratio. pressure, injection time of pressured water and saturation time were examined. The results showed that the best nozzle type was flat which had small orifice hole, The optimum A/S ratio and pressure were $7.070\times10^{-3}$(recycle ratio of pressured water $20\%$) and 5atm, respectively. Injection times of pressurized water around 20-25 sesc and flotation time of 30 min appeared to be optimal for the DAF operation. The order of performance of packing was 18 mm > 22 mm > 32 mm.