• 제목/요약/키워드: aging time and humidity

검색결과 32건 처리시간 0.026초

22kV 전력케이블의 열화 판정에 관한 연구 (A Study on the Remain Life with Aging in 22kV CV cable)

  • 이관우;목영수;김보경;박복기;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.19-21
    • /
    • 2003
  • In this paper, we studied on life-decision of underground cable of live-lines state. As all equipments have been wear, underground cables decided design-life on the whole 30 years because underground cable have been occurred aging as time goes. CV cable has been become about 30 years after installation in the South Korea, is come to a important point of time with estimation about life. Study target cable is 22 kV CV cables in this point of view and installation cable is about 10 years before and behind. Measurement method used dc leakage method of live-lines state that applied voltage of 50V in neutral point and data is analyzing result that is measured during 5 years. In this result, insulation resistance could confirm that change according to season and cause is effect of humidity, seasons and load current. Also, according as data is gone aging, insulation resistance by Weibull distribution could confirm functionally its decrease. As a result, the aging speed of cable that water tree is gone could confirm fastness very. Numerical analysis result, cable that water tree is not gone could confirm that life of cable that has passed 10 years remains about $10{\sim}20$ years.

  • PDF

고무-스틸 코드 접착력과 타이어 내구력에 미치는 노화의 영향 (Effect of Aging on Adhesive Strength of Rubber-steel Cord Composite and Tire-endurance)

  • 임원우
    • 접착 및 계면
    • /
    • 제3권2호
    • /
    • pp.40-44
    • /
    • 2002
  • 본 실험에서는 고무-황동 도금 스틸 코드 복합체의 접착성에 미치는 미가류 복합체의 방치 기간과 가류 복합체의 열노화의 영향을 검토하였다. 또한 이런 방치 조건에 따른 접착력 변화가 타이어 내구력에 어떤 영향을 미치는지를 평가하였다. PAD 접착 시편을 사용하여 박리 접착 강도를 측정하였다. 미가류 복합체의 방치 기간은 공장 조건에서 최대 35일이고 가류 복합체의 열노화는 $85^{\circ}C$ 항온조에서 5, 10일간 실시하였다. 박리 접착 강도는 방치일수가 길수록 하락하는 경향을 보였다. 또한 열노화 기간이 길수록 그 값은 낮았다. 박리 접착 강도가 낮을수록 타이어 내구력도 낮았고, 그 주된 원인이 수분과 열에 의한 노화가 고무와 스틸 코드의 접착력을 하락시켜 코드와 고무의 계면에서 파괴가 일어났기 때문이라는 것을 SEM관찰과 내구력 평가로 확인할 수 있었다. 즉, 스틸 코드 표면의 부식이나 접착증의 노화가 접착강도 하락에 크게 영향을 미치고 그 결과 타이어의 내구력 하락에도 직접적인 영향을 미친다는 것을 알 수 있었다.

  • PDF

숙성 조건 변화에 의한 흑마늘의 이화학적 특성변화 (Changes in Physicochemical Properties and by the Aging Conditions of Garlic)

  • 서보영
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.21-26
    • /
    • 2022
  • When garlic is aged for a certain period of time while maintaining proper humidity, it causes a browning reaction by its own ingredients and enzymes. In this study, the physicochemical properties were analyzed by varying the temperature conditions for aging garlic. It was found that about 20% of the weight of garlic was reduced through the aging process. During the aging process, both samples showed the highest water content on the 10th day of aging, and the water content of the two samples was similar after the aging was completed. In the analysis of total sugar content change, AG1 (22.0±0.7 vs 21.4±0.6) showed a significantly higher sugar content on the 10th day of aging, but showed a tendency to gradually decrease thereafter, whereas AG2 showed a steady increase in sugar content during the aging process (18.7 < 21.4 < 21.7 < 22.3 < 23.7). The pH change that occurred during the aging process showed the most pH change on the 10th day. In AG1, the pH gradually decreased as the aging period increased, whereas in AG2, the pH increased significantly after the 10th day. In the analysis of browning, AG1 increased sharply on the 10th day and maintained the state, and AG2 showed a significant increase in browning according to the aging process. In conclusion, based on the results of this study, if various ripening temperature conditions are set, it is judged that it will play a positive role in improving the productivity of black garlic.

시설원예용 스마트 환경 제어 시스템 (Smart Control System for Greenhouse Environment)

  • 김응곤
    • 한국전자통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.907-914
    • /
    • 2017
  • 최근 전 세계적으로 농작물에 대한 스마트 팜 기술의 발달로 산업화, 자동화가 이루어지고 있다. 이는 인구의 고령화와 노동력 감소에 대한 농업시스템의 자동화와 편리성이 필요하기 때문이다. 본 논문에서 제안한 스마트 통합 제어 시스템은 일반농가들이 편리하게 관리할 수 있는 앱을 통해 스마트폰에서 온습도 조절을 실시간으로 확인 가능하며 최적의 온습도를 유지함으로써 병충해 예방과 농작물 성장에 도움을 주며, 농어민의 노동력과 생산성 향상이 가능하다.

온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가 (Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280))

  • 류찬주;김정아;김준수;윤근영;허승희;홍성종
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography)장치는 해부학적 정보를 얻기 위한 CT와 MRI의 장치를 PET 장치와 융합시킨 PET/CT나 PET/MRI 장치로 사용된다. 그렇기 때문에 일반 의료장비들과 비교하여 Gantry(촬영부 본체)의 길이가 늘어나고 내부의 공간이 넓어지는 원형(ring)타입의 구조로 제작된다. PET 장치의 구성요소 중 하나인 신틸레이터는 Gantry 안쪽에 위치하는데 온·습도 변화에 민감한 크리스탈 성분으로 되어있기 때문에 커다란 온도 변화로 인해 신틸레이터의 손상을 가져올 수 있다. 신틸레이터는 항온항습기로 PET장치가 설치되어 있는 공간에 온·습도를 유지하지만 이러한 PET 장치의 구조적 원인과 CT 장비에서 발생하는 열로 인한 Gantry 내부의 온·습도의 변화가 예상된다. 항온항습기를 가동하여 온·습도를 유지중인 PET/CT 장치의 Gantry 내부를 6개의 구역으로 나눈 후 각 구역에 Arduino 온·습도 센서인 Adafruit BME 280을 부착하여 출력 값을 분석했다. 각 6개 구역에서 센서를 이용해 측정한 평균 온·습도 값과 항온항습기의 평균 측정값을 비교하면 평균적으로 온도는 2.71℃ 상승, 습도는 21.5% 감소의 차이가 발생하였고, PET Gantry의 온·습도 측정값은 국내에서 지정한 정도 관리 범위에서 벗어나는 결과 값이 나왔다. 연구 결과를 통해 앞으로 지속적인 온·습도의 변화를 가진다면 PET Gantry 안에 장착된 신틸레이터의 노후화가 예상되므로 Gantry구조 내부의 온·습도를 적절히 유지하는 방안을 모색해야 한다.

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

Diversity and Characteristics of the Meat Microbiological Community on Dry Aged Beef

  • Ryu, Sangdon;Park, Mi Ri;Maburutse, Brighton E.;Lee, Woong Ji;Park, Dong-Jun;Cho, Soohyun;Hwang, Inho;Oh, Sangnam;Kim, Younghoon
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권1호
    • /
    • pp.105-108
    • /
    • 2018
  • Beef was dry aged for 40-60 days under controlled environmental conditions in a refrigerated room with a relative humidity of 75%-80% and air-flow. To date, there is little information on the microbial diversity and characteristics of dry aged beef. In this study, we explored the effect of change in meat microorganisms on dry aged beef. Initially, the total bacteria and LAB were significantly increased for 50 days during all dry aging periods. There was an absence of representative foodborne pathogens as well as coliforms. Interestingly, fungi including yeast and mold that possess specific features were observed during the dry aging period. The 5.8S rRNA sequencing results showed that potentially harmful yeasts/molds (Candida sp., Cladosporium sp., Rhodotorula sp.) were present at the initial point of dry aging and they disappeared with increasing dry aging time. Interestingly, Penicillium camemberti and Debaryomyces hansenii used for cheese manufacturing were observed with an increase in the dry aging period. Taken together, our results showed that the change in microorganisms exerts an influence on the quality and safety of dry aged beef, and our study identified that fungi may play an important role in the palatability and flavor development of dry aged beef.

황색종 잎담배의 발효숙성 촉진에 관한 종합적 연구 (A Comprehensive Study on the Forced Aging of Flue-cured Tobacco-Leaves)

  • 배효원
    • Applied Biological Chemistry
    • /
    • 제13권1호
    • /
    • pp.1-27
    • /
    • 1970
  • 황색종 잎담배의 인공발효숙성은 효모처리에 의한 인공발효, 단순한 인공숙성, 2년 저장숙성 및 미처리구로 나누어 미생물학, 물리학, 화학, 생화학적으로 그 변화과정을 종합적으로 연구하여 다음과 같은 결과를 얻었다. 1. 한국산 잎담배 Y.S.A의 발호숙성을 촉진시키는 최적 조건으로서는 및 담배를 온도 $40^{\circ}C$평형함수율 18%, 관계습도 74%에 놓아두는 것이 잎담배의 모든 품질적 특성에 가장 양호한 결과를 주는 것임을 알게되었다. 2. 잎담배를 $40^{\circ}C$의 숙성온도 및 74%의 상대습도에서 효모를 첨가하여 약 20일 내외에서 숙성을 촉진시켜 숙성시키면 잎담배의 여러가지 물리적 및 화학적 특성이 1년 및 2년 저장숙성시킨 것과 비슷하게 됨을 알게 되었음으로 그 실용적 효과를 입증할 수 있었다. 3. 온도 $40^{\circ}C$와 평형함수율 18%의 숙성조건하에서 잎담배에 효모를 첨가하여 또는 단순히 조기숙성시켰을 때 잎담배는 그 숙성에 필요한 물리화학적 특성은 약 20일만에 얻을 수 있다는 것을 알게되었다. 4, 본 실험에서 잎담배의 발효숙성기간중 미생물의 동태는 효모와 세균은 15일까지 증가하였다가 감소하였고 곰팡이류는 끝까지 계속 증가하였다. 5, 효모구 및 속성구 잎담배의 이화학성은 발효숙성이 $15{\sim}20$일 진행함에 따라 pH는 저하하였고 팽승성과 연소성이 양호하여 졌고 자극순도, 명도주재파장등 색택에 관련되는 물리성이 2년저장 잎담배와 비등하여졌다. 또 총환원성물질, 전당, 전환원당, 알카로이드량은 감소하였고 유기산, ether 추출물은 증가, 전질소 및 단백질량, 조섬유, 회분등은 별 변화가 없었다. 6. 효모 및 속성구의 잎담배는 발효숙성이 15-30일 진행되는 동안 그 개개의 화학성분이 다음과 같이 변화하였다. 즉, 시일이 경과함에 따라 당 류-sucrose, rhamnose, glucose 색소류-chlorophyll, carotenes, xanthophyll, violaxanthine polyphenols-rutin, chlorogenic 및 caffeic acid 유기산-iso?tutylic, crotonic, capronic, galacturonic,tartaric, succinic, citric acid 알카로이드-nicotine,nornicotine등 화합물은 감소하였다. 한편 시일이 경과함에 따라 당 류-fructose, maltose, raffnose 아미노산-proline, cystine, 유 기 산-formic, acetic, propionic, malic, oxalic,malonic, α-ketoglutaric, fumaric, glutaric acid 등 화합물은 증가하였다. 7. 잎담배 발효숙성중 생화학적 특성의 변화는 다음과 같았다. 즉, 30일간의 발효숙성기간중 산소흡수량은 점차 감소하였으며, ${\alpha}-amylase$ ${\beta}-amylase$}활성도는 점차 약하여 졌으나 catalase, invertase는 그 활성도가 일단 숙성중기에 높아졌다가 낮아졌다.

  • PDF

대두유전자원의 안전보존을 위한 계통간 발아수명검정 (Storability of Soybean Lines for Maintanance of Germplasm)

  • 권신한;한영희;이영일
    • 한국작물학회지
    • /
    • 제29권3호
    • /
    • pp.275-279
    • /
    • 1984
  • 대두유전자원의 안전보존을 위해서 50계통을 선정하고 온도 23$^{\circ}C$와 습도 60%가 넘지 않도록 유지시킬 수 있는 본 연구소의 저장고에 종자를 저장하면서 계속 일정 간격으로 발아력을 조사하는 한편 동일 계통의 종자를 온도 4$0^{\circ}C$와 습도 90%에서 인공적으로 노화촉진시켜 저장고에서의 발아력감퇴와 비교하였다. 저장초기의 평균발아율이 97%이었는데 반해 저장 42개월에는 62%로 저하되었는데 비교적 본 저장고에서 오랫동안 발아력이 유지된 셈이다. 종자의 크기와 종피색에 따라 발아력 유지의 정도에 차이가 있는 것으로 나타났는데 대립보다 소립 또한 갈색이나 녹색보다 검정색이나 황색 계통에서 발아력 유지가 오래 지속되는 경향을 보였다. 인공노화촉진처리한 후의 계통간 발아력감퇴차이는 저장고에서의 것과 일치하는 것으로 나타났고, 특히 저장전에 계통간 종자 수명을 파악코저 할 때, 온도 4$0^{\circ}C$와 습도 90%에서 7일 처리가 가장 알맞는 것으로 사료된다.

  • PDF

가속노화 시험을 통한 진공단열패널(VIP)의 장기성능 평가 연구 (The Study of Long-Term Performance Evaluation of Vacuum Insulation Panel(VIP) with Accelerated Aging Test)

  • 김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제37권4호
    • /
    • pp.35-47
    • /
    • 2017
  • Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP) is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been applied in buildings for over a decade, it wasn't until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing of VIP. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot box method) and long-term durability was estimated based on a non-linear pressure-humidity dependent equation based on study of IEA/ECBCS Annex 39, with the aim of assessing durability of VIP for use in buildings. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90 % for the thermal conductivity (${\lambda}90/90$) ranged from 0.00726-0.00814 (W/m K) for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.