• Title/Summary/Keyword: adjustable

Search Result 846, Processing Time 0.028 seconds

A Study on the Design of Rotary Mower and Its Utilization. (Rotary Mower의 제작과 그 이용에 관한 연구)

  • 최규홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3897-3920
    • /
    • 1975
  • Since the most of Korean dairy and cattle raising farms are too small to introduce western mechanized farming, it is necessary to develope small size equipments. This study has been carried to develop a rotary mower as on attachment of 8 to 10 horse powertiller which is widely spread in rural area. It will not ony be helpfull for the farmers to harvesting hay grass but also desirable to increase the power tiller utility. The protto type rotary mower designed through the fundamental investigations, has been modified and improved through the field trials, and a series of field tests has been carried to investigate its performance and economic feasibility comparing with existing vailable harvesting equipments. The results are as follows; 1. To increase the stability, two guide wheels are attached to both side of the protto type rotary mower. 2. To prevent the clinging of tall grasses, the vertical driving shafts are covered with cylindrical protectors. 3. The cutting height is adjustable in 8 steps from 2.5 to 20 centimeters by changing the length of guide wheel legs. 4. The practical Critical cutting speed were always higher than theoretical value in both case of single cutting blade and three when the cutting depth was 25 millimeter. 5. The peripheral speed of cutting blade was varied in response to the change of engine speed, mean while the peripheral speed was adequate as it was changhed from 25 to 35 meter per second when the power tiller is operated in proper working ground speed. 6. The time requirement to harvest 10 a were 88.7, 54.6 and 41.4 minutes for the first, second and third stage of ground speed respectively, and because of the difficulty of delivery, it was observed that operating with fourth stage of ground speed was not recomanendable when the grass height is taller than 90 centimeters. 7. The performance of rotary mower were 1.1-1.7, 1.4-4.0, 3.8-11.8 and 7.4-22.0 times of reciprocating mower, portable disc type cutter, hay scythe and ordinary sickle respectively. 8. When the slope exceeds, 20 degree the downward harvesting operation was impossible because of the excessive front end weight, while less than 5 degree of land slope did not effect in field operation. 9. Increased traveling spee caused higher cutting height and slight cutting failure, but seems not to effect to the gross yield, and the efficiency of cutting width were from 83 to 94 precent. 10. Tn rank of economy were rotary mower (3,2 stage operation), reciprocating mower, hay scythe, portable disc type cutter and sickle in order when the annul operation exdeeds 100 hours. From the above results, it is convinced that the protto type rotary mower is good enough to the livestock farmers as a hay harvesting equipment because of its economy, hardiness in operating and its out standing performance and hopefully it will contribute to the extension of Korean livestock farming.

  • PDF

The Study on Frameworks of Valuation Models for the Contents of Science and Technology Information (과학기술정보 콘텐츠의 가치평가모형 프레임워크 연구)

  • Sung, Tae-Eung;Jun, Seung-Pyo;Byun, Jeongeun;Park, Hyun-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.421-433
    • /
    • 2016
  • Recently, although the interest in transfer and transactions of intangible assets increases, there is no valuation model to objectively assess market value of knowledge and information contents such as electronic databases and the necessity of researches associated is brought up. Therefore, the present study proposes valuation models so as to utilize as objective reference information in the contents market of intangible assets, by assessing the market value of science and technology information contents including patents, academic papers and reports. First, we look into application methods of calculating cash flows by content types out of key variables which has been applied to the present technology valuation, and in case of patents we propose valuation methods based on concepts which are applied in the present technology valuation. Next, in case of both papers and reports, in order to reflect the characteristics of these contents we newly propose qualitative valuation methods which are adjustable based on both technology innovation and market demands indices while estimating the economic life cycle of the technology, and also present the input cost-based calculation method as the calculation method of cash flows. Throughout the study, we could establish frameworks by technology fields and business models applicable such as copyright licensing, transactions of individual science and technology information contents, and expect that more objective and reasonable assessment of content values is accessible.

Implementation on SVM based Step Detection Analyzer (SVM 기반의 걸음 검출 분석기의 구현)

  • An, Kyung Ho;Kim, En Tae;Ryu, Uk Jae;Chang, Yun Seok
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.10
    • /
    • pp.1147-1155
    • /
    • 2013
  • In this study, we designed and implemented a step detection analyzer that can compare and analyze the step detection rates and results among the step detection algorithms. The step detection analyzer converts 3-axes accelerometer data into continuous energy stream through SVM operation, shows the horizontal comparison among the step detection results for each step detection algorithms, and can make elemental detection analyses. For these processes, the step detection analyzer presents the continuous energy stream as energy waveform, checks the peak values and time location of the detected steps with step detection algorithms, and gives visual interface to get some possible causes in cases of step detection miss. It can also give the threshold graph for each algorithm to check the threshold value on missed cases directly and can help to get more appropriate threshold values or other adjustable parameters in step detection algorithm. This step detection analyzer can be applied efficiently on performance enhancement of step detection algorithm, on deciding an appropriate algorithm for a specific step counter system in the various step counter filed operations.

Electromyographic Analysis of a Uphill Propulsion of a Bicycle by Forward.Backward Pedaling (정.역구동 페달링에 따른 자전거 등판 시의 근전도 분석)

  • Shin, Eung-Soo;Kim, Hyun-Joong
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.171-177
    • /
    • 2008
  • This work intends to investigate the effects of pedaling directions on the muscle actions during the bicycle's uphill propulsion. A test rig was developed that consists of a bicyle with a special planetary geartrain, a height-adjustable treadmill, a rear-wheel support and a magnetic brake. A three-dimensional motion analysis was performed for measuring kinematic characteristics of the forward backward pedaling and the electromygraphy(EMG) measurements were simultaneously performed for estimating the muscle actions of the leg. In this work, four muscles are considered including Gastrocnemius muscle(GM), Vastus lateralis(VL), Tibialis anterior(TA) and Soleus(SOL) while the uphill slope is varied from $0^{\circ}$ to $6^{\circ}$. Raw EMG signals were first processed through the root-mean-square(RMS) averaging and then ensemble curves were derived by averaging the EMG RMS envelopes over 50 consecutive cycles. Results show that both the kinemactic characteristics and the muscle actions are significantly affected by the pedaling direction. The crank speed of the forward pedaling is higher but the difference in speed is reduced as the slope is increased. The ensemble curves of the :ac signals clearly exhibit some differences in their patterns, peak values and the corresponding locations with respect to the crank angle. The peak values of most EMG signals are higher for the forward pedaling regardless of the slope magnitude. However, the averages of the EMG signals are not observed to have a similar relationship with the pedaling direction, which seems to be affected by several factors such as less experience of the participants' backward pedaling. inappropriate bicycle design for the backward pedaling. These limitations will be further considered in future work.

Application of Diffusion Models to Anomalous Sorption in Fluoropolymer-aromatic Solvent Systems (불소고분자-방향족 용매계의 비이상적 흡수에 대한 확산 모델식의 적용)

  • 이상화
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.139-147
    • /
    • 2000
  • Non-Fickian (or anomalous) diffusion was observed in transient sorption of aromatic solvents(such as benzene, toluene, and chlorobenzene) in fluoropolymers (such as ETFE, ECTFE and PVDF). In this study, five other transient sorption models (Crank, Long & Richman, Berens & Hopfenberg, Neogi, Li) based on Fick's law were employed to fit the anomalous sorption data for aromatic solvents. The adjustable parameters were determined by least square analysis of the measured and predicted fractional uptake. For ETFE sorption data slightly deviating from Fickian behavior, all the models exhibited satisfactory results in fitting the anomalous sorption data. In particular, Neogj model predicted intrinsic diffusivity (0.4~0.8$\times$10$^{-5}$ $\textrm{cm}^2$/day) and equilibrium diffusivity (0.13~0.31$\times$10$^{-4}$ $\textrm{cm}^2$/day) as well as relaxation kinetics related to non-Fickain diffusion. For a typical sigmoidal sorption behavior in PVDF, only Crank's model could give the reasonable evaluation on transport properties. The ratio of intial diffusivity (D$_{i}$) to final equilibrium diffusivity (D$_{\infty}$) was ranged from 80 to 200. For the final stage of uptake In ECTFE with drastic acceleration, all the models exhibited significant deviations from the sorption data. New diffusion models based on thermodynamics and continuum mechanics should be employed to get valuable information on transport properties as well as relaxation kinetics coupled with non-Fickian diffusion.

  • PDF

Group Delay Time Matched CMOS Microwave Frequency Doubler (군지연 시간 정합 CMOS 마이크로파 주파수 체배기)

  • Song, Kyung-Ju;Kim, Seung-Gyun;Choi, Heung-Jae;Jeong, Yong-Chae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.7
    • /
    • pp.771-777
    • /
    • 2008
  • In this paper, a frequency doubler using modified time-delay technique is proposed. A voltage controlled delay line (VCDL) in the proposed frequency doubler compensates the group delay time mismatching between input and delayed signal. With the group delay time matching and waveform shaping using the adjustable Schmitt triggers, the unwanted fundamental component($f_0$) and the higher order harmonics such as third and fourth are diminished excellently. In result, only the doubled frequency component($2f_0$) appears dominantly at the output port. The frequency doubler is designed at 1.15 GHz of $f_0$ and fabricated with TSMC $0.18\;{\mu}m$ CMOS process. The measured output power at $2f_0$ is 2.67 dBm when the input power is 0 dBm. The obtained suppression ratio of $f_0,\;3f_0$, and $4f_0$ to $2f_0$ are 43.65, 38.65 and 35.59 dB, respectively.

Study on the Smart 1RM System Development and Effect Verification for Health Improvement and Management of National Healthcare (국민 건강관리 및 체력증진을 위한 스마트 1RM 시스템 개발 및 효과 검증에 관한 연구)

  • Woo, Kyung-Min;Shin, Mi-Yeon;Yu, Chang-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.12 no.1
    • /
    • pp.53-62
    • /
    • 2018
  • In this study, we developed a smart 1RM system for national health management and physical fitness, which enables quantitative 1RM measurement in various types of exercise using digital pulley technology, and to test the effect on training by using it. We developed the smart 1RM system, which is composed of portable muscle strength measuring device, Bluetooth communication based mobile phone data transmission and circuit diagram, and height adjustable system body. We recruited the 30 participants with 20th aged and divided into training and non-performing groups with 15 participants randomly. The participants performed 5 sets of elbow, lumbar, knee extension / flexion 10 times using smart 1RM system and the experimental period was 3 days a week for a total of 8 weeks. The experimental results showed that the maximum strength of the elbow, lumbar, and knee joints was significantly improved before and after maximal muscle strength training in the training group. Oxygen intakes during 1RM exercise mode showed 10.91% than endurance. To verify the validity of the smart 1RM maximal strength data, the reliability was 0.895 (* p <0.00). This study can be applied to the early rehabilitation treatment of the elderly and rehabilitation patients more quantitatively using the national health care.

Design of Smart Platform based on Image Recognition for Lifelog (라이프로그용 영상인식 기반의 스마트 플랫폼 설계)

  • Choi, Youngho
    • Journal of Internet Computing and Services
    • /
    • v.18 no.1
    • /
    • pp.51-55
    • /
    • 2017
  • In this paper, we designed a LBS-based smart platform for Lifelog service that can utilize the other's lifelog information. The conventional Lifelog service means that the system records the daily activities of the smart device user so the user can retrieve the early-recorded information later. The proposed Lifelog service platform uses the GPS/UFID location information and the various information extracted from the image as the lifelog data. Further, the proposed Lifelog platform using DB can provide the user with the Lifelog data recorded by the other service user. The system usually provide the other's Lifelog data within the 500m distance from the user and the range of distance can be adjustable. The proposed smart platform based on image recognition for Lifelog can acquire the image from the smart device directly and perform the various image recognition processing to produce the useful image attributes. And it can store the location information, image data, image attributes and the relevant web informations on the database that can be retrieved by the other use's request. The attributes stored and managed in the image information database consist of the followings: Object ID, the image type, the capture time and the image GPS coordinates. The image type attribute has the following values: the mountain, the sea, the street, the front of building, the inside of building and the portrait. The captured image can be classified into the above image type by the pattern matching image processing techniques and the user's direct selection as well. In case of the portrait-attribute, we can choose the multiple sub-attribute values from the shirt, pant, dress and accessory sub-attributes. Managing the Lifelog data in the database, the system can provide the user with the useful additional services like a path finding to the location of the other service user's Lifelog data and information.

Analysis of the Radiation Patterns of Satellite SAR System with Active-Transponder (능동전파반사기를 이용한 위성 SAR 시스템 방사 패턴 분석)

  • Hwang, Ji-Hwan;Kweon, Soon-Koo;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1204-1211
    • /
    • 2012
  • Measurement and analysis results of the extracted radiation-patterns from the field-experiments which were conducted to acquire the generic technology for calibration and validation of the satellite SAR system(Synthetic Aperture Radar) are presented in this study. Prototype of active transponder is adjustable within maximum 63.1 dBsm of RCS (Radar Cross Section) and includes the receiving-function with external receiver. To increase an accuracy of these field experiments, we repetitively measured satellite SAR systems of the same operating mode(i.e., COSMO-SkyMed No. 2 & 3, hh-pol., strip-map himage mode, 3 m resolution). Then, the reliability of experimental results was cross-checked through analysis of the RCS of active transponder on SAR image. The property of azimuth radiation patterns of satellite SAR system extracted from them has $0.352^{\circ}$ of HPBW(half-power beamwidth), $0.691^{\circ}$ of FNBW(first-null beamwidth), and 11.17 dB of PSLR(peak to side lobe ratio), respectively.

Changes of the Electromyographic Activity by Head Posture and Cervical Spine Shape (두부자세와 경추형태에 따른 근활성의 변화에 관한 연구)

  • Ho-Chun Hwang;Kyung-Soo Han;Chan Jung
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.393-405
    • /
    • 1996
  • This study was performed to investigate the effects of changes of head posture and cervical spine shape on the mandibular resting or clenching electromyographic(EMG) activity in anterior temporalis(TA), masseter(MM), sternocleidomastoid muscle(SCM) and trapezius insertion(TI). 30 patients with Temporomandibular Disorders(TMDs) participated in this study. EMG activity($\mu$V) at rest and clenching was observed in four head postures, namely natural head posture(NHP), forward head posture(FHP), upward head posture(UHP), and downward head posture(DHP). For taking in upward or downward head posture head was inclined 10$^{\circ}$ upward or downward and CROM$^\textregistered$(cervical-range-of motion, Performance attainment Inc., USA) was used to maintain same posture during the procedure, and BioEMG$^\textregistered$ (Bioelectromyograph, Bioresearch Inc., USA) was used to record EMG activity in the above four muscles at eight locations on both sides. The recorded EMG activity($\mu\textrm{V}$) were compared and analyzed by cervical spine shape such as the head position from plum line, cervical curvature, and cervical inclination. Head position from plum line was measured in vertical plate calibrated with cm scale, comical curvature by radius was measured with adjustable curved ruler, and cervical inclination by cervical vertebrae tangent(CVT)was measured in lateral cephalograph. The results obtained were as follows : 1. Mean value of head position from plum line, cervical curvature, and cervical inclination were 4.8cm, 26.7cm, and 86.6$^{\circ}$, respectively, And There were no correlationship among these items. 2. For resting EMG activity by head posture, the value in anterior temporalis was higher at FHP than at DHP, the value in masseter was higher at FHP than at NHP, and DHP, the value in sternocleidomastoid muscle was higher at UHP than at NHP, and the value in trapezius insertion was higher at FHP and DHP than, NHP and UHP. The clenching EMG activity, however, did not show any difference by head posture. 3. Comparison of resting and clenching EMG activity between higher and lower groups by head position from plum line, cervical curvature, and cervical inclination did not show any significant difference. From this result, the author concluded that the cervical spine shape had not significantly affected to EMG activity in usual patients with TMDs.

  • PDF