• Title/Summary/Keyword: address discharge

Search Result 179, Processing Time 0.026 seconds

Present Scenario and Future Prospects of Phytase in Aquafeed - Review -

  • Debnath, Dipesh;Sahu, N.P.;Pal, A.K.;Baruah, Kartik;Yengkokpam, Sona;Mukherjee, S.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.12
    • /
    • pp.1800-1812
    • /
    • 2005
  • Aquaculture pollution is a major concern among the entrepreneurs, farmers and researchers. Excess discharge of phosphorus and nitrogen into the water bodies is the principal pollutant responsible for this. Plant-based feed ingredients due to its high phytic acid content enhances both nitrogen and phosphorus discharge thereby increasing the pollution level. Dietary phytase treatment is probably the best answer to address this problem. This review explains the nature and properties of phytate, its interactions with other nutrients and the application of phytase in aquafeed to reduce the pollution. This review also covers the different biotechnological aspects for lowering the phytic acid level in the common aquafeed ingredients, as an alternate approach to controlling the pollution level. Some of future research needs have also been highlighted to attract the attention of more researchers to this area.

Research and Development of High Performance 42-inch XGA Plasma Display Panel

  • Choi, Kwang-Yeol;Min, Byoung-Kuk;Kim, Tae-Hyung;Song, Byung-Soo;Yoo, Eun-Ho;Kim, Jin-Young;Jung, Yun-Kwon;Kim, Won-Tae;Yang, Hee-Chan;Ryu, Jae-Hwa
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.231-235
    • /
    • 2004
  • High performance 42 inch XGA PDP with high luminance of 1,000 cd/$m^2$ has been developed using high efficient electrode structure, discharge gas and closed barrier ribs. For high speed addressing with single scan technique, address discharge time lag was reduced over 40% with FAST driving scheme and new materials. High dark room contrast ratio of 5,000 : 1 was achieved and picture quality was improved using new algorithm for eliminating false contour and improving gray level linearity.

  • PDF

A Separator with Activated Carbon Powder Layer to Enhance the Performance of Lithium-Sulfur Batteries

  • Vu, Duc-Luong;Lee, Jae-Won
    • Journal of Powder Materials
    • /
    • v.25 no.6
    • /
    • pp.466-474
    • /
    • 2018
  • The high theoretical energy density ($2600Wh\;kg^{-1}$) of Lithium-sulfur batteries and the high theoretical capacity of elemental sulfur ($1672mAh\;g^{-1}$) attract significant research attention. However, the poor electrical conductivity of sulfur and the polysulfide shuttle effect are chronic problems resulting in low sulfur utilization and poor cycling stability. In this study, we address these problems by coating a polyethylene separator with a layer of activated carbon powder. A lithium-sulfur cell containing the activated carbon powder-coated separator exhibits an initial specific discharge capacity of $1400mAh\;g^{-1}$ at 0.1 C, and retains 63% of the initial capacity after 100 cycles at 0.2 C, whereas the equivalent cell with a bare separator exhibits a $1200mAh\;g^{-1}$ initial specific discharge capacity, and 50% capacity retention under the same conditions. The activated carbon powder-coated separator also enhances the rate capability. These results indicate that the microstructure of the activated carbon powder layer provides space for the sulfur redox reaction and facilitates fast electron transport. Concurrently, the activated carbon powder layer traps and reutilizes any polysulfides dissolved in the electrolyte. The approach presented here provides insights for overcoming the problems associated with lithium-sulfur batteries and promoting their practical use.

3D Hierarchical Flower-Like Cobalt Ferrite Nanoclusters-Decorated Cotton Carbon Fiber anode with Improved Lithium Storage Performance

  • Meng, Yanshuang;Cheng, Yulong;Ke, Xinyou;Ren, Guofeng;Zhu, Fuliang
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.285-295
    • /
    • 2021
  • The inverse spinel Cobalt ferrite (CoFe2O4, CFO) is considered to be a promising alternative to commercial graphite anodes for lithium ion batteries (LIBs). However, the further development of CFO is limited by its unstable structure during battery cycling and low electrical conductivity. In an effort to address the challenge, we construct three-dimensional hierarchical flower-like CFO nanoclusters (CFO NCs)-decorated carbonized cotton carbon fiber (CFO NCs/CCF) composite. This structure is consisted of microfibers and nanoflower cluster composited of CFO nanoparticle, in which CCF can be used as a long-range conductive matrix, while flower-like CFO NCs can provide abundant active sites, large electrode/electrolyte interface, short lithium ion diffusion path, and alleviated structural stress. As anode materials in LIBs, the flower-like CFO NCs/CCF exhibits excellent electrochemical performance. After 100 cycles at a current density of 0.3 A g-1, the CFO NCs/CCF delivers a discharge/charge capacity of 1008/990 mAh g-1. Even at a high current density of 15 A g-1, it still maintains a charge/discharge capacity of 362/361 mAh g-1.

Development of Cosmetic Packaging for Cream Formulation with Easy Separation and Discharge (분리배출이 용이한 크림제형용 화장품 패키징 개발)

  • Sang Kyu Ryu;Ho Sang Kang;Jae Young Oh
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.2
    • /
    • pp.73-78
    • /
    • 2023
  • The cosmetics industry faces a significant challenge in addressing the decreased recycling rate of cosmetic containers due to the composite materials used to meet consumers' aesthetic satisfaction. To address thees issues, eco-friendly packaging solutions such as refill packaging and single-material use have been developed. However, the market for eco-friendly cosmetics packaging requires a product that meets consumers' demands for aesthetics, sensitivity, and eco-friendliness while also performing as well as existing products. This study presents a solution to the challenge of the decreased recycling rate of cosmetic containers by developing a new cosmetic packaging product for cream formulations. The product features an easily separable and dischargeable internal refill container, while maintaining the design aesthetics of the external container. Through various tests, the product was shown to be of equivalent quality and performance to existing cream cosmetic packaging, with no leakage or defects observed. Furthermore, the use of a single-material polypropylene refill container is expected to contribute to the improvement of the plastic recycling rate.

A Study on the Properties of Nitrogen Purging in Liquefied Hydrogen Vent Pipes (액화수소 벤트 배관의 질소 퍼지에 대한 적정성 연구)

  • Myoung Sun Wu;Chang Jun Lee
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.3
    • /
    • pp.14-19
    • /
    • 2024
  • Hydrogen is one of the most popular eco-friendly energy sources for reducing global warming. To use hydrogen as a conventional fuel, liquid hydrogen plants should introduce waste hydrogen treatment processes. A major safety issue of liquid hydrogen plants is choosing the most suitable purge gas to use in case of an accident. A purge gas prevents the formation of explosive mixed gases in the vent header. In general, nitrogen is the main purge gas used in chemical plants. Nitrogen has a freezing point of -210℃, which is higher than the boiling point of hydrogen. Helium, with a freezing point lower than hydrogen, is instead recommended as a purge gas of the vent header during hydrogen liquefaction. However, helium is roughly 100 times more expensive than nitrogen. To address this issue, this study uses simulations to investigate safe conditions for introducing nitrogen as the purge gas during hydrogen liquefaction. The temperature change from the safety valve to the vent header is evaluated when the external temperature of the safety valve discharge pipe is at 5℃, 10℃, and 20℃. Additionally, the most optimal length for a discharge pipe according to pipe diameter is investigated.

Study on Surface Characteristics of Fe Doped MgO Protective Layer (Fe가 첨가된 MgO 보호막의 표면특성 개선에 관한 연구)

  • Lee, Don-Kyu;Park, Cha-Soo;Kim, Kwong-Toe;Sung, Youl-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.106-112
    • /
    • 2010
  • In order to compete with other flat display devices such as Liquid Crystal Displays (LCDs) and organic light emitting diodes (OLEDs), Plasma Display Panels (PDPs) require to have high performances like high image quality, low power consumption and high speed driving. In this paper, Fe doped MgO protective layer was introduced for higher performance. Both the surface characteristics of the deposited thin films and the electro-optical properties of 4 inch test panels were investigated. It has been demonstrated experimentally that ac PDP with Fe doped MgO protective layer has lower discharge voltage than that of undoped MgO film, which corresponds to measured secondary electron emission coefficients. The crystallinity and surface roughness of thin films were determined by XRD patterns and AFM images. In addition, ac PDP with Fe doped MgO protective layer has improved address discharge time lag for high speed driving.

Transport of space charge between sub-pixels in AC-plasma cell discharge

  • Lee, S.B.;Park, E.Y.;Han, Y.G.;Moon, M.W.;Oh, P.Y.;Song, K.B.;Lee, H.J.;Son, C.G.;Jeong, S.H.;Yoo, N.L.;Hong, Y.J.;Jeong, S.J.;Kim, J.H.;Park, S.O.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.929-931
    • /
    • 2006
  • In this experiment, we have investigated that the transported space charge between sub-pixels in AC-plasma cell discharge. The test pulse 30 V, $5{\mu}s$ was applied to the address electrodes of neighbor cells of discharge occurred cells. And we have measured the transported space charge between sub-pixels in accordance with the various last sustain pulse widths t(time gap between the rising edges of sustain and test pulses) of 0.2 to $3{\mu}s$. It was observed that the peak value of transported space charge has been shown to be 21.5pC at $1.0{\mu}s$. And the IR peak value have been occured after $0.51{\mu}s$ with respect to sustain voltage.

  • PDF

Study on Calibration Methods of Discharge Coefficient of Sonic Nozzles using Constant Volume Flow Meter

  • Jeong, Wan-Seop;Sin, Jin-Hyeon;Gang, Sang-Baek;Park, Gyeong-Am;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.17-17
    • /
    • 2010
  • This paper address technical issues in calibrating discharge coefficients of sonic nozzles used to measure the volume flow rate of low vacuum dry pumps. The first challenging issue comes from the technical limit that their calibration results available from the flow measurement standard laboratories do not fully cover the low vacuum measurement range although the use of sonic nozzles for precision measurement of gas flow has been well established in NMIs. The second is to make an ultra low flow sonic nozzlesufficient to measure the throughput range of 0.01 mbar-l/s. Those small-sized sonic nozzles do not only achieve the noble stability and repeatability of gas flow but also minimize effects of the fluctuation of down stream pressures for the measurement of the volume flow rate of vacuum pumps. These distinctive properties of sonic nozzles are exploited to measure the pumping speed of low vacuum dry pumps widely used in the vacuum-related academic and industrial sectors. Sonic nozzles have been standard devices for measurement of steady state gas flow, as recommended in ISO 9300. This paper introduces two small-sized sonic nozzles of diameter 0.03 mm and 0.2 mm precisely machined according to ISO 9300. The constant volume flow meter (CVFM) readily set up in the Vacuum center of KRISS was used to calibrate the discharge coefficients of the machined nozzles. The calibration results were shown to determine them within the 3% measurement uncertainty. Calibrated sonic nozzles were found to be applicable for precision measurement of steady state gas flow in the vacuum process. Both calibrated sonic nozzles are demonstrated to provide the precision measurement of the volume flow rate of the dry vacuum pump within one percent difference in reference to CVFM. Calibrated sonic nozzles are applied to a new 'in-situ and in-field' equipment designed to measure the volume flow rate of low vacuum dry pumps in the semiconductor and flat display processes.

  • PDF

Analysis on the Discharge Characteristics of New Cell Structure for Luminous Efficacy Improvement in an AC Plasma Display Panel (교류형 플라즈마 표시키의 발광 효율 개설을 위한 실 구조의 방전 특성 분석)

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.7-13
    • /
    • 2008
  • Through two-dimensional numerical simulations, we analyzed the effects of new cell structure for the luminous efficacy improvement in an ac plasma display panel. In the new structure with 5 electrodes, two auxiliary electrodes are arranged between X and Y electrodes with long gap. Through the application of adequate auxiliary pulse on the address electrode, the luminous efficacy in the new cell structure showed the improvement of 52[%] in comparison with that of conventional cell structure with short gap between X and Y electrodes. Consequently, as the short gap discharge between auxiliary electrodes decreases and the long gap discharge between X and Y electrodes increases, the result of VUV generation efficacy shows higher improvement. The reliability of simulation result could he confirmed by the experimental result in the test panel.